Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros










Intervalo de año de publicación
1.
Am J Dent ; 36(6): 274-280, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38092745

RESUMEN

PURPOSE: To evaluate the impact of simplified or multi-step polishing techniques on the roughness, color, and susceptibility to staining of different resin composites. METHODS: Discs (Ø6 mm x 2 mm) were obtained from different resin composites [nanofilled (Z350XT), suprananofilled (Estelite Omega), and nanohybrid (Forma)]. The specimens (n= 15) were submitted to a simplified protocol using abrasive discs (Sof-Lex) and spiral discs (Diacomp Plus Twist), or a multi-step protocol using abrasive discs (Sof-Lex), abrasive points (Jiffy), silicon carbide brush and felt disc with diamond pastes (Diamond Polish). The specimens were evaluated initially for roughness (Ra) and color (CIEL*a*b*, CIEDE 2000), after completing the polishing protocol, and after exposure to a coffee solution (pH= 5.01). The data were analyzed according to the variables, using generalized linear models, and the Friedman, Nemenyi, Kruskal-Wallis, Dunn, and Mann-Whitney tests (α= 0.05). RESULTS: The nanohybrid resin composite showed an increase in Ra following use of both polishing methods (P= 0.038). Both techniques promoted an increase in L* values after polishing; however, the general color changes (ΔEab and ΔE00) were greater after the multi-step polishing (P< 0.05). After immersion in coffee, the multi-step polished groups of the nanohybrid and suprananofilled resin composite showed higher L* values than the simplified polishing groups (P= 0.023), and the nanofilled resin composite showed higher ΔEab and ΔE00 values than the other resin composites, regardless of the polishing technique (P< 0.05). CLINICAL SIGNIFICANCE: The choice of the resin composite had a greater effect on roughness, color stability and susceptibility to staining than the polishing technique. However, luminosity after coffee staining was higher with the multi-step polishing technique.


Asunto(s)
Café , Pulido Dental , Pulido Dental/métodos , Propiedades de Superficie , Ensayo de Materiales , Resinas Compuestas , Diamante , Color
2.
Acta Odontol Latinoam ; 36(2): 71-77, 2023 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-37776503

RESUMEN

Based on its mechanical properties, PEEK (polyether-ether-ketone) might be useful in restorative procedures. In oral rehabilitation, its viability has been studied mainly for prostheses and dental implants. AIM: The aim of this study was to evaluate the fit accuracy of dental implant bars made of either PEEK or cobalt-chrome submitted to cycling mechanics. MATERIALS AND METHOD: This was an experimental in vitro study, where units were treated with two implants and mini-abutments, joined by cobalt-chrome or polyether-ether-ketone PEEK bars. A total 20 bars were prepared (n=10 per group) and subjected to mechanical cycling tests (1 million cycles on the distal cantilever of the bar in the vertical direction, 120N and sinusoidal loading, at a frequency of 2Hz). The fit at the abutment/implant interface was measured before and after cycling, and the counter-torque of the vertical screw of the mini abutments was measured after cycling, using a digital torquemeter. Data were analyzed by three-way ANOVA and Tukey's test at 5% significance level. RESULTS: No statistically significant interaction was found among the three factors considered (bar material, implant positioning and mechanical cycling) (p = 0.592). No significant difference was identified in the interaction between bar material and implant positioning (p = 0.321), or between implant positioning and mechanical cycling (p = 0.503). The association between bar material and mechanical cycling was statistically significant (p = 0.007), with the cobalt-chrome bar resulting in greater misfit with mechanical cycling. There was no difference in counter-torque values between groups. CONCLUSIONS: The PEEK bar provided better fit of the mini abutments to the implants, even after mechanical cycling. The counter-torque of the screws was similar in all scenarios considered.


O PEEK (Poli-éter-éter-cetona) é um material considerado para uso em procedimentos restauradores devido às suas propriedades mecânicas. Na reabilitação oral, sua viabilidade tem sido estudada principalmente para uso em próteses e implantes dentários. Objetivos: O objetivo deste estudo foi avaliar a precisão da adaptação de duas barras diferentes do tipo protocolo confeccionadas em PEEK ou Cobalto-Cromo, após serem submetidas à mecânica ciclística. Materiais e Método: As unidades experimentais foram constituídas por barras confeccionadas em Poli-ether-ether-Ketone (PEEK) e em Cobalto-Cromo (Co-Cr). Trata-se de um estudo experimental, in vitro, onde verificou-se unidades constituídas por dois implantes e mini pilares unidos com barras de Cobalto-Cromo ou PEEK. Foram confeccionados um total de 20 barras (n=10 em cada grupo) e as barras foram submetidas a ensaios de ciclagem mecânica (1 milhão de ciclos no cantilever distal da barra no sentido vertical, 120N e carregamento senoidal, a uma frequência de 2Hz). Antes e após a ciclagem realizou-se a mensuração da desadaptação na interface pilar/implante e após a ciclagem foi medido o contra-torque do parafuso vertical dos mini-pilares através de torquímetro digital TQ 8800 (LT Lutron, Taiwan). Os dados foram submetidos a ANOVA a três critérios e teste de Tukey ao nível de significância a 5%. Resultados: Constatou-se que não houve interação estatisticamente significativa entre os três fatores estudados, ou seja, entre o material da barra, o posicionamento do implante e a ciclagem mecânica (p = 0,592). Também não se identificou diferença estatística significativa da interação entre o material da barra e o posicionamento do implante (p = 0,321), nem entre o posicionamento do implante e a ciclagem mecânica (p = 0,503). Já a associação entre o material da barra e a ciclagem mecânica foi estatisticamente significativa (p = 0,007), onde a barra de Cobalto-Cromo resultou em maior desadaptação com a ciclagem mecânica. Não houve diferença nos valores dos contra-torques entre os grupos. Conclusões: Conclui-se que a barra de protocolo fabricada em PEEK proporcionou melhor adaptação dos mini pilares aos implantes mesmo após a ciclagem mecânica. Por fim, o contra-torque dos parafusos foi semelhante em todos os cenários avaliados.


Asunto(s)
Implantes Dentales , Pilares Dentales , Polietilenglicoles , Cetonas , Cobalto , Éteres , Análisis del Estrés Dental/métodos , Ensayo de Materiales
3.
Acta Odontol Latinoam ; 36(2): 86-95, 2023 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-37776505

RESUMEN

During the manufacture of ceramic restorations there is an important step of finishing and polishing and the effects of different types of these procedures on the surface characteristics of ceramics are not known for sure. AIM: To evaluate the effects of various surface treatments and immersion in coloring substances on the roughness, microhardness, and color stability of CAD-CAM monolithic ceramics. MATERIALS AND METHOD: The ceramics used were lithium disilicate reinforced with zirconium dioxide (Suprinity), lithium disilicate (E.max) or leucite (Empress). They were subjected to two surface treatments: glazing (group G) (n=20) or mechanical polishing (group P) (n=20). Then they were divided into two subgroups (n=10) to be treated with the staining substance (coffee or water). Roughness, microhardness and color were measured before and after treatment. Data were subjected to analysis of variance and multiple comparisons were performed with Tukey tests at 5% significance level. RESULTS: Roughness was lower in all tested ceramics after polishing than after glazing. Microhardness was the same for polished and glazed E.max, higher in glazed than polished Empress, and higher in polished than glazed Suprinity. Analysis of the effects of glazing and polishing on the individual ceramics showed that the ΔE2000 and ΔWID data of the E.max ceramic subjected to polishing showed greater change. Mechanical polishing is a good option for surface treatment of monolithic ceramics. CONCLUSION: Glazing was inferior and less satisfactory than polishing. Glazing generates changes that can lead to color instability.


Durante a confecção de restaurações cerâmicas existe uma importante etapa dos procedimentos de acabamento e polimento. Os efeitos de diferentes tipos desses procedimentos nas características superficiais das cerâmicas não são conhecidos com certeza. Objetivo: Avaliar os efeitos de vários tratamentos de superfície e imersão em substâncias corantes na rugosidade, microdureza e estabilidade de cor de cerâmicas monolíticas CAD-CAM. Materiais e Métodos: As cerâmicas utilizadas foram dissilicato de lítio reforçado com dióxido de zircônio (Suprinity), dissilicato de lítio (E.max) ou leucita (Empress). Foram submetidos a dois tratamentos de superfície: glazeamento (grupo G) (n=20) ou polimento mecânico (grupo P) (n=20). Em seguida, foram divididos em dois subgrupos (n=10) para serem tratados com a substância corante (café ou água). Rugosidade, microdureza e cor foram medidas antes e após o tratamento. Os dados foram submetidos à análise de variância e as comparações múltiplas foram realizadas com testes de Tukey ao nível de 5% de significância. Resultados: A rugosidade foi menor em todas as cerâmicas testadas após o polimento do que após o glazeamento. A microdureza foi a mesma para o E.max polido e vidrado, maior no Empress vidrado do que no polido, e maior no Suprinity polido do que no vidrado. A análise dos efeitos do esmaltação e polimento nas cerâmicas individuais mostrou que os dados ΔE2000 e ΔWID da cerâmica E.max submetida ao polimento apresentaram maior alteração. O polimento mecânico é uma boa opção para o tratamento superficial de cerâmicas monolíticas. Conclusão: A aplicação do glazing foi inferior e menos satisfatório que o polimento, gerando alterações que podem levar à instabilidade da cor.


Asunto(s)
Pulido Dental , Inmersión , Ensayo de Materiales , Pulido Dental/métodos , Propiedades de Superficie , Cerámica/química , Porcelana Dental/química , Diseño Asistido por Computadora , Color
4.
Am J Dent ; 36(4): 188-192, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37587029

RESUMEN

PURPOSE: To evaluate the smoothness provided by a one-step finishing and polishing system and its maintenance after hydrothermal aging and brushing of a nanofilled resin composite. METHODS: 96 samples of the nanofilled composite Filtek Z350 XT were fabricated, which, after initial average roughness (Ra) analysis, were randomly distributed into three groups, according to the selected finishing and polishing system. The multi-step systems Sof-Lex (aluminum oxide discs) and Jiffy (bullet-shaped abrasive rubbers), and the one-step system OneGloss (bullet-shaped abrasive rubber) were used. After finishing and polishing, a new Ra measurement was performed, and then half of the samples from each group were stored in artificial saliva for 12 months, while the other half underwent aging processes associating hydrothermal cycles (10,000 cycles at 5-55°C) followed by brushing (5,500 strokes), with a mid-abrasive (Crest Cavity Protection) dentifrice slurry, simulating a 12-month period in the oral cavity. Final Ra measurements were performed, and data were analyzed by generalized linear model and Tukey's test (α= 5%). RESULTS: There was interaction between finishing and polishing system and aging (P< 0.001). The one-step abrasive rubber point provided significantly higher Ra values compared to the multi-step systems, and with the discs there was higher smoothness than with the rubber point sequence. This result was maintained after 12 months in artificial saliva, but after hydrothermal cycles followed by brushing, one-step and multi-step abrasive rubber points no longer significantly differed from each other. Only for the one-step system, hydrothermal cycles followed by brushing significantly reduced Ra. CLINICAL SIGNIFICANCE: Although hydrothermal cycles followed by brushing may have increased the smoothness of nanofilled composite finished and polished with the one-step system, only the multi-step system provided a surface within the roughness threshold to avoid biofilm retention.


Asunto(s)
Caries Dental , Goma , Humanos , Biopelículas , Instrumentos Dentales , Saliva Artificial
5.
Am J Dent ; 36(4): 193-200, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37587030

RESUMEN

PURPOSE: To evaluate the effect of different varnishes on dentin permeability to erosive/abrasive challenges. METHODS: 60 superficial dentin discs were randomly allocated to six groups (n=10): Duraphat, PRG Barrier Coat, Clinpro XT, Profluorid, Fluor Protector S and untreated (control). Permeability tests were carried out: after acid conditioning, after treatment, and after abrasive/erosive challenges. The abrasive-erosive challenges were performed for 5 days (citric acid and in remineralizing saliva), as well as abrasion with toothpaste slurry (Colgate Total 12). Scanning electron microscopy (SEM) images were obtained of the dentin surfaces (5,000x) after the treatments, and after the erosive/abrasive challenges. RESULTS: Kruskal-Wallis and Dunn tests showed that all the varnishes promoted a decrease in dentin permeability directly after application, with Clinpro XT showing the highest percentage (69.52%) of dentin sealing (P= 0.0188). After the erosive/abrasive challenge, only PRG Barrier Coat varnish showed dentin sealing ability with reduced dentin permeability (42.16%) (P= 0.0014). However, none of the applied varnishes promoted a statistically significant difference in the percentage of dentin sealing, compared with the control group (P> 0.05). Clinpro XT showed a higher percentage of dentin sealing, while only PRG Barrier Coat showed reduced dentin permeability after the erosive/abrasive challenge. CLINICAL SIGNIFICANCE: Varnish containing S-PRG filler has the efficacy needed to be used as a coating material to reduce dentin permeability in situations of erosive/abrasive challenges.


Asunto(s)
Ácido Cítrico , Permeabilidad de la Dentina , Pintura , Microscopía Electrónica de Rastreo , Saliva , Pastas de Dientes , Dentina
6.
Am J Dent ; 36(4): 201-206, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37587031

RESUMEN

PURPOSE: To evaluate over time the bond strength to dentin of different resin composites (RBCs) associated with the universal adhesive system applied with self-etching or total-etching strategies. METHODS: 60 human third molars were obtained, randomly divided into experimental groups (n= 10) according to RBCs: methacrylate-based nanofilled (Z350 XT); low-viscosity Ormocer-based bulk-fill (Admira Fusion X-base Universal); or high-viscosity Ormocer-based bulk-fill composite (Admira Fusion X-tra). The adhesion procedure was performed using a universal adhesive (Futurabond U) applied in self-etching or total-etching mode. Occlusal preparations (Class I) were made, measuring 4 mm in mesiodistal length, 4 mm in depth, and 3 mm in buccolingual height. The cavities were restored considering the RBCs and adhesive strategies, and the light curing was performed using a LED unit (BluePhase) as recommended by the manufacturers. For this, the nanofilled RBCs were inserted by the oblique incremental technique while the bulk-fill RBCs were inserted in single increments. The samples were stored in water for 24 hours in an oven; to be sectioned, the sticks were randomly separated, stored in distilled water for 24 hours (immediate) or 12 months (long-term), and taken to the universal machine for a microtensile test (MPa). The fractured sticks were examined to classify the type of fracture. The results were analyzed by ANOVA and Tukey's test (α= 0.05). RESULTS: The MPa values of methacrylate-based nanofilled or high-viscosity Ormocer-based RBC were not affected by the strategy used to apply the universal adhesive system (P> 0.05). However, for the low-viscosity Ormocer-based RBC, higher values were obtained when the total-etching strategy was used compared to the self-etching mode (P< 0.05). After 12 months, when using the total-etching strategy low-viscosity Ormocer-based RBC, higher MPa values were obtained compared to the other materials (P< 0.05). CLINICAL SIGNIFICANCE: Regardless of the adhesive strategy used, the high-viscosity RBCs, whether based on methacrylate or Ormocer, showed similar adhesive behavior. Low-viscosity Ormocer-based RBC showed greater long-term bond strength associated with the universal adhesive applied in the total-etching strategy.


Asunto(s)
Resinas Compuestas , Caries Dental , Humanos , Metacrilatos , Cerámicas Modificadas Orgánicamente
7.
Acta odontol. latinoam ; 36(2): 71-77, Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1513549

RESUMEN

ABSTRACT Based on its mechanical properties, PEEK (polyether-ether-ketone) might be useful in restorative procedures. In oral rehabilitation, its viability has been studied mainly for prostheses and dental implants. Aim: The aim of this study was to evaluate the fit accuracy of dental implant bars made of either PEEK or cobalt-chrome submitted to cycling mechanics. Materials and Method: This was an experimental in vitro study, where units were treated with two implants and mini-abutments, joined by cobalt-chrome or polyether-ether-ketone PEEK bars. A total 20 bars were prepared (n=10 per group) and subjected to mechanical cycling tests (1 million cycles on the distal cantilever of the bar in the vertical direction, 120N and sinusoidal loading, at a frequency of 2Hz). The fit at the abutment/implant interface was measured before and after cycling, and the counter-torque of the vertical screw of the mini abutments was measured after cycling, using a digital torquemeter. Data were analyzed by three-way ANOVA and Tukey's test at 5% significance level. Results: No statistically significant interaction was found among the three factors considered (bar material, implant positioning and mechanical cycling) (p = 0.592). No significant difference was identified in the interaction between bar material and implant positioning (p = 0.321), or between implant positioning and mechanical cycling (p = 0.503). The association between bar material and mechanical cycling was statistically significant (p = 0.007), with the cobalt-chrome bar resulting in greater misfit with mechanical cycling. There was no difference in counter-torque values between groups. Conclusions: The PEEK bar provided better fit of the mini abutments to the implants, even after mechanical cycling. The counter-torque of the screws was similar in all scenarios considered.


RESUMO O PEEK (Poli-éter-éter-cetona) é um material considerado para uso em procedimentos restauradores devido às suas propriedades mecânicas. Na reabilitação oral, sua viabilidade tem sido estudada principalmente para uso em próteses e implantes dentários. Objetivos: O objetivo deste estudo foi avaliar a precisão da adaptação de duas barras diferentes do tipo protocolo confeccionadas em PEEK ou Cobalto-Cromo, após serem submetidas à mecânica ciclística. Materiais e Método: As unidades experimentais foram constituídas por barras confeccionadas em Poli-ether-ether-Ketone (PEEK) e em Cobalto-Cromo (Co-Cr). Trata-se de um estudo experimental, in vitro, onde verificou-se unidades constituídas por dois implantes e mini pilares unidos com barras de Cobalto-Cromo ou PEEK. Foram confeccionados um total de 20 barras (n=10 em cada grupo) e as barras foram submetidas a ensaios de ciclagem mecânica (1 milhão de ciclos no cantilever distal da barra no sentido vertical, 120N e carregamento senoidal, a uma frequência de 2Hz). Antes e após a ciclagem realizou-se a mensuração da desadaptação na interface pilar/implante e após a ciclagem foi medido o contra-torque do parafuso vertical dos mini-pilares através de torquímetro digital TQ 8800 (LT Lutron, Taiwan). Os dados foram submetidos a ANOVA a três critérios e teste de Tukey ao nível de significância a 5%. Resultados: Constatou-se que não houve interação estatisticamente significativa entre os três fatores estudados, ou seja, entre o material da barra, o posicionamento do implante e a ciclagem mecânica (p = 0,592). Também não se identificou diferença estatística significativa da interação entre o material da barra e o posicionamento do implante (p = 0,321), nem entre o posicionamento do implante e a ciclagem mecânica (p = 0,503). Já a associação entre o material da barra e a ciclagem mecânica foi estatisticamente significativa (p = 0,007), onde a barra de Cobalto-Cromo resultou em maior desadaptação com a ciclagem mecânica. Não houve diferença nos valores dos contra-torques entre os grupos. Conclusões: Conclui-se que a barra de protocolo fabricada em PEEK proporcionou melhor adaptação dos mini pilares aos implantes mesmo após a ciclagem mecânica. Por fim, o contra-torque dos parafusos foi semelhante em todos os cenários avaliados.

8.
Acta odontol. latinoam ; 36(2): 86-95, Aug. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1513551

RESUMEN

ABSTRACT During the manufacture of ceramic restorations there is an important step of finishing and polishing and the effects of different types of these procedures on the surface characteristics of ceramics are not known for sure. Aim: To evaluate the effects of various surface treatments and immersion in coloring substances on the roughness, microhardness, and color stability of CAD-CAM monolithic ceramics. Materials and Method: The ceramics used were lithium disilicate reinforced with zirconium dioxide (Suprinity), lithium disilicate (E.max) or leucite (Empress). They were subjected to two surface treatments: glazing (group G) (n=20) or mechanical polishing (group P) (n=20). Then they were divided into two subgroups (n=10) to be treated with the staining substance (coffee or water). Roughness, microhardness and color were measured before and after treatment. Data were subjected to analysis of variance and multiple comparisons were performed with Tukey tests at 5% significance level. Results: Roughness was lower in all tested ceramics after polishing than after glazing. Microhardness was the same for polished and glazed E.max, higher in glazed than polished Empress, and higher in polished than glazed Suprinity. Analysis of the effects of glazing and polishing on the individual ceramics showed that the ΔE2000 and ΔWID data of the E.max ceramic subjected to polishing showed greater change. Mechanical polishing is a good option for surface treatment of monolithic ceramics. Conclusion: Glazing was inferior and less satisfactory than polishing. Glazing generates changes that can lead to color instability.


RESUMO Durante a confecção de restaurações cerâmicas existe uma importante etapa dos procedimentos de acabamento e polimento. Os efeitos de diferentes tipos desses procedimentos nas características superficiais das cerâmicas não são conhecidos com certeza. Objetivo: Avaliar os efeitos de vários tratamentos de superfície e imersão em substâncias corantes na rugosidade, microdureza e estabilidade de cor de cerâmicas monolíticas CAD-CAM. Materiais e Métodos: As cerâmicas utilizadas foram dissilicato de lítio reforçado com dióxido de zircônio (Suprinity), dissilicato de lítio (E.max) ou leucita (Empress). Foram submetidos a dois tratamentos de superfície: glazeamento (grupo G) (n=20) ou polimento mecânico (grupo P) (n=20). Em seguida, foram divididos em dois subgrupos (n=10) para serem tratados com a substância corante (café ou água). Rugosidade, microdureza e cor foram medidas antes e após o tratamento. Os dados foram submetidos à análise de variância e as comparações múltiplas foram realizadas com testes de Tukey ao nível de 5% de significância. Resultados: A rugosidade foi menor em todas as cerâmicas testadas após o polimento do que após o glazeamento. A microdureza foi a mesma para o E.max polido e vidrado, maior no Empress vidrado do que no polido, e maior no Suprinity polido do que no vidrado. A análise dos efeitos do esmaltação e polimento nas cerâmicas individuais mostrou que os dados ΔE2000 e ΔWID da cerâmica E.max submetida ao polimento apresentaram maior alteração. O polimento mecânico é uma boa opção para o tratamento superficial de cerâmicas monolíticas. Conclusão: A aplicação do glazing foi inferior e menos satisfatório que o polimento, gerando alterações que podem levar à instabilidade da cor.

