Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-27990418

RESUMEN

Nucleus replacement technologies are a minimally invasive alternative to spinal fusion and total disc replacement that have the potential to reduce pain and restore motion for patients with degenerative disc disease. Finite element modeling can be used to determine the biomechanics associated with nucleus replacement technologies. The current study focuses on a new nucleus replacement device designed as a conforming silicone implant with an internal void. A validated finite element model of the human lumbar L3-L4 motion segment was developed and used to investigate the influence of the nucleus replacement device on spine biomechanics. In addition, the effect of device design changes on biomechanics was determined. A 3D, L3-L4 finite element model was constructed from medical imaging data. Models were created with the normal intact nucleus, the nucleus replacement device, and a solid silicone implant. Probabilistic analysis was performed on the normal model to provide quantitative validation metrics. Sensitivity analysis was performed on the silicone Shore A durometer of the device. Models were loaded under axial compression followed by flexion/extension, lateral bending, or axial rotation. Compressive displacement, endplate stresses, reaction moment, and annulus stresses were determined and compared between the different models. The novel nucleus replacement device resulted in similar compressive displacement, endplate stress, and annulus stress and slightly higher reaction moment compared with the normal nucleus. The solid implant resulted in decreased displacement, increased endplate stress, decreased annulus stress, and decreased reaction moment compared with the novel device. With increasing silicone durometer, compressive displacement decreased, endplate stress increased, reaction moment increased, and annulus stress decreased. Finite element analysis was used to show that the novel nucleus replacement device results in similar biomechanics compared with the normal intact nucleus.

2.
Artículo en Inglés | MEDLINE | ID: mdl-25506051

RESUMEN

Cervical spinal injuries are a significant concern in all trauma injuries. Recent military conflicts have demonstrated the substantial risk of spinal injury for the modern warfighter. Finite element models used to investigate injury mechanisms often fail to examine the effects of variation in geometry or material properties on mechanical behavior. The goals of this study were to model geometric variation for a set of cervical spines, to extend this model to a parametric finite element model, and, as a first step, to validate the parametric model against experimental data for low-loading conditions. Individual finite element models were created using cervical spine (C3-T1) computed tomography data for five male cadavers. Statistical shape modeling (SSM) was used to generate a parametric finite element model incorporating variability of spine geometry, and soft-tissue material property variation was also included. The probabilistic loading response of the parametric model was determined under flexion-extension, axial rotation, and lateral bending and validated by comparison to experimental data. Based on qualitative and quantitative comparison of the experimental loading response and model simulations, we suggest that the model performs adequately under relatively low-level loading conditions in multiple loading directions. In conclusion, SSM methods coupled with finite element analyses within a probabilistic framework, along with the ability to statistically validate the overall model performance, provide innovative and important steps toward describing the differences in vertebral morphology, spinal curvature, and variation in material properties. We suggest that these methods, with additional investigation and validation under injurious loading conditions, will lead to understanding and mitigating the risks of injury in the spine and other musculoskeletal structures.

3.
Artículo en Inglés | MEDLINE | ID: mdl-23113530

RESUMEN

The objective of this investigation was to develop probabilistic finite element (FE) models of the anterior longitudinal ligament (ALL) and posterior longitudinal ligament (PLL) of the cervical spine that incorporate the natural variability of biological specimens. In addition to the model development, a rigorous validation methodology was developed to quantify model performance. Experimental data for the geometry and dynamic properties of the ALL and PLL were used to create probabilistic FE models capable of predicting not only the mean dynamic relaxation response but also the observed experimental variation of that response. The probabilistic FE model uses a quasilinear viscoelastic material constitutive model to capture the time-dependent behaviour of the ligaments. The probabilistic analysis approach yields a statistical distribution for the model-predicted response at each time point rather than a single deterministic quantity (e.g. ligament force) and that response can be statistically compared to experimental data for validation. A quantitative metric that compares the cumulative distribution functions of the experimental data and model response is computed for both the ALL and PLL throughout the time histories and is used to quantify model performance.


Asunto(s)
Análisis de Elementos Finitos , Ligamentos Longitudinales/fisiología , Modelos Estadísticos , Fenómenos Biomecánicos , Vértebras Cervicales/fisiología , Femenino , Humanos , Ligamentos Longitudinales/anatomía & histología , Masculino
4.
Proc Natl Acad Sci U S A ; 107(31): 13648-53, 2010 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-20643964

RESUMEN

Osteocytes with long dendritic processes are known to sense mechanical loading, which is essential for bone remodeling. There has been a long-standing debate with regard to which part(s) of osteocyte, the cell body versus the dendritic process, acts as a mechanical sensor. To address this question experimentally, we used a transwell filter system that differentiates the cell body from the dendritic processes. Mechanical loading was applied to either the cell body or the dendrites, and the osteocyte's response was observed through connexin 43 hemichannel opening. The hemichannels located on the cell body were induced to open when mechanical loading was applied to either the dendritic processes or the cell body. However, no significant hemichannel activity in the dendrites was detected when either part of the cell was mechanically stimulated. Disruption of the glycocalyx by hyaluronidase on the dendrite side alone is sufficient to diminish a dendrite's ability to induce the opening of hemichannels on the cell body, while hyaluronidase has no such effect when applied to the cell body. Importantly, hyaluronidase treatment to the dendrite side resulted in formation of poor integrin attachments with the reduced ability of the dendrites to form integrin attachments on the underside of the transwell filter. Together, our study suggests that the glycocalyx of the osteocyte dendritic process is required for forming strong integrin attachments. These integrin attachments probably serve as the mechanotransducers that transmit the mechanical signals to the cell body leading to the opening of hemichannels, which permits rapid exchange of factors important for bone remodeling.


Asunto(s)
Dendritas , Osteocitos/citología , Estrés Mecánico , Animales , Células Cultivadas , Pollos , Conexina 43/metabolismo , Dendritas/metabolismo , Glicosilación , Humanos , Osteocitos/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA