Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-23656236

RESUMEN

Ractopamine (RAC) analysis at all stages in the feed chain until its final mixing into swine feed is necessary to ensure the safety of all meat consumers and to decrease waste and the cost of supplementation of feed. Two suitable HPLC methods were developed and validated for RAC determination in vitamin mineral complex (VMC) and in swine feed. Both methods employed reverse-phase (C18 column at 40°C) and isocratic elution, but with some modifications to the methods. Validation parameters, such as selectivity, linearity, precision, trueness and robustness, were shown to be within the acceptable range. Therefore, the developed methods can be successfully applied for the monitoring of RAC concentrations in samples of VMC and swine feed ensuring economy to producers and security to consumers of swine meat.


Asunto(s)
Alimentación Animal/análisis , Cromatografía Líquida de Alta Presión/métodos , Aditivos Alimentarios/análisis , Fenetilaminas/análisis , Animales , Extracción Líquido-Líquido , Estándares de Referencia , Porcinos
2.
J AOAC Int ; 92(3): 757-64, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19610364

RESUMEN

A simple method was optimized and validated for determination of ractopamine hydrochloride (RAC) in raw material and feed additives by HPLC for use in quality control in veterinary industries. The best-optimized conditions were a C8 column (250 x 4.6 mm id, 5.0 microm particle size) at room temperature with acetonitrile-100 mM sodium acetate buffer (pH 5.0; 75 + 25, v/v) mobile phase at a flow rate of 1.0 mL/min and UV detection at 275 nm. With these conditions, the retention time of RAC was around 5.2 min, and standard curves were linear in the concentration range of 160-240 microg/mL (correlation coefficient > or = 0.999). Validation parameters, such as selectivity, linearity, limit of detection (ranged from 1.60 to 2.05 microg/mL), limit of quantification (ranged from 4.26 to 6.84 microg/mL), precision (relative standard deviation < or = 1.87%), accuracy (ranged from 96.97 to 100.54%), and robustness, gave results within acceptable ranges. Therefore, the developed method can be successfully applied for the routine quality control analysis of raw material and feed additives.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Aditivos Alimentarios/análisis , Fenetilaminas/análisis , Estabilidad de Medicamentos
3.
Talanta ; 78(1): 233-41, 2009 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-19174231

RESUMEN

A method for simultaneous determination of seven benzodiazepines (BZPs) (flunitrazepam, clonazepam, oxazepam, lorazepam, chlordiazepoxide, nordiazepam and diazepam using N-desalkylflurazepam as internal standard) in human plasma using liquid-liquid and solid-phase extractions followed by high-performance liquid chromatography (HPLC) is described. The analytes were separated employing a LC-18 DB column (250 mm x 4.6 mm, 5 microm) at 35 degrees C under isocratic conditions using 5mM KH(2)PO(4) buffer solution pH 6.0:methanol:diethyl ether (55:40:5, v/v/v) as mobile phase at a flow rate of 0.8 mL min(-1). UV detection was carried out at 245 nm. Employing LLE, the best conditions were achieved with double extraction of 0.5 mL plasma using ethyl acetate and Na(2)HPO(4) pH 9.5 for pH adjusting. Employing SPE, the best conditions were achieved with 0.5 mL plasma plus 3 mL 0.1M borate buffer pH 9.5, which were then passed through a C18 cartridge previously conditioned, washed for 3 times with these solvents: 3 mL 0.1M borate buffer pH 9.5, 4 mL Milli-Q water and 1 mL acetonitrile 5%, finally the BZPs elution was carried with diethyl ether:n-hexane:methanol (50:30:20). In both methods the solvent was evaporated at 40 degrees C under nitrogen flow. The validation parameters obtained in LLE were linearity range of 50-1200 ng mL(-1) plasma (r>or=0.9927), limits of quantification of 50 ng mL(-1) plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15%, and recovery above 65% for all BZPs. In SPE, the parameter obtained were linearity range of 30-1200 ng mL(-1) plasma (r>or=0.9900), limits of quantification of 30 ng mL(-1) plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15% and recovery above 55% for all BZPs. These extracting procedures followed by HPLC analysis showed their suitable applicability in order to examine one or more BZPs in human plasma. Moreover, it could be suggested that these procedures might be employed in various analytical applications, in special for toxicological/forensic analysis.


Asunto(s)
Benzodiazepinas/sangre , Cromatografía Líquida de Alta Presión/métodos , Benzodiazepinas/análisis , Cromatografía Líquida de Alta Presión/normas , Humanos , Indicadores y Reactivos , Reproducibilidad de los Resultados , Extracción en Fase Sólida/métodos , Solventes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...