Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Eur J Heart Fail ; 26(1): 34-42, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37823238

RESUMEN

AIMS: There are few prospective reports of 1-year outcomes for women with peripartum cardiomyopathy (PPCM). We report findings from the European Society of Cardiology EURObservational Research Programme PPCM Registry. METHODS AND RESULTS: The registry enrolled women from 51 countries from 2012 to 2018. Eligibility included: (i) a peripartum state, (ii) signs or symptoms of heart failure, (iii) left ventricular (LV) ejection fraction ≤45%, (iv) exclusion of alternative causes of heart failure. We report mortality, thromboembolism, stroke, rehospitalization, LV recovery and remodelling at 1 year. Differences between regions were compared. One-year mortality data were available in 535 (71%) women and follow-up differed across regions. At 1 year, death from any cause occurred in 8.4% of women, with regional variation (Europe 4.9%, Africa 6.5%, Asia-Pacific 9.2%, Middle East 18.9%; p < 0.001). The frequencies of thromboembolism and stroke were 6.3% and 2.5%, respectively, and were similar across regions. A total of 14.0% of women had at least one rehospitalization and 3.5% had recurrent rehospitalizations (i.e. two or more). Overall, 66.1% of women had recovery of LV function (22% between 6 months and 1 year), with a mean LV ejection fraction increase from baseline of 21.2% (±13.6). Recovery occurred most frequently in Asia-Pacific (77.5%) and least frequently in the Middle East (32.7%). There were significant regional differences in the use of heart failure pharmacotherapies. CONCLUSIONS: Approximately 1 in 12 women with PPCM had died by 1 year and thromboembolism and stroke occurred in 6.3% and 2.5%, respectively. Around 1 in 7 women had been rehospitalized and, in 1 in 3, LV recovery had not occurred. PPCM is associated with substantial mortality and morbidity globally.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Complicaciones Cardiovasculares del Embarazo , Accidente Cerebrovascular , Tromboembolia , Femenino , Humanos , Masculino , Embarazo , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Periodo Periparto , Estudios Prospectivos , Cardiomiopatías/diagnóstico , Función Ventricular Izquierda , Volumen Sistólico , Sistema de Registros , Tromboembolia/epidemiología , Tromboembolia/etiología , Complicaciones Cardiovasculares del Embarazo/diagnóstico
2.
Blood Press Monit ; 28(6): 322-329, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-37661727

RESUMEN

OBJECTIVE: Limited and conflicting data have been reported on the prognostic relevance of central blood pressure (CBP) compared with brachial blood pressure (BP) in the anticipation of hypertension-mediated organ damage and the majority of data derived using applanation tonometry with its known complexities. The objective of the present study was to investigate the diagnostic factors of left ventricular hypertrophy (LVH) with a special highlight on the utility of non-invasive oscillometric CBP measurement and derived hemodynamic indices compared to brachial BP as indicators of LVH. METHODS: This cross-sectional study included 300 hypertensive patients (mean age 55.3 years, 61.3% female, 51.7% obese) with a mean duration of hypertension was 5.8 years. They underwent measurement of brachial BP, using a mercury sphygmomanometer, and CBP, using a Mobil-O-Graph, alongside the determination of left ventricular (LV) mass by two-dimensional transthoracic echocardiography. LVH and LV geometric patterns were defined by LV mass index/height 2.7 and relative wall thickness. RESULTS: Bivariate then multivariate analysis showed that age, BMI, central systolic BP (SBP), and pulse wave velocity (PWV) were significant determinants of LVH and optimally controlled brachial BP was a significant negative determinant for LVH. Central SBP had an acceptable diagnostic performance to determine LVH in patients with hypertension (AUC = 0.722, 95% confidence interval: 0.618-0.824, SE = 0.21, P -value <0.001). Using one-way ANOVA, a comparison of means among age groups showed that the steady increase in central SBP and PWV with aging was greater among LVH patients than non-LVH patients. CONCLUSION: Estimated central SBP using Mobil-O-Graph showed a significantly higher correlation to LVH than brachial SBP values. The consistent increase in central SBP and PWV with aging was greater among LVH patients than non-LVH patients.


