Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nano Lett ; 24(21): 6218-6224, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38757765

RESUMEN

Nanopore sensing is a popular biosensing strategy that is being explored for the quantitative analysis of biomarkers. With low concentrations of analytes, nanopore sensors face challenges related to slow response times and selectivity. Here, we demonstrate an approach to rapidly detect species at ultralow concentrations using an optical nanopore blockade sensor for quantitative detection of the protein vascular endothelial growth factor (VEGF). This sensor relies on monitoring fluorescent polystyrene nanoparticles blocking nanopores in a nanopore array of 676 nanopores. The fluorescent signal is read out using a wide-field fluorescence microscope. Nonspecific blockade events are then distinguished from specific blockade events based on the ability to pull the particles out of the pore using an applied electric field. This allows the detection of VEGF at sub-picomolar concentration in less than 15 min.


Asunto(s)
Técnicas Biosensibles , Nanoporos , Poliestirenos , Factor A de Crecimiento Endotelial Vascular , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Factor A de Crecimiento Endotelial Vascular/análisis , Factor A de Crecimiento Endotelial Vascular/antagonistas & inhibidores , Poliestirenos/química , Nanopartículas/química , Humanos , Microscopía Fluorescente/métodos
2.
Chem Soc Rev ; 51(14): 5757-5776, 2022 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-35748606

RESUMEN

Nanopores are promising sensing devices that can be used for the detection of analytes at the single molecule level. It is of importance to understand and model the current response of a nanopore sensor for improving the sensitivity of the sensor, a better interpretation of the behaviours of different analytes in confined nanoscale spaces, and quantitative analysis of the properties of the targets. The current response of a nanopore sensor, usually called a resistive pulse, results from the change in nanopore resistance when an analyte translocates through the nanopore. This article reviews the theoretical models used for the calculation of the resistance of the nanopore, and the corresponding change in nanopore resistance due to a translocation event. Models focus on the resistance of the pore cavity region and the access region of the nanopore. The influence of the sizes, shapes and surface charges of the translocating species and the nanopore, as well as the trajectory that the analyte follows are also discussed. This review aims to give a general guidance to the audience for understanding the current response of a nanopore sensor and the application of this class of sensor to a broad range of species with the theoretical models.


Asunto(s)
Nanoporos , Nanotecnología
3.
Nano Lett ; 22(3): 869-880, 2022 02 09.
Artículo en Inglés | MEDLINE | ID: mdl-35089719

RESUMEN

Nanopore sensors have received significant interest for the detection of clinically important biomarkers with single-molecule resolution. These sensors typically operate by detecting changes in the ionic current through a nanopore due to the translocation of an analyte. Recently, there has been interest in developing optical readout strategies for nanopore sensors for quantitative analysis. This is because they can utilize wide-field microscopy to independently monitor many nanopores within a high-density array. This significantly increases the amount of statistics that can be obtained, thus enabling the analysis of analytes present at ultralow concentrations. Here, we review the use of optical nanopore sensing strategies for quantitative analysis. We discuss optical nanopore sensing assays that have been developed to detect clinically relevant biomarkers, the potential for multiplexing such measurements, and techniques to fabricate high density arrays of nanopores with a view toward the use of these devices for clinical applications.


Asunto(s)
Nanoporos , Nanotecnología
4.
Small ; 17(37): e2102543, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34337856

RESUMEN

Controlled breakdown has recently emerged as a highly appealing technique to fabricate solid-state nanopores for a wide range of biosensing applications. This technique relies on applying an electric field of approximately 0.4-1 V nm-1 across the membrane to induce a current, and eventually, breakdown of the dielectric. Although previous studies have performed controlled breakdown under a range of different conditions, the mechanism of conduction and breakdown has not been fully explored. Here, electrical conduction and nanopore formation in SiNx membranes during controlled breakdown is studied. It is demonstrated that for Si-rich SiNx , oxidation reactions that occur at the membrane-electrolyte interface limit conduction across the dielectric. However, for stoichiometric Si3 N4 the effect of oxidation reactions becomes relatively small and conduction is predominately limited by charge transport across the dielectric. Several important implications resulting from understanding this process are provided which will aid in further developing controlled breakdown in the coming years, particularly for extending this technique to integrate nanopores with on-chip nanostructures.


Asunto(s)
Nanoporos , Conductividad Eléctrica , Nanotecnología , Análisis de Secuencia por Matrices de Oligonucleótidos
5.
Chem Soc Rev ; 50(8): 4974-4992, 2021 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-33623941

RESUMEN

Nanopores in solid-state membranes are promising for a wide range of applications including DNA sequencing, ultra-dilute analyte detection, protein analysis, and polymer data storage. Techniques to fabricate solid-state nanopores have typically been time consuming or lacked the resolution to create pores with diameters down to a few nanometres, as required for the above applications. In recent years, several methods to fabricate nanopores in electrolyte environments have been demonstrated. These in situ methods include controlled breakdown (CBD), electrochemical reactions (ECR), laser etching and laser-assisted controlled breakdown (la-CBD). These techniques are democratising solid-state nanopores by providing the ability to fabricate pores with diameters down to a few nanometres (i.e. comparable to the size of many analytes) in a matter of minutes using relatively simple equipment. Here we review these in situ solid-state nanopore fabrication techniques and highlight the challenges and advantages of each method. Furthermore we compare these techniques by their desired application and provide insights into future research directions for in situ nanopore fabrication methods.

6.
Nanoscale ; 12(2): 871-876, 2020 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-31833518

RESUMEN

We analyze the noise in liquid-gated, room temperature, graphene quantum dots. These devices display extremely large noise amplitudes. The observed noise is explained in terms of a charge noise model by considering fluctuations in the applied source-drain and gate potentials. We show that the liquid environment and substrate have little effect on the observed noise and as such attribute the noise to charge trapping/detrapping at the disordered graphene edges. The trapping/detrapping of individual charges can be tuned by gating the device, which can result in stable two-level fluctuations in the measured current. These results have important implications for the use of electronic graphene nanodevices in single-molecule biosensing.


Asunto(s)
Grafito/química , Nanotecnología/instrumentación , Transistores Electrónicos , Técnicas Biosensibles/instrumentación , Simulación por Computador , Diseño de Equipo , Modelos Teóricos , Puntos Cuánticos/química , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA