Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
J Soc Cardiovasc Angiogr Interv ; 3(6): 101940, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39132591

RESUMEN

Transcatheter aortic valve replacement by alternate access sites allows for treatment of patients with unfavorable anatomy for a transfemoral approach. To our knowledge, we present the first reported case of successful transcatheter aortic valve replacement via the transcarotid approach in a 65-year-old man with a symptomatic severe bicuspid aortic valve stenosis and virtually atretic coarctation of the thoracic aorta.

3.
Front Cardiovasc Med ; 11: 1437626, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39175626

RESUMEN

Aortic Stenosis (AS) is a common condition with an estimated pooled prevalence of all AS in the elderly population at around 12.4%, with that of severe AS estimated to be around 3.4%. In the past, surgical aortic valve replacement was the primary treatment option for severe AS for decades. However, with the compelling evidence on the safety and efficacy of transcatheter aortic valve replacement (TAVR), it has become the gold standard treatment option for many patients with symptomatic severe AS. Transfemoral access has been the preferred method for transcatheter heart valve delivery. However, the prevalent use of TAVR on a diverse patient profile with different risk factors, such as peripheral artery disease, precluded the possibility of a transfemoral approach despite the improvement of valves and delivery systems technology. Therefore, alternative TAVR approaches have gained increasing utility in cases where transfemoral access is unfavorable. We review the journey, evolution, and techniques for different approaches of percutaneous TAVR, including transfemoral, transcarotid, transsubclavian/transaxillary, and transcaval approaches, in addition to the traditional "surgical" transaortic and transapical accesses. Consolidating these data highlights each approach's practicality and limitations, providing additional grounding for case-by-case utilization and future clinical research.

4.
J Med Case Rep ; 18(1): 340, 2024 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-38997777

RESUMEN

BACKGROUND: This case highlights several complications of a late and rare presentation of culture-negative Streptococcus pyogenes endocarditis of a previously repaired mitral valve with an annuloplasty ring including recurrent cardioembolic strokes, which was initially missed on transthoracic echocardiography. CASE PRESENTATION: A 66-year-old Caucasian female with prior mitral valve prolapse status post mitral valve annuloplasty and left atrial appendage occlusion, followed by two strokes, presented with supraventricular tachycardia that resolved spontaneously. During an inpatient admission, she developed symptoms of another stroke, and imaging studies were suggestive of recurrent cardioembolic phenomenon. Additional workup revealed two small intra-atrial masses adherent to the mitral annuloplasty ring missed on prior evaluation for recurrent stroke. She underwent surgical repair in the setting of a chronic culture-negative infectious endocarditis with Streptococcus pyogenes and recovered well with no further cardioembolic phenomenon. CONCLUSION: This case serves to highlight the importance of having a higher index of suspicion in any cardiac prosthesis patient for endocarditis when presenting with symptoms such as recurrent stroke, arrhythmias, and abnormal cardiac lab work. It also demonstrates the need for appropriate imaging with transthoracic echocardiography followed by transesophageal echocardiography and reviews surgical indications to diagnose and treat culture-negative endocarditis.


Asunto(s)
Ecocardiografía , Endocarditis Bacteriana , Infecciones Estreptocócicas , Streptococcus pyogenes , Humanos , Femenino , Anciano , Streptococcus pyogenes/aislamiento & purificación , Infecciones Estreptocócicas/diagnóstico por imagen , Endocarditis Bacteriana/diagnóstico por imagen , Endocarditis Bacteriana/microbiología , Endocarditis Bacteriana/cirugía , Anuloplastia de la Válvula Mitral , Prolapso de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/diagnóstico por imagen , Ecocardiografía Transesofágica , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/cirugía
7.
Interv Cardiol Clin ; 13(2): 279-289, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38432770

RESUMEN

Treatment for mixed valve disease has historically been limited, often surgery being the only option. With the recent advancement of transcatheter therapies, percutaneous approaches are quickly becoming viable therapeutic considerations in inoperable or high-risk patients, also offering the option for a staged or same-session treatment. Guidelines are primarily focused on single-valve disease. However, patients often present with multiple pathologies. This review summarizes the data and literature on transcatheter treatment of patients with mitral regurgitation who concomitantly have aortic stenosis or regurgitation, tricuspid regurgitation, or ischemic cardiomyopathy. Pathophysiology, hemodynamics, available therapies as well as order and timing of interventions are discussed.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia de la Válvula Mitral , Isquemia Miocárdica , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia de la Válvula Tricúspide/cirugía
8.
Interv Cardiol ; 18: e31, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38213748

