Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Proc (Bayl Univ Med Cent) ; 30(1): 57-58, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28127134

RESUMEN

Syncope can result from certain activities that trigger an exaggerated physiological response in susceptible individuals; examples include cough, laugh, and micturition syncope. We report a novel cause for syncope, that due to reflex bradycardia and asystole produced by the use of asthma inhalers. We discuss the possible mechanisms for this effect and briefly review other breathing-related causes of bradycardia.

2.
Proc (Bayl Univ Med Cent) ; 27(3): 226-8, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24982569

RESUMEN

Firefighters who have received an implantable cardioverter-defibrillator (ICD) are asked to retire or are permanently placed on restricted duty because of concerns about their being incapacitated by an ICD shock during a fire emergency. We present the case of a 40-year-old firefighter who, after surviving sudden cardiac arrest and undergoing ICD implantation, sought to demonstrate his fitness for active duty by completing a high-intensity, occupation-specific cardiac rehabilitation training program. The report details the exercise training, ICD monitoring, and stress testing that he underwent. During the post-training treadmill stress test in firefighter turnout gear, the patient reached a functional capacity of 17 metabolic equivalents (METs), exceeding the 12-MET level required for his occupation. He had no ICD shock therapy or recurrent sustained arrhythmias during stress testing or at any time during his cardiac rehabilitation stay. By presenting this case, we hope to stimulate further discussion about firefighters who have an ICD, can meet the functional capacity requirements of their occupation, and want to return to work.

3.
Circ Heart Fail ; 3(6): 650-8, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20852059

RESUMEN

BACKGROUND: Left ventricular (LV) remodeling has been attributed to the segmental loss of viable myocardium due to myocardial infarction (MI), which results in redistribution of cardiac workload, with increased regional wall stress in and around the infarct zone. Because ventricular pacing has been shown to reduce regional wall stress and workload in regions near the pacing site, this trial was designed to test whether chronic pacing near the infarct attenuates LV remodeling. METHODS AND RESULTS: Eighty patients with an anterior MI, peak creatine kinase >2000 mU/mL, ejection fraction ≤35%, wall motion abnormality (WMA) in >5 of 16 segments, and QRS <120 ms, were randomized to either control (implantable cardioverter-defibrillator [ICD]) or biventricular pacing with peri-infarct LV lead placement (cardiac resynchronization therapy [CRT]-D) arms between 2 and 14 days after the MI. The primary end point-change in LV end-diastolic volume (LVEDV) from baseline to 12 months-was not significantly different between the 2 groups (CRT, 10.6±27.7 mL; ICD, 11.2±31.2 mL; 2-sample t test P>0.05). In a hypothesis-generating secondary analysis, there was a sustained reduction in the WMA score at 12 months in paced patients (CRT, -0.16±0.28; ICD, -0.01±0.24, 2-sample t test P=0.03). No differences were found in the therapy-related event rate, hospitalizations, or mortality (all P>0.05). CONCLUSIONS: Chronic pacing in the infarct region did not alter the primary end point of LV remodeling over 1 year.


Asunto(s)
Infarto de la Pared Anterior del Miocardio/complicaciones , Infarto de la Pared Anterior del Miocardio/terapia , Terapia de Resincronización Cardíaca , Cardiomegalia/prevención & control , Dilatación Patológica/prevención & control , Adulto , Anciano , Anciano de 80 o más Años , Infarto de la Pared Anterior del Miocardio/fisiopatología , Cardiomegalia/etiología , Desfibriladores Implantables , Dilatación Patológica/etiología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Método Simple Ciego , Resultado del Tratamiento , Remodelación Ventricular
4.
Am J Cardiol ; 96(3): 414-6, 2005 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-16054471

RESUMEN

We performed a retrospective analysis of 250 records of consecutive, newly implanted, pacemaker patients from a single center to determine the rate of postimplant complications and observations discovered before and during the prehospital discharge evaluation. No observations occurred in 246 of 250 patients (98.4%) (1-sided 95% confidence interval 96.4%). Of the 250 patients, 4 had observations that were discovered at the prehospital discharge check and required reprogramming to increase the sensitivity safety margin (3 atrial and 1 ventricular). We documented only 1 complication that was discovered before the predischarge evaluation through telemetry and resulted in an atrial lead revision.


Asunto(s)
Marcapaso Artificial , Alta del Paciente , Complicaciones Posoperatorias/diagnóstico , Falla de Equipo , Humanos , Estudios Retrospectivos