Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
JSES Rev Rep Tech ; 4(2): 182-188, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38706672

RESUMEN

Hypothesis and/or Background: The incidence of elbow medial ulnar collateral ligament (MUCL) injuries has been increasing, leading to advances in surgical treatments. However, it is not clear that there is consensus among surgeons regarding diagnostic imaging, the indications for acute surgery and postoperative rehabilitation. The purpose of this study is evaluate surgeon variability in the presurgical, surgical, and postsurgical treatment of MUCL injuries regarding the imaging modalities used for diagnosis, indications for acute surgical treatment, and postoperative treatment recommendations for rehabilitation and return to play (RTP). Our hypothesis is that indications for acute surgical treatment will be highly variable based on MUCL tear patterns and that agreement on the time to RTP will be consistent for throwing athletes and inconsistent for nonthrowing athletes. Methods: A survey developed by 6 orthopedic surgeons with expertise in throwing athlete elbow injuries was distributed to 31 orthopedic surgeons who routinely treat MUCL injuries. The survey evaluated diagnostic and treatment topics related to MUCL injuries, and responses reaching 75% agreement were considered as high-level agreement. Results: Twenty-four surgeons responded to the survey, resulting in a 77% response rate. There is 75% or better agreement among surveyed surgeons regarding acute surgical treatment for distal full thickness tears, ulnar nerve transposition in symptomatic patients or with ulnar nerve subluxation, postoperative splinting for 1-2 weeks with initiation of rehabilitation within 2 weeks, the use of bracing after surgery and the initiation of a throwing program at 3 months after MUCL repair with internal brace by surgeons performing 20 or more MUCL surgeries per year. There were a considerable number of survey topics without high-level agreement, particularly regarding the indications for acute surgical treatment, the time to return to throwing and time RTP in both throwing and nonthrowing athletes. Discussion and/or Conclusion: The study reveals that there is agreement for the indication of acute surgical treatment of distal MUCL tears, duration of bracing after surgery, and the time to initiate physical therapy after surgery. There is not clear agreement on indications for surgical treatment for every MUCL tear pattern, RTP time for throwing, hitting and participation in nonthrowing sports.

2.
J ISAKOS ; 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38574995

RESUMEN

OBJECTIVES: Image-guided ultrasound or fluoroscopic glenohumeral injections have high accuracy rates but require training, equipment, cost, and radiation exposure (fluoroscopy). In contrast, landmark-guided glenohumeral injections do not require additional subspecialist referrals or equipment. An optimal technique would be safe and accurate and have few barriers to implementation. The purpose of this study was to define the accuracy of glenohumeral needle placement via an anterior landmark-guided approach as assessed by direct arthroscopic visualization. METHODS: A consecutive series of adult patients undergoing shoulder arthroscopy in the beach chair position were included in this study. Demographic and procedural data were collected. The time required to perform the injection, the precise location of the needle tip, and factors that affected the accuracy of the injection were also assessed. RESULTS: A standardized anterior landmark-guided glenohumeral joint injection was performed in the operating room prior to surgery, and the location of the needle tip was documented by arthroscopic visualization with a low complication profile and few barriers to implementation. A total of 81 patients were enrolled. Successful intra-articular glenohumeral needle placement by sports medicine and shoulder/elbow fellowship-trained orthopedic surgeons was confirmed in 93.8% (76/81) of patients. The average time to complete the procedure was 24.8 â€‹s. There were no patient-related variables associated with nonintra-articular injections in the cohort. CONCLUSIONS: This study demonstrated that the technique of anterior landmark-guided glenohumeral injection has an accuracy of 93.8% and requires less than 30 â€‹s to perform. This method is safe, yields similar accuracy to image-guided procedures, has improved cost and time efficiency, and requires less radiation exposure. No patient-related factors were associated with inaccurate needle placement. Anterior landmark-guided glenohumeral injections may be utilized with confidence by providers in the clinical setting. LEVEL OF EVIDENCE: Level 5. IRB: Approved under Stanford IRB-56323.

3.
Am J Sports Med ; 52(6): 1483-1490, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38650304

RESUMEN

BACKGROUND: Elbow ulnar collateral ligament (UCL) repair with suture brace augmentation shows good time-zero biomechanical strength and a more rapid return to play compared with UCL reconstruction. However, there are concerns about overconstraint or stress shielding with nonabsorbable suture tape. Recently, a collagen-based bioinductive absorbable structural scaffold has been approved by the Food and Drug Administration for augmentation of soft tissue repair. PURPOSE/HYPOTHESIS: This study aimed to assess the initial biomechanical performance of UCL repair augmented with this scaffold. We hypothesized that adding the bioinductive absorbable structural scaffold to primary UCL repair would impart additional time-zero restraint to the valgus opening. STUDY DESIGN: Controlled laboratory study. METHODS: Eight cadaveric elbow specimens-from midforearm to midhumerus-were utilized. In the native state, elbows underwent valgus stress testing at 30o, 60o, and 90o of flexion, with a cyclical valgus rotational torque. Changes in valgus rotation from 2- to 5-N·m torque were recorded as valgus gapping. Testing was then performed in 4 states: (1) native intact UCL-with dissection through skin, fascia, and muscle down to an intact UCL complex; (2) UCL-transected-distal transection of the ligament off the sublime tubercle; (3) augmented repair with bioinductive absorbable scaffold; and (4) repair alone without scaffold. The order of testing of repair states was alternated to account for possible plastic deformation during testing. RESULTS: The UCL-transected state showed the greatest increase in valgus gapping of all states at all flexion angles. Repair alone showed similar valgus gapping to that of the UCL-transected state at 30° (P = .62) and 60° of flexion (P = .11). Bioinductive absorbable scaffold-augmented repair showed less valgus gapping compared with repair alone at all flexion angles (P = .021, P = .024, and P = .024 at 30°, 60°, and 90°, respectively). Scaffold-augmented repair showed greater gapping compared with the native state at 30° (P = .021) and 90° (P = .039) but not at 60° of flexion (P = .059). There was no difference when testing augmented repair or repair alone first. CONCLUSION: UCL repair augmented with a bioinductive, biocomposite absorbable structural scaffold imparts additional biomechanical strength to UCL repair alone, without overconstraint beyond the native state. Further comparative studies are warranted. CLINICAL RELEVANCE: As augmented primary UCL repair becomes more commonly performed, use of an absorbable bioinductive scaffold may allow for improved time-zero mechanical strength, and thus more rapid rehabilitation, while avoiding long-term overconstraint or stress shielding.


Asunto(s)
Ligamento Colateral Cubital , Andamios del Tejido , Humanos , Fenómenos Biomecánicos , Ligamento Colateral Cubital/cirugía , Articulación del Codo/cirugía , Articulación del Codo/fisiopatología , Cadáver , Persona de Mediana Edad , Masculino , Femenino , Reconstrucción del Ligamento Colateral Cubital , Anciano , Colágeno
4.
Sports Health ; : 19417381241237011, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38546157

RESUMEN

CONTEXT: The quality and interprogram variability of publicly available throwing programs have not been assessed. OBJECTIVE: To (1) identify publicly available interval throwing programs, (2) describe their components and structure, and (3) evaluate their quality, variability, and completeness. DATA SOURCES: Google, Bing, Yahoo; keyword: "interval throwing program." STUDY SELECTION: Baseball-specific publicly available programs. STUDY DESIGN: Systematic review. LEVEL OF EVIDENCE: Level 4. DATA EXTRACTION: Independent evaluation by 2 authors using a novel 21-item Quality Assessment Rubric (QAR). RESULTS: Of the 99 included programs, 54% were designed for return from injury/surgery; 42% explicitly stated no expected timeline for completion, and approximately 40% did not provide criteria to initiate the program. Program construction was highly variable. There were broad-ranging shortest (mean: 40±8 ft, range: 20-45 ft) and longest (mean: 150±33 ft, range: 90-250 ft) long toss distances, and variable maximum numbers of mound pitches thrown before returning to game play (range: 40-120, mean: 85). Only 63% of programs provided guidelines for handling setbacks, and standardized warm-ups, arm care, and concomitant training were absent in 32%, 63%, and 47% of programs, respectively. Mean QAR completion rate and QAR item response rate were low (62 ± 4% [range, 24-91%], 62 ± 24% [range, 7-99%], respectively). Finally, only 20 (20%) programs provided at least 1 peer-reviewed reference, most of which were published >10 years ago. CONCLUSION: Publicly available interval throwing programs are readily available but demonstrate significant interprogram heterogeneity across multiple areas including target audience, program construction, progression, and execution. The quality and consistency of publicly available interval throwing programs is poor at this time, which may limit their utility and effectiveness for baseball players attempting to return to competition. This work identifies a multitude of deficiencies in currently available throwing programs that should be targets of future improvement efforts.

5.
J Shoulder Elbow Surg ; 33(5): 1177-1184, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37890765

RESUMEN

BACKGROUND: Mixed reality may offer an alternative for computer-assisted navigation in shoulder arthroplasty. The purpose of this study was to determine the accuracy and precision of mixed-reality guidance for the placement of the glenoid axis pin in cadaver specimens. This step is essential for accurate glenoid placement in total shoulder arthroplasty. METHODS: Fourteen cadaveric shoulders underwent simulated shoulder replacement surgery by 7 experienced shoulder surgeons. The surgeons exposed the cadavers through a deltopectoral approach and then used mixed-reality surgical navigation to insert a guide pin in a preplanned position and trajectory in the glenoid. The mixed-reality system used the Microsoft Hololens 2 headset, navigation software, dedicated instruments with fiducial marker cubes, and a securing pin. Computed tomography scans obtained before and after the procedure were used to plan the surgeries and determine the difference between the planned and executed values for the entry point, version, and inclination. One specimen had to be discarded from the analysis because the guide pin was removed accidentally before obtaining the postprocedure computed tomography scan. RESULTS: Regarding the navigated entry point on the glenoid, the mean difference between planned and executed values was 1.7 ± 0.8 mm; this difference was 1.2 ± 0.6 mm in the superior-inferior direction and 0.9 ± 0.8 mm in the anterior-posterior direction. The maximum deviation from the entry point for all 13 specimens analyzed was 3.1 mm. Regarding version, the mean difference between planned and executed version values was 1.6° ± 1.2°, with a maximum deviation in version for all 13 specimens of 4.1°. Regarding inclination, the mean angular difference was 1.7° ± 1.5°, with a maximum deviation in inclination of 5°. CONCLUSIONS: The mixed-reality navigation system used in this study allowed surgeons to insert the glenoid guide pin on average within 2 mm from the planned entry point and within 2° of version and inclination. The navigated values did not exceed 3 mm or 5°, respectively, for any of the specimens analyzed. This approach may help surgeons more accurately place the definitive glenoid component.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artroplastia de Reemplazo , Realidad Aumentada , Cavidad Glenoidea , Articulación del Hombro , Cirugía Asistida por Computador , Humanos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Artroplastia de Reemplazo/métodos , Cirugía Asistida por Computador/métodos , Cadáver , Imagenología Tridimensional/métodos , Cavidad Glenoidea/diagnóstico por imagen , Cavidad Glenoidea/cirugía
6.
Arthroscopy ; 40(4): 1343-1355.e1, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37832744

RESUMEN

PURPOSE: To systematically review (1) biomechanical properties of augmented elbow ulnar collateral ligament (UCL) repair compared with reconstruction and (2) clinical efficacy and complication rates of UCL repair with and without augmentation. METHODS: A systematic review was completed August 15, 2023, identifying articles that (1) biomechanically compared suture augmented UCL repair and reconstruction and (2) clinically evaluated medial elbow UCL repairs. Search terms included: "UCL repair" OR "internal brace" OR "suture augmentation" AND "UCL reconstruction." For inclusion, biomechanical studies compared augmented repair with reconstruction; clinical studies required clinical outcomes with minimum 6-month follow-up. Biomechanical data included torsional stiffness, gap formation, peak torque, and failure torque. Clinical data included return to previous level of play, time to return, functional outcomes, and complications. RESULTS: In total, 8 biomechanical and 9 clinical studies were included (5 with and 4 without augmentation). In most biomechanical studies, augmented repairs demonstrated less gap formation, with equivalent torsional stiffness, failure load, and peak torque compared with reconstruction. Clinical outcomes in 104 patients without augmentation demonstrated return to previous level of 50% to 94% for nonprofessional athletes and 29% for professional baseball pitchers. Suture augmented repairs in 554 patients demonstrated return to previous level from 92% to 96%, at 3.8 to 7.4 months, with Kerlan Jobe Orthopaedic Clinic scores of 86 to 95. The overall complication rate for augmented UCL repair was 8.7%; most commonly ulnar neuropraxia (6%). CONCLUSIONS: Biomechanically, UCL repair with augmentation provided less gapping with equivalent torsional stiffness and failure compared with reconstruction. Clinically, augmented UCL repair demonstrated excellent return to previous level of play and Kerlan Jobe Orthopaedic Clinic scores with modest complications and time to return. Augmented UCL repair is biomechanically equivalent to reconstruction and may be a viable alternative to reconstruction in indicated athletes. CLINICAL RELEVANCE: UCL repair with suture augmentation is biomechanically equivalent to reconstruction and clinically demonstrates excellent outcomes.


Asunto(s)
Béisbol , Ligamento Colateral Cubital , Ligamentos Colaterales , Articulación del Codo , Reconstrucción del Ligamento Colateral Cubital , Humanos , Codo/cirugía , Ligamento Colateral Cubital/cirugía , Cúbito/cirugía , Articulación del Codo/cirugía , Suturas , Ligamentos Colaterales/cirugía
7.
Instr Course Lect ; 73: 725-736, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38090936

RESUMEN

The ulnar collateral ligament, also called the medial collateral ligament of the elbow, is the primary stabilizer against valgus loads. This ligament can be traumatically torn, such as in an elbow dislocation, or can tear through attritional damage with overhead sports. Although baseball pitching is the most common contributor, these injuries also occur with volleyball, gymnastics, and javelin throwing. Patients most commonly report a history of medial elbow pain with associated loss of command, control, and throw velocity. The ulnar nerve lies directly superficial to the posterior band of the ulnar collateral ligament and ulnar neuritis is commonly associated with ulnar collateral ligament pathology. Nonsurgical treatment, including rest from activity, flexor-pronator strengthening, and possible platelet-rich plasma injections, can be considered for partial-thickness tears. Surgical treatment can be considered for patients in whom nonsurgical treatment fails and full-thickness tears. Historically, surgical treatment involved reconstruction of the ligament with a tendon graft. Ipsilateral palmaris longus autograft has been the most commonly used graft, but contralateral palmaris, autograft hamstring tendons, and allograft tendon have also been used. This procedure has a high rate of return to play and a low complication rate, but most athletes require 12 to 18 months to fully return. More recently, repair of the ligament, with the addition of a biologic ingrowth ligament augmentation suture, has demonstrated similarly high rates of return to play and low complication rates, with a full return to play in 6 months.


Asunto(s)
Béisbol , Ligamento Colateral Cubital , Ligamentos Colaterales , Articulación del Codo , Procedimientos Ortopédicos , Humanos , Ligamento Colateral Cubital/lesiones , Ligamento Colateral Cubital/cirugía , Codo/cirugía , Cúbito/cirugía , Músculo Esquelético/cirugía , Articulación del Codo/cirugía , Béisbol/lesiones , Ligamentos Colaterales/cirugía , Ligamentos Colaterales/lesiones
8.
JSES Rev Rep Tech ; 3(4): 506-510, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37928989

RESUMEN

Background: The impact of single-sport specialization on performance and injury risk in youth and adolescent athletes remains debated. The purpose of this study was to determine the incidence of single-sport specialization and its association with pitch velocity, pitcher utilization, range of motion, strength, and injury history. Methods: High school pitchers in the Northeastern, Southeastern, Midwestern, and Western Regions of the United States were prospectively recruited. Prior to the season, pitchers were surveyed about their basic demographics, sport participation history, and injury history. At this timepoint, a standardized physical examination was performed and max pitch velocity was measured. They were then prospectively followed over the ensuing high school season, where pitch utilization and counts were followed and injuries were tracked. Results: Across the study, 115 pitchers were recruited, of whom 53% played baseball as their only sport and 47% played other sports. Single- position specialization within baseball was uncommon as 90% of athletes played positions other than pitcher. There were no differences in range of motion, strength, or pitch velocity between multisport athletes and single-sport specialists. Within the multisport group, 26% reported a history of injury, while 38% of the single-sport specialists reported a history of injury (P = .179). There were no significant differences in pitcher utilization between multisport athletes and single-sport specialists. Only a single prospective injury occurred in the 115 players. Conclusion: Although single-sport specialization is common, nearly half of all high school pitchers in this study were multisport athletes. While injury history was generally similar between the two groups, single-sport baseball players did not have the following: improved motion, increased strength, higher ball velocity, or greater pitching volumes during the high school baseball season compared to multisport athletes. Accordingly, single-sport specialization did not have a competitive advantage for these high school pitchers based on the performance factors studied. Further prospective studies are necessary to understand the association between single-sport specialization and injury risk in high school baseball players.

9.
Orthop J Sports Med ; 11(9): 23259671231199085, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37781638

RESUMEN

Background: Although pitch count and rest guidelines have been promoted for youth and adolescent baseball players for nearly 2 decades, compliance with guidelines remains poorly understood. Purpose/Hypothesis: The purpose of this study was to determine the frequency of compliance with Major League Baseball (MLB) Pitch Smart guidelines as well as the association between compliance and range of motion (ROM), strength, velocity, injury, and pitcher utilization. It was hypothesized that pitchers in violation of current recommendations would have increased strength, velocity, and injury. Study Design: Case-control study; Level of evidence, 3. Methods: This was a prospective, multicenter study of 115 high school pitchers throughout the United States. Pitchers were surveyed about their compliance with current off-season, rest-related guidelines, and history of injury. During the preseason, pitchers underwent standardized physical examinations, and pitch velocity was measured. Pitch counts were collected during the baseball season that followed. Dynamometer strength testing of shoulder forward flexion, and external rotation as well as grip strength was recorded. We compared pitchers who were compliant with recommendations with those who were noncompliant using Student t and Mann-Whitney U tests. Results: Based on preseason data, 84% of pitchers had violated current Pitch Smart guidelines. During the season, 14% had at least 1 violation of the Pitch Smart guidelines. Across both the preseason survey and in-season pitch counts, 89% of players had at least 1 violation of the Pitch Smart guidelines. While there were no significant differences in ROM or strength, the noncompliant group had higher maximum pitch velocity than the compliant group (74 ± 8 vs 69 ± 5 mph [119 ± 13 vs 111 ± 8 kph], respectively; P = .009). Players' self-reported velocity differed significantly from the direct measurement, for both peak velocity (80 ± 6 vs 73 ± 8 mph [129 ± 9 vs 117 ± 13 kph], respectively; P < .001) and mean velocity (73 ± 8 vs 53 ± 27 mph [117 ± 13 vs 85 ± 43 kph], respectively; P < .001). Conclusion: Most high school pitchers were not fully compliant with current Pitch Smart guidelines, and they tended to overestimate their peak velocity by 7 mph (11 kph). Pitchers who threw with greater velocity were at higher risk for violating Pitch Smart recommendations.