RESUMEN

Percutaneous coronary intervention with stent implantation is an integral aspect of minimally interventional cardiac procedures. The technology and techniques behind stent design and implantation have evolved rapidly over several decades. However, continued discourse remains around optimal peri- and post-interventional management with dual antiplatelet therapy to minimise both major cardiovascular or cerebrovascular events and iatrogenic bleeding risk. Standard guidelines around dual antiplatelet therapy historically recommended long-term dual antiplatelet therapy for 12 months (with consideration for >12 months in certain patients); however, emerging data and generational improvements in the safety of drug-eluting stents have ushered in a new era of short-term therapy to reduce the incidence of major bleeding events. This case review will provide an overview of the current state of guidelines around duration of dual antiplatelet therapy and examine recent updates and continued gaps in existing research.

9.
Clin Res Cardiol ; 110(12): 1993-2006, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34505192

RESUMEN

BACKGROUND: Bicuspid aortic valve may be associated with increased complications during transcatheter aortic valve implantation (TAVI). AIMS: Compare balloon-expandable transcatheter heart valve (THV) safety and efficacy in severe tricuspid (TAV) and bicuspid (BAV) aortic stenosis. METHODS: Transfemoral TAVI was performed in 743 patients (Jan 2014-June 2019) using the SAPIEN 3 THV. Aortic valve morphology was determined using computed tomography. Valve Academic Research Consortium-2 (VARC-2) derived safety and efficacy endpoints at 1 year were evaluated. RESULTS: BAV patients (n = 78), were younger (77 [72, 81] vs. 81 [78, 85] years, p < 0.001) with lower surgical risk (EuroSCORE II 2.96% vs. 4.51% p < 0.001). Bicuspid valves were more calcified (BAV 1308mm3, TAV 848mm3 p < 0.001) with more asymmetric calcification (BAV 63/78 (81%), TAV 239/665 (36%), p < 0.001). Device success (BAV 94%, TAV 90%, p = 0.45) and major vascular complications (BAV 6%, TAV 9%, p = 0.66) were comparable. At 1 year, there was a trend toward lower combined all-cause mortality and rehospitalization for congestive heart failure in BAV patients (BAV 7%, TAV 13%, p = 0.08) with significantly lower all-cause mortality in this cohort (BAV 1%, TAV 9%, p = 0.020). VARC-2 time-related valve safety (BAV 22%, TAV 20%, p = 0.60) was comparable; however, bioprosthetic valve thrombosis remained more common in BAV patients (BAV 7%, TAV 2%, p = 0.010, Hazard ratio 3.57 [95% confidence interval 1.26, 10.10]). After propensity score matching, only bioprosthetic valve thrombosis remained significantly different. CONCLUSIONS: Safety and efficacy of the SAPIEN 3 balloon-expandable THV in BAV is comparable with TAV. Higher rates of bioprosthetic valve thrombosis require further investigation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Tricúspide/cirugía , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tomografía Computarizada Multidetector/métodos , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
10.
Am J Cardiol ; 139: 71-78, 2021 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-33190811

RESUMEN

We aimed to evaluate the efficacy and safety of a low-dose imaging protocol to reduce intraprocedural radiation during transcatheter aortic valve implantation (TAVI). Observational analysis: 802 transfemoral TAVI patients receiving balloon-expandable devices ≥23 mm at a high-volume centre. After propensity score matching, a standard-dose group (SD, n = 333) treated between January 2014 and February 2016 was compared with a low-dose group (LD, n = 333) treated between August 2017 and March 2019 after departmental uptake of a low-dose imaging protocol (reduced field size, high table height, use of "fluoro save," 3.75 frames/second acquisition, increased filtering). Primary end point was dose-area product (DAP). Secondary safety end points were VARC-2 device success and a composite of in-hospital complications. The LD protocol was associated with lower DAP (4.64 [2.93, 8.42] vs 22.73 [12.31, 34.58] Gy⋅cm2, p <0.001) and fluoroscopy time (10.4 [8.1, 13.9] vs 11.5 [9.1, 15.3] minutes, p = 0.001). Contrast use was higher in the LD group (LD 110 [94, 130] vs SD 100 [80, 135] milliliters, p = 0.042). Device success (LD 88.3% vs SD 91.3%, p = 0.25), and the composite end point (LD 8.1% vs SD 11.4%, p = 0.19) were similar. In multivariate analysis, the low-dose protocol was associated with a 19.8 Gy⋅cm2 reduction in procedural DAP (p <0.001). In conclusion, compared with standard imaging, a low-dose protocol for TAVI significantly reduced radiation dose without compromising outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Fluoroscopía/métodos , Traumatismos por Radiación/prevención & control , Cirugía Asistida por Computador/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Masculino , Pronóstico , Estudios Retrospectivos , Factores de Riesgo
11.
Eur J Heart Fail ; 22(2): 330-337, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31863563

RESUMEN

AIMS: The aim of the present study was to investigate the impact of aspirin on prognosis in takotsubo syndrome (TTS). METHODS AND RESULTS: Patients from the International Takotsubo (InterTAK) Registry were categorized into two groups based on aspirin prescription at discharge. A comparison of clinical outcomes between groups was performed using an adjusted analysis with propensity score (PS) stratification; results from the unadjusted analysis were also reported to note the effect of the PS adjustment. Major adverse cardiac and cerebrovascular events (MACCE: a composite of death, myocardial infarction, TTS recurrence, stroke or transient ischaemic attack) were assessed at 30-day and 5-year follow-up. A total of 1533 TTS patients with known status regarding aspirin prescription at discharge were included. According to the adjusted analysis based on PS stratification, aspirin was not associated with a lower hazard of MACCE at 30-day [hazard ratio (HR) 1.24, 95% confidence interval (CI) 0.50-3.04, P = 0.64] or 5-year follow-up (HR 1.11, 95% CI 0.78-1.58, P = 0.58). These results were confirmed by sensitivity analyses performed with alternative PS-based methods, i.e. covariate adjustment and inverse probability of treatment weighting. CONCLUSION: In the present study, no association was found between aspirin use in TTS patients and a reduced risk of MACCE at 30-day and 5-year follow-up. These findings should be confirmed in adequately powered randomized controlled trials. ClinicalTrials.gov Identifier: NCT01947621.


Asunto(s)
Aspirina/uso terapéutico , Cardiomiopatía de Takotsubo , Insuficiencia Cardíaca , Humanos , Ataque Isquémico Transitorio , Infarto del Miocardio , Inhibidores de Agregación Plaquetaria/uso terapéutico , Puntaje de Propensión , Recurrencia , Sistema de Registros , Accidente Cerebrovascular , Cardiomiopatía de Takotsubo/tratamiento farmacológico , Cardiomiopatía de Takotsubo/epidemiología , Resultado del Tratamiento
13.
J Am Heart Assoc ; 8(15): e010881, 2019 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-31311438

RESUMEN

Background Clinical characteristics and outcomes of takotsubo syndrome (TTS) patients with malignancy have not been fully elucidated. This study sought to explore differences in clinical characteristics and to investigate short- and long-term outcomes in TTS patients with or without malignancy. Methods and Results TTS patients were enrolled from the International Takotsubo Registry. The TTS cohort was divided into patients with and without malignancy to investigate differences in clinical characteristics and to assess short- and long-term mortality. A subanalysis was performed comparing long-term mortality between a subset of TTS patients with or without malignancy and acute coronary syndrome (ACS) patients with or without malignancy. Malignancy was observed in 16.6% of 1604 TTS patients. Patients with malignancy were older and more likely to have physical triggers, but less likely to have emotional triggers compared with those without malignancy. Long-term mortality was higher in patients with malignancy (P<0.001), while short-term outcome was comparable (P=0.17). In a subanalysis, long-term mortality was comparable between TTS patients with malignancies and ACS patients with malignancies (P=0.13). Malignancy emerged as an independent predictor of long-term mortality. Conclusions A substantial number of TTS patients show an association with malignancy. History of malignancy might increase the risk for TTS, and therefore, appropriate screening for malignancy should be considered in these patients. Clinical Trial Registration URL: http://www.clinicaltrial.gov. Unique identifier: NCT01947621.


Asunto(s)
Neoplasias/diagnóstico , Neoplasias/mortalidad , Cardiomiopatía de Takotsubo/diagnóstico , Cardiomiopatía de Takotsubo/mortalidad , Anciano , Femenino , Humanos , Cooperación Internacional , Masculino , Persona de Mediana Edad , Neoplasias/complicaciones , Estudios Prospectivos , Sistema de Registros , Estudios Retrospectivos , Cardiomiopatía de Takotsubo/complicaciones , Factores de Tiempo
14.
Eur Heart J ; 40(19): 1490-1491, 2019 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-31087052
15.
Eur Heart J ; 40(6): 505-506, 2019 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-30753630
16.
JACC Cardiovasc Interv ; 12(2): 182-193, 2019 01 28.
Artículo en Inglés | MEDLINE | ID: mdl-30678797

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the predictors of left ventricular outflow tract (LVOT) obstruction after transcatheter mitral valve replacement (TMVR). BACKGROUND: LVOT obstruction is a major concern with TMVR, but limited data exist regarding its predictors and impact on outcomes. METHODS: Patients with pre-procedural multidetector row computed tomography (MDCT) undergoing TMVR for failed mitral bioprosthetic valves (valve-in-valve), annuloplasty rings (valve-in-ring), and mitral annular calcification (valve-in-MAC) were included in this study. Echocardiographic and procedural characteristics were recorded, and comprehensive assessment with MDCT was performed to identify the predictors of LVOT obstruction (defined as an increment of mean LVOT gradient ≥10 mm Hg from baseline). The new LVOT (neo-LVOT) area left after TMVR was estimated by embedding a virtual valve into the mitral annulus on MDCT, simulating the procedure. RESULTS: Among 194 patients with pre-procedural MDCT undergoing TMVR (valve-in-valve, 107 patients; valve-in-ring, 50 patients; valve-in-MAC, 37 patients), LVOT obstruction was observed in 26 patients (13.4%), with a higher rate after valve-in-MAC than valve-in-ring and valve-in-valve (54.1% vs. 8.0% vs. 1.9%; p < 0.001). Patients with LVOT obstruction had significantly higher procedural mortality compared with those without LVOT obstruction (34.6% vs. 2.4%; p < 0.001). Receiver-operating characteristic curve analysis showed that an estimated neo-LVOT area ≤1.7 cm2 predicted LVOT obstruction with sensitivity of 96.2% and specificity of 92.3%. CONCLUSIONS: LVOT obstruction after TMVR was associated with higher procedural mortality. A small estimated neo-LVOT area was significantly associated with LVOT obstruction after TMVR and may help identify patients at high risk for LVOT obstruction.


Asunto(s)
Calcinosis/cirugía , Cateterismo Cardíaco/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Obstrucción del Flujo Ventricular Externo/etiología , Anciano , Anciano de 80 o más Años , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Calcinosis/fisiopatología , Cateterismo Cardíaco/instrumentación , Cateterismo Cardíaco/mortalidad , Ecocardiografía , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Estenosis de la Válvula Mitral/diagnóstico por imagen , Estenosis de la Válvula Mitral/mortalidad , Estenosis de la Válvula Mitral/fisiopatología , Tomografía Computarizada Multidetector , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/mortalidad , Obstrucción del Flujo Ventricular Externo/fisiopatología
17.
Clin Res Cardiol ; 108(1): 6-15, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29948292

RESUMEN

Bicuspid aortic valve (BAV) anatomy is becoming an increasingly frequently encountered challenge in transcatheter aortic valve implantation (TAVI). Bicommissural non-raphe-type BAV (Sievers and Schmidtke Type 0) is composed morphologically of two aortic cusps with no raphe and is less common than the tricommissural or bicommissural raphe-type configurations. Precise annular sizing is a key step for successful TAVI in BAV. The challenge in bicommissural non-raphe-type BAV is that a three-dimensional structure has to be reconstructed using only two anatomical hinge points. For this reason, available software are limited when it comes to bicommissural non-raphe-type BAV. We propose that manual assessment of the aortic root in bicommissural non-raphe-type BAV using multi-planar reconstruction (MPR) software can be performed successfully by aligning the two available hinge points and measuring the smallest identifiable annular dimensions in the transverse plane (Fig. 1). We identified 12 patients with bicommissural non-raphe-type BAV undergoing TAVI between January 2013 and December 2017 in our high-volume institution. Our novel sizing strategy was employed prospectively in three patients-with good clinical outcomes-and evaluated retrospectively in the remainder (Table 1). No patient suffered a central major vascular complication or required new permanent pacemaker implantation. Device success occurred in all patients except one (post-procedural echocardiographic transvalvular gradient of 23 mmHg). In the retrospectively assessed cases, the novel annulus measure was concordant with the implanted THV size in 7 out of 9 procedures and, importantly, did not overestimate the annulus dimensions in any case. Furthermore, in two balloon-expandable THV cases the new measure may, in retrospect, have prompted consideration of a smaller implant size. To be noted, balloon sizing of the aortic annulus has additional value when selecting the valve size in BAV anatomy. Further prospective validation of this novel MDCT sizing technique is required.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/diagnóstico , Imagenología Tridimensional , Tomografía Computarizada Multidetector/métodos , Enfermedad de la Válvula Aórtica Bicúspide , Humanos
18.
Eur Heart J ; 40(5): 441-451, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30357365

