Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JACC Cardiovasc Interv ; 12(5): 413-419, 2019 03 11.
Artículo en Inglés | MEDLINE | ID: mdl-30772290

RESUMEN

OBJECTIVES: This study sought to describe the procedural and clinical outcomes of patients undergoing transcarotid (TC) transcatheter aortic valve replacement (TAVR) with the Edwards Sapien 3 device. BACKGROUND: The TC approach for TAVR holds the potential to become the optimal alternative to the transfemoral gold standard. Limited data exist regarding safety and efficacy of TC-TAVR using the Edwards Sapien 3 device. METHODS: The French Transcarotid TAVR prospective multicenter registry included patients between 2014 and 2018. Consecutive patients treated in 1 of the 13 participating centers ineligible for transfemoral TAVR were screened for TC-TAVR. Clinical and echocardiographic data were prospectively collected. Perioperative and 30-day outcomes were reported according to the updated Valve Academic Research Consortium (VARC-2). RESULTS: A total of 314 patients were included with a median (interquartile range) age of 83 (78 to 88) years, 63% were males, Society of Thoracic Surgeons mortality risk score 5.8% (4% to 8.3%). Most patients presented with peripheral artery disease (64%). TC-TAVR was performed under general anesthesia in 91% of cases, mostly using the left carotid artery (73.6%) with a procedural success of 97%. Three annulus ruptures were reported, all resulting in patient death. At 30 days, rates of major bleeding, new permanent pacemaker, and stroke or transient ischemic attack were 4.1%, 16%, and 1.6%, respectively. The 30-day mortality was 3.2%. CONCLUSIONS: TC-TAVR using the Edwards Sapien 3 device was safe and effective in this prospective multicenter registry. The TC approach might be considered, in selected patients, as the first-line alternative approach for TAVR whenever the transfemoral access is prohibited. Sapien 3 device was safe and effective in our multicenter cohort.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Arterias Carótidas , Cateterismo Periférico , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/mortalidad , Femenino , Francia , Humanos , Masculino , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Estudios Prospectivos , Diseño de Prótesis , Punciones , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...