Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Phys Rev Lett ; 130(17): 173001, 2023 Apr 28.
Artículo en Inglés | MEDLINE | ID: mdl-37172243

RESUMEN

To test bound-state quantum electrodynamics (BSQED) in the strong-field regime, we have performed high precision x-ray spectroscopy of the 5g-4f and 5f- 4d transitions (BSQED contribution of 2.4 and 5.2 eV, respectively) of muonic neon atoms in the low-pressure gas phase without bound electrons. Muonic atoms have been recently proposed as an alternative to few-electron high-Z ions for BSQED tests by focusing on circular Rydberg states where nuclear contributions are negligibly small. We determined the 5g_{9/2}- 4f_{7/2} transition energy to be 6297.08±0.04(stat)±0.13(syst) eV using superconducting transition-edge sensor microcalorimeters (5.2-5.5 eV FWHM resolution), which agrees well with the most advanced BSQED theoretical prediction of 6297.26 eV.

2.
Phys Rev Lett ; 128(11): 112503, 2022 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-35363014

RESUMEN

We have measured the 3d→2p transition x rays of kaonic ^{3}He and ^{4}He atoms using superconducting transition-edge-sensor microcalorimeters with an energy resolution better than 6 eV (FWHM). We determined the energies to be 6224.5±0.4(stat)±0.2(syst) eV and 6463.7±0.3(stat)±0.1(syst) eV, and widths to be 2.5±1.0(stat)±0.4(syst) eV and 1.0±0.6(stat)±0.3(stat) eV, for kaonic ^{3}He and ^{4}He, respectively. These values are nearly 10 times more precise than in previous measurements. Our results exclude the large strong-interaction shifts and widths that are suggested by a coupled-channel approach and agree with calculations based on optical-potential models.

3.
J Low Temp Phys ; 209(5-6)2022.
Artículo en Inglés | MEDLINE | ID: mdl-37427309

RESUMEN

The nonlinear energy response of cryogenic microcalorimeters is usually corrected through an empirical calibration. X-ray or gamma-ray emission lines of known shape and energy anchor a smooth function that generalizes the calibration data and converts detector measurements to energies. We argue that this function should be an approximating spline. The theory of Gaussian process regression makes a case for this functional form. It also provides an important benefit previously absent from our calibration method: a quantitative uncertainty estimate for the calibrated energies, with lower uncertainty near the best-constrained calibration points.

4.
Metrologia ; 58(1)2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34354301

RESUMEN

We use an array of transition-edge sensors, cryogenic microcalorimeters with 4 eV energy resolution, to measure L x-ray emission-line profiles of four elements of the lanthanide series: praseodymium, neodymium, terbium, and holmium. The spectrometer also surveys numerous x-ray standards in order to establish an absolute-energy calibration traceable to the international system of units for the energy range 4 keV to 10 keV. The new results include emission line profiles for 97 lines, each expressed as a sum of one or more Voigt functions; improved absolute energy uncertainty on 71 of these lines relative to existing reference data; a median uncertainty on the peak energy of 0.24 eV, four to ten times better than the median of prior work; and six lines that lack any measured values in existing reference tables. The 97 lines comprise nearly all of the most intense L lines from these elements under broad-band x-ray excitation. The work improves on previous measurements made with a similar cryogenic spectrometer by the use of sensors with better linearity in the absorbed energy and a gold x-ray absorbing layer that has a Gaussian energy-response function. It also employs a novel sample holder that enables rapid switching between science targets and calibration targets with excellent gain balancing. Most of the results for peak energy values shown here should be considered as replacements for the currently tabulated standard reference values, while the line shapes given here represent a significant expansion of the scope of available reference data.

5.
Phys Rev Lett ; 127(5): 053001, 2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34397250

RESUMEN

We observed electronic K x rays emitted from muonic iron atoms using superconducting transition-edge sensor microcalorimeters. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic Kα and Kß x rays together with the hypersatellite K^{h}α x rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the L-shell electrons, accompanied by electron side feeding. Assisted by a simulation, these data clearly reveal the electronic K- and L-shell hole production and their temporal evolution on the 10-20 fs scale during the muon cascade process.

6.
Transl Anim Sci ; 5(2): txab084, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34124592

RESUMEN

The aim of this experiment was to evaluate the effect of undenatured type II collagen supplementation on inflammation and cartilage degeneration after exercise in healthy dogs. Forty healthy Labrador Retrievers (20 male/20 female; range 5-12 yr; average 8 yr) were sorted into two groups: undenatured type II collagen group receiving 40 mg UC-II (10 mg collagen type II/min. 3% undenatured type II collagen; Lonza Consumer Health, Inc.) and placebo group receiving 40 mg maltodextrin daily by capsule. After 2-wk loading, all dogs began an 11-wk endurance exercise regimen consisting of two weekly runs, starting at 5 km and increasing incrementally to 8 km, with one final 16 km run. Blood samples were collected at baseline, pre and post first 5 km run, and pre- and post-16 km run. Activity per kilometer was greater in male undenatured type II collagen vs. male placebo over all runs (P = 0.004), and average moving speed was greater in all undenatured type II collagen dogs compared with placebo over all runs (P < 0.001). Hematology analysis indicated that during the first insult, undenatured type II collagen dogs had a greater lymphocyte count (P < 0.001) and lymphocyte percentage (P = 0.001) vs. placebo dogs. Undenatured type II collagen dogs had a lesser neutrophil percentage (P = 0.042) and neutrophil to lymphocyte ratios (P = 0.001) compared to placebo dogs. For the final insult, undenatured type II collagen dogs had greater lymphocyte percentage (P = 0.013) and lesser mean corpuscular hemoglobin concentration (P = 0.043) compared with placebo dogs. Both groups had significant changes between timepoints for several hematological parameters. Biomarker IL-6 was lesser in undenatured type II collagen dogs compared with placebo at post 5 km (P = 0.037). Cartilage oligomeric matrix protein (COMP) was lesser in undenatured type II collagen dogs at post 16 km (P = 0.023), and only the placebo dogs had a significant increase in COMP from pre to post 16 km (P = 0.021). In summary, Labrador Retrievers supplemented with undenatured type II collagen had decreased inflammation and cartilage degeneration compared with nonsupplemented dogs during exercise.

7.
IEEE Trans Appl Supercond ; 29(5)2019 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-31360051

RESUMEN

Readout of a large, spacecraft-based array of superconducting transition-edge sensors (TESs) requires careful management of the layout area and power dissipation of the cryogenic-circuit components. We present three optimizations of our time- (TDM) and code-division-multiplexing (CDM) systems for the X-ray Integral Field Unit (X-IFU), a several-thousand-pixel-TES array for the planned Athena-satellite mission. The first optimization is a new readout scheme that is a hybrid of CDM and TDM. This C/TDM architecture balances CDM's noise advantage with TDM's layout compactness. The second is a redesign of a component: the shunt resistor that provides a dc-voltage bias to the TESs. A new layout and a thicker Pd-Au resistive layer combine to reduce this resistor's area by more than a factor of 5. Third, we have studied the power dissipated by the first-stage SQUIDs (superconducting quantum-interference devices) and the readout noise versus the critical current of the first-stage SqUIDs. As a result, the X-IFU TDM and C/TDM SQUIDs will have a specified junction critical current of 5 µA. Based on these design optimizations and TDM experiments described by Durkin, et al. (these proceedings), TDM meets all requirements to be X-IFU's backup-readout option. Hybrid C/TDM is another viable option that could save spacecraft resources.

8.
Artículo en Inglés | MEDLINE | ID: mdl-31160861

RESUMEN

Time-division multiplexing (TDM) is the backup readout technology for the X-ray Integral Field Unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) array that will provide imaging spectroscopy for ESA's Athena satellite mission. X-0IFU design studies are considering readout with a multiplexing factor of up to 40. We present data showing 40-row TDM readout (32 TES rows + 8 repeats of the last row) of TESs that are of the same type as those being planned for X-IFU, using measurement and analysis parameters within the ranges specified for X-IFU. Singlecolumn TDM measurements have best-fit energy resolution of (1.91 ± 0.01) eV for the Al Kα complex (1.5 keV), (2.10 ± 0.02) eV for Ti Kα (4.5 keV), (2.23 ± 0.02) eV for Mn Kα (5.9 keV), (2.40 ± 0.02) eV for Co Kα (6.9 keV), and (3.44 ± 0.04) eV for Br Kα (11.9 keV). Three-column measurements have best-fit resolution of (2.03 ± 0.01) eV for Ti Kα and (2.40 ± 0.01) eV for Co Kα. The degradation due to the multiplexed readout ranges from 0.1 eV at the lower end of the energy range to 0.5 eV at the higher end. The demonstrated performance meets X-IFU's energy-resolution and energy-range requirements. True 40-row TDM readout, without repeated rows, of kilopixel scale arrays of X-IFU-like TESs is now under development.

9.
J Low Temp Phys ; 199(3-4)2019.
Artículo en Inglés | MEDLINE | ID: mdl-33364637

RESUMEN

A principal component analysis (PCA) of clean microcalorimeter pulse records can be a first step beyond statistically optimal linear filtering of pulses toward a fully nonlinear analysis. For PCA to be practical on spectrometers with hundreds of sensors, an automated identification of clean pulses is required. Robust forms of PCA are the subject of active research in machine learning. We examine a version known as coherence pursuit that is simple and fast and well matched to the automatic identification of outlier records, as needed for microcalorimeter pulse analysis.

10.
Rev Sci Instrum ; 90(12): 123107, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31893849

RESUMEN

We report on the design, commissioning, and initial measurements of a Transition-Edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the NIST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ∼30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8000 eV and achieve an energy resolution of 3.7 eV-5.0 eV over this range, a more modest (<2×) improvement over the previous microcalorimeters. Beyond this energy range, NETS can operate with various trade-offs, the most significant of which are reduced efficiency at lower energies and being limited to a subset of the pixels at higher energies. As an initial demonstration of the capabilities of NETS, we measured transitions in He-like and H-like O, Ne, and Ar as well as Ni-like W. We detail the energy calibration and data analysis techniques used to transform detector counts into x-ray spectra, a process that will be the basis for analyzing future data.

11.
J Nutr Sci ; 6: e8, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28620483

RESUMEN

The primary goal was to investigate the effects of l-carnitine on fuel efficiency, as an antioxidant, and for muscle recovery in Labrador retrievers. Dogs were split into two groups, with one group being supplemented with 250 mg/d of Carniking™ l-carnitine powder. Two experiments (Expt 1 and Expt 2) were performed over a 2-year period which included running programmes, activity monitoring, body composition scans and evaluation of recovery using biomarkers. Each experiment differed slightly in dog number and design: fifty-six v. forty dogs; one endurance and two sprint runs per week v. two endurance runs; and differing blood collection time points. All dogs were fed a low-carnitine diet in which a fixed amount was offered based on maintaining the minimum starting weight. Results from Expt 1 found that the carnitine dogs produced approximately 4000 more activity points per km compared with the control group during sprint (P = 0·052) and endurance runs (P = 0·0001). Male carnitine dogs produced half the creatine phosphokinase (CPK) following exercise compared with male control dogs (P = 0·05). Carnitine dogs had lower myoglobin at 6·69 ng/ml following intensive exercise compared with controls at 24·02 ng/ml (P = 0·0295). Total antioxidant capacity (TAC) and thiobarbituric acid reactive substance (TBARS) results were not considered significant. In Expt 2, body composition scans indicated that the carnitine group gained more total tissue mass while controls lost tissue mass (P = 0·0006) and also gained lean mass while the control group lost lean mass (P < 0·0001). Carnitine dogs had lower CPK secretion at 23·06 v. control at 28·37 mU/ml 24 h after post-run (P = 0·003). Myoglobin levels were lower in carnitine v. control dogs both 1 h post-run (P = 0·0157; 23·83 v. 37·91 ng/ml) and 24 h post-run (P = 0·0189; 6·25 v.13·5 ng/ml). TAC indicated more antioxidant activity in carnitine dogs at 0·16 mm v. control at 0·13 mm (P = 0·0496). TBARS were also significantly lower in carnitine dogs both pre-run (P = 0·0013; 15·36 v. 23·42 µm) and 1 h post-run (P = 0·056; 16·45 v. 20·65 µm). Supplementing l-carnitine in the form of Carniking™ had positive benefits in Labrador retrievers for activity intensity, body composition, muscle recovery and oxidative capacity.

12.
Rev Sci Instrum ; 88(5): 053108, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28571411

RESUMEN

We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.

13.
J Low Temp Phys ; 184(1): 389-395, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27325902

RESUMEN

Time-division multiplexing (TDM) is a mature scheme for the readout of arrays of transition-edge sensors (TESs). TDM is based on superconducting-quantum-interference-device (SQUID) current amplifiers. Multiple spectrometers based on gamma-ray and X-ray microcalorimeters have been operated with TDM readout, each at the scale of 200 sensors per spectrometer, as have several astronomical cameras with thousands of sub-mm or microwave bolometers. Here we present the details of two different versions of our TDM system designed to read out X-ray TESs. The first has been field-deployed in two 160-sensor (8 columns × 20 rows) spectrometers and four 240-sensor (8 columns × 30 rows) spectrometers. It has a three-SQUID-stage architecture, switches rows every 320 ns, and has total readout noise of 0.41 µΦ0/√Hz. The second, which is presently under development, has a two-SQUID-stage architecture, switches rows every 160 ns, and has total readout noise of 0.19 µΦ0/√Hz. Both quoted noise values are non-multiplexed and referred to the first-stage SQUID. In a demonstration of this new architecture, a multiplexed 1-column × 32-row array of NIST TESs achieved average energy resolution of 2.55±0.01 eV at 6 keV.

14.
J Synchrotron Radiat ; 22(3): 766-75, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25931095

RESUMEN

X-ray emission spectroscopy (XES) is a powerful element-selective tool to analyze the oxidation states of atoms in complex compounds, determine their electronic configuration, and identify unknown compounds in challenging environments. Until now the low efficiency of wavelength-dispersive X-ray spectrometer technology has limited the use of XES, especially in combination with weaker laboratory X-ray sources. More efficient energy-dispersive detectors have either insufficient energy resolution because of the statistical limits described by Fano or too low counting rates to be of practical use. This paper updates an approach to high-resolution X-ray emission spectroscopy that uses a microcalorimeter detector array of superconducting transition-edge sensors (TESs). TES arrays are discussed and compared with conventional methods, and shown under which circumstances they are superior. It is also shown that a TES array can be integrated into a table-top time-resolved X-ray source and a soft X-ray synchrotron beamline to perform emission spectroscopy with good chemical sensitivity over a very wide range of energies.

15.
J Low Temp Phys ; 184(1-2): 374-381, 2015 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-38516044

RESUMEN

The analysis of data from x-ray microcalorimeters requires great care; their excellent intrinsic energy resolution cannot usually be achieved in practice without a statistically near-optimal pulse analysis and corrections for important systematic errors. We describe the essential parts of a pulse-analysis pipeline for data from x-ray microcalorimeters, including steps taken to reduce systematic gain variation and the unwelcome dependence of filtered pulse heights on the exact pulse-arrival time. We find these steps collectively to be essential tools for getting the best results from a microcalorimeter-based x-ray spectrometer.