Asunto(s)
Hipertensión , Hipertrofia Ventricular Izquierda , Humanos , Femenino , Persona de Mediana Edad , Masculino , Presión Sanguínea/fisiología , Hipertrofia Ventricular Izquierda/diagnóstico , Análisis de la Onda del Pulso , Oscilometría , Estudios Transversales
3.
BMC Cardiovasc Disord ; 23(1): 255, 2023 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-37198541

RESUMEN

BACKGROUND: There is a close relationship between blood pressure levels and the risk of cardiovascular events, strokes, and kidney disease. For many years, the gold standard instrument for blood pressure measurement was a mercury sphygmomanometer and a stethoscope, but this century-old technique of Riva-Rocci/Korotkov is being progressively removed from clinical practice. Central blood pressure is considered better than peripheral blood pressure in predicting cardiovascular events, as it assesses wave reflections and viscoelastic properties of the arterial wall which make systolic and pulse pressures vary from central to peripheral arteries, but mean blood pressure is constant in the conduit arteries. METHODS: The study included 201 patients with primary hypertension (108 patients with chronic kidney disease and 93 patients without kidney disease). All patients underwent blood pressure measurement by OMRON M2 and Mobil-O-Graph devices, kidney function assessment and abdominal ultrasonography. RESULTS: Patients with chronic kidney disease were significantly older (60.02 ± 9.1 vs. 55.33 ± 8.5; P < 0.001), with longer duration of hypertension (7.56 ± 5.9 vs. 6.05 ± 5.8; P = 0.020) in comparison to those without chronic kidney disease. Automated peripheral measurement of systolic blood pressure, diastolic blood pressure and pulse pressure were significantly higher in comparison to central blood pressure. Patients with chronic kidney disease had significantly higher augmentation index (24.06 ± 12.6 vs. 19.02 ± 10.8; P < 0.001) and pulsed wave velocity (8.66 ± 1.5 vs. 8.69 ± 6.8; P = 0.004) in comparison to those without chronic kidney disease. Augmentation index had positive correlation with pulse wave velocity (r = 0.183, P = 0.005). There was negative correlation between both pulse wave velocity and augmentation index and estimated glomerular filtration rate (r = -0.318, P < 0.001), and (r = -0.236, P < 0.001), respectively. Hence, arterial stiffness parameters are good positive test for prediction of chronic kidney disease. CONCLUSION: There is a strong agreement between non-invasive centrally and automated peripherally measured blood pressure in diagnosis of hypertension. But non-invasive central measurements are preferred over automated measurements for early prediction and detection of renal impairment.


Asunto(s)
Hipertensión , Insuficiencia Renal Crónica , Insuficiencia Renal , Rigidez Vascular , Humanos , Presión Sanguínea/fisiología , Análisis de la Onda del Pulso , Hipertensión/complicaciones , Hipertensión/diagnóstico , Insuficiencia Renal Crónica/complicaciones , Insuficiencia Renal Crónica/diagnóstico , Riñón , Rigidez Vascular/fisiología
4.
J Cardiovasc Electrophysiol ; 33(5): 1034-1040, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35243712

RESUMEN

INTRODUCTION: We hypothesized that an accurate assessment of preoperative venography could be useful in predicting transvenous lead extraction (TLE) difficulty. METHODS AND RESULTS: A dedicated preoperative venogram was performed in consecutive patients with cardiac implantable electronic device who underwent TLE. The level of stenosis was classified as without significant stenosis, moderate, severe, and occlusion. The presence of extensive lead-venous wall adherence (≥50 mm) was also assessed. A total of 105 patients (median age: 71 years; 72% male) with a median of 2 (1-2) leads to extract were enrolled. Preoperative venography showed moderate to severe stenosis in 31 (30%), complete occlusion in 15 (14%), and extensive lead-venous wall adherence in 50 (48%) patients. Complete TLE success was achieved in 103 (98%) patients. A total of 55 (52%) were advanced extractions as they required a powered mechanical and/or laser sheath. They were more prevalent in the group with extensive lead-venous wall adherence (72% vs. 34%, p < .001), while no differences were found between patients with and without venous occlusion. In multivariate analysis, the presence of adherence was a predictor of advanced extraction (odds ratio: 2.89 [1.14-7.32], p = .025). The fluoroscopy time was also significantly longer (14.0 [8.2-18.7] vs. 5.1 [2.1-10.0] min, p < .001). The rate of complications did not differ based on the presence of venous lesions. CONCLUSION: Although procedural success and complication rates were similar, patients with extensive lead-venous wall adherence required a longer fluoroscopy time and were three times more likely to need advanced extraction tools. Conversely, the presence of total venous occlusion had no impact on the procedure complexity.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Enfermedades Vasculares , Anciano , Constricción Patológica , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/métodos , Femenino , Humanos , Masculino , Flebografía , Estudios Retrospectivos , Resultado del Tratamiento
5.
Am J Emerg Med ; 50: 413-421, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34481261

RESUMEN

BACKGROUND: One promising biomarker that has received substantial interest for the evaluation of suspected acute coronary syndromes (ACS) is copeptin. Therefore, our goal was to assess the additive value of copeptin for early diagnosis and prognosis of Non-ST segment acute coronary syndromes (NSTE-ACS). METHODS: The study included ninety patients with suspected ACS. Patients with typical ischemic chest pain within six hours of symptom onset and without ST-segment elevation on electrocardiograph (ECG) were included. In addition to cardiac troponin I (cTnI), copeptin was assayed from venous blood samples obtained on admission, followed by serial troponin measurements six and twelve hours later. One year follow-up was performed for any major adverse cardiac events (MACEs) including cardiac death, re-infarction, re- hospitalization for ischemic events, heart failure, stroke and target lesion revascularization (TLR). RESULTS: Of seventy nine patients included in the final analysis, Forty (50.6%) were diagnosed as unstable angina (UA), while thirty nine (49.4%) had a non-ST elevation myocardial infarction (NSTEMI). Copeptin level on admission was significantly higher among NSTEMI patients than those with UA. With regard to the correlation analyses, copeptin was positively correlated with each of, Global Registry of Acute Coronary Events (GRACE), Thrombolysis In Myocardial Infarction (TIMI) and synergy between percutaneous coronary intervention with taxus and cardiac surgery (SYNTAX) scores. The sensitivity and negative predictive value (NPV) of the combination of admission copeptin and cTn-I were 100% and 100%, respectively, versus 57% and 70%, respectively, with admission of cTn-I alone. The area under curve (AUC) of the combination of copeptin and cTn-I was (0.975, p < 0.001) and was significantly higher than the AUC of cTn-I alone (0.888, p < 0.001). Admission copeptin was an independent predictor for MACEs by multiple regression analysis (OR: 0.01, 95% CI: 0.0-0.8, P = 0.04). High values of copeptin had the highest rate of MACEs and coronary revascularization during one year of follow up. CONCLUSION: The combination of copeptin and conventional troponin I aids in early rule out of NSTEMI virtually independent of chest pain onset (CPO) with high NPV in patients presenting within three hours from chest pain onset with excellent prognostic value for risk stratification and prediction of MACEs.


Asunto(s)
Síndrome Coronario Agudo/diagnóstico , Glicopéptidos/sangre , Biomarcadores/sangre , Diagnóstico Precoz , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos , Troponina/sangre
6.
Eur J Heart Fail ; 23(12): 2058-2069, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34114268

RESUMEN

AIMS: Hypertensive disorders occur in women with peripartum cardiomyopathy (PPCM). How often hypertensive disorders co-exist, and to what extent they impact outcomes, is less clear. We describe differences in phenotype and outcomes in women with PPCM with and without hypertensive disorders during pregnancy. METHODS AND RESULTS: The European Society of Cardiology EURObservational Research Programme PPCM Registry enrolled women with PPCM from 2012-2018. Three groups were examined: (i) women without hypertension (PPCM-noHTN); (ii) women with hypertension but without pre-eclampsia (PPCM-HTN); (iii) women with pre-eclampsia (PPCM-PE). Maternal (6-month) and neonatal outcomes were compared. Of 735 women included, 452 (61.5%) had PPCM-noHTN, 99 (13.5%) had PPCM-HTN and 184 (25.0%) had PPCM-PE. Compared to women with PPCM-noHTN, women with PPCM-PE had more severe symptoms (New York Heart Association class IV in 44.4% vs. 29.9%, P < 0.001), more frequent signs of heart failure (pulmonary rales in 70.7% vs. 55.4%, P = 0.002), a higher baseline left ventricular ejection fraction (LVEF) (32.7% vs. 30.7%, P = 0.005) and a smaller left ventricular end-diastolic diameter (57.4 ± 6.7 mm vs. 59.8 ± 8.1 mm, P = 0.001). There were no differences in the frequencies of death from any cause, rehospitalization for any cause, stroke, or thromboembolic events. Compared to women with PPCM-noHTN, women with PPCM-PE had a greater likelihood of left ventricular recovery (LVEF ≥ 50%) (adjusted odds ratio 2.08, 95% confidence interval 1.21-3.57) and an adverse neonatal outcome (composite of termination, miscarriage, low birth weight or neonatal death) (adjusted odds ratio 2.84, 95% confidence interval 1.66-4.87). CONCLUSION: Differences exist in phenotype, recovery of cardiac function and neonatal outcomes according to hypertensive status in women with PPCM.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Hipertensión Inducida en el Embarazo , Complicaciones Cardiovasculares del Embarazo , Cardiomiopatías/complicaciones , Cardiomiopatías/diagnóstico , Cardiomiopatías/epidemiología , Femenino , Insuficiencia Cardíaca/complicaciones , Humanos , Hipertensión Inducida en el Embarazo/epidemiología , Periodo Periparto , Embarazo , Sistema de Registros , Volumen Sistólico , Función Ventricular Izquierda
7.
J Cardiovasc Electrophysiol ; 32(5): 1407-1410, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33783892

RESUMEN

PURPOSE: Predictors of difficulty and complications of transvenous lead extraction (TLE) have been investigated in several studies; however, little is known about the venous anatomical characteristics that can have an impact on procedural outcomes. Among them, the persistent left superior vena cava (PLSVC) is a common anomaly often discovered incidentally during cardiac device implantation and could raise concerns if TLE is indicated. We report technical considerations and outcomes of TLE for two patients with leads implanted via PLSVC. METHODS AND RESULTS: Two cardiac implantable electronic device recipients with isolated PLSVC required TLE due to infective endocarditis in one case and lead failure in the other. In the first case, TLE procedure was performed in a hybrid operating room with minimally invasive video-assisted thoracoscopic monitoring due to the high procedural risk. Two active fixation 20-year-old pacing leads were removed with a relatively short fluoroscopy time. In the second case, we successfully extracted a single-coil active fixation lead without the need of a locking stylet or advanced extraction tools. There were no procedural complications or adverse events at 1-year follow-up. CONCLUSION: TLE procedures for two patients with isolated PLSVC were successfully completed with less difficulty and tools than expected based on the characteristics of the targeted leads. If indicated, TLE in the presence of a PLSVC should be considered in experienced centers.


Asunto(s)
Vena Cava Superior Izquierda Persistente , Vena Cava Superior , Remoción de Dispositivos , Fluoroscopía , Humanos , Resultado del Tratamiento , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
8.
Egypt Heart J ; 71(1): 14, 2019 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-31659522

RESUMEN

BACKGROUND: Both ambulatory blood pressure (AMBP) and non-invasive central blood pressure (NCBP) monitoring could be used as predictors for early detection of hypertensive end organ damage (EOD). However, the comparison between these two methods needs more clarification. Our cross-sectional study included 100 hypertensive patients with a mean age of 47.52 ± 8.35 years on regular antihypertensive treatment for ≥ 1 year (50 controlled, 50 uncontrolled). We compared associations, sensitivity, and specificity of EOD parameters with office, AMBP, and NCBP measurements. We measured left ventricular mass index (LVMI), carotid intimal medial thickness (CIMT), ankle-brachial index (ABI), serum creatinine, glomerular filtration rate (GFR), and pulse wave velocity (PWV). RESULTS: We found a significant relation between SBP of NCBP, AMBP and LVMI, and CIMT, PWV, and GFR respectively (P < 0.05) while office SBP showed no significant relation. Systolic AMBP showed a high sensitivity to ABI (98%) and CIMT (92%) while systolic NCBP had 92% specificity and DBP showed 90% sensitivity for ABI. CONCLUSION: AMBP and NCBP show a significant relation to LVMI, CIMT, PWV, and GFR with little superiority of central BP while office BP does not. Systolic ABPM has high sensitivity to ABI and CIMT and systolic NCBP has a high sensitivity and specificity to ABI.

9.
Cardiovasc Diagn Ther ; 9(1): 8-17, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30881872

RESUMEN

BACKGROUND: After successful pulmonary vein isolation (PVI) for atrial fibrillation (AF), the left atrium (LA) undergoes reverse remodeling. However, few studies have directly studied pulmonary vein (PV) remodeling and focused on whether pre PVI-PV conditions could predict outcome of the procedure. We hypothesize that: (I) post PVI, in addition to LA remodeling the PVs undergo a parallel degree of remodeling; and (II) that PV characteristics pre PVI can be used to identify patients more likely to sustain normal sinus rhythm (NSR). METHODS: Patients (n=100) scheduled for PVI had a cardiovascular magnetic resonance (CMR) imaging before and 6±2 months following PVI. PV cross sectional areas (CSA) within 0.5 cm of the ostium and LA volumes were measured. Patients were categorized as responders (R) or non-responders (NR), based on two separate 14-day Holter monitoring. RESULTS: PVs CSA were significantly reduced post procedure in both groups, R (233±53 to 192±52 mm2, P<0.001) and NR (241±54 to 207±44 mm2, P<0.001), however, the difference between R and NR post PVI was not significant (192±52 to 207±44 mm2, P=0.19). Reduction in PVs CSAs post procedure moderately correlated with the 3D LA volume reduction (r=0.48, P<0.001). CONCLUSIONS: PVs mirror the LA in that they significantly change in size following PVI yet they were not found to directly predict maintenance of NSR.

10.
Ther Adv Cardiovasc Dis ; 10(1): 30-6, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26627265

RESUMEN

INTRODUCTION: Data about plasma levels of neutrophil gelatinase-associated lipocalin (NGAL) in children with heart failure (HF) are very limited. NGAL is used widely as a biomarker for the diagnosis of renal injury in numerous clinical studies. The aim of this study is to investigate the plasma NGAL in children with HF caused by idiopathic dilated cardiomyopathy (IDCM) and its relation to the severity of HF. MATERIAL AND METHODS: In a case-control study, 30 nondiabetic children, aged -16 years (all have IDCM) recruited from the pediatric department of our institute together with 30 healthy children were prospectively enrolled in this study. Patients underwent a detailed history taking, clinical examination, New York Heart Association (NYHA) class assessment and echocardiographic evaluation. Plasma levels of NGAL were measured by enzyme-linked immunosorbent assay. RESULTS: Plasma levels of NGAL were significantly higher in children with HF compared with healthy controls (mean: 290.97 versus 144.33, p < 0.0001). The relationship between NGAL and the severity of HF was investigated. However, we did not find any statistically significant relationship between plasma NGAL levels and indices of myocardial function. CONCLUSIONS: NGAL levels were significantly increased in children with HF caused by IDCM. However, there was no significant relationship between plasma NGAL levels and indices of myocardial function. Future multicenter clinical studies in a large population addressing the natural course of NGAL in HF and its potential as a treatment target are needed in the near future.


Asunto(s)
Cardiomiopatía Dilatada/complicaciones , Insuficiencia Cardíaca/sangre , Lipocalinas/sangre , Proteínas Proto-Oncogénicas/sangre , Proteínas de Fase Aguda , Adolescente , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Lipocalina 2 , Masculino , Estudios Prospectivos , Índice de Severidad de la Enfermedad
11.
Europace ; 14(1): 112-6, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21873627

RESUMEN

AIMS: The number of implanted cardiac rhythm devices has rapidly increased in the past decade. Subsequently, the need for lead extraction has also increased. Several techniques of lead removal have been documented from manual traction of the lead to lead extraction assisted with mechanical or laser sheaths. The goal of this study was to review our experience with lead removal using manual traction without the assistance of extraction sheaths. METHODS AND RESULTS: In the Leiden University Medical Center all leads are removed using manual traction without the assistance of extraction sheaths. We have retrospectively reviewed all lead removal procedures performed between 2000 and 2009. Procedures were reviewed for indication, success, complication rates, and mortality. In total, 279 lead removal procedures were included. During these procedures 445 leads were removed. Time since lead implantation: 4.2 ± 4.7 years. During extraction 53(11.9%) leads fractured, of which >50% could still be completely removed using a femoral approach. A longer implantation duration [odds ratio (OR) 1.16 per year, 95% confidence interval (CI) 1.09-1.23] and passive fixation (OR 2.52, 95%CI 1.17-5.45) significantly associated with the chance of lead fracture during lead removal. Clinical success, using the primary approach of manual traction from the pectoral area, was obtained in 228 (84.8%) procedures. Major complications occurred in 2(0.7%) and minor in 13(4.7%) procedures. One patient died within 24 h after the procedure due to septic shock. There was no further mortality within the first month after the procedure. CONCLUSION: Lead removal using manual traction, without the assistance of lead extraction sheaths, is clinically successful in ~85% of the lead extraction procedures. Concomitant morbidity and mortality are low. The highest clinical success (~95%) was observed in patients with leads implanted less than 2.6 years.


Asunto(s)
Desfibriladores Implantables , Remoción de Dispositivos/métodos , Adulto , Anciano , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/instrumentación , Remoción de Dispositivos/mortalidad , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
12.
Ann Thorac Med ; 4(4): 187-96, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19881164

RESUMEN

BACKGROUND: A prediction formula for mean pulmonary artery pressure (MPAP) using standard lung function measurement has been recently validated to screen for pulmonary hypertension (PH) in idiopathic pulmonary fibrosis (IPF) patients. OBJECTIVE: To test the usefulness of this formula as a new non invasive screening tool for PH in IPF patients. Also, to study its correlation with patients' clinical data, pulmonary function tests, arterial blood gases (ABGs) and other commonly used screening methods for PH including electrocardiogram (ECG), chest X ray (CXR), trans-thoracic echocardiography (TTE) and computerized tomography pulmonary angiography (CTPA). MATERIALS AND METHODS: Cross-sectional study of 37 IPF patients from tertiary hospital. The accuracy of MPAP estimation was assessed by examining the correlation between the predicted MPAP using the formula and PH diagnosed by other screening tools and patients' clinical signs of PH. RESULTS: There was no statistically significant difference in the prediction of PH using cut off point of 21 or 25 mm Hg (P = 0.24). The formula-predicted MPAP greater than 25 mm Hg strongly correlated in the expected direction with O2 saturation (r = -0.95, P < 0.000), partial arterial O2tension (r = -0.71, P < 0.000), right ventricular systolic pressure measured by TTE (r = 0.6, P < 0.000) and hilar width on CXR (r = 0.31, P = 0.03). Chest symptoms, ECG and CTPA signs of PH poorly correlated with the same formula (P > 0.05). CONCLUSIONS: The prediction formula for MPAP using standard lung function measurements is a simple non invasive tool that can be used as TTE to screen for PH in IPF patients and select those who need right heart catheterization.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...