10.
J Surg Orthop Adv ; 32(2): 118-121, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37668650

RESUMEN

In order to evaluate postoperative function and failure rates among younger patients undergoing hemiarthroplasty for humeral head avascular necrosis (AVN), data from patients < 40 years treated between December 2008 - January 2018 was retrospectively analyzed. Pain was assessed preoperatively and at final follow up using a visual analogue scale (VAS). The American Shoulder and Elbow Surgeons (ASES) standardized assessment, single assessment numeric evaluation (SANE) score, and patient satisfaction were assessed at final follow up, as well as surgical revision rates. In total, eight shoulders were included in the final analysis, with a follow up of 6.6 + 3.6 years. Analysis indicated a statistical improvement in VAS pain (p = 0.001), while comparison of postoperative function between surgical and non-surgical limbs did not demonstrate statistical differences in SANE or ASES averages (p > 0.05). At final follow up, 25% of patients expressed dissatisfaction; however, there were no cases of revision surgery. In conclusion, younger patients undergoing hemiarthroplasty for humeral head AVN experienced pain improvement and no revisions at short-to-mid-term follow up, but one-in-four indicated dissatisfaction. Level of evidence: IV, case series. (Journal of Surgical Orthopaedic Advances 32(2):118-121, 2023).


Asunto(s)
Hemiartroplastia , Osteonecrosis , Humanos , Hombro , Cabeza Humeral/cirugía , Estudios Retrospectivos , Osteonecrosis/cirugía , Dolor
11.
JSES Rev Rep Tech ; 3(2): 137-141, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37588444

RESUMEN

Background: Weighted-ball velocity training programs are popular but may be associated with increased injury risk. The purpose of this study was to determine the current frequency of these programs, as well as their association with range of motion, strength, velocity, injury, and utilization in high school baseball pitchers. Methods: This was a multicenter, prospective, community-based study including high schools from the Northeastern, Southeastern, Midwestern, and Western regions of the United States. Preseason pitchers were surveyed about their use of weighted ball velocity programs and history of injury. Preseason pitchers underwent standardized physical examinations and pitch velocity was measured. During a single high school season, pitch counts and injury incidence were prospectively collected. Results: In total, 115 pitchers were recruited, of whom 63% had participated in a weighted ball program. There were no differences in range of motion or strength between groups who used weighted balls and those who did not. Pitchers that utilized weighted ball programs demonstrated a higher average fastball velocity (114.26 vs. 106.22 km/h [71 vs. 66 mph]; P < .001) as well as peak fastball velocity (115.87 vs. 109.44 km/h [72 vs. 68 mph]; P = .001) compared to those that did not use weighted ball programs. Pitchers that utilized weighted ball programs were no more likely to be single-sport athletes (44%) than those who were multisport athletes (49%, P = .667). Within the group who had used a weighted ball program 29% (13/45) reported a history of injury and within the group who had not used a weighted ball program 25% (10/40) reported a history of injury (P = .687). As only a single injury occurred in the entire cohort, comparison of injury rates could not be completed. Conclusion: In this prospective study, the majority of high school pitchers reported using weighted ball programs to increase velocity, and these programs were associated with increased average and peak velocity compared to pitchers who did not use weighted ball programs. There were no significant differences in injury history between the 2 groups. Further study is necessary to understand the injury risk associated with weighted ball programs.

12.
J Shoulder Elbow Surg ; 32(12): 2575-2580, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37481106

RESUMEN

BACKGROUND: Ulnar collateral ligament (UCL) tears are common in baseball players. Although magnetic resonance imaging (MRI) is the most used imaging modality for UCL injuries, the inter-rater reliability of MRI analyzing specific characteristics of UCL pathology has not been defined. The purpose of this study was to define the inter-rater reliability of MRI for evaluating UCL characteristics. METHODS: Three surgeons analyzed 45 noncontrast MRIs: 15 without UCL tears, 15 with intraoperatively confirmed partial-thickness tears, and 15 with intraoperatively confirmed full-thickness tears. Findings evaluated included ligament characteristics (periligamentous or osseous edema, ligament hypertrophy, calcifications, and partial- or full-thickness tearing) and location of the pathology (proximal, midsubstance, or distal). Fleiss' κ coefficients were used to assess interobserver reliability. RESULTS: There were high rates of agreement for midsubstance (κ: 0.50) and distal (κ: 0.69) ligament edema and proximal osseous edema (κ: 0.48). There were low rates of agreement for proximal ligament edema (κ: 0.08), ligament thickening (κ: -0.02 to 0.20), and proximal to midsubstance calcifications (κ: -0.04 to 0.10). Midsubstance (κ: 0.55) and distal full-thickness tears (κ: 0.63) demonstrated higher agreement than proximal (κ: 0.29). Proximal partial-thickness tears (κ: 0.45) had higher agreement than midsubstance (κ: -0.02) or distal (κ: -0.02). CONCLUSIONS: In our study, there was high inter-rater reliability regarding proximal osseous edema, midsubstance, and distal ligament edema and full-thickness tears. There was no agreement for midsubstance and distal partial-thickness UCL tears, but fair agreement for proximal tears. UCL tissue characteristics including ligament thickening and calcifications demonstrated low agreement. Challenges remain in effectively evaluating UCL tissue characteristics on noncontrast MRIs.