9.
Acta odontol. latinoam ; 35(3): 206-213, Dec. 2022. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1419947

RESUMEN

ABSTRACT Aim: This study evaluated the influence of chitosan added to a universal adhesive system used in totaletch (TE) or self-etch (SE) mode on dentin permeability, and on the micromorphology of the adhesive layer. Materials and Method: Dentin discs were obtained from human third molars and randomly distributed according to bonding strategy (TE or SE), and to whether or not 1% chitosan (C) was added to a universal adhesive system (Single Bond Universal/3M ESPE), to create the following groups (n=10): TE, TEC, SE, and SEC. Dentin permeability was measured at baseline and after application of dentin treatments. The surface of the adhesive layer (AL) and the dentin adjacent to the AL were examined under a scanning electron microscope. Results: There were no significant differences in permeability percentage between the groups with and without C (TE and SE versus TEC and SEC) (p>0.05; Mann Whitney test). Dentin permeability was lower when the adhesive system was applied in the SE mode, regardless of the addition of C. The micromorphology of the AL surface showed irregularities, and a greater degree of porosity, when the adhesive system was applied in the SE mode, regardless of chitosan addition. There was a greater depth of penetration of the adhesives into the dentin adjacent to the AL in both the TE and TEC groups. Chitosan added to the adhesive system did not influence dentin permeability. Conclusions: The self-etch strategy led to lower dentin permeability, and to more irregularities on the surface of the adhesive layer.


RESUMO Objetivo: Este estudo avaliou a influência da quitosana adicionada a um sistema adesivo universal usado no modo total-etch (TE) ou self-etch (SE) na permeabilidade dentinária e na micromorfologia da camada adesiva. Materiais e método: Discos de dentina foram obtidos de terceiros molares humanos e distribuídos aleatoriamente de acordo com a estratégia de união (TE ou SE), e para incorporação ou não de quitosana a 1% (Q) em um sistema adesivo universal (Single Bond Universal/3M ESPE), para obter os seguintes grupos (n=10): TE, TEQ, SE e SEQ. A permeabilidade da dentina foi medida no início e após a aplicação dos tratamentos de dentina. A superfície da camada adesiva (CA) e a dentina adjacente à CA foram examinadas em microscópio eletrônico de varredura. Resultados: Não houve diferenças significativas no percentual de permeabilidade entre os grupos com e sem Q (TE e SE versus TEQ e SEQ) (p>0,05; teste de Mann Whitney). Houve um menor percentual de permeabilidade dentinária quando o sistema adesivo foi aplicado no modo SE, independentemente da incorporação de Q. A micromorfologia da superfície da CA apresentou irregularidades e maior grau de porosidade quando o sistema adesivo foi aplicado no modo SE, independentemente da adição de Q. Houve maior profundidade de penetração dos adesivos na dentina adjacente à CA nos grupos TE e TEQ. A quitosana adicionada ao sistema adesivo não influenciou a permeabilidade dentinária. Conclusões: A estratégia autocondicionante levo

10.
Acta Odontol Latinoam ; 35(2): 90-97, 2022 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-36260939

RESUMEN

Melatonin (MLT) is a hormone responsible for regulating several physiological processes. It has been shown that MLT can be an important mediator in bone formation and stimulation, promoting osteoblast differentiation. In clinical practice, in tissue regeneration procedures, it is necessary to use membranes or barriers, associated with biomaterials, or not. The aim of this in vitro study was to assess the effect of melatonin on the activity of osteoblastic cells, associated, or not, with a resorbable collagen membrane (Bio-Gideä). For this, mice-derived pre-osteoblastic cells MC3T3 obtained from the ATCC (American Type Culture Collection) were used. Cultured cells were subject to the following treatments: MLT with a concentration of 1mM, a Bio-Gideä membrane and a membrane associated with MLT (Bio-Gideä + MLT). Proliferation and cell viability assays and protein lysate (ELISA test) quantification for the BMP-2 protein were carried out, in periods of 72 hours, 7 days and 10 days. After analyzing the data (one-way ANOVA, alpha=5%) it was observed that when MLT was used in isolation, there was an increase in cell proliferation and viability in osteoblastic cells (p<0.05). But, when MLT was associated with resorbable membranes, there was an inverse behavior, both in terms of proliferation and viability (p<0.05). In the case of the ELISA test, no secretion of BMP-2 was detected in any of the analyzed groups. It is concluded that MLT has a stimulatory effect on osteoblasts, but, when associated with Bio-Gideä resorbable membranes, it does not show any viable action in osteoblastic cell stimulation.


A melatonina (MLT) é um hormônio responsável pela regulação de diversos processos fisiológicos no nosso organismo. Tem sido demonstrado que a melatonina possa ser um importante mediador na formação e estimulação óssea, promovendo a diferenciação dos osteoblastos. Clinicamente, para o procedimento de regeneração tecidual, faz-se necessário a utilização de membranas ou barreiras, associadas ou não a biomateriais. Assim, o objetivo deste estudo in vitro foi avaliar o efeito da melatonina na atividade de células osteoblásticas, associada ou não a uma membrana de colágeno reabsorvível (Bio-Gide®). Para isto foram utilizadas células pré-osteoblásticas MC3T3 do ATCC (American Type Culture Collection), de camundongos. As células em cultura foram submetidas aos seguintes tratamentos: MLT na concentração de 1mM, membrana Bio Gide® e membrana associada à MLT (Bio-Gide® + MLT). Foram realizados os ensaios de proliferação e viabilidade celular e quantificação do lisado proteico (teste ELISA), para a proteína BMP-2, nos períodos de 72 horas, 7 e 10 dias. Após a análise dos dados (ANOVA um critério, alfa=5%) pode-se observar que a MLT quando utilizada sozinha, resultou em um aumento na proliferação e viabilidade celular nas células osteoblásticas (p<0,05). Entretanto, quando a MLT foi associada à membrana reabsorvível foi observado um comportamento inverso, tanto na proliferação quanto na viabilidade (p<0,05). Para o teste ELISA realizado, não houve secreção detectável de BMP-2 para nenhum grupo analisado. Conclui-se que a melatonina possui uma ação estimuladora nos osteoblastos, mas quando associada à membrana reabsorvível Bio-Gide®, não demonstra uma ação viável na estimulação de células osteoblásticas.


Asunto(s)
Melatonina , Ratones , Animales , Melatonina/farmacología , Osteoblastos , Colágeno/metabolismo , Colágeno/farmacología , Materiales Biocompatibles/metabolismo , Materiales Biocompatibles/farmacología
11.
Acta Odontol Latinoam ; 35(2): 111-119, 2022 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-36260942

RESUMEN

Acidic conditions can cause hydrolysis and accelerate degradation of resin composites (RCs). Since there are limited and controversial data on the effect of acids on bulk-fill RCs, this study assessed the surface roughness (SR) and flexural strength (FS) of these RCs under simulated carious and erosion conditions. Bars of Filtek Bulk Fill (FBF, 3M/ESPE), X-tra fil (XTF, Voco), Tetric N-Ceram Bulk Fill (TBF, Ivoclar/Vivadent), and Aura Bulk Fill (ABF, SDI) and a conventional RC [Filtek Z350XT (FZ, 3M/ESPE)] were allocated (n=15) to undergo caries or erosion conditions. The control group was kept in artificial saliva (AS). The bars were evaluated for SR change (final-baseline) and for three-point FS. Data were analyzed using ANOVA and Tukey's test. At the baseline (p <0.001), the SR of RCs ranked as follows: (TBF = XTF) < FBF (none differed from FZ) < ABF. The interplay between RCs and conditions affected SR change (p = 0.025). While after storage in AS, there was no difference among RCs, following carious and erosive conditions, ABF showed higher SR change. For FS (p <0.001), XTF > (FBF = FZ) > (TBF = FZ) > ABF, with no difference among control, carious and erosive conditions (p = 0.148). Depending on the restorative bulk-fill RCs, carious and erosive conditions roughen the surface but do not affect the FS of these materials.


Condições acídicas podem causar hidrólise e acelerar a degradação de resinas compostas (RCs). Como há dados limitados e controversos sobre os efeitos de ácidos sobre RCs bulk-fill, este estudo avaliou a rugosidade de superfície (RS) e a resistência flexural (RF) dessas RCs sob condições simuladas de cárie e erosão. Barras de Filtek Bulk Fill (FBF, 3M/ESPE), X-tra fil (XTF, Voco), Tetric N-Ceram Bulk Fill (TBF, Ivoclar/Vivadent) e Aura Bulk Fill (ABF, SDI) e de uma RC convencional [Filtek Z350XT (FZ, 3M/ESPE)] foram alocadas (n=15) para estarem sob condições cariogênicas ou erosivas. O grupo controle foi mantido em saliva artificial saliva (SA). As barras foram avaliadas quanto à alteração de RS (final-inicial) e à RF de três pontos. Os dados foram analisados utilizando ANOVA e teste de Tukey. Inicialmente (p <0,001) a RS das RCs foi a seguinte: (TBF = XTF) < FBF (nenhuma diferiu de FZ)< ABF. A interação entre as RCs e as condições acídicas influenciou a alteração de RS (p = 0,025). Após armazenamento na SA, não houve diferença entre as RCs, enquanto após condições cariogênicas e erosivas a ABF mostrou a maior alteração de RS. Para FS (p < 0,001), XTF > (FBF = FZ) > (TBF = FZ) >ABF, sem diferença entre controle e condições cariogênicas e erosivas (p = 0,148). Dependendo da RC bulk-fill restauradora, condições cariogênicas e erosivas aumentam a RS, mas não alteram a RF desses materiais.


Asunto(s)
Resinas Compuestas , Caries Dental , Humanos , Saliva Artificial , Caries Dental/terapia , Ensayo de Materiales
12.
Acta odontol. latinoam ; 35(2): 90-97, Sept. 2022. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1403029

RESUMEN

ABSTRACT Melatonin (MLT) is a hormone responsible for regulating several physiological processes. It has been shown that MLT can be an important mediator in bone formation and stimulation, promoting osteoblast differentiation. In clinical practice, in tissue regeneration procedures, it is necessary to use membranes or barriers, associated with biomaterials, or not. The aim of this in vitro study was to assess the effect of melatonin on the activity of osteoblastic cells, associated, or not, with a resorbable collagen membrane (Bio-Gideä). For this, mice-derived pre-osteoblastic cells MC3T3 obtained from the ATCC (American Type Culture Collection) were used. Cultured cells were subject to the following treatments: MLT with a concentration of 1mM, a Bio-Gideä membrane and a membrane associated with MLT (Bio-Gideä + MLT). Proliferation and cell viability assays and protein lysate (ELISA test) quantification for the BMP-2 protein were carried out, in periods of 72 hours, 7 days and 10 days. After analyzing the data (one-way ANOVA, alpha=5%) it was observed that when MLT was used in isolation, there was an increase in cell proliferation and viability in osteoblastic cells (p<0.05). But, when MLT was associated with resorbable membranes, there was an inverse behavior, both in terms of proliferation and viability (p<0.05). In the case of the ELISA test, no secretion of BMP-2 was detected in any of the analyzed groups. It is concluded that MLT has a stimulatory effect on osteoblasts, but, when associated with Bio-Gideä resorbable membranes, it does not show any viable action in osteoblastic cell stimulation.


RESUMO A melatonina (MLT) é um hormônio responsável pela regulação de diversos processos fisiológicos no nosso organismo. Tem sido demonstrado que a melatonina possa ser um importante mediador na formação e estimulação óssea, promovendo a diferenciação dos osteoblastos. Clinicamente, para o procedimento de regeneração tecidual, faz-se necessário a utilização de membranas ou barreiras, associadas ou não a biomateriais. Assim, o objetivo deste estudo in vitro foi avaliar o efeito da melatonina na atividade de células osteoblásticas, associada ou não a uma membrana de colágeno reabsorvível (Bio-Gide®). Para isto foram utilizadas células pré-osteoblásticas MC3T3 do ATCC (American Type Culture Collection), de camundongos. As células em cultura foram submetidas aos seguintes tratamentos: MLT na concentração de 1mM, membrana Bio Gide® e membrana associada à MLT (Bio-Gide® + MLT). Foram realizados os ensaios de proliferação e viabilidade celular e quantificação do lisado proteico (teste ELISA), para a proteína BMP-2, nos períodos de 72 horas, 7 e 10 dias. Após a análise dos dados (ANOVA um critério, alfa=5%) pode-se observar que a MLT quando utilizada sozinha, resultou em um aumento na proliferação e viabilidade celular nas células osteoblásticas (p<0,05). Entretanto, quando a MLT foi associada à membrana reabsorvível foi observado um comportamento inverso, tanto na proliferação quanto na viabilidade (p<0,05). Para o teste ELISA realizado, não houve secreção detectável de BMP-2 para nenhum grupo analisado. Conclui-se que a melatonina possui uma ação estimuladora nos osteoblastos, mas quando associada à membrana reabsorvível Bio-Gide®, não demonstra uma ação viável na estimulação de células osteoblásticas.

13.
Acta odontol. latinoam ; 35(2): 111-119, Sept. 2022. graf
Artículo en Inglés | LILACS-Express | LILACS | ID: biblio-1403032

RESUMEN

ABSTRACT Acidic conditions can cause hydrolysis and accelerate degradation of resin composites (RCs). Since there are limited and controversial data on the effect of acids on bulk-fill RCs, this study assessed the surface roughness (SR) and flexural strength (FS) of these RCs under simulated carious and erosion conditions. Bars of Filtek Bulk Fill (FBF, 3M/ESPE), X-tra fil (XTF, Voco), Tetric N-Ceram Bulk Fill (TBF, Ivoclar/Vivadent), and Aura Bulk Fill (ABF, SDI) and a conventional RC [Filtek Z350XT (FZ, 3M/ESPE)] were allocated (n=15) to undergo caries or erosion conditions. The control group was kept in artificial saliva (AS). The bars were evaluated for SR change (final-baseline) and for three-point FS. Data were analyzed using ANOVA and Tukey's test. At the baseline (p <0.001), the SR of RCs ranked as follows: (TBF = XTF) < FBF (none differed from FZ) < ABF. The interplay between RCs and conditions affected SR change (p = 0.025). While after storage in AS, there was no difference among RCs, following carious and erosive conditions, ABF showed higher SR change. For FS (p <0.001), XTF > (FBF = FZ) > (TBF = FZ) > ABF, with no difference among control, carious and erosive conditions (p = 0.148). Depending on the restorative bulk-fill RCs, carious and erosive conditions roughen the surface but do not affect the FS of these materials.


