Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Aging Clin Exp Res ; 34(5): 1073-1080, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34751924

RESUMEN

BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy is well established for secondary prevention, but studies on the efficacy and safety in elderly patients are still lacking. This retrospective study compared the outcome after ICD implantation between octogenarians and other age groups. METHODS: Data were obtained from a local ICD registry. Patients who received ICD implantation for secondary prevention at our department were included. All-cause mortality, appropriate ICD therapy and acute adverse events requiring surgical intervention were compared between different age groups. RESULTS: 519 patients were enrolled, 34 of whom were aged ≥ 80 years. During the median follow-up of 35 months after ICD implantation 129 patients (annual mortality rate 5.0%) had died, including 16 patients aged ≥ 80 years (annual mortality rate 9.4%). The mortality rate of patients aged ≥ 80 years was significantly higher than that of patients aged ≤ 69 years (p < 0.001), but similar to that of patients aged 70-79 years. Age at the time of ICD implantation was an independent predictor of all-cause mortality (p < 0.001). 29.7% of patients had appropriate ICD therapy with no difference between age groups. Acute adverse events leading to surgical intervention were low (n = 13) and not age-related. CONCLUSION: Age is an independent predictor of mortality after ICD implantation for secondary prevention. Mortality rates did not differ significantly between octogenarians and other elderly aged 70-79 years. Appropriate ICD therapy and acute adverse events leading to surgical intervention were not age-related. Implantable cardioverter-defibrillator therapy for secondary prevention seems to be an effective and safe treatment modality in octogenarians.


Asunto(s)
Muerte Súbita Cardíaca , Desfibriladores Implantables , Anciano , Anciano de 80 o más Años , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Humanos , Octogenarios , Prevención Primaria , Estudios Retrospectivos , Factores de Riesgo , Prevención Secundaria , Resultado del Tratamiento
2.
J Clin Med ; 10(21)2021 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-34768499

RESUMEN

Left ventricular (LV) ejection fraction (LVEF) is the most widely used prognostic marker in cardiovascular diseases. LV global function index (LVGFI) is a novel marker which incorporates the total LV structure in the assessment of LV cardiac performance. We evaluated the prognostic significance of LVGFI, measured by cardiovascular magnetic resonance (CMR), in predicting mortality and ICD therapies in a real-world (ICD) population with secondary ICD prevention indication, to detect a high-risk group among these patients. In total, 105 patients with cardiac MRI prior to the ICD implantation were included (mean age 56 ± 16 years old; 76% male). Using the MRI data for each patient LVGFI was determined and a cut-off for the LVGFI value was calculated. Patients were followed up every four to six months in our or clinics in proximity. Data on the occurrence of heart failure symptoms and or mortality, as well as device therapies and other vital parameters, were collected. Follow up duration was 37 months in median. The mean LVGFI was 24.5%, the cut off value for LVGFI 13.5%. According to the LVGFI Index patient were divided into 2 groups, 86 patients in the group with the higher LVGFI und 19 patients in the lower group. The LVGFI correlates significantly with the LVEF (r = 0.642, p < 0.001). In Kaplan-Meier analysis, a lower LVGFI (<13.5%) was associated with a higher rate of mortality and rehospitalization (p = 0.002). In contrast, echocardiographic LVEF ≤ 33% was not associated with a higher rate of mortality or rehospitalization. Multivariate Cox-regression analysis revealed a lower LVGFI (p = 0.025, HR = 0.941; 95%-CI 0.89-0.99) and diabetes mellitus (p = 0.027, HR = 0.33; 95%-CI 0.13-0.88) as an independent predictor for mortality and rehospitalization. There was no association between the combined endpoint and the LVEFMRT, LVEFecho, NYHA > I, the initial device or a medication (each p = n.s.). Further, in Kaplan-Meier analysis no association was evident between the LVGFI and adequate ICD therapy (p = n.s.). In secondary prevention ICD patients reduced LVGFI was shown as an independent predictor for mortality and rehospitalization, but not for ICD therapies. We were able to identify a high-risk collective among these patients, but further investigation is needed to evaluate LVGFI compared to ejection fraction, especially in patients with an elevated risk for adverse cardiac events.

