Clin Radiol ; 69(4): 363-71, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24424326

RESUMEN

AIM: To validate a newly developed software prototype that automatically analyses small bowel motility by comparing it directly with manual measurement. MATERIAL AND METHODS: Forty-five patients with clinical indication for small bowel magnetic resonance imaging (MRI) were retrospectively included in this institutional review board-approved study. MRI was performed using a 1.5 T system following a standard MR-enterography protocol. Small bowel motility parameters (contractions-per-minute, luminal diameter, amplitude) were measured three times each in identical segments using the manual and the semiautomatic software-assisted method. The methods were compared for agreement, repeatability, and time needed for each measurement. All parameters were compared between the methods. RESULTS: A total of 91 small-bowel segments were analysed. No significant intra-individual difference (p > 0.05) was found for peristaltic frequencies between the methods (mean: 4.14/min manual; 4.22/min software-assisted). Amplitudes (5.14 mm; 5.57 mm) and mean lumen diameters (17.39 mm; 14.68) differed due to systematic differences in the definition of the bowel wall. Mean duration of single measurement was significantly (p < 0.01) shorter with the software (6.25 min; 1.30 min). The scattering of repeated measurements was significantly (p < 0.05) lower using the software. CONCLUSION: The software-assisted method accomplished highly reliable, fast and accurate measurement of small bowel motility. Measurement precision and duration differed significantly between the two methods in favour of the software-assisted technique.


Asunto(s)
Motilidad Gastrointestinal , Interpretación de Imagen Asistida por Computador , Intestino Delgado/fisiopatología , Imagen por Resonancia Magnética , Programas Informáticos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Suiza/epidemiología
2.
Clin Radiol ; 68(11): 1121-7, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23932672

RESUMEN

AIM: To determine the feasibility of evaluating surgically induced hepatocyte damage using gadoxetate disodium (Gd-EOB-DTPA) as a marker for viable hepatocytes at magnetic resonance imaging (MRI) after liver resection. MATERIAL AND METHODS: Fifteen patients were prospectively enrolled in this institutional review board-approved study prior to elective liver resection after informed consent. Three Tesla MRI was performed 3-7 days after surgery. Three-dimensional (3D) T1-weighted (W) volumetric interpolated breath-hold gradient echo (VIBE) sequences covering the liver were acquired before and 20 min after Gd-EOB-DTPA administration. The signal-to-noise ratio (SNR) was used to compare the uptake of Gd-EOB-DTPA in healthy liver tissue and in liver tissue adjacent to the resection border applying paired Student's t-test. Correlations with potential influencing factors (blood loss, duration of intervention, age, pre-existing liver diseases, postoperative change of resection surface) were calculated using Pearson's correlation coefficient. RESULTS: Before Gd-EOB-DTPA administration the SNR did not differ significantly (p = 0.052) between healthy liver tissue adjacent to untouched liver borders [59.55 ± 25.46 (SD)] and the liver tissue compartment close to the resection surface (63.31 ± 27.24). During the hepatocyte-specific phase, the surgical site showed a significantly (p = 0.04) lower SNR (69.44 ± 24.23) compared to the healthy site (78.45 ± 27.71). Dynamic analyses revealed a significantly lower increase (p = 0.008) in signal intensity in the healthy tissue compared to the resection border compartment. CONCLUSION: EOB-DTPA-enhanced MRI may have the potential to be an effective non-invasive tool for detecting hepatocyte damage after liver resection.


Asunto(s)
Medios de Contraste/farmacocinética , Gadolinio DTPA/farmacocinética , Hepatocitos , Hepatopatías/diagnóstico , Hígado/cirugía , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Estudios de Factibilidad , Femenino , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Relación Señal-Ruido
3.
Clin Radiol ; 68(12): 1247-53, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23973163

RESUMEN

AIM: To evaluate the influence of locally active Crohn's disease on systemic small-bowel motility in patients with chronic Crohn's disease compared to healthy individuals. MATERIAL AND METHODS: Fifteen healthy individuals (11 men, four women; mean age 37 years) and 20 patients with histopathologically proven active (n = 15; 10 women, 5 men; mean age 45 years) or chronic (n = 5; four women, one man; mean age 48 years) Crohn's disease were included in this institutional review board-approved, retrospective study. Magnetic resonance imaging (MRI; 1.5 T) was performed after standardized preparation. Two-dimensional (2D) cine sequences for motility acquisition were performed in apnoea (27 s). Motility assessment was performed using dedicated software in three randomly chosen areas of the small-bowel outside known Crohn's disease-affected hotspots. The main quantitative characteristics (frequency, amplitude, occlusion rate) were compared using Student's t-test and one-way analysis of variance (ANOVA). RESULTS: Three randomly chosen segments were analysed in each participant. Patients with active Crohn's disease had significantly (p < 0.05) reduced contraction frequencies (active Crohn's disease: 2.86/min; chronic: 4.14/min; healthy: 4.53/min) and luminal occlusion rates (active: 0.43; chronic: 0.70; healthy: 0.73) compared to healthy individuals and patients with chronic Crohn's disease. Contraction amplitudes were significantly reduced during active Crohn's disease (6.71 mm) compared to healthy participants (10.14 mm), but this only reached borderline significance in comparison to chronic Crohn's disease (8.87 mm). Mean bowel lumen diameter was significantly (p = 0.04) higher in patients with active Crohn's disease (16.91 mm) compared to healthy participants (14.79 mm) but not in comparison to patients with chronic Crohn's disease (13.68). CONCLUSION: The findings of the present study suggest that local inflammatory activity of small-bowel segments in patients with active Crohn's disease alters small-bowel motility in distant, non-affected segments. The motility patterns revealed reduced contraction-wave frequencies, amplitudes, and decreased luminal occlusion rates. Thus evaluation of these characteristics potentially helps to differentiate between chronic and active Crohn's disease.


Asunto(s)
Enfermedad de Crohn/patología , Motilidad Gastrointestinal , Imagen por Resonancia Cinemagnética , Adulto , Anciano , Anciano de 80 o más Años , Estudios de Casos y Controles , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/fisiopatología , Femenino , Humanos , Íleon/patología , Íleon/fisiopatología , Intestino Delgado/patología , Intestino Delgado/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
4.
Neurogastroenterol Motil ; 25(9): 749-e577, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23741963

RESUMEN

BACKGROUND: The objective of the study was to correlate MR-detectable motility alterations of the terminal ileum with biopsy-documented active and chronic changes in Crohn's disease. METHODS: This IRB approved retrospective analysis of 43 patients included magnetic resonance enterography (MRE) and terminal ileum biopsies (<2 weeks apart). Motility was measured at the terminal ileum using coronal 2D trueFISP pulse sequences (1.5T MRI,TR 83.8,TE1.89) and dedicated motility assessment software. Motility grading (hypermotility, normal, hypomotility, complete arrest) was agreed by two experienced readers. Motility was compared and correlated with histopathology using two-tailed Kruskal-Wallis test and paired Spearman Rank-Order Correlation tests. KEY RESULTS: Motility abnormalities were present in 27/43 patients: nine hypomotility and 18 complete arrest. Active disease was diagnosed on 15 biopsies: eight moderate and seven severe inflammatory activity. Chronic changes were diagnosed on 17 biopsies: 13 moderate and four severe cases. In four patients with normal motility alterations on histopathology were diagnosed. Histopathology correlated with presence (P = 0.0056 for hypomotility and P = 0.0119 for complete arrest) and grade (P < 0.0001; P = 0.0004) of motility alterations. A significant difference in the motility was observed in patients with active or chronic CD compared with patients without disease (P < 0.001; P = 0.0024). CONCLUSIONS & INFERENCES: MR-detectable motility changes of the terminal ileum correlate with histopathological findings both in active and chronic CD. Motility changes may indicate the presence pathology, but do not allow differentiation of active and chronic disease.


Asunto(s)
Enfermedad de Crohn/patología , Enfermedad de Crohn/fisiopatología , Motilidad Gastrointestinal/fisiología , Íleon/patología , Íleon/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto Joven
5.
Neurogastroenterol Motil ; 25(6): 467-73, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23495824

RESUMEN

BACKGROUND: To evaluate the correlation between the levels of C-reactive protein (CRP), calprotectin, and small bowel motility in patients with Crohn's disease assessed with MRI. METHODS: This prospective institutional review board approved study included magnetic resonance imaging enterography (MRE) and analyses of inflammatory markers in blood (C-reactive protein) and feces (calprotectin). For cine MRE, a coronal 2D-T2w sequence was used on a 1.5 T MRI system. Small bowel motility was analyzed in 13 patients using dedicated magnetic resonance MR-motility assessment software (Motasso). Contraction frequency, amplitude, amplitude diameter ratio, and luminal diameter were determined as well as the blood levels of CRP (mg L(-1) ) and fecal levels of calprotectin (ug g(-1) ). Statistics were calculated using Pearson's correlation coefficient. KEY RESULTS: A significant inverse linear correlation was found between the contraction frequency and both the level of CRP (r = -0.701, P = 0.008) and calprotectin (r = -0.805, P = 0.001). Dilatation of small bowel diameter significantly correlated with calprotectin levels (r = 0.857, P =< 0.001) but not with CRP (r = 0.447, P = 0.126). The absolute amplitude of the contractions did not correlate neither with the level of CRP (r = -0.527, P = 0.064) nor with calprotectin (r = -0.612, P = 0.026). The ratio describing the contraction amplitude relatively to the individual luminal diameter significantly correlated with calprotectin (r = 0.736, P = 0.004) and with CRP (r = 0.577, P = 0.039). CONCLUSIONS & INFERENCES: Alterations of small bowel motility during CD flares significantly correlate with the level of calprotectin and CRP indicating that they represent inflammatory activity.


Asunto(s)
Proteína C-Reactiva/análisis , Enfermedad de Crohn/fisiopatología , Motilidad Gastrointestinal/fisiología , Intestino Delgado/fisiopatología , Complejo de Antígeno L1 de Leucocito/análisis , Adulto , Anciano , Proteína C-Reactiva/metabolismo , Enfermedad de Crohn/metabolismo , Enfermedad de Crohn/patología , Heces/química , Femenino , Humanos , Inflamación/metabolismo , Inflamación/patología , Inflamación/fisiopatología , Intestino Delgado/patología , Complejo de Antígeno L1 de Leucocito/metabolismo , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Índice de Severidad de la Enfermedad
6.
Eur Radiol ; 21(4): 807-15, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-20890705

RESUMEN

OBJECTIVES: To evaluate whether induced dental pain leads to quantitative changes in brain metabolites within the left insular cortex after stimulation of the right maxillary canine and to examine whether these metabolic changes and the subjective pain intensity perception correlate. METHODS: Ten male volunteers were included in the pain group and compared with a control group of 10 other healthy volunteers. The pain group received a total of 87-92 electrically induced pain stimuli over 15 min to the right maxillary canine tooth. Contemporaneously, they evaluated the subjective pain intensity of every stimulus using an analogue scale. Neurotransmitter changes within the left insular cortex were evaluated by MR spectroscopy. RESULTS: Significant metabolic changes in glutamine (+55.1%), glutamine/glutamate (+16.4%) and myo-inositol (-9.7%) were documented during pain stimulation. Furthermore, there was a significant negative correlation between the subjective pain intensity perception and the metabolic levels of Glx, Gln, glutamate and N-acetyl aspartate. CONCLUSION: The insular cortex is a metabolically active region in the processing of acute dental pain. Induced dental pain leads to quantitative changes in brain metabolites within the left insular cortex resulting in significant alterations in metabolites. Negative correlation between subjective pain intensity rating and specific metabolites could be observed.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Dolor/patología , Nervio Trigémino/patología , Adulto , Ácido Aspártico/análogos & derivados , Ácido Aspártico/metabolismo , Corteza Cerebral/patología , Electrodos , Femenino , Ácido Glutámico/metabolismo , Glutamina/metabolismo , Humanos , Inositol/metabolismo , Masculino , Persona de Mediana Edad , Modelos Anatómicos , Neurotransmisores/metabolismo , Estudios Prospectivos , Protones , Enfermedades Dentales/patología
7.
Eur Radiol ; 20(8): 1926-33, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20309560

RESUMEN

OBJECTIVE: To report the results and implications for workflow following introduction of ESUR guidelines to screen for potential renal insufficiency (RI) in private practice with on-site creatinine measurements. METHODS: A total of 1,766 consecutive outpatients scheduled for contrast-enhanced CT (CECT) completed the ESUR questionnaire enquiring about kidney disease, renal surgery, proteinuria, diabetes mellitus, hypertension, gout or use of nephrotoxic drugs. Patients with positive risk factors underwent on-site creatinine measurement and calculation of estimated glomerular filtration rate (eGFR). Attending radiologists adapted subsequent imaging depending on renal function and presence of risk factors. RESULTS: One or more ESUR risk factors were present in 796 (45.1%) patients, including hypertension (37.7%), nephrotoxic medication (21.3%), diabetes mellitus (8.0%), proteinuria (3.9%), renal disease (4.1%), gout (3.1%) and renal surgery (2.6%). Pre-procedural creatinine measurements revealed severe RI (eGFR < 30 ml min(-1) 1.73 m(-2)) in 10 (1.3%) and moderate RI (eGFR 30-59 ml min(-1) 1.73 m(-2)) in 106 (13.8%). Imaging work-up was adapted in 132 (16.6%) as follows: reduction of contrast material dose (n = 85), CT without contrast (n = 40), changeover to MRI (n = 3) or scintigraphy (n = 4). CONCLUSION: Screening for RI following ESUR guidelines requires creatinine measurements in nearly half of outpatients scheduled for CECT and reveals moderate to severe renal impairment in 6.6%.


Asunto(s)
Creatinina/sangre , Tamizaje Masivo/estadística & datos numéricos , Tamizaje Masivo/normas , Guías de Práctica Clínica como Asunto , Insuficiencia Renal/sangre , Insuficiencia Renal/diagnóstico , Encuestas y Cuestionarios/normas , Atención Ambulatoria/normas , Atención Ambulatoria/estadística & datos numéricos , Biomarcadores/sangre , Europa (Continente) , Femenino , Humanos , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Pacientes Ambulatorios/estadística & datos numéricos , Prevalencia , Insuficiencia Renal/epidemiología , Medición de Riesgo/métodos , Medición de Riesgo/normas , Factores de Riesgo , Suiza/epidemiología , Tomografía Computarizada por Rayos X/estadística & datos numéricos
8.
Eur Radiol ; 19(7): 1715-22, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19330333

RESUMEN

The aim of this study was to compare signal characteristics of the synovium in knees of asymptomatic volunteers before and after intravenous administration of ultrasmall superparamagnetic iron oxide particles (USPIO). Ten knees of 10 asymptomatic volunteers were examined before and 36 h after intravenous administration of USPIO on a 1.5-T MR system using T1-weighted spin-echo, T2-weighted fast spin-echo, T2*-weighted gradient-echo (GRE), and short inversion time inversion-recovery sequences. In addition, synovial perfusion was measured using Gd-enhanced GRE imaging during the first imaging session. Images were analyzed qualitatively for any visual changes before and after USPIO administration. Signal-to-noise ratios (SNR) of the synovium were determined on unenhanced and USPIO-enhanced sequences. All MR images were reviewed for presence of any degenerative changes. Qualitative image analysis revealed no visually detectable changes of any knee joint before and after USPIO administration. The SNR values of the synovium on T1w, T2w, and T2*w images before and after USPIO administration showed no significant difference (T1, P = 0.86; T2, P = 0.95; T2*, P = 0.86). None of the volunteers showed any relevant degenerative changes of the knee and synovial perfusion was within normal limits. In knees of asymptomatic volunteers without any relevant degenerative changes and normal synovial perfusion neither visual changes nor changes of SNR values of the synovium can be depicted after USPIO administration. This means that USPIO-enhanced MRI may be used for assessment of knee disorders with increased macrophage activity.


Asunto(s)
Aumento de la Imagen/métodos , Hierro , Articulación de la Rodilla/anatomía & histología , Rodilla/anatomía & histología , Imagen por Resonancia Magnética/métodos , Óxidos , Adulto , Medios de Contraste , Dextranos , Femenino , Óxido Ferrosoférrico , Humanos , Nanopartículas de Magnetita , Masculino , Persona de Mediana Edad , Valores de Referencia , Adulto Joven
9.
Eur Radiol ; 15(9): 1797-805, 2005 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15875194

RESUMEN

The purpose of this work was to compare the diagnostic performance of a single-contrast or a double-contrast dose of carotid contrast-enhanced MR angiography (MRA). One-hundred nineteen patients (mean age 65+/-14.4 years) underwent carotid contrast-enhanced MRA with a standardized protocol (repetition time/echo 3.73 ms/1.38 ms, flip-angle 25 degrees, acquisition-time 19 s, voxel size 1.2 x 1.2 x 0.9 mm3) on a 1.5-T scanner (Sonata, Siemens-Medical-Systems) using a neck phased-array coil. Contrast agent was administered intravenously at a rate of 3.0 ml/s, either as a single dose (n=57; 0.1 mmol/kg body weight) or as a double dose (n=62; 0.2 mmol/kg body weight) of meglumine gadoterate (0.5 M/l), followed by 30 ml saline. Qualitative image analysis was performed on maximum intensity projections using a five-point scale. Signal intensities were measured at three different vascular levels on both sides to assess the contrast-to-noise ratios (CNRs). Image quality was rated as good or excellent in all cases. A double dose did not influence the efficacy of carotid enhancement (CNR single dose 69.12+/-19.8; CNR double dose 70.01+/-20.7; p = 0.81) compared with a single dose. In both dose groups the mean CNRs were inversely related to bodyweight, despite adjusted contrast volumes (p=0.0005). Double-dose contrast-enhanced carotid MRA is not superior to single-dose MRA, as overall diagnostic performance and quantitative contrast enhancement are equal. Being more cost-efficient, a single-dose administration of contrast agent is recommended for MRA of the carotid arteries.


Asunto(s)
Arterias Carótidas/patología , Medios de Contraste/administración & dosificación , Aumento de la Imagen/métodos , Angiografía por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estenosis Carotídea/diagnóstico , Femenino , Gadolinio/administración & dosificación , Compuestos Heterocíclicos/administración & dosificación , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Estudios Prospectivos , Accidente Cerebrovascular/diagnóstico
10.
Lancet ; 358(9286): 987-8, 2001 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-11583757

RESUMEN

Magnetic resonance enteroclysis is a promising technique that allows assessment of the small bowel but needs invasive nasoduodenal intubation. We propose a non-invasive distension method for magnetic-resonance imaging (MRI) in which ispaghula, dissolved in an aqueous solution with meglumine gadoterate taken orally over 4 h forms a viscous hydrogel within the intestinal lumen. MRI results from ten volunteers showed good luminal distension, constant signal homogeneity, optimum demarcation of the bowel content from surrounding tissues, and a low rate of artefacts. Our method permits non-invasive high quality MRI of the small bowel.


Asunto(s)
Catárticos/farmacología , Intestino Delgado/efectos de los fármacos , Imagen por Resonancia Magnética/métodos , Psyllium/farmacología , Adulto , Femenino , Humanos , Enfermedades Intestinales/diagnóstico , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...