RESUMO Condições acídicas podem causar hidrólise e acelerar a degradação de resinas compostas (RCs). Como há dados limitados e controversos sobre os efeitos de ácidos sobre RCs bulk-fill, este estudo avaliou a rugosidade de superfície (RS) e a resistência flexural (RF) dessas RCs sob condições simuladas de cárie e erosão. Barras de Filtek Bulk Fill (FBF, 3M/ESPE), X-tra fil (XTF, Voco), Tetric N-Ceram Bulk Fill (TBF, Ivoclar/Vivadent) e Aura Bulk Fill (ABF, SDI) e de uma RC convencional [Filtek Z350XT (FZ, 3M/ESPE)] foram alocadas (n=15) para estarem sob condições cariogênicas ou erosivas. O grupo controle foi mantido em saliva artificial saliva (SA). As barras foram avaliadas quanto à alteração de RS (final-inicial) e à RF de três pontos. Os dados foram analisados utilizando ANOVA e teste de Tukey. Inicialmente (p <0,001) a RS das RCs foi a seguinte: (TBF = XTF) < FBF (nenhuma diferiu de FZ)< ABF. A interação entre as RCs e as condições acídicas influenciou a alteração de RS (p = 0,025). Após armazenamento na SA, não houve diferença entre as RCs, enquanto após condições cariogênicas e erosivas a ABF mostrou a maior alteração de RS. Para FS (p < 0,001), XTF > (FBF = FZ) > (TBF = FZ) >ABF, sem diferença entre controle e condições cariogênicas e erosivas (p = 0,148). Dependendo da RC bulk-fill restauradora, condições cariogênicas e erosivas aumentam a RS, mas não alteram a RF desses materiais.

14.
Acta Odontol Latinoam ; 35(3): 206-213, 2022 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-36748739

RESUMEN

AIM: This study evaluated the influence of chitosan added to a universal adhesive system used in totaletch (TE) or self-etch (SE) mode on dentin permeability, and on the micromorphology of the adhesive layer. MATERIALS AND METHOD: Dentin discs were obtained from human third molars and randomly distributed according to bonding strategy (TE or SE), and to whether or not 1% chitosan (C) was added to a universal adhesive system (Single Bond Universal/3M ESPE), to create the following groups (n=10): TE, TEC, SE, and SEC. Dentin permeability was measured at baseline and after application of dentin treatments. The surface of the adhesive layer (AL) and the dentin adjacent to the AL were examined under a scanning electron microscope. RESULTS: There were no significant differences in permeability percentage between the groups with and without C (TE and SE versus TEC and SEC) (p>0.05; Mann Whitney test). Dentin permeability was lower when the adhesive system was applied in the SE mode, regardless of the addition of C. The micromorphology of the AL surface showed irregularities, and a greater degree of porosity, when the adhesive system was applied in the SE mode, regardless of chitosan addition. There was a greater depth of penetration of the adhesives into the dentin adjacent to the AL in both the TE and TEC groups. Chitosan added to the adhesive system did not influence dentin permeability. CONCLUSIONS: The self-etch strategy led to lower dentin permeability, and to more irregularities on the surface of the adhesive layer.


OBJETIVO: Este estudo avaliou a influência da quitosana adicionada a um sistema adesivo universal usado no modo total-etch (TE) ou self-etch (SE) na permeabilidade dentinária e na micromorfologia da camada adesiva. Materiais e método: Discos de dentina foram obtidos de terceiros molares humanos e distribuídos aleatoriamente de acordo com a estratégia de união (TE ou SE), e para incorporação ou não de quitosana a 1% (Q) em um sistema adesivo universal (Single Bond Universal/3M ESPE), para obter os seguintes grupos (n=10): TE, TEQ, SE e SEQ. A permeabilidade da dentina foi medida no início e após a aplicação dos tratamentos de dentina. A superfície da camada adesiva (CA) e a dentina adjacente à CA foram examinadas em microscópio eletrônico de varredura. RESULTADOS: Não houve diferenças significativas no percentual de permeabilidade entre os grupos com e sem Q (TE e SE versus TEQ e SEQ) (p>0,05; teste de Mann Whitney). Houve um menor percentual de permeabilidade dentinária quando o sistema adesivo foi aplicado no modo SE, independentemente da incorporação de Q. A micromorfologia da superfície da CA apresentou irregularidades e maior grau de porosidade quando o sistema adesivo foi aplicado no modo SE, independentemente da adição de Q. Houve maior profundidade de penetração dos adesivos na dentina adjacente à CA nos grupos TE e TEQ. A quitosana adicionada ao sistema adesivo não influenciou a permeabilidade dentinária. Conclusões: A estratégia autocondicionante levou a uma menor permeabilidade dentinária e a mais irregularidades na superfície da camada adesiva.


Asunto(s)
Quitosano , Recubrimiento Dental Adhesivo , Humanos , Quitosano/farmacología , Resinas Compuestas/química , Cementos Dentales , Dentina , Permeabilidad de la Dentina , Recubrimientos Dentinarios/farmacología , Recubrimientos Dentinarios/química , Ensayo de Materiales , Cementos de Resina/química , Resistencia a la Tracción
15.
J Clin Exp Dent ; 13(10): e1030-e1037, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34667499

RESUMEN

BACKGROUND: To evaluate the microshear bond strength (µ-SBS) between resin-based cements and core build-up materials after water storage. MATERIAL AND METHODS: Cylinders (1x1 mm) of conventional dual-cure resin cement (RelyX ARC, 3M ESPE), universal dual-cure resin cement (RelyX Ultimate, 3M ESPE) or self-adhesive resin cement (RelyX U200, 3M ESPE) were adhered to disks (6x2 mm) made with commercial core build-up materials (Bis-Core, Bisco or LuxaCore Z, DMG) or conventional nanocomposite resin (Filtek Z350 XT, 3M ESPE). The specimens (n=10) were submitted to µ-SBS test using a universal testing machine and fracture pattern analysis at 48 hours or after 9 months of water storage. The data were evaluated by three-way ANOVA for repeated measures and Tukey's test (α=0.05). RESULTS: After 48 hours, regardless of the resin-based cement used, the µ-SBS to the conventional resin composite (Filtek Z350 XT) was greater compared to other materials. However, after 9 months, there was a statistically significant decrease in µ-SBS values between the conventional resin composite and evaluated luting agents. The µ-SBS values of core build-up commercial materials (Bis-Core and LuxaCore Z) did not change over time. Regardless of the composite used and storage time, there was no statistically significant difference between the resin-based cements. After 48 h, the most prevalent failure was mixed for all groups. However, after 9 months, the core build-up materials showed a predominantly mixed fracture pattern whereas the resin composite presented an adhesive pattern. CONCLUSIONS: Commercial core build-up materials achieved stable bonding performance with resin-based cements over time. Key words:Composite resins, resin cement, dental restoration failure.

16.
Acta Odontol Latinoam ; 34(2): 173-182, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-34570866

RESUMEN

The aim of this study was to compare low- and high-viscosity bulk-fill composites for Knoop microhardness (KHN), microtensile bond strength (MTBS) to dentin in occlusal cavities, and fracture strength (FS) in molars with mesialocclusal- distal restoration. Disk-shaped samples with different thicknesses (2 or 4 mm) of low-viscosity (SDR Flow, Dentsply) and high-viscosity bulk-fill composites (Filtek BulkFill, 3M ESPE; and Tetric-N Ceram Bulk Fill, Ivoclar Vivadent) were prepared for top and bottom KHN analysis (n=10). MTBS to dentin and fracture pattern was evaluated in human molars with occlusal cavities restored with (n=10): conventional nanocomposite (Z350XT, 3M ESPE), low-viscosity (Filtek Bulk-fill Flow, 3M ESPE) or high-viscosity bulk-fill composites (Filtek BulkFill). The FS and fracture pattern of human molar with mesial-occlusal-distal restorations submitted or not to thermomechanical cycling were investigated (n=10) using: intact tooth (control), and restoration based on conventional microhybrid composite (Z250, 3M ESPE), low-viscosity (SDR Flow) or high-viscosity bulk-fill composites (Filtek BulkFill). The data were submitted to split-plot ANOVA (KHN), one-way ANOVA (MTBS), two-way ANOVA (FS) followed by Tukey's test (α=0.05). For KHN, there was no significant difference for the resin composites between the top and bottom. For MTBS, no significant differences among the materials were detected; however, the low-viscosity composite presented lower frequency of adhesive failures. For FS, there was no significant difference between composites and intact tooth regardless of thermomechanical cycling. Low- and high-viscosity bulk-fill composites have comparable microhardness and microtensile bond strength when used in occlusal restorations. Likewise, the bulk-fill composites present similar fracture strength in molars with mesio-occlusal-distal restorations.


O objetivo deste estudo foi comparar resinas compostas bulk- -fill de baixa e alta viscosidade quanto à microdureza Knoop (KHN), resistência de união a microtração (MTBS) em cavidades oclusais e carga à fratura (FS) em molares com restauração mesio-oclusal-distal. Amostras em forma de disco com diferentes espessuras (2 ou 4 mm) de resinas bulk-fill de baixa viscosidade (SDR Flow, Dentsply) e alta viscosidade (Filtek BulkFill, 3M ESPE; e Tetric-N Ceram Bulk Fill, Ivoclar Vivadent) foram obtidas para análise de KHN no topo e na base (n = 10). A MTBS em dentina e o padrão de fratura foram avaliados em molares humanos com cavidades oclusais restauradas com (n = 10): resina composta nanoparticulada convencional (Z350XT, 3M ESPE), resinas bulk-fill de baixa viscosidade (Filtek Bulk-fill Flow, 3M ESPE) ou alta viscosidade (Filtek BulkFill). Foram investigados a FS e o padrão de fratura de molares humanos em restaurações mesial-ocluso-distais sub metidas ou não à ciclagem termomecânica (n = 10), sendo: dente íntegro (controle), e restaurações baseadas em resina composta microhíbrida convencional (Z250, 3M ESPE); resinas bulk-fill de baixa viscosidade (SDR Flow) ou alta viscosidade (Filtek BulkFill). Os dados foram submetidos a split-plot ANOVA (KHN), one-way ANOVA (MTBS), two-way ANOVA (FS) seguidos do teste de Tukey (α = 0,05). Para KHN, não houve diferença significativa entre o topo e a base para as resinas compostas. Para MTBS, não foram detectadas diferenças significativas entre os materiais; entretanto, a resina bulk-fill de baixa viscosidade apresentou menor frequência de falhas adesivas. Para FS, não houve diferença significativa entre os materiais e o dente íntegro, independentemente da ciclagem termomecânica. As resinas bulk-fill de baixa e alta viscosidade têm microdureza e resistência à microtração comparáveis quando usados em restaurações oclusais. Da mesma forma, as resinas bulk-fill apresentam resistência à fratura semelhante em molares com restaurações mesio-oclusal-distais.


Asunto(s)
Resinas Compuestas , Resistencia Flexional , Humanos , Ensayo de Materiales , Diente Molar , Viscosidad
17.
Am J Dent ; 34(1): 10-16, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33544983

RESUMEN

PURPOSE: To conduct a clinical evaluation of calcium lactate and sodium fluoride mouthrinses in reducing sensitivity and efficacy of color change during in-office bleaching. METHODS: 75 participants were selected and divided into three groups (n= 25), according to the type of desensitizing treatment tested: calcium lactate mouthrinse prior to sodium fluoride mouthrinse before each bleaching session; daily mouthrinse with sodium fluoride; control (absence of mouthrinse). Each mouthrinse was used for 1 minute. Bleaching was performed following the same protocol in all groups, with 40% hydrogen peroxide (Opalescence Boost), in three 40-minute sessions, with a 48-hour interval between sessions. Clinical parameters such as sensitivity, gingival irritation and mouthrinse acceptability were assessed using Visual Analogue Scale (VAS) and clinical examination at two timepoints: baseline (before any treatment) and 48 hours after the end of treatment. The color was evaluated with a spectrophotometer (VITA Classical scale guide, 3D Master guide and CIEL*a*b*). The data were analyzed by generalized linear models and by one-way ANOVA. RESULTS: There was significant color change in all groups according to the VITA Classical scale guide (P< 0.001). There was no significant difference among the groups for ΔL*, Δa*, Δb* and ΔE over time (P> 0.05). The control group presented a significant increase in sensitivity (P= 0.008). The other groups showed no significant difference between initial and final timepoints (P> 0.05). No symptoms of gingival irritation were observed in any of the groups evaluated. All desensitizing treatments presented high acceptability. Bleaching treatment was effective, regardless of association with desensitizing treatments. No treatment prevented bleaching sensitivity, but the absence of a combined desensitizing treatment led to increased sensitivity. CLINICAL SIGNIFICANCE: Although bleaching sensitivity during in-office bleaching treatment cannot be avoided, daily fluoridated mouthrinse or calcium lactate used prior to fluoridated mouthrinse prevented its increase.


Asunto(s)
Sensibilidad de la Dentina , Blanqueadores Dentales , Blanqueamiento de Dientes , Compuestos de Calcio , Color , Sensibilidad de la Dentina/inducido químicamente , Sensibilidad de la Dentina/prevención & control , Fluoruros , Humanos , Peróxido de Hidrógeno , Lactatos , Blanqueadores Dentales/efectos adversos , Resultado del Tratamiento
18.
Acta Odontol Latinoam ; 33(2): 59-68, 2020 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-32920607

RESUMEN

The aim of this in vitro study was to evaluate the effect of bleaching protocols on the surface roughness (Ra), color change and surface micromorphology of a low-viscosity bulk-fill composite (Filtek Bulk Fill Flow, 3M ESPE), a highviscosity bulk-fill composite (Filtek Bulk Fill, 3M ESPE) and a conventional nanoparticulate composite resin (control) (Filtek Z350 XT, 3M ESPE). Forty samples of each composite (disks 5 mm in diameter and 2 mm thick) were randomly divided into four groups (n=10), according to bleaching protocol: a) 10% carbamide peroxide gel (Opalescence, Ultradent Products) (2 h/ day, for 14 days); b) 40% hydrogen peroxide gel (Opalescence Boost, Ultradent Products) (three bleaching sessions, once a week, 45 min/session); c) whitening rinse (Listerine Whitening Extreme, Johnson & Johnson) (2 min/day, for 14 days); and d) distilled water (control). The samples were submitted to triplicate readings (Ra and color [CIELAB parameters]) before and after contact with bleaching protocols. Micromorphology was analyzed in a scanning electron microscope (SEM). Ra and color parameters (ΔL, Δa, Δb and ΔE) were analyzed by generalized linear models (α=0.05). The Ra of the high-viscosity bulk-fill was significantly higher than that of the other composites (p<0.05). Ra increased significantly (p<0.05) and surface became more irregular (SEM analysis) in all the composite resins, regardless of the bleaching protocol (p<0.05). The high-viscosity bulk-fill composite resin group had significantly lower ΔE (p<0.05) than the nanoparticulate composite resin group immersed in distilled water. It was concluded that the characteristics of each resin significantly influenced the Ra more than the bleaching protocol. The high-viscosity bulk-fill resin presented minor color change.