3.
J Interv Card Electrophysiol ; 31(2): 131-9, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21318317

RESUMEN

PURPOSE: Recently, new catheter technologies have been developed for atrial fibrillation (AF) ablation. We investigate the diagnostic accuracy of a circular mapping and pulmonary vein ablation catheter (PVAC) compared with a standard circular mapping catheter (Orbiter) and the influence of filter settings on signal quality. METHODS: After reconstruction of the left atrium by three-dimensional atriography, baseline PV potentials (PVP) were recorded consecutively with PVAC and Orbiter in 20 patients with paroxysmal AF. PVPs were compared and attributed to predefined anatomical PV segments. Ablation was performed in 80 PVs using the PVAC. If isolation of the PVs was assumed, signal assessment of each PV was repeated with the Orbiter. If residual PV potentials could be uncovered, different filter settings were tested to improve mapping quality of the PVAC. Ablation was continued until complete PV isolation (PVI) was confirmed with the Orbiter. RESULTS: Baseline mapping demonstrated a good correlation between the Orbiter and PVAC. Mapping accuracy using the PVAC for mapping and ablation was 94% (74 of 79 PVs). Additional mapping with the Orbiter improved the PV isolation rate to 99%. Adjustment of filter settings failed to improve quality of the PV signals compared with standard filter settings. CONCLUSIONS: Using the PVAC as a stand-alone strategy for mapping and ablation, one should be aware that in some cases, different signal morphology mimics PVI isolation. Adjustment of filter settings failed to improve signal quality. The use of an additional mapping catheter is recommended to become familiar with the particular signal morphology during the first PVAC cases or whenever there is a doubt about successful isolation of the pulmonary veins.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/instrumentación , Ablación por Catéter/instrumentación , Técnicas Electrofisiológicas Cardíacas/métodos , Venas Pulmonares/cirugía , Anciano , Mapeo del Potencial de Superficie Corporal/métodos , Ablación por Catéter/métodos , Catéteres , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Cuidados Intraoperatorios/métodos , Masculino , Persona de Mediana Edad , Venas Pulmonares/diagnóstico por imagen , Radiografía , Medición de Riesgo , Taquicardia Paroxística/diagnóstico , Taquicardia Paroxística/cirugía , Resultado del Tratamiento
4.
Am J Hypertens ; 24(3): 270-7, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21151013

RESUMEN

BACKGROUND: Adiponectin increases nitric oxide (NO) production in endothelial cell cultures and is reduced in the circulation of obese and diabetic patients, but its functional effect on resistance arteries is not yet studied in detail. METHODS: We assessed the direct vasodilatory response of isolated mesenteric resistance arteries of Zucker diabetic fatty (ZDF) rats and Zucker lean (ZL) rats to globular adiponectin (gAd) and full-length adiponectin (fAd) and tested the effect of additional reactive oxygen species (ROS) inhibitors in vitro. Serum adiponectin and insulin levels were measured by ELISA. The mRNA expressions of the adiponectin receptors and the downstream signaling molecules adaptor protein, phosphotyrosine interaction, PH domain and leucine zipper containing 1 (APPL1), adaptor protein, phosphotyrosine interaction, PH domain and leucine zipper containing 2 (APPL2), and endothelial NO synthase (eNOS) in mesenteric resistance arteries were quantified by real-time reverse transcriptase PCR. RESULTS: Both gAd and fAd induced a relevant dose-dependent vasodilation in ZL, but not in hypoadiponectinemic ZDF rats. This effect was totally blunted by L-nitroarginine-methyl-ester indicating NO dependency. The addition of ROS inhibitors could not improve the vasodilatory effect of adiponectin. Vasodilatory response to acetylcholine was reduced in ZDF rats, which could not be enhanced by low-dose adiponectin. Adiponectin receptor 1 (AdipoR1) was higher expressed than adiponectin receptor 2 (AdipoR2) with no significant differences between both animal groups, but APPL1 was significantly decreased in ZDF rats. The eNOS expression was not significantly different between ZL and ZDF rats. CONCLUSIONS: Adiponectin exerts a NO-dependent vasodilation in resistance arteries of normoglycemic ZL rats, but not diabetic ZDF rats. This may contribute to endothelial dysfunction in ZDF rats. Alterations in the expression of APPL1 may be involved in the observed insensitivity to adiponectin in ZDF rats.


Asunto(s)
Adiponectina/farmacología , Diabetes Mellitus/fisiopatología , Óxido Nítrico/fisiología , Obesidad/fisiopatología , Delgadez/fisiopatología , Resistencia Vascular , Vasodilatación/efectos de los fármacos , Acetilcolina/farmacología , Proteínas Adaptadoras Transductoras de Señales , Animales , Proteínas Portadoras/análisis , Relación Dosis-Respuesta a Droga , Masculino , Proteínas del Tejido Nervioso/análisis , Óxido Nítrico Sintasa de Tipo III/análisis , Nitroprusiato/farmacología , Ratas , Ratas Zucker
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA