Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Diagnostics (Basel) ; 14(10)2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38786320

RESUMEN

BACKGROUND: Echocardiographic myocardial work is a new load-independent echocardiographic technique to quantify left ventricle (LV) systolic performance. Our aim was to establish normal values for echocardiographic myocardial work in a large population of healthy children. METHODS: For all the subjects 4-, 2-, and 3-chamber-view videos were stored. The following parameters were obtained by offline analysis: the global myocardial work (GMW), the global myocardial constructive work (GCW), the global myocardial wasted work (GWW), and the global myocardial work efficiency (GWE). Age, weight, height, heart rate, and body surface area (BSA) were used as independent variables in the statistical analysis. RESULTS: In all, 516 healthy subjects (age range, 1 day-18 years; median age, 8.2 ± 5.3 years; 55.8% male; body surface area (BSA) range, 0.16 to 2.12 m2) were included. GWI, GCW, and GWW increased with weight, height, and BSA (ρ ranging from 0.635 to 0.226, p all < 0.01); GWI and GCW positively correlated with age (ρ 0.653 and 0.507). After adjusting for BSA differences, females showed higher mean GWI (p = 0.002) and GCW values (p < 0.001), thus Z-score equations for gender have been presented. CONCLUSIONS: We provided MW values in a large population of healthy pediatric subjects including lower ages. MW values increased with age and body size and, interestingly, were higher in females than in men. These data cover a gap in current nomograms and may serve as a baseline for the evaluation of MW analysis in children with congenital and acquired heart diseases.

2.
Diagnostics (Basel) ; 14(10)2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38786327

RESUMEN

BACKGROUND: Although coronary artery nomograms in children have been published, data on Caucasian children are lacking. The aim of this study is to provide: (i) a full dataset of coronary artery diameters in healthy children and (ii) a comparison among major previous nomograms. MATERIALS AND METHODS: We prospectively evaluated 606 healthy subjects (age range, 1 days-<18 years; median age 8.7 years; 62.5% male). Coronary artery measurements in a short-axis view were performed. Age, heart rate, and body surface area (BSA) were used as independent variables in different analyses to predict the mean values of each measurement. To assess the accuracy of the predictive models of different studies, a Z-score calculator was created using Lopez's nomograms for comparison. RESULTS: The association with BSA was found to be stronger, and was used for normalization of our data. The best-fit models, satisfying the assumption of homoscedasticity and normality of residuals and showing the highest R2 scores, were logarithmic (ln[y] = a + b*ln[x]). Predicted values and Z-score boundaries by BSA are provided. Our ranges of normality are slightly lower than those, diverging from -0.22 to -0.59 Z-scores for the left main coronary artery and from -0.23 to -0.3 Z-scores for the right coronary artery. CONCLUSIONS: We report a complete dataset of normal echocardiography coronary artery diameter (including new measures of the proximal origin) values in a large population of healthy children. Our data were statistically like those of north American nomograms.

3.
J Pers Med ; 14(3)2024 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-38541044

RESUMEN

Despite significant improvements in techniques, the treatment of neonates and infants with congenital heart disease resulting in duct-dependent pulmonary circulation is still significantly challenging. Despite current trends toward early primary surgical repair, temporary palliation is still necessary in those patients who are at high surgical risk for complete correction due to unfavorable clinical or anatomic characteristics. Recent advances in interventional cardiology have led to the emergence of right ventricular outflow tract and arterial duct stenting as cost-effective alternatives to surgical palliation in high-risk surgical candidates or whenever short-term pulmonary blood flow support is anticipated. This review aims to explore the evolving landscape of these transcatheter approaches, highlighting their role, efficacy and potential complications in the context of duct-dependent pulmonary circulation anatomies.

4.
Healthcare (Basel) ; 12(3)2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38338232

RESUMEN

BACKGROUND: The decision to perform biventricular repair (BVR) in neonates and infants presenting with either single or multiple left ventricle outflow obstructions (LVOTOs) and a borderline left ventricle (BLV) is subject to extensive discussion, and limited information is known regarding the long-term outcomes. As a result, the objective of this study is to critically assess and summarize the available data regarding the prognosis of neonates and infants with LVOTO and BLV who underwent BVR. METHODS: In February 2023, we conducted a review study with three different medical search engines (the National Library of Medicine, Science Direct, and Cochrane Library) for Medical Subject Headings and free text terms including "congenital heart disease", "outcome", and "borderline left ventricle". The search was refined by adding keywords for "Shone's complex", "complex LVOT obstruction", "hypoplastic left heart syndrome/complex", and "critical aortic stenosis". RESULTS: Out of a total of 51 studies, 15 studies were included in the final analysis. The authors utilized heterogeneous definitions to characterize BLV, resulting in considerable variation in inclusion criteria among studies. Three distinct categories of studies were identified, encompassing those specifically designed to evaluate BLV, those focused on Shone's complex, and finally those on aortic stenosis. Despite the challenges associated with comparing data originating from slightly different cardiac defects and from different eras, our results indicate a favorable survival rate and clinical outcome following BVR. However, the incidence of reintervention remains high, and concerns persist regarding residual pulmonary hypertension, which has been inadequately investigated. CONCLUSIONS: The available data concerning neonates and infants with LVOTO and BLV who undergo BVR are inadequate and fragmented. Consequently, large-scale studies are necessary to fully ascertain the long-term outcome of these complex defects.

5.
Healthcare (Basel) ; 12(2)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38275542

RESUMEN

Blood speckle tracking echocardiography (BSTE) is a new, promising 4D flow ultrafast non-focal plane imaging technique. The aim of the present investigation is to provide a review and update on potentialities and application of BSTE in children with congenital heart disease (CHD) and acquired heart disease. A literature search was performed within the National Library of Medicine using the keywords "echocardiography", "BST", and "children". The search was refined by adding the keywords "ultrafast imaging", "CHD", and "4D flow". Fifteen studies were finally included. Our analysis outlined how BSTE is highly feasible, fast, and easy for visualization of normal/abnormal flow patterns in healthy children and in those with CHD. BSTE allows for visualization and basic 2D measures of normal/abnormal vortices forming the ventricles and in the main vessel. Left ventricular vortex characteristics and aortic flow patterns have been described both in healthy children and in those with CHD. Complex analysis (e.g., energy loss, vorticity, and vector complexity) are also highly feasible with BSTE, but software is currently available only for research. Furthermore, current technology allows for BSTE only in neonates and low-weight children (e.g., <40 kg). In summary, the feasibility and potentialities of BSTE as a complementary diagnostic tool in children have been proved; however, its systemic use is hampered by the lack of (i) accessible tools for complex quantification and for acquisition at all ages/weight, (ii) data on the diagnostic/prognostic significance of BSTE, and (iii) consensus/recommendation papers indicating when and how BSTE should be employed.

6.
J Clin Med ; 12(16)2023 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-37629399

RESUMEN

We started with the experience of thrombus formation in the native aorta of a 3-year-old male child with hypoplastic left heart syndrome (HLHS) and severely hypoplastic but patent mitral and aortic valves after Glenn palliation, which occurred soon after left heart decompression by percutaneous stenting of the atrial septum. The diagnosis was incidental, with the child completely asymptomatic, and progressively subsided in a few days with heparin infusion and chronic warfarin therapy. We reviewed the incidence, diagnosis, and management of native aortic thrombosis in HLHS after different stages of Fontan palliation through a systematic literature search. In all 32 cases, native aortic thrombosis in HLHS was found. The HLHS anatomic subtypes included mitral stenosis/aortic stenosis (fourteen cases or 45.2%), mitral stenosis/aortic atresia (eleven cases or 35.5%), and mitral atresia/aortic atresia (four cases or 12.9%). The age at diagnosis ranged from 13 days to 18 years. Clinical presentation varied from incidental findings, chest pain and/or electrocardiographic abnormalities, cardiac arrest, and transient ischemic attack. Diagnosis was feasible in most of the cases with only transthoracic echocardiography. Mostly (59.4%), patients were treated with anticoagulation, while others underwent surgical (18.7%), direct (12.5%), or systemic (9.3%) thrombolysis. Transplant-free survival was 56.2%, and fatal events occurred in 25%. Major events occurred in 26.3% of those treated with anticoagulation, in 33.3% of patients treated with surgical/systemic thrombolysis, and in 100% of patients treated with direct thrombolysis. In summary, native aortic thrombosis in HLHS may occur at different ages, with a wide spectrum of presentation from incidental finding to a sudden major event. Diagnosis is feasible with transthoracic echocardiography, and management with anticoagulation is effective despite the incidence of major events remaining high.

7.
J Clin Med ; 12(14)2023 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-37510714

RESUMEN

The aim of the present review is to highlight the strengths and limitations of echocardiographic parameters and scores employed to predict favorable outcome in complex congenital heart diseases (CHDs) with borderline right ventricle (RV), with a focus on pulmonary atresia with intact ventricular septum and critical pulmonary stenosis (PAIVS/CPS). A systematic search in the National Library of Medicine using Medical Subject Headings and free-text terms including echocardiography, CHD, and scores, was performed. The search was refined by adding keywords "PAIVS/CPS", Ebstein's anomaly, and unbalanced atrioventricular septal defect with left dominance. A total of 22 studies were selected for final analysis; 12 of them were focused on parameters to predict biventricular repair (BVR)/pulmonary blood flow augmentation in PAIVS/CPS. All of these studies presented numerical (the limited sample size) and methodological limitations (retrospective design, poor definition of inclusion/exclusion criteria, variability in the definition of outcomes, differences in adopted surgical and interventional strategies). There was heterogeneity in the echocardiographic parameters employed and cut-off values proposed, with difficultly in establishing which one should be recommended. Easy scores such as TV/MV (tricuspid/mitral valve) and RV/LV (right/left ventricle) ratios were proven to have a good prognostic accuracy; however, the data were very limited (only two studies with <40 subjects). In larger studies, RV end-diastolic area and a higher degree of tricuspid regurgitation were also proven as accurate predictors of successful BVR. These measures, however, may be either operator and/or load/pressure dependent. TV Z-scores have been proposed by several authors, but old and heterogenous nomograms sources have been employed, thus producing discordant results. In summary, we provide a review of the currently available echocardiographic parameters for risk prediction in CHDs with a diminutive RV that may serve as a guide for use in clinical practice.

8.
J Am Heart Assoc ; 12(8): e026335, 2023 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-37066781

RESUMEN

Background Blood speckle tracking echocardiography allows for direct quantification of interventricular and aortic flow profiles, principally in children. Here, we sought to demonstrate the feasibility and reproducibility of blood speckle tracking echocardiography in the aortas of healthy children. Methods and Results One hundred healthy White children evaluated for the screening of congenital heart disease were prospectively enrolled. Echocardiographic examinations were performed using a Vivid E 95 ultrasound system, with blood speckle tracking from a focused and zoomed view of the aortic root and the ascending aorta. Vortex position, height (mm), width (mm), sphericity index, and area (cm2) were measured and indexed by body surface area. Median (interquartile range) age was 8.2 (5.6-11.0) years, median (interquartile range) weight was 28 (19-35) kg, and median (interquartile range) body surface area was 1.01 (0.79-1.16) m2. Vortices were visualized in only a single phase of the cardiac cycle in 25 subjects-14 (56.0%) were evident in early diastole and 11 (44.0%) in late systole. Vortices visualized in diastole had a mean area of 0.27±0.1 cm2/m2, while those in systole had a mean area of 0.34±0.12 cm2/m2. In a subset of 20 patients, inter- and intraobserver coefficient of variation and intraclass correlation coefficients were determined and showed good reproducibility. Conclusions We demonstrate feasibility and reproducibility of blood speckle tracking and identified vortical flow patterns in the aortic root and ascending aorta in healthy children. These data may serve as a baseline for evaluating aortic flow patterns in children with congenital and acquired heart disease.


Asunto(s)
Ecocardiografía , Cardiopatías Congénitas , Humanos , Niño , Reproducibilidad de los Resultados , Ecocardiografía/métodos , Aorta/diagnóstico por imagen , Ultrasonografía , Cardiopatías Congénitas/diagnóstico por imagen
9.
Heart Fail Rev ; 28(1): 63-76, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35332415

RESUMEN

The aim of this review is to highlight the strengths and limitations of major echocardiographic biventricular repair (BVR) prediction models for borderline left ventricle (LV) in complex congenital heart disease (CHD). A systematic search in the National Library of Medicine for Medical Subject Headings and free text terms including echocardiography, CHD, and scores, was performed. The search was refined by adding keywords for critical aortic stenosis (AS), borderline LV, complex left ventricular outflow tract (LVOT) obstruction, hypoplastic left heart syndrome/complex (HLHS/HLHC), and unbalanced atrio-ventricular septal defects (uAVSD). Fifteen studies were selected for the final analysis. We outlined what echocardiographic scores for different types of complex CHD with diminutive LV are available. Scores for CHD with LVOT obstruction including critical AS, HLHS/HLHC, and aortic arch hypoplasia have been validated and implemented by several studies. Scores for uAVSD with right ventricle (RV) dominance have also been established and implemented, the first being the atrioventricular valve index (AVVI). In addition to AVII, both LV/RV inflow angle and LV inflow index have all been validated for the prediction of BVR. We conclude with a discussion of limitations in the development and validation of each of these scores, including retrospective design during score development, heterogeneity in echocardiographic parameters evaluated, variability in the definition of outcomes, differences in adopted surgical and Interventional strategies, and institutional differences. Furthermore, scores developed in the past two decades may have little clinical relevance now. In summary, we provide a review of echocardiographic scores for BVR in complex CHD with a diminutive LV that may serve as a guide for use in modern clinical practice.


Asunto(s)
Estenosis de la Válvula Aórtica , Cardiopatías Congénitas , Obstrucción del Flujo de Salida Ventricular Izquierda , Humanos , Ventrículos Cardíacos , Estudios Retrospectivos , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/cirugía , Ecocardiografía
10.
Ann Pediatr Cardiol ; 15(2): 192-194, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36246756

RESUMEN

Atrioventricular block (AVB) is an infrequent but life-threatening complication of transcatheter closure of atrial septal defect (ASD), accounting for 0.1%-6.2% of cases in large series. It has been related to unfavorable defect anatomy as well as size and intrinsic stiffness of the occluding device. In this setting, the new GORE® cardioform ASD occluder (GCA) device could be an appealing technical advance in ASD treatment. We report a case of complete AVB after ASD closure with an Amplatzer septal occluding (Abbott, Plymouth MN, USA) device successfully treated by its percutaneous retrieval and "rescue" deployment of GCA device few months later.

11.
Healthcare (Basel) ; 10(10)2022 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-36292337

RESUMEN

Background: Echocardiographic screening of anomalous coronary artery origin is of increasing interest for children participating in sport activities. However, criteria to define normal coronary artery origins in children are poorly defined. Thus, the aim of the present investigation is to define the normal origin and angle of emergence of coronary arteries by echocardiography in healthy children. Materials and methods: The distances of the left main and right coronary artery (LMCA, RCA) origins from the aortic annulus were measured in the parasternal long-axis view (LAX). The angle of coronary artery emergence was measured in the parasternal short-axis view (SAX). Results: A total of 700 healthy subjects (mean age: 9.53 ± 5.95 years; range: 1 day−17.98 years) were prospectively enrolled. The distance of the RCA and LMCA from the aortic annulus correlated with body surface area, and nomograms (Z-scores) were generated. The RCA origin was below the sinotubular junction (STJ) in 605 patients (86.43%), at the STJ in 66 patients (9.43%), and above the STJ in 29 patients (4.14%). The LMCA origin was below the STJ in 671 patients (95.86%), at the STJ in 12 patients (1.71%), and above the STJ in 17 patients (2.43%). With respect to the RCA, an emergence angle < 18.5° in the SAX predicted a high take-off. with a sensitivity of 98.3% and a specificity of 93.1% (AUC 0.998). With respect to the LMCA, an emergence angle > 119.5° in the SAX predicted a high take-off, with a sensitivity of 70.6% and a specificity of 82.4% (AUC 0.799). Conclusion: This study establishes nomograms for LMCA and RCA origin in standard echocardiographic projections in healthy children.

12.
J Clin Med ; 11(20)2022 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-36294320

RESUMEN

Background: Lung ultrasound (LUS) is gaining consensus as a non-invasive diagnostic imaging method for the evaluation of pulmonary disease in children. Aim: To clarify what type of artifacts (e.g., B-lines, pleural irregularity) can be defined normal LUS findings in children and to evaluate the differences in children who did not experience COVID-19 and in those with recent, not severe, previous COVID-19. Methods: LUS was performed according to standardized protocols. Different patterns of normality were defined: pattern 1: no plural irregularity and no B-lines; pattern 2: only mild basal posterior plural irregularity and no B-lines; pattern 3: mild posterior basal/para-spine/apical pleural irregularity and no B-lines; pattern 4: like pattern 3 plus rare B-lines; pattern 5: mild, diffuse short subpleural vertical artifacts and rare B-lines; pattern 6: mild, diffuse short subpleural vertical artifacts and limited B-lines; pattern 7: like pattern 6 plus minimal subpleural atelectasis. Coalescent B-lines, consolidations, or effusion were considered pathological. Results: Overall, 459 healthy children were prospectively recruited (mean age 10.564 ± 3.839 years). Children were divided into two groups: group 1 (n = 336), those who had not had COVID-19 infection, and group 2 (n = 123), those who experienced COVID-19 infection. Children with previous COVID-19 had higher values of LUS score than those who had not (p = 0.0002). Children with asymptomatic COVID-19 had similar LUS score as those who did not have infections (p > 0.05), while those who had symptoms showed higher LUS score than those who had not shown symptoms (p = 0.0228). Conclusions: We report the pattern of normality for LUS examination in children. We also showed that otherwise healthy children who recovered from COVID-19 and even those who were mildly symptomatic had more "physiological" artifacts at LUS examinations.

13.
J Card Surg ; 37(10): 3200-3206, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35900295

RESUMEN

OBJECTIVE: To evaluate the GORE® Cardioform ASD Occluder (GCA)(WL Gore & Associates) device for closure of ostium secundum atrial septal defects (ASDs) with predicted indication for surgical correction. BACKGROUND: Closure of large ASD in small children by transcatheter approach is still challenging. This study evaluated the results of GCA in this subset of patients in a tertiary referral center. METHODS: Between January 2020 and March 2022, 97 children underwent transcatheter ASD closure at our Institution. Of them, 38 had a large defect (diameter/weight > 1.2 or diameter/body surface area > 20 mm/m2 ), predicted suitable for surgery and underwent closure with GCA. Procedure results and midterm outcome are reported. RESULTS: Patients' age and weight were 5.5 ± 1.5 years and 19.7 ± 4.7 kg, respectively. Absolute and relative ASD size was 21.5 ± 3.6 mm, 1.1 ± 0.2 mm/kg, and 27.7 ± 4.6 mm/m2 , respectively, resulting in QP/QS of 2.0 ± 0.8. Three patients were sent to surgery after balloon sizing. Four of the remaining 35 patients who underwent device deployment, needed rescue or elective surgery due to device embolization (n = 1), device instability (n = 2) or new-onset tricuspid valve regurgitation (n = 1). Procedure feasibility was 88.6%. Major complications were recorded in two patients (5.7%). Minor complications were recorded in five patients (14.3%). Complete closure at discharge was 90.3% (28/31 pts) rising to 100% at the last follow-up evaluation. Wireframe fracture rate at the 6 months examination was 52%, without clinical and instrumental consequences. CONCLUSIONS: Percutaneous treatment with GCA device is effective and safe in a high percentage of ASD children with predicted indications for surgical correction.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Cateterismo Cardíaco/métodos , Niño , Defectos del Tabique Interatrial/cirugía , Humanos , Diseño de Prótesis , Resultado del Tratamiento
14.
J Clin Med ; 11(9)2022 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-35566624

RESUMEN

Background: Applications of atrial speckle tracking echocardiography (STE) strain (ε) analysis in pediatric cardiac surgery have been limited. This study aims to evaluate the feasibility of atrial STE ε analysis and the progression of atrial ε values as a function of post-operative time in children after pediatric cardiac surgery. Methods: 131 children (mean 1.69 ± 2.98; range 0.01−15.16 years) undergoing cardiac surgery were prospectively enrolled. Echocardiographic examinations were performed pre-operatively and at 3 different post-operative intervals: Time 1 (24−36 h), Time 2 (3−5 days), Time 3 (>5 days, before discharging). The right and left atrium longitudinal systolic contractile (Ct), Conduit (Cd), and Reservoir (R) ε were evaluated with a novel atrial specific software with both P- and R-Gating methods. One hundred and thirty-one age-matched normal subjects (mean 1.7 ± 3.2 years) were included as controls. Results: In all, 309 examinations were performed over the post-operative times. For each post-operative interval, all STE atrial ε parameters assessed were significantly lower compared to controls (all p < 0.0001). The lowest atrial ε values were found at Time 1, with only partial recovery thereafter (p from 0.02 to 0.04). All atrial ε values at discharge were decreased compared to the controls (all p < 0.0001). Significant correlations of the atrial ε values with cardio-pulmonary-bypass time, left and right ventricular ε values (p < 0.05), and ejection fraction (p < 0.05) were demonstrated. Conclusions: Atrial ε is highly reduced after surgery with only partial post-operative recovery in the near term. Our study additionally demonstrates that post-surgical atrial and ventricular ε responses correlated with each other.

15.
Diagnostics (Basel) ; 12(3)2022 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-35328316

RESUMEN

Lung ultrasound (LUS) is increasing in its popularity for the diagnosis of pulmonary complications in acute pediatric care settings. Despite the high incidence of pulmonary complications for patients with pediatric cardiovascular and congenital heart disease, especially in children undergoing cardiac surgery, the use of LUS remains quite limited in these patients. The aim of this review is to provide a comprehensive overview and list of current potential applications for LUS in children with congenital heart disease, post-surgery. We herein describe protocols for LUS examinations in children, discuss diagnostic criteria, and introduce methods for the diagnosis and classification of pulmonary disease commonly encountered in pediatric cardiology (e.g., pleural effusion, atelectasis, interstitial edema, pneumothorax, pneumonia, and diaphragmatic motion analysis). Furthermore, applications of chest ultrasounds for the evaluation of the retrosternal area, and in particular, systematic search criteria for retrosternal clots, are illustrated. We also discussed the potential applications of LUS, including the guidance of interventional procedures, namely lung recruitment and drainage insertion. Lastly, we analyzed current gaps in knowledge, including the difficulty of the quantification of pleural effusion and atelectasis, and the need to differentiate different etiologies of B-lines. We concluded with future applications of LUS, including strain analysis and advanced analysis of diaphragmatic mechanics. In summary, US is an easy, accurate, fast, cheap, and radiation-free tool for the diagnosis and follow-up of major pulmonary complications in pediatric cardiac surgery, and we strongly encourage its use in routine practice.

16.
Healthcare (Basel) ; 10(2)2022 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-35206969

RESUMEN

BACKGROUND: While mitral (MV) and tricuspid valve (TV) pulsed Doppler velocities and derived gradients are commonly evaluated, data on normal pediatric values are limited. This study aimed to evaluate the normal values and physiological variability for MV and TV Doppler velocities and derived gradients in a large cohort of prospectively enrolled healthy children. METHODS: The echocardiographic measurements included pulsed Doppler MV and TV E and A velocities, E deceleration times (EDT), maximal and mean gradients, and velocity time integral (VTI). RESULTS: A total of 544 healthy subjects (median age 6.4 years, range 1 day-17.68 years) were included. MV and TV E velocity, E/A ratio, and E and A wave duration increased, while A velocity decreased with age (p < 0.001). Along with an increase in VTI, there occurred a progressive increase in maximum velocity and gradients and a decrease in mean velocities and gradients. E/A inversions were common, especially at the TV in neonates and infants. For MV, inversion in either one, two, or three consecutive beats occurred in 51.9% of neonates and 18.3% of infants, while it was rare at older ages (all p < 0.001). For TV, inversions in three consecutive beats occurred in 71.4% of neonates, while inversions in only one or two beats were more common in infants (27.3%). For TV, inversion in one or more beats, however, was not infrequent at all ages. CONCLUSIONS: We report normal values and patterns of normality and physiological variability for MV and TV inflow Doppler from a large population of healthy children.

17.
Clin J Sport Med ; 32(3): e230-e242, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-34009785

RESUMEN

BACKGROUND: Postexercise release of cardiac troponin (cTn) is a well-known phenomenon, although the influence of various confounders remains unclear. The aim of this critical review was to analyze the postexercise release of cTn according to age, sex, different types of sport, exercise intensity and duration, and training level. DATA SOURCES: A literature search was performed within the National Library of Medicine using the following keywords: cTn, peak, release, and exercise. The search was further refined by adding the keywords athletes, children/adolescents, and sport. MAIN RESULTS: For final analysis, 52 studies were included: 43 adult studies, 4 pediatric studies, and 5 with a mixed population of adults and children. Several studies have investigated the kinetics of cTn response after exercise with different biomarkers. The current evidence suggests that sport intensity and duration have significant effects on postexercise cTn elevation, whereas the influence of the type of sport, age, and sex have been not completely defined yet. Most data were obtained during endurance races, whereas evidence is limited (or almost absent), particularly for mixed sports. Data on young adults and professional athletes are limited. Finally, studies on women are extremely limited, and those for non-White are absent. CONCLUSIONS: Postexercise release of cTn can be observed both in young and master athletes and usually represents a physiological phenomenon; however, more rarely, it may unmask a subclinical cardiac disease. The influence of different confounders (age, sex, sport type/intensity/duration, and training level) should be better clarified to establish individualized ranges of normality for postexercise cTn elevation.


Asunto(s)
Deportes , Troponina T , Adolescente , Atletas , Biomarcadores , Niño , Ejercicio Físico/fisiología , Femenino , Humanos , Estados Unidos , Adulto Joven
18.
Catheter Cardiovasc Interv ; 99(1): E22-E30, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34652048

RESUMEN

OBJECTIVE: To evaluate the GORE® Cardioform ASD Occluder (GCO) (WL Gore & Associates, Flagstaff, AZ) device for "complex" atrial septal defects (ASD) closure. BACKGROUND: Transcatheter ASD closure is still challenging in "complex" clinical/anatomic settings. This study evaluated the results of GCO in closure of "complex" ASD in a tertiary referral center. METHODS: Between January 2020 and March 2021, 72 patients with significant ASD were submitted to transcatheter closure with GCO at our Institution. Based on clinical/anatomic characteristics, they were classified as "complex" (n = 36, Group I) or "simple" (n = 36, Group II). We considered as "complex", defects with rim deficiency (< 5 mm) other than antero-superior, relatively large (diameter/patient weight > 1.2 or diameter/patient BSA > 20 mm/m2 ) or within a multifenestrated septum. Procedure results and early outcome were compared between the groups. RESULTS: Absolute and relative ASD size (20 ± 4 vs. 15 ± 3 mm, p < 0.0001; 0.9 ± 0.3 vs. 0.4 ± 0.2 mm/kg, p < 0.0001; 23 ± 7 vs. 12 ± 5 mm/m2 , p < 0.0001), QP/QS (2.0 ± 0.8 vs. 1.4 ± 0.3, p < 0.001), procedure and fluoroscopy times (73 ± 36 vs. 43 ± 21 min, p < 0.0001; 16 ± 9 vs. 9 ± 4 min, p < 0.0001, procedure feasibility (94.4 vs. 100%, p < 0.0001) and overall complication rate (13.9 vs. 0%, p < 0.0001) were significantly different between the groups. Successful closure of "surgical" ASDs was achieved in 92% of cases. Complete closure at last follow-up evaluation did not significantly differ between the groups (97.1 vs. 100%, p = NS), as was wireframe fractures rate (49.1% in the overall population), without clinical, EKG and echocardiographic consequences. CONCLUSIONS: Percutaneous treatment with GCO device is effective and safe in high percentage of "complex" ASDs.


Asunto(s)
Defectos del Tabique Interatrial , Dispositivo Oclusor Septal , Cateterismo Cardíaco/efectos adversos , Ecocardiografía Transesofágica , Defectos del Tabique Interatrial/diagnóstico por imagen , Defectos del Tabique Interatrial/terapia , Humanos , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
19.
Int J Cardiol Heart Vasc ; 37: 100897, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34786451

RESUMEN

BACKGROUND: High-frame rate blood speckle tracking (BST) echocardiography is a new technique for the assessment of intracardiac flow. The purpose of this study was to evaluate the characteristics of left ventricular (LV) vortices in healthy children and in those with congenital heart disease (CHD). METHODS: Characteristics of LV vortices were analyses based on 4-chamber BST images from 118 healthy children (median age 6.84 years, range 0.01-17 years) and 43 children with CHD (median age 0.99 years, range 0.01-14 years). Both groups were compared after propensity matching. Multiple linear regression was used to identify factors that independently influence vortex characteristics. RESULTS: Feasibility of vortex imaging was 93.7% for healthy children and 95.6% for CHD. After propensity matching, there were no overall significant differences in vortex distance to apex, distance to interventricular septum (IVS), height, width, sphericity index, or area. However, multiple regression analysis revealed significant associations of LV morphology with vortex characteristics. Furthermore, CHD involving LV volume overload and CHD involving LV pressure overload were both associated with vortices localized closer to the IVS. CONCLUSIONS: LV vortex analysis using high-frame rate BST echocardiography is feasible in healthy children and in those with CHD. As they are associated with LV morphology and are modified in some types of CHD, vortices might yield diagnostic and prognostic value. Future studies are warranted to establish applications of vortex imaging in the clinical setting.

20.
Echocardiography ; 38(12): 2025-2031, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34820892

RESUMEN

BACKGROUND: 2D speckle tracking echocardiography (STE) atrial strain (ε) analysis in children is gaining interest; however, pediatric nomograms remain limited. Comparison among conventional software's (designed for left ventricle and adapted to atria and using R-gating analysis) and new software's (designed for atria and allowing for both R- and P-gating) are lacking. The present study aims to establish pediatric nomograms for atrial ε using an atrial dedicated software and to compare values obtained by (a) R- and P-gating and, (b) R-gating with new and conventional software. METHODS: Echocardiographic measurements included STE left (LA) and right (RA) atrial longitudinal reservoir, conduit and contractile ε. Age/weigh/height/heart rate, and body surface area (BSA) were used as independent variables in the statistical analysis. RESULTS: In all, 580 healthy subjects (age range, 31 days-18 years; mean age 7.5 years; median age 7.1 years; inter-quartile range, 4.3-10.7 months; 45.5% female) were included. Feasibility of atrial ε measurements was high (98.9-96.8%). At lower age, atrial conduit ε was lower (p<0.001) while contractile ε was higher (p<0.001). All atrial ε values calculated with P-gating method were lower-than R-gating values (p<0.001). R-gated LA ε reservoir values generated with the new software were lower, and R-gated RA contractile ε higher than with the conventional software (p<0.011). CONCLUSION: We report pediatric atrial ε values from a dedicated atrial software. Maturational changes in STE atrial ε values were demonstrated. Significant differences were observed among ε values obtained with P- and R-gating and with different software's.


Asunto(s)
Atrios Cardíacos , Ventrículos Cardíacos , Adulto , Niño , Ecocardiografía , Femenino , Voluntarios Sanos , Atrios Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...