Este estudo in vitro teve objetivo de avaliar o efeito de protocolos clareadores sobre a rugosidade de superfície (Ra), alteração de cor e micromorfologia de resina bulk-fill de baixa viscosidade (Filtek Bulk Fill Flow, 3M ESPE), alta viscosidade (Filtek Bulk Fill, 3M ESPE) e de uma resina composta nanoparticulada (controle) (Filtek Z350 XT, 3M ESPE). Quarenta amostras de cada resin composta (discos de 5 mm de diâmetro e 2 mm de espessura) foram aleatoriamente divididas em quatro grupos , de acordo com protocolo clareador (n=10): a) Gel de peróxido de carbamida (Opalescence, Ultradent Products) (2 horas/dia, por 14 dias); b) Gel de peróxido de hidrogênio (Opalescence Boost, Ultradent Products) (3 sessões de clareamento, uma por semana, 45 min/sessão); enxaguatório clareador (Listerine Whitening Extreme, Johnson & Johnson) (2 min/dia, por 14 dias); d) água destilada (controle). As amostras foram submetidas a leituras, em triplicata (Ra e cor (parâmetros CIELab) antes e depois do contato com os protocolos clareadores. A micromorfologia de superfície foi conduzida em microscópio eletrônico de varredura (MEV). Ra e parâmetros de cor (ΔL, Δa, Δb e ΔE) foram analisados por modelos lineares generalizados (α=0.05). A Ra da resina bulk-fill de alta viscosidade foi significantemente superior do que para os outros compósitos (p<0.05). A Ra aumentou significantemente (p<0.05) e a superfície ficou mais irregular (MEV) para todos os compósitos, independente do protocolo clareador (p<0,05). A resina bulk-fill de alta viscosidade obteve menor ΔE (p<0.05) do que a resina composta nanoparticulada, imersa em água destilada. Pode-se concluir que as características de cada resina composta influenciaram de forma mais significativa a Ra do que o protocolo clareador. A resina bulk fill de alta viscosidade apresentou menor alteração de cor.


Asunto(s)
Resinas Compuestas/química , Peróxido de Hidrógeno/química , Blanqueadores Dentales/química , Blanqueamiento de Dientes/métodos , Decoloración de Dientes/tratamiento farmacológico , Viscosidad/efectos de los fármacos , Color , Humanos , Ensayo de Materiales
19.
Acta odontol. latinoam ; 33(2): 59-68, Sept. 2020. graf
Artículo en Inglés | LILACS | ID: biblio-1130735

RESUMEN

ABSTRACT The aim of this in vitro study was to evaluate the effect of bleaching protocols on the surface roughness (Ra), color change and surface micromorphology of a low-viscosity bulk-fill composite (Filtek Bulk Fill Flow, 3M ESPE), a highviscosity bulk-fill composite (Filtek Bulk Fill, 3M ESPE) and a conventional nanoparticulate composite resin (control) (Filtek Z350 XT, 3M ESPE). Forty samples of each composite (disks 5 mm in diameter and 2 mm thick) were randomly divided into four groups (n=10), according to bleaching protocol: a) 10% carbamide peroxide gel (Opalescence, Ultradent Products) (2 h/ day, for 14 days); b) 40% hydrogen peroxide gel (Opalescence Boost, Ultradent Products) (three bleaching sessions, once a week, 45 min/session); c) whitening rinse (Listerine Whitening Extreme, Johnson & Johnson) (2 min/day, for 14 days); and d) distilled water (control). The samples were submitted to triplicate readings (Ra and color [CIELAB parameters]) before and after contact with bleaching protocols. Micromorphology was analyzed in a scanning electron microscope (SEM). Ra and color parameters (ΔL, Δa, Δb and ΔE) were analyzed by generalized linear models (α=0.05). The Ra of the high-viscosity bulk-fill was significantly higher than that of the other composites (p<0.05). Ra increased significantly (p<0.05) and surface became more irregular (SEM analysis) in all the composite resins, regardless of the bleaching protocol (p<0.05). The high-viscosity bulk-fill composite resin group had significantly lower ΔE (p<0.05) than the nanoparticulate composite resin group immersed in distilled water. It was concluded that the characteristics of each resin significantly influenced the Ra more than the bleaching protocol. The high-viscosity bulk-fill resin presented minor color change.


RESUMO Este estudo in vitro teve objetivo de avaliar o efeito de protocolos clareadores sobre a rugosidade de superfície (Ra), alteração de cor e micromorfologia de resina bulk-fill de baixa viscosidade (Filtek Bulk Fill Flow, 3M ESPE), alta viscosidade (Filtek Bulk Fill, 3M ESPE) e de uma resina composta nanoparticulada (controle) (Filtek Z350 XT, 3M ESPE). Quarenta amostras de cada resin composta (discos de 5 mm de diâmetro e 2 mm de espessura) foram aleatoriamente divididas em quatro grupos , de acordo com protocolo clareador (n=10): a) Gel de peróxido de carbamida (Opalescence, Ultradent Products) (2 horas/dia, por 14 dias); b) Gel de peróxido de hidrogênio (Opalescence Boost, Ultradent Products) (3 sessões de clareamento, uma por semana, 45 min/sessão); enxaguatório clareador (Listerine Whitening Extreme, Johnson & Johnson) (2 min/dia, por 14 dias); d) água destilada (controle). As amostras foram submetidas a leituras, em triplicata (Ra e cor (parâmetros CIELab) antes e depois do contato com os protocolos clareadores. A micromorfologia de superfície foi conduzida em microscópio eletrônico de varredura (MEV). Ra e parâmetros de cor (ΔL, Δa, Δb e ΔE) foram analisados por modelos lineares generalizados (α=0.05). A Ra da resina bulk-fill de alta viscosidade foi significantemente superior do que para os outros compósitos (pp<0.05). A Ra aumentou significantemente (p<0.05) e a superfície ficou mais irregular (MEV) para todos os compósitos, independente do protocolo clareador (pp<0,05). A resina bulk-fill de alta viscosidade obteve menor ΔE (pp<0.05) do que a resina composta nanoparticulada, imersa em água destilada. Pode-se concluir que as características de cada resina composta influenciaram de forma mais significativa a Ra do que o protocolo clareador. A resina bulk fill de alta viscosidade apresentou menor alteração de cor.


Asunto(s)
Humanos , Blanqueamiento de Dientes/métodos , Decoloración de Dientes/tratamiento farmacológico , Viscosidad/efectos de los fármacos , Resinas Compuestas/química , Blanqueadores Dentales/química , Peróxido de Hidrógeno/química , Ensayo de Materiales , Color
20.
Am J Dent ; 33(4): 213-217, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32794397

RESUMEN

PURPOSE: To perform a clinical and radiographic evaluation comparing Filtek Bulk Fill high viscosity bulk-fill resins with Filtek Z350 XT nanoparticulate for 1 year. METHODS: 58 restorations were performed for each material (bulk-fill and nanoparticulate), for a total of 116 restorations. Among these, 42 Class I and 16 Class II restorations were performed for each group, in molars and premolars. Clinical evaluation was performed 7 days (baseline), 6 months and 1 year after restorations, using the World Dental Federation (FDI) criteria. Radiographs were obtained at 7 days and 1 year after the restoration was placed and the radiopacity was measured using Image J software at the same time interval. RESULTS: Of the 70 restorations available for evaluation at 1 year, the Mann-Whitney and Friedman tests showed no statistically significant difference for the FDI criteria analyzed. Greater radiopacity was observed for bulk-fill resin compared to nanoparticulate (two-way ANOVA, P= 0.022). This same test showed no difference in radiopacity between the groups in the two evaluation periods (P= 0.062). The high viscosity bulk-fill resin composite presented similar clinical performance to nanoparticulate resin in this evaluation period and higher radiopacity was observed for this material when compared to nanoparticulate resin, in both time periods. CLINICAL SIGNIFICANCE: The high viscosity bulk-fill resin composite showed similar performance to the nanoparticulate resin during the evaluation period of 1 year. Radiopacity showed high values for the bulk-fill resin when compared to nanoparticulate resin. The bulk-fill resin has potential to be used in posterior teeth.


Asunto(s)
Materiales Dentales , Restauración Dental Permanente , Diente Premolar , Resinas Compuestas , Diente Molar , Viscosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...