Asunto(s)
Béisbol , Ligamento Colateral Cubital , Ligamentos Colaterales , Humanos , Ligamento Colateral Cubital/lesiones , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética , Béisbol/lesiones , Edema/diagnóstico por imagen , Ligamentos Colaterales/cirugía
13.
Sports Health ; 15(4): 476-477, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37357684

Asunto(s)
Deportes , Humanos , Brazo
14.
Shoulder Elbow ; 15(3): 292-299, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37325386

RESUMEN

Background: The purpose of this investigation was to compare rates of filled opioid prescriptions and prolonged opioid use in opioid naïve patients undergoing total shoulder arthroplasty (TSA) in inpatient versus outpatient settings. Methods: A retrospective cohort study was conducted using a national insurance claims database. Inpatient and outpatient cohorts were created by identifying continuously enrolled, opioid naïve TSA patients. A greedy nearest-neighbor algorithm was used to match baseline demographic characteristics between cohorts with a 1:1 inpatient to outpatient ratio to compare the primary outcomes of filled opioid prescriptions and prolonged opioid use following surgery between cohorts. Results: A total of 11,703 opioid naïve patients (mean age 72.5 ± 8.5 years, 54.5% female, 87.6% inpatient) were included for analysis. After propensity score matching (n = 1447 inpatients; n = 1447 outpatients), outpatient TSA patients were significantly more likely to fill an opioid prescription in the perioperative window compared to inpatients (82.9% versus 71.5%, p < 0.001). No significant differences in prolonged opioid use were detected (5.74% inpatient versus 6.77% outpatient; p = 0.25). Conclusions: Outpatient TSA patients were more likely to fill opioid prescriptions compared to inpatient TSA patients. The quantity of opioids prescribed and rates of prolonged opioid use were similar between the cohorts. Level of evidence: Therapeutic Level III.

15.
Orthop J Sports Med ; 11(3): 23259671231151450, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36970319

RESUMEN

Background: Pitch count recommendations are used to reduce injury risk in youth baseball pitchers and are based chiefly on expert opinion, with limited scientific support. Furthermore, they only account for pitches thrown against a hitter and do not include the total number of throws on the day a player pitched. Currently, counts are recorded manually. Purpose: To provide a method using a wearable sensor to quantify total throws per game that is compliant with Little League Baseball rules and regulations. Study Design: Descriptive laboratory study. Methods: Eleven male baseball players (age, 10-11 years) from an 11U (players 11 years and younger) competitive travel team were evaluated over a single summer season. An inertial sensor was placed above the midhumerus of the throwing arm and was worn during baseball games across the season. A throw identification algorithm capturing all throws and reporting linear acceleration and peak linear acceleration was used to quantify throwing intensity. Pitching charts were collected and used to verify actual pitches thrown against a hitter in a game versus all other throws identified. Results: A total of 2748 pitches and 13,429 throws were captured. On the day a player pitched, he averaged 36 ± 18 pitches (23%) and 158 ± 106 total throws (pitches in game as well as all warm-up pitches and other throws during game). In comparison, on a day a player did not pitch, he averaged 119 ± 102 throws. Across all pitchers, 32% of all throws were low intensity, 54% were medium intensity, and 15% were high intensity. The player with one of the highest percentages of high-intensity throws did not pitch as their primary position, while the 2 players who pitched most often had the lowest percentages. Conclusion: Total throw count can be successfully quantified using a single inertial sensor. Total throws tended to be higher on days a player pitched compared with regular game days without pitching. Clinical Relevance: This study provides a fast, feasible, and reliable method to obtain pitch and throw counts so that more rigorous research on contributing factors to arm injury in the youth athlete can be achieved.

16.
J Shoulder Elbow Surg ; 32(5): 1066-1073, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36737035

RESUMEN

BACKGROUND: Ulnar collateral ligament (UCL) tears are common in baseball players. When nonoperative management fails; reconstruction or repair may be necessary to restore physical function. There is no clear consensus regarding the indications for surgery based on magnetic resonance imaging (MRI) tear characteristics or the indications for selecting repair over reconstruction. The purpose of this study was to define the indications for UCL surgery based on MRI and to elucidate indications for UCL repair vs. reconstruction. METHODS: Twenty-six orthopedic surgeons who treat baseball players were surveyed. Forty-five MRIs were reviewed: 15 without UCL tears, 15 with intraoperatively confirmed partial-thickness tears, and 15 with full-thickness tears. Factors investigated included ligament characteristics (periligamentous or osseous edema, ligament hypertrophy, calcification, partial or full-thickness tearing) and location (proximal, midsubstance, or distal). Surgeons were given a clinical scenario and asked whether 1) surgery was indicated and 2) whether repair or reconstruction was recommended. Odds ratios (OR) and 95% confidence intervals (95% CI) helped identify significant predictors for both queries. RESULTS: The odds of recommending surgical treatment compared to nonoperative treatment were 2.4× more likely for a proximal partial-thickness tear, 3.2× for distal partial-thickness tear, 5.1× for distal full-thickness tear, and 7.0× for proximal full-thickness tear (P < .001). Significant indications for repair included distal partial (OR = 1.6, 95% CI 1.0, 2.1, P < .001) and full-thickness tears (OR = 1.7, 95% CI 1.1, 2.3, P < .001). Repair was 3× less likely recommended for midsubstance full-thickness tears (OR = 3.0, 95% CI -5.0, -1.0, P = .004). Ultrasound stress testing was requested in 78% of partial tears. CONCLUSIONS: Among surgeons surveyed, the highest odds for recommending operative treatment were proximal full-thickness tears, then distal full-thickness, distal partial-thickness, and proximal partial-thickness tears. Repair was most appropriate for partial and full-thickness distal tears, but relatively contraindicated for complete midsubstance UCL tears. Ultrasound stress testing was frequently requested for partial tears. Given the lack of consensus among surgeons, future prospective registries are necessary to determine whether these factors associate with clinical outcomes.


