Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Phys Rev Lett ; 125(17): 172501, 2020 Oct 23.
Artículo en Inglés | MEDLINE | ID: mdl-33156683

RESUMEN

The ^{80}Ge structure was investigated in a high-statistics ß-decay experiment of ^{80}Ga using the GRIFFIN spectrometer at TRIUMF-ISAC through γ, ß-e, e-γ, and γ-γ spectroscopy. No evidence was found for the recently reported 0_{2}^{+} 639-keV level suggested as evidence for low-energy shape coexistence in ^{80}Ge. Large-scale shell model calculations performed in ^{78,80,82}Ge place the 0_{2}^{+} level in ^{80}Ge at 2 MeV. The new experimental evidence combined with shell model predictions indicate that low-energy shape coexistence is not present in ^{80}Ge.

2.
Phys Rev Lett ; 125(10): 102502, 2020 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-32955302

RESUMEN

The low-spin structure of the semimagic ^{64}Ni nucleus has been considerably expanded: combining four experiments, several 0^{+} and 2^{+} excited states were identified below 4.5 MeV, and their properties established. The Monte Carlo shell model accounts for the results and unveils an unexpectedly complex landscape of coexisting shapes: a prolate 0^{+} excitation is located at a surprisingly high energy (3463 keV), with a collective 2^{+} state 286 keV above it, the first such observation in Ni isotopes. The evolution in excitation energy of the prolate minimum across the neutron N=40 subshell gap highlights the impact of the monopole interaction and its variation in strength with N.

3.
Phys Rev Lett ; 124(5): 052501, 2020 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-32083900

RESUMEN

The rare phenomenon of nuclear wobbling motion has been investigated in the nucleus ^{187}Au. A longitudinal wobbling-bands pair has been identified and clearly distinguished from the associated signature-partner band on the basis of angular distribution measurements. Theoretical calculations in the framework of the particle rotor model are found to agree well with the experimental observations. This is the first experimental evidence for longitudinal wobbling bands where the expected signature partner band has also been identified, and establishes this exotic collective mode as a general phenomenon over the nuclear chart.

4.
Phys Rev Lett ; 123(10): 102501, 2019 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-31573317

RESUMEN

An extensive, model-independent analysis of the nature of triaxial deformation in ^{76}Ge, a candidate for neutrinoless double-beta (0νßß) decay, was carried out following multistep Coulomb excitation. Shape parameters deduced on the basis of a rotational-invariant sum-rule analysis provided considerable insight into the underlying collectivity of the ground-state and γ bands. Both sequences were determined to be characterized by the same ß and γ deformation parameter values. In addition, compelling evidence for low-spin, rigid triaxial deformation in ^{76}Ge was obtained for the first time from the analysis of the statistical fluctuations of the quadrupole asymmetry deduced from the measured E2 matrix elements. These newly determined shape parameters are important input and constraints for calculations aimed at providing, with suitable accuracy, the nuclear matrix elements relevant to 0νßß.

5.
Phys Rev Lett ; 120(21): 212501, 2018 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-29883168

RESUMEN

A sequence of low-energy levels in _{32}^{78}Ge_{46} has been identified with spins and parity of 2^{+}, 3^{+}, 4^{+}, 5^{+}, and 6^{+}. Decays within this band proceed strictly through ΔJ=1 transitions, unlike similar sequences in neighboring Ge and Se nuclei. Above the 2^{+} level, members of this sequence do not decay into the ground-state band. Moreover, the energy staggering of this sequence has the phase that would be expected for a γ-rigid structure. The energies and branching ratios of many of the levels are described well by shell-model calculations. However, the calculated reduced transition probabilities for the ΔJ=2 in-band transitions imply that they should have been observed, in contradiction with the experiment. Within the calculations of Davydov, Filippov, and Rostovsky for rigid-triaxial rotors with γ=30°, there are sequences of higher-spin levels connected by strong ΔJ=1 transitions which decay in the same manner as those observed experimentally, yet are calculated at too high an excitation energy.

6.
J Res Natl Inst Stand Technol ; 117: 143-53, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-26900519

RESUMEN

The dosimeters used to monitor industrial irradiation processing commonly experience significant temperature rises that must be considered in the dose analysis stage. The irradiation-temperature coefficient for a dosimetry system is derived from the dosimeter's radiation response to the absorbed dose and the irradiation temperature. This temperature coefficient is typically expressed in percent change per degree. The temperature rise in dosimeters irradiated with high-intensity ionizing radiation sources can be appreciable. This is especially true for electron-beam processing in which dosimeter temperatures can approach 80 °C. A recent National Institute of Standards and Technology (NIST) study revealed modest (0.5 % to 1.0 %) deviations from the predicted value at temperatures above 70 °C for absorbed doses of 1 kGy and 20 kGy. However, these data were inconsistent with a concurrent manuscript published by National Physical Laboratory (NPL) researchers that found a significant dose-dependent non-linear alanine response but used dosimeters from a different manufacturer and a different experimental design. The current work was undertaken to reconcile the two studies. Alanine dosimeters from each manufacturer used by NIST and NPL were co-irradiated over a wide range of absorbed dose and irradiation temperature. It was found that though there was a slight variation in the temperature coefficient between the two alanine dosimeter sources both systems were linear with irradiation temperature up to 70 °C and the NPL observations of non-linearity were not reproduced. These data confirmed that there is no fundamental difference in the two commercial alanine dosimeter sources and that temperature corrections could be made on industrial irradiations at the extremes of irradiation temperature and absorbed dose.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...