16.
Rev Sci Instrum ; 84(5): 056107, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23742605

RESUMEN

Microcalorimeter sensors operated near 0.1 K can measure the energy of individual x- and gamma-ray photons with significantly more precision than conventional semiconductor technologies. Both microcalorimeter arrays and higher per pixel count rates are desirable to increase the total throughput of spectrometers based on these devices. The millisecond recovery time of gamma-ray microcalorimeters and the resulting pulse pileup are significant obstacles to high per pixel count rates. Here, we demonstrate operation of a microcalorimeter detector at elevated count rates by use of convolution filters designed to be orthogonal to the exponential tail of a preceding pulse. These filters allow operation at 50% higher count rates than conventional filters while largely preserving sensor energy resolution.

17.
Phys Rev Lett ; 110(13): 138302, 2013 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-23581383

RESUMEN

This work presents an x-ray absorption measurement by use of ionizing radiation generated by a femtosecond pulsed laser source. The spectrometer was a microcalorimetric array whose pixels are capable of accurately measuring energies of individual radiation quanta. An isotropic continuum x-ray spectrum in the few-keV range was generated from a laser plasma source with a water-jet target. X rays were transmitted through a ferrocene powder sample to the detector, whose pixels have average photon energy resolution ΔE=3.14 eV full-width-at-half-maximum at 5.9 keV. The bond distance of ferrocene was retrieved from this first hard-x-ray absorption fine-structure spectrum collected with an energy-dispersive detector. This technique will be broadly enabling for time-resolved observations of structural dynamics in photoactive systems.

18.
Rev Sci Instrum ; 83(9): 093113, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23020368

RESUMEN

Improvements in superconductor device fabrication, detector hybridization techniques, and superconducting quantum interference device readout have made square-centimeter-sized arrays of gamma-ray microcalorimeters, based on transition-edge sensors (TESs), possible. At these collecting areas, gamma microcalorimeters can utilize their unprecedented energy resolution to perform spectroscopy in a number of applications that are limited by closely-spaced spectral peaks, for example, the nondestructive analysis of nuclear materials. We have built a 256 pixel spectrometer with an average full-width-at-half-maximum energy resolution of 53 eV at 97 keV, a useable dynamic range above 400 keV, and a collecting area of 5 cm(2). We have demonstrated multiplexed readout of the full 256 pixel array with 236 of the pixels (91%) giving spectroscopic data. This is the largest multiplexed array of TES microcalorimeters to date. This paper will review the spectrometer, highlighting the instrument design, detector fabrication, readout, operation of the instrument, and data processing. Further, we describe the characterization and performance of the newest 256 pixel array.

19.
J Simul ; 5(2): 89-100, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-32226475

RESUMEN

Pandemic influenza preparedness plans strongly focus on efficient mitigation strategies including social distancing, logistics and medical response. These strategies are formed by multiple decision makers before a pandemic outbreak and during the pandemic in local communities, states and nation-wide. In this paper, we model the spread of pandemic influenza in a local community, a university, and evaluate the mitigation policies. Since the development of an appropriate vaccine requires a significant amount of time and available antiviral quantities can only cover a relatively small proportion of the population, university decision makers will first focus on non-pharmaceutical interventions. These interventions include social distancing and isolation. The disease spread is modelled as differential equations-based compartmental model. The system is simulated for multiple non-pharmaceutical interventions such as social distancing including suspending university operations, evacuating dorms and isolation of infected individuals on campus. Although the model is built based on the preparedness plan of one of the biggest universities in the world, Arizona State University, it can easily be generalized for other colleges and universities. The policies and the decisions are tested by several simulation runs and evaluations of the mitigation strategies are presented in the paper.

20.
Appl Opt ; 46(17): 3444-54, 2007 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-17514303

RESUMEN

The Atacama Cosmology Telescope is a 6 m telescope designed to map the cosmic microwave background simultaneously at 145, 215, and 280 GHz with arcminute resolution. Each frequency will have a 32 by 32 element focal plane array of transition edge sensor bolometers. The telescope and the cold reimaging optics are optimized for millimeter-wave observations with these sensitive detectors. The design of each is described.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...