Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 26(Pt 4): 1037-1044, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31274425

RESUMEN

Hard X-ray free-electron lasers (XFELs) generate intense coherent X-ray beams by passing electrons through undulators, i.e. very long periodic magnet structures, which extend over hundreds of meters. The SASE1 and SASE2 undulator systems of the European XFEL consist of 35 segments with variable-gap planar undulators which are initially tuned to precise on-axis magnetic field strengths in a magnetic measurement laboratory to keep an important quality parameter - the K-value variation from segment to segment - below a certain limit (3 × 10-4 for 12 keV photon energy). After tunnel installation only photon-based methods can determine the K-values of undulator segments with a similar accuracy. The synchrotron radiation from a single or a few segments can be spectrally filtered by a dedicated crystal monochromator (K-monochromator) and recorded with a photodiode or with an imager that provides 2D information, tuned for high sensitivity to detect low photon densities from distant single undulator segments. This instrumentation is applied for electron orbit analysis and optimization, and adjustment of individual undulators in terms of their central magnetic axis with respect to the electron beam. Single undulator segments were analysed by scanning the monochromator crystal angle and detecting the steepest slope of a photodiode signal. Alternatively, in the imaging method, an imager recorded the radiation cone of electrons passing through the undulator segment. From the spatial distribution of the radiation, the K-parameter was determined with a sufficiently high relative accuracy.

2.
Sci Data ; 6(1): 18, 2019 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-30944333

RESUMEN

We provide a detailed description of a serial femtosecond crystallography (SFX) dataset collected at the European X-ray free-electron laser facility (EuXFEL). The EuXFEL is the first high repetition rate XFEL delivering MHz X-ray pulse trains at 10 Hz. The short spacing (<1 µs) between pulses requires fast flowing microjets for sample injection and high frame rate detectors. A data set was recorded of a microcrystalline mixture of at least three different jack bean proteins (urease, concanavalin A, concanavalin B). A one megapixel Adaptive Gain Integrating Pixel Detector (AGIPD) was used which has not only a high frame rate but also a large dynamic range. This dataset is publicly available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development and for data analysis training for prospective XFEL users.


Asunto(s)
Concanavalina A/química , Proteínas de Plantas/química , Ureasa/química , Cristalización , Cristalografía por Rayos X
3.
Nat Commun ; 9(1): 3487, 2018 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-30154468

RESUMEN

X-ray free-electron lasers (XFELs) enable novel experiments because of their high peak brilliance and femtosecond pulse duration. However, non-superconducting XFELs offer repetition rates of only 10-120 Hz, placing significant demands on beam time and sample consumption. We describe serial femtosecond crystallography experiments performed at the European XFEL, the first MHz repetition rate XFEL, delivering 1.128 MHz X-ray pulse trains at 10 Hz. Given the short spacing between pulses, damage caused by shock waves launched by one XFEL pulse on sample probed by subsequent pulses is a concern. To investigate this issue, we collected data from lysozyme microcrystals, exposed to a ~15 µm XFEL beam. Under these conditions, data quality is independent of whether the first or subsequent pulses of the train were used for data collection. We also analyzed a mixture of microcrystals of jack bean proteins, from which the structure of native, magnesium-containing concanavalin A was determined.

4.
Radiat Prot Dosimetry ; 163(2): 141-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24757175

RESUMEN

The authors examine the radiation field produced in the vicinity of the main beam dump of the FERMI free-electron laser under the impact of a 1.4-GeV electron beam. Electromagnetic and neutron dose rates are calculated with the Fluka Monte Carlo code and compared with ionisation chamber and superheated drop detector measurements in various positions around the dump. Experimental data and simulation results are in good agreement with a maximum deviation of 25 % in a single location.


Asunto(s)
Electrones , Rayos Láser , Modelos Estadísticos , Aceleradores de Partículas/instrumentación , Radiometría/métodos , Simulación por Computador , Diseño de Equipo , Análisis de Falla de Equipo , Método de Montecarlo , Dosis de Radiación , Dispersión de Radiación
5.
Opt Express ; 21(19): 22728-41, 2013 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-24104160

RESUMEN

We present the experimental demonstration of a method for generating two spectrally and temporally separated pulses by an externally seeded, single-pass free-electron laser operating in the extreme-ultraviolet spectral range. Our results, collected on the FERMI@Elettra facility and confirmed by numerical simulations, demonstrate the possibility of controlling both the spectral and temporal features of the generated pulses. A free-electron laser operated in this mode becomes a suitable light source for jitter-free, two-colour pump-probe experiments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...