RESUMEN

Aims: We sought to evaluate the outcomes of transcatheter mitral valve replacement (TMVR) for patients with degenerated bioprostheses [valve-in-valve (ViV)], failed annuloplasty rings [valve-in-ring (ViR)], and severe mitral annular calcification [valve-in-mitral annular calcification (ViMAC)]. Methods and results: From the TMVR multicentre registry, procedural and clinical outcomes of ViV, ViR, and ViMAC were compared according to Mitral Valve Academic Research Consortium (MVARC) criteria. A total of 521 patients with mean Society of Thoracic Surgeons score of 9.0 ± 7.0% underwent TMVR (322 patients with ViV, 141 with ViR, and 58 with ViMAC). Trans-septal access and the Sapien valves were used in 39.5% and 90.0%, respectively. Overall technical success was excellent at 87.1%. However, left ventricular outflow tract obstruction occurred more frequently after ViMAC compared with ViR and ViV (39.7% vs. 5.0% vs. 2.2%; P < 0.001), whereas second valve implantation was more frequent in ViR compared with ViMAC and ViV (12.1% vs. 5.2% vs. 2.5%; P < 0.001). Accordingly, technical success rate was higher after ViV compared with ViR and ViMAC (94.4% vs. 80.9% vs. 62.1%; P < 0.001). Compared with ViMAC and ViV groups, ViR group had more frequent post-procedural mitral regurgitation ≥moderate (18.4% vs. 13.8% vs. 5.6%; P < 0.001) and subsequent paravalvular leak closure (7.8% vs. 0.0% vs. 2.2%; P = 0.006). All-cause mortality was higher after ViMAC compared with ViR and ViV at 30 days (34.5% vs. 9.9% vs. 6.2%; log-rank P < 0.001) and 1 year (62.8% vs. 30.6% vs. 14.0%; log-rank P < 0.001). On multivariable analysis, patients with failed annuloplasty rings and severe MAC were at increased risk of mortality after TMVR [ViR vs. ViV, hazard ratio (HR) 1.99, 95% confidence interval (CI) 1.27-3.12; P = 0.003; ViMAC vs. ViV, HR 5.29, 95% CI 3.29-8.51; P < 0.001]. Conclusion: The TMVR provided excellent outcomes for patients with degenerated bioprostheses despite high surgical risk. However, ViR and ViMAC were associated with higher rates of adverse events and mid-term mortality compared with ViV.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Anuloplastia de la Válvula Mitral , Válvula Mitral/cirugía , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Calcinosis/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/patología , Anuloplastia de la Válvula Mitral/efectos adversos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Accidente Cerebrovascular/etiología , Resultado del Tratamiento
19.
Cardiol Res Pract ; 2018: 9762176, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30356345

RESUMEN

AIMS: To assess the incremental prognostic value of SYNTAX score II (SxSII) as compared to anatomical SYNTAX Score (SxS) and GRACE risk score in patients with acute coronary syndromes who underwent percutaneous coronary intervention. METHODS AND RESULTS: SxSII and SxS were determined in 734 ACS patients. Patients were enrolled in the prospective Special Program University Medicine ACS and the COMFORTABLE AMI cohorts and later on stratified according to tertiles of SxSII (SxSIILow ≤21.5 (n=245), SxSIIMid 21.5-30.6 (n=245), and SxSIIHigh ≥30.6 (n=244). The primary endpoint of adjudicated all-cause mortality and secondary endpoints of MACE (cardiac death, repeat revascularization, and myocardial infarction) and MACCE (all-cause mortality, cerebrovascular events, MI, and repeat revascularization) were determined at 1-year follow-up. SxSII provided incremental predictive information for risk stratification when compared to SxS and GRACE risk score (AUC 0.804, 95% CI 0.77-0.84, p < 0.001 versus 0.67, 95% CI 0.63-0.72, p=0.007 versus 0.69, 95% CI 0.6-0.8, p=0.002), respectively. In a multivariable Cox regression analysis, we found that unlike SxS (adjusted HR 1.013, 95% CI (0.96-1.07), p=0.654), SxSII was significantly associated with all-cause mortality (HR = 1.095, 95% CI (1.06-1.11), p < 0.001). This was also true for the prediction of both secondary outcomes MACE (n=60) and MACCE (n=70) with an adjusted HR = 1.055, 95% CI (1.03-1.08), p < 0.001, and HR = 1.065, 95% CI (1.04-1.09), p < 0.001. CONCLUSION: In patients with ACS who underwent PCI, SxSII is an independent predictor of mortality during 1-year follow-up. SxSII shows superiority in discriminating risk compared to conventional SxS and GRACE for all-cause mortality.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA