Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
1.
JACC Cardiovasc Interv ; 17(12): 1517-1518, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38842997
2.
JACC Cardiovasc Imaging ; 17(7): 729-742, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38842961

RESUMEN

BACKGROUND: Tricuspid valve transcatheter edge-to-edge repair (T-TEER) is the most widely used transcatheter therapy to treat patients with tricuspid regurgitation (TR). OBJECTIVES: The aim of this study was to develop a simple anatomical score to predict procedural outcomes of T-TEER. METHODS: All patients (n = 168) who underwent T-TEER between January 2017 and November 2022 at 2 centers were included in the derivation cohort. Additionally, 126 patients from 2 separate institutions served as a validation cohort. T-TEER was performed using 2 commercially available technologies. Core laboratory assessment of procedural transesophageal echocardiograms was used to determine septolateral and anteroposterior coaptation gap, leaflet morphology, septal leaflet length and retraction, chordal structure density, tethering height, en face TR jet morphology and TR jet location, image quality, and the presence of intracardiac leads. A scoring system was derived using univariable and multivariable logistic regression. Endpoints assessed were immediate postprocedural TR reduction ≥2 grades and TR grade moderate or less. RESULTS: The median age was 82 years (Q1-Q3: 78-84 years); 48% of patients were women; and patients presented with severe (55%), massive (36%), and torrential (8%) TR. Five variables (septolateral coaptation gap, chordal structure density, en face TR jet morphology, TR jet location, and image quality) were identified as best predicting procedural outcome and were incorporated in the GLIDE (Gap, Location, Image quality, density, en-face TR morphology) score (range 0-5). TR reduction ≥2 grades and TR grade moderate or less were observed in >90% of patients with GLIDE scores of 0 and 1 and in only 5.6% and 16.7% of those with GLIDE scores ≥4. The GLIDE score was then externally validated in a separate cohort (area under the curve: 0.77; 95% CI: 0.69-0.86). TR reduction significantly correlated with functional improvement assessed by NYHA functional class and 6-minute walk distance at 3 months. CONCLUSIONS: The GLIDE score is a simple, 5-component score that is readily obtained during patient imaging and can predict successful T-TEER.


Asunto(s)
Cateterismo Cardíaco , Ecocardiografía Transesofágica , Valor Predictivo de las Pruebas , Recuperación de la Función , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Femenino , Masculino , Anciano , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/fisiopatología , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/fisiopatología , Válvula Tricúspide/cirugía , Resultado del Tratamiento , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Técnicas de Apoyo para la Decisión , Medición de Riesgo , Factores de Tiempo
3.
Int J Cardiol ; 411: 132233, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38848770

RESUMEN

BACKGROUND: Baseline right ventricular (RV) function derived from 3-dimensional analyses has been demonstrated to be predictive in patients undergoing transcatheter tricuspid valve repair (TTVR). The complex nature of these cumbersome analyses makes patient selection based on established imaging methods challenging. Artificial intelligence (AI)-driven computed tomography (CT) segmentation of the RV might serve as a fast and predictive tool for evaluating patients prior to TTVR. METHODS: Patients suffering from severe tricuspid regurgitation underwent full cycle cardiac CT. AI-driven analyses were compared to conventional CT analyses. Outcome measures were correlated with survival free of rehospitalization for heart-failure or death after TTVR as the primary endpoint. RESULTS: Automated AI-based image CT-analysis from 100 patients (mean age 77 ± 8 years, 63% female) showed excellent correlation for chamber quantification compared to conventional, core-lab evaluated CT analysis (R 0.963-0.966; p < 0.001). At 1 year (mean follow-up 229 ± 134 days) the primary endpoint occurred significantly more frequently in patients with reduced RV ejection fraction (EF) <50% (36.6% vs. 13.7%; HR 2.864, CI 1.212-6.763; p = 0.016). Furthermore, patients with dysfunctional RVs defined as end-diastolic RV volume > 210 ml and RV EF <50% demonstrated worse outcome than patients with functional RVs (43.7% vs. 12.2%; HR 3.753, CI 1.621-8.693; p = 0.002). CONCLUSIONS: Derived RVEF and dysfunctional RV were predictors for death and hospitalization after TTVR. AI-facilitated CT analysis serves as an inter- and intra-observer independent and time-effective tool which may thus aid in optimizing patient selection prior to TTVR in clinical routine and in trials.


Asunto(s)
Inteligencia Artificial , Tomografía Computarizada por Rayos X , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Masculino , Inteligencia Artificial/tendencias , Anciano , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Anciano de 80 o más Años , Tomografía Computarizada por Rayos X/métodos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Cateterismo Cardíaco/métodos , Estudios de Seguimiento , Implantación de Prótesis de Válvulas Cardíacas/métodos
4.
Clin Res Cardiol ; 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38695900

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PMI) is associated with increased morbidity after transcatheter aortic valve replacement (TAVR). Cardiac resynchronization-therapy (CRT) is recommended for patients if left ventricular ejection fraction (LVEF) is ≤ 40% and ventricular pacing is expected in favor to sole right ventricular (RV) pacing. Meanwhile, LVEF may recover after TAVR in patients with aortic valve disease and the benefit of CRT is unknown. OBJECTIVE: To analyze the impact of CRT implantation as compared to RV pacing after TAVR. METHODS AND RESULTS: Between 2012 and 2022, 4385 patients (53.1% female, mean age 81 ± 6 years) without prior PMI undergoing TAVR were retrospectively identified in our institutional registry. After stratification of patients in LVEF ≤ 40%, 41-49% and ≥ 50%, Kaplan-Meier analysis revealed significantly different survival rates in each subgroup at 5 years (37.0% vs. 43.5% vs. 55.1%; P ≤ 0.021). At multivariate regression, LVEF and new PMI after TAVR were not relevant for survival. A total of 105 patients with LVEF ≤ 40% received PMI after TAVR (86 patients with RV pacing and 19 with CRT). At 5 years, all-cause mortality was significantly lower in patients with CRT-device as compared to patients without CRT-device (Kaplan Meier estimate of 21.1% vs. 48.8%; HR 0.48, CI 0.204 - 1.128; log rank p = 0.045). In multivariate analysis CRT remained a significant factor for 5-year survival in these patients (HR 0.3, CI 0.095-0.951, p = 0.041). CONCLUSION: In patients undergoing TAVR, PMI did not influence 5-year survival. In patients with LVEF ≤ 40%, CRT-device implantation was associated with improved survival compared to non-CRT-device implantation.

5.
Clin Res Cardiol ; 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38358419

RESUMEN

BACKGROUND: Bleeding is the most common complication after percutaneous leaflet-based tricuspid valve repair and associated with acute kidney injury (AKI) and adverse outcome. TTVA with the Cardioband system is a technically more complex procedure; however, frequency and prognostic impact of postinterventional bleeding and renal complications have not been thoroughly examined. AIMS: This study was performed to determine the incidence and clinical impact of bleeding complications (MVARC criteria) and acute kidney injury (KDIGO criteria) following transcatheter tricuspid valve annuloplasty (TTVA). METHODS: In a bi-center retrospective analysis of patients undergoing TTVA between 2018 and 2022, we examined frequency, predictors, and clinical impact of bleeding and renal failure. RESULTS: In 145 consecutive patients, the incidence of any MVARC bleeding was 20.7% (n = 30), whereas major MVARC bleeding occurred in 6.9% (n = 10). The incidence of AKI was 18.6% (n = 27). Risk factors for bleeding events included low baseline hemoglobin and elevated baseline creatinine levels. Risk factors for AKI included diabetes mellitus, arterial hypertension, high body mass index, and elevated baseline creatinine levels. Neither procedure duration nor amount of contrast media was associated with AKI or bleeding. Both bleeding and AKI led to a longer hospital stay. At 3 months, 10.0% (n = 3) of patients with bleeding and 7.8% (n = 9) of patients without bleeding complications died (p = 0.70). Additionally, mortality rate was 7.4% (n = 2) in patients with AKI compared to 8.5% (n = 10) without AKI (p = 0.83). CONCLUSION: While about a fifth of patients undergoing TTVA suffered from postinterventional AKI or bleeding, none of these complications was associated with higher mortality at short-term follow-up. One important risk factor for both complications was chronic renal dysfunction, indicating a high-risk patient population. The most frequent bleeding localizations were the femoral access site, pericardial hemorrhage, and the esophagus, which need explicit attention in periprocedural management.

7.
J Clin Med ; 13(2)2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38256618

RESUMEN

Both the MitraClip and PASCAL systems offer transcatheter edge-to-edge repair (TEER) solutions for mitral regurgitation. Evidence indicates a lower technical success rate for TEER in complex degenerative mitral regurgitation (DMR) cases. We conducted a retrospective analysis of patients who underwent transcatheter edge-to-edge therapy for primary mitral regurgitation with advanced anatomy, defined as mitral regurgitation effective regurgitant orifice area (MR-EROA) ≥0.40 cm2 or large flail gap (≥5 mm) or width (≥7 mm) or Barlow's disease, that completed follow-up after 1 year. Our criteria were met by 27 patients treated with PASCAL and 18 with MitraClip. All patients exhibited a significant, equivalent short-term reduction in MR-EROA, mitral regurgitation vena contracta diameter (MR-VCD), regurgitant volume, and clinical status. At 1 year follow-up, reductions in MR-VCD, regurgitant volume, and MR-EROA remained significant for both groups without significant differences between groups. MR-Grade ≤ 1+ was achieved in 18 (66.7%) and 10 (55.6%) patients, respectively. At follow-up, no difference in hospitalization for cardiac decompensation was observed. Overall death was similar in both groups. Our study suggests that both the PASCAL and MitraClip systems significantly reduce mitral regurgitation even in advanced degenerative diseases. Within our limited data, we found no evidence of inferior performance of the PASCAL system.

8.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
9.
Eur Heart J Cardiovasc Imaging ; 25(4): 558-572, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37996066

RESUMEN

AIMS: Right ventricular to pulmonary artery (RV-PA) coupling has been established as a prognostic marker in patients with severe tricuspid regurgitation (TR) undergoing transcatheter tricuspid valve interventions (TTVI). RV-PA coupling assesses right ventricular systolic function related to pulmonary artery pressure levels, which are ideally measured by right heart catheterization. This study aimed to improve the RV-PA coupling concept by relating tricuspid annular plane systolic excursion (TAPSE) to mean pulmonary artery pressure (mPAP) levels. Moreover, instead of right heart catheterization, this study sought to employ an extreme gradient boosting (XGB) algorithm to predict mPAP levels based on standard echocardiographic parameters. METHODS AND RESULTS: This multicentre study included 737 patients undergoing TTVI for severe TR; among them, 55 patients from one institution served for external validation. Complete echocardiography and right heart catheterization data were available from all patients. The XGB algorithm trained on 10 echocardiographic parameters could reliably predict mPAP levels as evaluated on right heart catheterization data from external validation (Pearson correlation coefficient R: 0.68; P value: 1.3 × 10-8). Moreover, predicted mPAP (mPAPpredicted) levels were superior to echocardiographic systolic pulmonary artery pressure (sPAPechocardiography) levels in predicting 2-year mortality after TTVI [area under the curve (AUC): 0.607 vs. 0.520; P value: 1.9 × 10-6]. Furthermore, TAPSE/mPAPpredicted was superior to TAPSE/sPAPechocardiography in predicting 2-year mortality after TTVI (AUC: 0.633 vs. 0.586; P value: 0.008). Finally, patients with preserved RV-PA coupling (defined as TAPSE/mPAPpredicted > 0.617 mm/mmHg) showed significantly higher 2-year survival rates after TTVI than patients with reduced RV-PA coupling (81.5% vs. 58.8%, P < 0.001). Moreover, independent association between TAPSE/mPAPpredicted levels and 2-year mortality after TTVI was confirmed by multivariate regression analysis (P value: 6.3 × 10-4). CONCLUSION: Artificial intelligence-enabled RV-PA coupling assessment can refine risk stratification prior to TTVI without necessitating invasive right heart catheterization. A comparison with conservatively treated patients is mandatory to quantify the benefit of TTVI in accordance with RV-PA coupling.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Disfunción Ventricular Derecha , Humanos , Válvula Tricúspide , Arteria Pulmonar/diagnóstico por imagen , Inteligencia Artificial , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha
10.
Eur Heart J Cardiovasc Imaging ; 25(3): 365-372, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-37861385

RESUMEN

AIMS: Transcatheter tricuspid edge-to-edge repair (T-TEER) has gained widespread use for the treatment of tricuspid regurgitation (TR) in symptomatic patients with high operative risk. Although secondary TR is the most common pathology, some patients exhibit primary or predominantly primary TR. Characterization of patients with these pathologies in the T-TEER context has not been systematically performed. METHODS AND RESULTS: Patients assigned to T-TEER by the interdisciplinary heart team were consecutively recruited in two European centres over 4 years. Echocardiographic images were evaluated to distinguish between primary and secondary causes of TR. Both groups were compared concerning procedural results. A total of 339 patients were recruited, 13% with primary TR and 87% with secondary TR. Patients with primary TR had a smaller right ventricle (basal diameter 45 vs. 49 mm, P = 0.004), a better right ventricular function (fractional area change 45 vs. 41%, P = 0.001), a smaller right (28 vs. 34 cm2, P = 0.021) and left (52 vs. 67 mL/m2, P = 0.038) atrium, and a better left ventricular ejection fraction (60 vs. 52%, P = 0.005). The severity of TR was similar in primary and secondary TR at baseline (TR vena contracta width pre-interventional 13 ± 4 vs. 14 ± 5 mm, P = 0.19), and T-TEER significantly reduced TR in both groups (TR vena contracta width post-interventional 4 ± 3 vs. 5 ± 5 mm, P = 0.10). These findings remained stable after propensity score matching. Complications were similar between both groups. CONCLUSION: T-TEER confers equally safe and effective reduction of TR in patients with primary and secondary TR.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Prolapso de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Prolapso de la Válvula Tricúspide/etiología , Prolapso de la Válvula Tricúspide/cirugía , Volumen Sistólico , Estudios de Factibilidad , Resultado del Tratamiento , Función Ventricular Izquierda , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos
11.
J Am Heart Assoc ; 12(24): e031881, 2023 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-38084735

RESUMEN

BACKGROUND: We previously reported procedural and 30-day outcomes of a German early multicenter experience with the PASCAL system for severe mitral regurgitation (MR). This study reports 1-year outcomes of mitral valve transcatheter edge-to-edge repair with the PASCAL system according to MR etiology in a large all-comer cohort. METHODS AND RESULTS: Clinical and echocardiographic outcomes up to 1-year were investigated according to MR etiology (degenerative [DMR], functional [FMR], or mixed [MMR]) in the first 282 patients with symptomatic MR 3+/4+ treated with the PASCAL implant at 9 centers in 2019. A total of 282 patients were included (33% DMR, 50% FMR, 17% MMR). At discharge, MR reduction to ≤1+/2+ was achieved in 58%/87% of DMR, in 75%/97% of FMR, and in 78%/98% of patients with MMR (P=0.004). MR reduction to ≤1+/2+ was sustained at 30 days (50%/83% DMR, 67%/97% FMR, 74%/100% MMR) and at 1 year (53%/78% DMR, 75%/97% FMR, 67%/91% MMR) with significant differences between etiologies. DMR patients with residual MR 3+/4+ at 1-year had at least complex valve morphology in 91.7%. Valve-related reintervention was performed in 7.4% DMR, 0.7% FMR, and 0.0% MMR (P=0.010). At 1-year, New York Heart Association Functional Class was significantly improved irrespective of MR etiology (P<0.001). CONCLUSIONS: In this large all-comer cohort, mitral valve transcatheter edge-to-edge repair with the PASCAL system was associated with an acute and sustained MR reduction at 1-year in all causes. However, in patients with DMR, MR reduction was less pronounced, reflecting the high incidence of complex or very complex anatomies being referred for mitral valve transcatheter edge-to-edge repair.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Sistema de Registros , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/efectos adversos
12.
JACC Case Rep ; 16: 101874, 2023 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-37396318

RESUMEN

Transcatheter edge-to-edge repair (TEER) is the most widely used approach for tricuspid regurgitation in patients with prohibitive surgical risk. However, TEER might not be feasible in advanced tricuspid regurgitation. In such cases, a stepwise approach with initial annuloplasty and subsequent TEER can be a worthwhile alternative, which is reported in this series. (Level of Difficulty: Intermediate.).

13.
JACC Cardiovasc Interv ; 16(13): 1579-1589, 2023 07 10.
Artículo en Inglés | MEDLINE | ID: mdl-37438025

RESUMEN

BACKGROUND: Transcatheter tricuspid valve repair (TTVr) has significantly expanded treatment options for tricuspid regurgitation (TR). However, a sizeable proportion of patients are still declined for TTVr and little is known about their clinical characteristics and cardiac morphology. OBJECTIVES: This study sought to characterize patients who screen fail for TTVr with respect to their clinical characteristics and cardiac morphology. METHODS: A total of 547 patients were evaluated for TTVr between January 2016 to December 2021 from 3 centers in the United States and Germany. Clinical records and echocardiographic studies were used to assess medical history and right ventricular (RV) and tricuspid valve (TV) characteristics. RESULTS: Median age was 80 (IQR: 74-83) years and 60.0% were female. Over half (58.1%) were accepted for TTVr. Of those who were deemed unsuitable for TTVr (41.9%), the most common exclusion reasons were anatomical criteria (56.8%). In the regression analysis, RV and right atrial size, TV coaptation gap, and tethering area were identified as independent screen failure predictors. Other rejection reasons included clinical futility (17.9%), low symptom burden (12.7%), and technical limitations (12.7%). Most of the excluded patients (71.6%) were managed conservatively with medical therapy, while a small number either proceeded to TV surgery (22.3%) or subsequently became eligible for transcatheter tricuspid valve replacement in later available clinical trials in the United States (6.1%). CONCLUSIONS: The majority of TTVr screen failure patients are excluded due to TV, right atrial, and RV enlargement. However, a significant proportion is excluded due to clinical futility. These identifiable anatomical and clinical characteristics emphasize the importance of earlier referral and intervention of TR and the need for continued innovation of Transcatheter tricuspid valve interventions.


Asunto(s)
Apéndice Atrial , Ecocardiografía , Ventrículos Cardíacos , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Apéndice Atrial/diagnóstico por imagen , Estados Unidos , Alemania , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ventrículos Cardíacos/diagnóstico por imagen
15.
JACC Cardiovasc Interv ; 16(6): 693-702, 2023 03 27.
Artículo en Inglés | MEDLINE | ID: mdl-36990560

RESUMEN

BACKGROUND: Leaflet morphology has been associated with treatment success in edge-to-edge repair of tricuspid regurgitation (TR), but the impact on annuloplasty is unclear. OBJECTIVES: The authors sought to examine the association of leaflet morphology with efficacy and safety of direct annuloplasty in TR. METHODS: The authors analyzed patients who underwent catheter-based direct annuloplasty with the Cardioband at 3 centers. Leaflet morphology was assessed according to number and location of leaflets by echocardiography. Patients with simple morphology (2 or 3 leaflets) were compared with complex morphology (>3 leaflets). RESULTS: The study included 120 patients (median age 80 years) with ≥severe TR. A total of 48.3% of patients had a 3-leaflet morphology, 5% a 2-leaflet morphology, and 46.7% had >3 tricuspid leaflets. Baseline characteristics did not differ relevantly between groups except for a higher incidence of torrential TR grade (50 vs 26.6%) in complex morphologies. Postprocedural improvement of 1 (90.6% vs 92.9%) and 2 (71.9% vs 67.9%) TR grades was not significantly different between groups, but patients with complex morphology had more often residual TR ≥3 at discharge (48.2 vs 26.6%; P = 0.014). This difference did not remain significant (P = 0.112) after adjusting for baseline TR severity, coaptation gap, and nonanterior jet localization. Safety endpoints including complications of the right coronary artery, and technical success did not show significant differences. CONCLUSIONS: Efficacy and safety of transcatheter direct annuloplasty using Cardioband are not affected by leaflet morphology. Assessment of leaflet morphology should be part of procedural planning in patients with TR and might help to individually tailor repair techniques to patient anatomy.


Asunto(s)
Insuficiencia de la Válvula Tricúspide , Humanos , Anciano de 80 o más Años , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Válvula Mitral/cirugía , Ecocardiografía/efectos adversos
16.
J Am Heart Assoc ; 12(6): e028737, 2023 03 21.
Artículo en Inglés | MEDLINE | ID: mdl-36926925

RESUMEN

Background Tricuspid regurgitation (TR) frequently develops in patients with long-standing pulmonary hypertension, and both pathologies are associated with increased morbidity and mortality. This study aimed to improve prognostic assessment in patients with severe TR undergoing transcatheter tricuspid valve intervention (TTVI) by relating the extent of TR to pulmonary artery pressures. Methods and Results In this multicenter study, we included 533 patients undergoing TTVI for moderate-to-severe or severe TR. The proportionality framework was based on the ratio of tricuspid valve effective regurgitant orifice area to mean pulmonary artery pressure. An optimal threshold for tricuspid valve effective regurgitant orifice area/mean pulmonary artery pressure ratio was derived on 353 patients with regard to 2-year all-cause mortality and externally validated on 180 patients. Patients with a tricuspid valve effective regurgitant orifice area/mean pulmonary artery pressure ratio ≤1.25 mm2/mm Hg (defining proportionate TR) featured significantly lower 2-year survival rates after TTVI than patients with disproportionate TR (56.6% versus 69.6%; P=0.005). In contrast with patients with disproportionate TR (n=398), patients with proportionate TR (n=135) showed more pronounced mPAP levels (37.9±9.06 mm Hg versus 27.9±8.17 mm Hg; P<2.2×10-16) and more severely impaired right ventricular function (tricuspid annular plane systolic excursion: 16.0±4.11 versus 17.0±4.64 mm; P=0.012). Moreover, tricuspid valve effective regurgitant orifice area was smaller in patients with proportionate TR when compared with disproportionate TR (0.350±0.105 cm2 versus 0.770±0.432 cm2; P<2.2×10-16). Importantly, proportionate TR remained a significant predictor for 2-year mortality after adjusting for demographic and clinical variables (hazard ratio, 1.7; P=0.006). Conclusions The proposed proportionality framework promises to improve future risk stratification and clinical decision-making by identifying patients who benefit the most from TTVI (disproportionate TR). As a next step, randomized controlled studies with a conservative treatment arm are needed to quantify the net benefit of TTVI in patients with proportionate TR.


Asunto(s)
Hipertensión Pulmonar , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Pronóstico , Resultado del Tratamiento
17.
JACC Cardiovasc Interv ; 15(24): 2541-2551, 2022 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-36543448

RESUMEN

BACKGROUND: In addition to the edge-to-edge MitraClip repair system, the edge-to-spacer PASCAL repair system was approved for percutaneous treatment of severe mitral regurgitation (MR). Comparative data are lacking. OBJECTIVES: The aim of this study was to compare procedural and short-term safety and efficacy of 2 leaflet-based transcatheter mitral valve repair systems. METHODS: Procedural and 30-day outcomes were investigated in a propensity score-matched cohort of 307 PASCAL and 307 MitraClip patients at 10 sites. Matching criteria included sex, age, left ventricular ejection fraction, New York Heart Association functional class, MR etiology, left ventricular end-diastolic diameter, left atrial volume index, and vena contracta width. The primary efficacy endpoints were technical success and degree of residual MR at discharge. The primary safety endpoint was the rate of major adverse events (MAE). RESULTS: Technical success was 97.0% in the PASCAL group and 98.0% in the MitraClip group (P = 0.624). MR ≤2+ at discharge was comparable in both groups (PASCAL: 93.8% vs MitraClip: 92.4%; P = 0.527), with more patients exhibiting MR ≤1+ in the PASCAL group (70.5% vs 56.6%; P < 0.001). The postprocedural mean gradient was significantly higher in the MitraClip group (3.3 ± 1.5 mm Hg vs 3.9 ± 1.7 mm Hg; P < 0.001). At 30 days, all-cause mortality and MAE rates were similar (mortality: 1.7% vs 3.3%; P = 0.299; MAE: 3.9% vs 5.2%; P = 0.562). CONCLUSIONS: In this first large propensity score-matched comparison, procedural success rates and MAE did not differ significantly between patients treated with the PASCAL or MitraClip valve repair system. Procedural results with less than moderate MR and no elevated transmitral gradient were more common in the PASCAL group, which might have an impact on long-term outcome.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Volumen Sistólico , Puntaje de Propensión , Función Ventricular Izquierda , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos
18.
JACC Cardiovasc Interv ; 15(24): 2554-2567, 2022 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-36543450

RESUMEN

BACKGROUND: Since its introduction in 2003, Abbott's MitraClip (MC) has become the most established catheter-based treatment for mitral regurgitation (MR). Recent approval of Edwards Lifescience's PASCAL device has extended the field of TEER. OBJECTIVES: The aim of this retrospective multicenter study was to compare the PASCAL and MC regarding procedural results and short- and long-term outcomes after mitral valve transcatheter edge-to-edge repair (TEER). METHODS: Data from 3 high-volume centers were analyzed. The primary endpoint was residual MR at discharge. Secondary endpoints were technical success, MR reduction, and 30-day mortality. After 1 year, all-cause mortality and residual MR were reported. RESULTS: A total of 412 patients (216 MC, 196 PASCAL) treated between 2018 and 2020 were included. A total of 184 patients (92 in each treatment group) remained after propensity score matching. The rate of baseline MR ≥3 was 98.9% in both groups (P = 1.00). Both TEER systems achieved equally high technical success rates (97.8%; P = 1.00), resulting in residual MR ≤1 in 69.6% vs 77.1% of patients (P = 0.24) and MR reduction by ≥2 grades in 83.7% vs 92.4% of patients (P = 0.13) using the MC and PASCAL, respectively. Thirty-day mortality was 1.1% in both cohorts (P = 0.98), and 1-year follow-up showed similar MR reductions (residual MR ≤1, 78.0% with MC vs 82.3% with PASCAL; P = 0.70) and comparable all-cause mortality (14.1% with MC vs 6.5% with PASCAL; P = 0.14). In multivariate regression analysis, Society of Thoracic Surgeons score independently correlated with an optimal result (MR ≤1), while device choice did not show a significant impact. CONCLUSIONS: In this retrospective multicenter study, the established MC and the novel PASCAL mitral valve TEER systems were safe and offered excellent performance with comparable short- and long-term outcomes.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Puntaje de Propensión , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Cateterismo Cardíaco
20.
Catheter Cardiovasc Interv ; 100(7): 1291-1299, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36378678

RESUMEN

BACKGROUND: Severe tricuspid regurgitation (TR) is independently associated with increased morbidity and mortality. Percutaneous transcatheter approaches may offer an alternative for patients not amenable to surgery. METHODS: TriCLASP is a prospective, single-arm, multicenter European post-market clinical follow-up study (NCT04614402) to evaluate the safety and performance of the PASCAL system (Edwards Lifesciences) in patients with severe or greater TR. At 30 days, a composite of major adverse events (MAEs) adjudicated by a clinical events committee, echocardiographic parameters adjudicated by core laboratory, and clinical, functional, and quality-of-life measures were evaluated. RESULTS: Mean age of the 74 enrolled patients was 80.3 years, with 58.1% female, 90.5% systemic hypertension, and 77.0% in New York Heart Association (NYHA) class III/IV. Mean Society for Thoracic Surgeons score (MV repair) was 9.0%. TR severity was significantly reduced at discharge (p < 0.001) and sustained at 30 days (p < 0.001), and 90.0% of patients achieved ≤moderate TR. The composite MAE rate at 30 days was 3.0%, including 4 events in 2 patients: cardiovascular mortality 1.5%, stroke 1.5%, renal complications requiring unplanned dialysis or renal replacement therapy 1.5%, and severe bleeding 1.5%. There were no nonelective tricuspid valve reinterventions, major access site and vascular complications, major cardiac structural complications, or device embolizations. NYHA class I/II was achieved in 55.8%, 6-minute walk distance improved by 38.2 m (p < 0.001), and Kansas City cardiomyopathy questionnaire scores improved by 13.4 points (p < 0.001). CONCLUSION: Experience with the PASCAL transcatheter valve repair system in a European post-market setting confirms favorable safety and effectiveness at 30 days. TR significantly reduced, and clinical, functional, and quality-of-life outcomes significantly improved. This study is ongoing. Clinical Trial Registration: The study is ongoing and registered on ClinicalTrials.gov as NCT04614402. The current analysis is an interim report.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano de 80 o más Años , Masculino , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco , Estudios de Seguimiento , Estudios Prospectivos , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...