Asunto(s)
Béisbol , Ligamento Colateral Cubital , Ligamentos Colaterales , Procedimientos Ortopédicos , Reconstrucción del Ligamento Colateral Cubital , Humanos , Ligamento Colateral Cubital/diagnóstico por imagen , Ligamento Colateral Cubital/cirugía , Imagen por Resonancia Magnética , Ligamentos Colaterales/diagnóstico por imagen , Ligamentos Colaterales/cirugía
17.
Biology (Basel) ; 12(2)2023 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-36829567

RESUMEN

BACKGROUND: There is currently no consensus on immobilization protocols following shoulder surgery. The aim of this study was to establish patterns and types of sling use for various surgical procedures in the United States (US) and Europe, and to identify factors associated with the variations. METHODS: An online survey was sent to all members of the American Shoulder and Elbow Society (ASES) and European Society for Surgery of the Shoulder and Elbow (ESSSE). The survey gathered member data, including practice location and years in practice. It also obtained preferences for the type and duration of sling use after the following surgical procedures: arthroscopic Bankart repair, Latarjet, arthroscopic superior/posterosuperior rotator cuff repair (ARCR) of tears <3 cm and >3 cm, anatomic total shoulder arthroplasty (aTSA) and reverse TSA (rTSA), and isolated biceps tenodesis (BT). Relationships between physician location and sling type for each procedure were analyzed using Fisher's exact tests and post-hoc tests using Bonferroni-adjusted p-values. Relationships looking at years in practice and sling duration preferred were analyzed using Spearman's correlation tests. RESULTS: In total, 499 surgeons with a median of 15 years of experience (IQR = 9-25) responded, with 54.7% from the US and 45.3% from Europe. US respondents reported higher abduction pillow sling use than European respondents for the following: Bankart repair (62% vs. 15%, p < 0.0001), Latarjet (53% vs. 12%, p < 0.001), ARCR < 3 cm (80% vs. 42%, p < 0.001) and >3 cm (84% vs. 61%, p < 0.001), aTSA (50% vs. 21%, p < 0.001) and rTSA with subscapularis repair (61% vs. 22%, p < 0.001) and without subscapularis repair (57% vs. 17%, p < 0.001), and isolated BT (18% vs. 7%, p = 0.006). European respondents reported higher simple sling use than US respondents for the following: Bankart repair (74% vs. 31%, p < 0.001), Latarjet (78% vs. 44%, p < 0.001), ARCR < 3 cm (50% vs. 17%, p < 0.001) and >3 cm (34% vs. 13%, p < 0.001), and aTSA (69% vs. 41%, p < 0.001) and rTSA with subscapularis repair (70% vs. 35%, p < 0.001) and without subscapularis repair (73% vs. 39%, p < 0.001). Increasing years of experience demonstrated a negative correlation with the duration of sling use after Bankart repair (r = -0.20, p < 0.001), Latarjet (r = -0.25, p < 0.001), ARCR < 3 cm (r = -0.14, p = 0.014) and >3 cm (r = -0.20, p < 0.002), and aTSA (r = -0.37, p < 0.001), and rTSA with subscapularis repair (r = -0.10, p = 0.049) and without subscapularis repair (r = -0.19, p = 0.022. Thus, the more experienced surgeons tended to recommend shorter durations of post-operative sling use. US surgeons reported longer post-operative sling durations for Bankart repair (4.8 vs. 4.1 weeks, p < 0.001), Latarjet (4.6 vs. 3.6 weeks, p < 0.001), ARCR < 3 cm (5.2 vs. 4.5 weeks p < 0.001) and >3 cm (5.9 vs. 5.1 weeks, p < 0.001), aTSA (4.9 vs. 4.3 weeks, p < 0.001), rTSR without subscapularis repair (4.0 vs. 3.6 weeks, p = 0.031), and isolated BT (3.7 vs. 3.3 weeks, p = 0.012) than Europe respondents. No significant differences between regions within the US and Europe were demonstrated. CONCLUSIONS: There is considerable variation in the immobilization advocated by surgeons, with geographic location and years of clinical experience influencing patterns of sling use. Future work is required to establish the most clinically beneficial protocols for immobilization following shoulder surgery. LEVEL OF EVIDENCE: Level IV.

18.
Arthroscopy ; 39(8): 1905-1935, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36587750

RESUMEN

PURPOSE: To summarize the incidence of injuries occurring in professional baseball and compare player outcomes reported in the literature. METHODS: We conducted a systematic review using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines across 3 databases (PubMed, MEDLINE, Embase). Inclusion criteria were studies of injury incidences and/or injury outcomes on active Major League Baseball (MLB) athletes and studies published in the English language. Exclusion criteria were non-MLB players, case series and case report studies with a cohort of ≤3 players, and/or review articles. RESULTS: A total of 477 articles were identified from the initial search of 3 databases, with 105 studies meeting inclusion criteria. Among these articles, the most common injuries studied were elbow (38%), shoulder (14%), hip/groin (11%), hand/wrist (7%), head/face (7%), knee (7%), spine (5%), and foot/ankle (3%). Injuries with the greatest incidence included hand/wrist (150.3 per year), hamstring (7.8-73.5 per year), ulnar collateral ligament (UCL) tears (0.23-26.8 per year), gastrocnemius strains (24.2 per year), and concussions (3.6-20.5 per year). Lowest rates of return to play were seen following shoulder labral tears (40%-72.5%), rotator cuff tears (33.3%-87%), and UCL tears (51%-87.9%). The injuries leading to most time away from sport included elbow UCL tears (average 90.3 days treated nonoperatively to 622.8 days following revision reconstruction), shoulder labral tears (average 315-492 days), and anterior cruciate ligament (ACL) tears (average 156.2-417.5 days). Following ACL tears, rotator cuff tears, shoulder labral tears, and hip femoroacetabular impingement requiring arthroscopy, athletes had a significantly lower workloads compared with before injury upon return to play. CONCLUSIONS: Most published investigations focus on elbow injuries of the UCL, with variable return to play and mixed performance following surgery. UCL tears, shoulder labral tears, and ACL tears result in the most missed time. Upper-extremity injury such as shoulder labral tears, rotator cuff tears, and UCL tears had the poorest return to play rates. Workload was most affected following ACL reconstruction, rotator cuff repair, shoulder labral repair, and hip arthroscopy for femoroacetabular impingement. LEVEL OF EVIDENCE: Level IV, systematic review of level II-IV studies.


Asunto(s)
Béisbol , Ligamento Colateral Cubital , Pinzamiento Femoroacetabular , Lesiones del Manguito de los Rotadores , Humanos , Béisbol/lesiones , Volver al Deporte , Codo , Ligamento Colateral Cubital/lesiones
19.
J ISAKOS ; 8(2): 101-107, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36706837

RESUMEN

The management of first-time traumatic anterior shoulder dislocations has been a topic of extensive study yet remains controversial. Development of a treatment plan requires an understanding of patient-specific considerations, including demographics, functional demands, and extent of pathology. Each of these can influence rates of recurrence and return to activity. The purpose of this review is to provide a framework for decision-making following a first-time anterior shoulder dislocation, with particular focus on the high-risk young and athletic population. A summary of surgical treatment options and their outcomes is outlined, along with future biomechanical and clinical perspectives.


Asunto(s)
Inestabilidad de la Articulación , Luxación del Hombro , Articulación del Hombro , Humanos , Hombro , Artroscopía , Inestabilidad de la Articulación/cirugía , Rango del Movimiento Articular , Luxación del Hombro/epidemiología , Luxación del Hombro/cirugía
20.
Sensors (Basel) ; 22(22)2022 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-36433603

RESUMEN

Estimating external workload in baseball pitchers is important for training and rehabilitation. Since current methods of estimating workload through pitch counts and rest days have only been marginally successful, clubs are looking for more sophisticated methods to quantify the mechanical loads experienced by pitchers. Among these are the use of wearable systems. While wearables offer a promising solution, there remains a lack of standards or guidelines for how best to employ these devices. As a result, sensor location and workload calculation methods vary from system to system. This can influence workload estimates and blur their interpretation and utility when making decisions about training or returning to sport. The primary purpose of this study was to determine the extent to which sensor location influences workload estimate. A secondary purpose was to compare estimates using different workload calculations. Acceleration data from three sensor locations-trunk, throwing upper arm, and throwing forearm-were collected from ten collegiate pitchers as they threw a series of pitches during a single bullpen session. The effect of sensor location and pitch type was assessed in relation to four different workload estimates. Sensor location significantly influenced workload estimates. Workload estimates calculated from the forearm sensor were significantly different across pitch types. Whole-body workload measured from a trunk-mounted sensor may not adequately reflect the mechanical loads experienced at throwing arm segments. A sensor on the forearm was the most sensitive to differences in workloads across pitch types, regardless of the calculation method.


Asunto(s)
Béisbol , Carga de Trabajo , Fenómenos Biomecánicos , Extremidad Superior , Brazo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...