Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
1.
Clin Rehabil ; 37(12): 1670-1683, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37350084

RESUMEN

OBJECTIVE: This study presents the walking abilities of participants fitted with transfemoral bone-anchored prostheses using a total of 14 gait parameters. DESIGN: Two-centre retrospective cross-sectional comparative study. SETTING: Research facilities equipped with tridimensional motion capture systems. PARTICIPANTS: Two control arms included eight able-bodied participants arm (54 ± 9 years, 1.75 ± 0.07 m, 76 ± 7 kg) and nine participants fitted with transfemoral socket-suspended prostheses arm (59 ± 9 years, 1.73 ± 0.07 m, 80 ± 16 kg). The intervention arm included nine participants fitted with transfemoral bone-anchored prostheses arm (51 ± 13 years, 1.78 ± 0.09 m, 87.3 ± 16.1 kg). INTERVENTION: Fitting of transfemoral bone-anchored prostheses. MAIN MEASURES: Comparisons were performed for two spatio-temporal, three spatial and nine temporal gait parameters. RESULTS: The cadence and speed of walking were 107 ± 6 steps/min and 1.23 ± 0.19 m/s for the able-bodied participants arm, 88 ± 7 steps/min and 0.87 ± 0.17 m/s for the socket-suspended prosthesis arm, and 96 ± 6 steps/min and 1.03 ± 0.17 m/s for bone-anchored prosthesis arm, respectively. Able-bodied participants and bone-anchored prosthesis arms were comparable in age, height, and body mass index as well as cadence and speed of walking, but the able-bodied participant arm showed a swing phase 31% shorter. Bone-anchored and socket-suspended prostheses arms were comparable for age, height, mass, and body mass index as well as cadence and speed of walking, but the bone-anchored prosthesis arm showed a step width and duration of double support in seconds 65% and 41% shorter, respectively. CONCLUSIONS: Bone-anchored and socket-suspended prostheses restored equally well the gait parameters at a self-selected speed. This benchmark data provides new insights into the walking ability of individuals using transfemoral bionics bone-anchored prostheses.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Humanos , Amputación Quirúrgica , Estudios Retrospectivos , Estudios Transversales , Marcha , Caminata , Fenómenos Biomecánicos , Diseño de Prótesis
2.
J Sci Med Sport ; 26 Suppl 1: S22-S29, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36878761

RESUMEN

OBJECTIVES: There is a need for diagnostic devices that can assist prosthetic care providers to better assess and maintain residuum health of individuals suffering from neuromusculoskeletal dysfunctions associated with limb loss. This paper outlines the trends, opportunities, and challenges that will facilitate the development of next-generation diagnostic devices. DESIGN: Narrative literature review. METHODS: Information about technologies suitable for integration into next-generation diagnostic devices was extracted from 41 references. We considered the invasiveness, comprehensiveness, and practicality of each technology subjectively. RESULTS: This review highlighted a trend toward future diagnostic devices of neuromusculoskeletal dysfunctions of the residuum capable to support evidence-based patient-specific prosthetic care, patient empowerment, and the development of bionic solutions. This device should positively disrupt the organization healthcare by enabling cost-utility analyses (e.g., fee-for-device business models) and addressing healthcare gaps due to labor shortages. There are opportunities to develop wireless, wearable and noninvasive diagnostic devices integrating wireless biosensors to measure change in mechanical constraints and topography of residuum tissues during real-life conditions as well as computational modeling using medical imaging and finite element analysis (e.g., digital twin). Developing the next-generation diagnostic devices will require to overcome critical barriers associated with the design (e.g., gaps between technology readiness levels of essential parts), clinical roll-out (e.g., identification of primary users), and commercialization (e.g., limited interest from investors). CONCLUSIONS: We anticipate that next-generation diagnostic devices will contribute to prosthetic care innovations that will safely increase mobility, thereby improving the quality of life of the growing global population of individuals suffering from limb loss.


Asunto(s)
Calidad de Vida , Humanos , Simulación por Computador
4.
Data Brief ; 41: 107936, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35242918

RESUMEN

The data in this paper are related to the research article entitled "Load applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with state-of-the-art prosthetic components" (Frossard et al. Clinical Biomechanics, 89 (2021) 105457. DOI: 10.1016/j.clinbiomech.2021.105457). This article contains the overall and individual loading characteristics applied on transfemoral press-fit osseointegrated implant generated by bone-anchored prostheses fitted with state-of-the-art components during daily activities (i.e., microprocessor-controlled Rheo Knee XC knee, energy-storing-and-returning Pro-Flex XC or LP feet (ÖSSUR, Iceland)). Confounders of the loads are presented. The load profiles are characterized by the loading patterns, loading boundaries and loading local extrema of the forces and moments applied during straight-level walking, ascending and descending ramp and stairs at self-selected comfortable pace. The confounders of the loading information as well as new insights into inter-participants variability of loading patterns, loading boundaries and loading local extrema can inform the design of subsequent cross-sectional and longitudinal studies as well as literature reviews and meta-analyzes. The loading datasets are critical to clinicians and engineers designing finite element models of osseointegrated implants (e.g., medullar and percutaneous parts) and prosthetic components, algorithms capable to recognize the loading patterns applied on a residuum during daily activities, as well as clinical trials assessing the effects of particular prosthetic care interventions. Altogether, these datasets provide promoters of prosthetic care innovations with valuable insights informing the prescription of advanced prosthetic components to the growing population of individuals suffering from lower limb loss choosing bionics solutions. Online repository contains the files: https://data.mendeley.com/datasets/gmsyv97cpc/1.

5.
Clin Biomech (Bristol, Avon) ; 89: 105457, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34454327

RESUMEN

BACKGROUND: This study presented the load profile applied on transfemoral osseointegrated implants by bone-anchored prostheses fitted with state-of-the-art ÖSSUR microprocessor-controlled Rheo Knee XC and energy-storing-and-returning Pro-Flex XC or LP feet during five standardized daily activities. METHODS: This cross-sectional cohort study included 13 participants fitted with a press-fit transfemoral osseointegrated implant. Loading data were directly measured with the tri-axial transducer of an iPecsLab (RTC Electronics, USA) fitted between the implant and knee unit. The loading profile was characterized by spatio-temporal gaits variables, magnitude of loading boundaries as well as onset and magnitude of loading extrema during walking, ascending and descending ramp and stairs. FINDINGS: A total of 2127 steps was analysed. The cadence ranged between 36 ± 7 and 47 ± 6 strides/min. The absolute maximum force and moments applied across all activities was 1322 N, 388 N and 133 N as well as 22 Nm, 52 Nm and 88 Nm on and around the long, anteroposterior and mediolateral axes of the implant, respectively. INTERPRETATION: This study provided new benchmark loading data applied by transfemoral bone-anchored prostheses fitted with selected ÖSSUR state-of-the-art components. Outcomes suggested that such prostheses can generate relevant loads at the interface with the osseointegrated implant to restore ambulation effectively. This study is a worthwhile contribution toward a systematic recording, analysis, and reporting of ecological prosthetic loading profiles as well as closing the evidence gaps between prescription and biomechanical benefits of state-of-the-art components. Hopefully, this will contribute to improve outcomes for growing number of individuals with limb loss opting for bionic solutions.


Asunto(s)
Amputados , Miembros Artificiales , Prótesis Anclada al Hueso , Amputación Quirúrgica , Estudios Transversales , Humanos , Oseointegración
6.
Mil Med ; 186(Suppl 1): 681-687, 2021 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-33499512

RESUMEN

INTRODUCTION: Osseointegrated implants for direct skeletal attachment of transtibial prosthesis carry risks that are yet to be fully resolved, such as early loosening, mechanical failure of percutaneous and medullar parts of implant, periprosthetic issues, and infections. Underloading could lead to early loosening and infection. Overloading might compromise the bone-implant interface. Therefore, Goldilocks loading regimen applied by transtibial bone-anchored prostheses is critical for safe and efficient development of osseointegration around the implant during rehabilitation and beyond. We hypothesized that Goldilocks loading could be achieved when ambulating with a so-called anthropomorphic prosthetic ankle showing moment-angle relationship similar to a sound ankle. MATERIALS AND METHODS: Quantitative characteristics of the moment-angle curve of the sound ankle during dorsiflexion phase of a free-pace walking were extracted for 4 able-bodied participants (experiment 1). A slope of the moment-angle curve (stiffness) was calculated twice: for the first half and for the second half of the moment-angle curve. The difference of stiffnesses (those at the second half minus at the first half) was called the index of anthropomorphicity (IA). By definition, positive IA is associated with concave shape of the moment-angle curve, and the negative IA is associated with convex shape. In experiment 2, the same recordings and calculations were performed for 3 participants fitted with transtibial osseointegrated fixation during walking with their usual feet and the Free-Flow Foot (Ohio Willow Wood). The Free-Flow Foot was selected for its anthropomorphicity demonstrated in the previous studies with amputees using traditional socket attachment. RESULTS: The IA was 5.88 ± 0.93 for the able-bodied participants, indicating that the stiffness during the first part of the dorsiflexion phase was substantially fewer than during the second parts, as the calf muscles resisted to angulation in ankle substantially less than during the second part of dorsiflexion phase. For amputees fitted with Free-Flow Foot, IA was 2.68 ± 1.09 and -2.97 ± 2.37 for the same amputees fitted with their usual feet. CONCLUSIONS: Indexes of anthropomorphicity, while of different magnitude, were positive in control able-bodied group and in the amputee group wearing Free-Flow Foot, which was qualitatively associated with concave shape of their moment-angle curves. The 3 usual feet worn by the participants were classified as nonanthropomorphic as their individual moment-angle curves were convex and the corresponding IAs were negative. Furthermore, this study showed that a foot with anthropomorphic characteristics tends to decrease maximal loads at the bone-implant interface as compared to the nonanthropomorphic feet and possibly may minimize the risks to compromise the integrity of this interface.


Asunto(s)
Prótesis Anclada al Hueso , Amputados , Miembros Artificiales , Fenómenos Biomecánicos , Marcha , Humanos , Ohio , Caminata
8.
Acta Bioeng Biomech ; 22(2): 69-81, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32868951

RESUMEN

PURPOSE: This study attempted to establish the link between design of implants for bone-anchored prostheses and stress-shielding, affecting the stability of the bone-implant coupling using numerical approach. The objectives were to share a numerical model capable to evaluate the long-term stability of implants and to use this model to extract data sets showing how shape and material stiffness of threaded, press-fit and modular press-fit implants affect stress-shielding intensity. METHODS: Three designs were considered: threaded, press-fit and modular press-fit. The effect of shape and material stiffness of each design on stress-shielding intensity was assessed using Young's modulus (10 to 210 GPa). Furthermore, the impact of the diameter of percutaneous part (10 to 18 mm) and thickness of medullar part (5 to 1 mm) was investigated for the modular press-fit implant. RESULTS: The threaded design generated 4% more bone mass loss at the distal femur but an overall loss of bone mass was by 5% lower to press-fit design. The influence of Young's modulus on bone mass changes was noticeable for modular press-fit implant, depending on diameter of percutaneous or medullary part. A 20 GPa change of stiffness caused a bone mass change from 0.65% up to 2.45% and from 0.07% up to 0.32% for percutaneous parts with 18 mm and 10 mm diameter, respectively. CONCLUSIONS: Results suggested that threaded implant provides greater stability despite an increased bone loss at the distal femur. Altogether, this work provided an initial model that could be applied in subsequent studies on the long-term stability of current and upcoming implants.


Asunto(s)
Benchmarking , Prótesis Anclada al Hueso , Ensayo de Materiales , Análisis Numérico Asistido por Computador , Oseointegración , Estrés Mecánico , Remodelación Ósea/fisiología , Huesos/anatomía & histología , Huesos/fisiología , Simulación por Computador , Módulo de Elasticidad , Análisis de Elementos Finitos , Humanos , Tamaño de los Órganos
9.
Data Brief ; 26: 104492, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31667256

RESUMEN

The data in this paper are related to the research articles entitled "Kinetics of transfemoral amputees with osseointegrated fixation performing common activities of daily living" (Lee et al., Clinical Biomechanics, 2007.22(6). p. 665-673) and "Magnitude and variability of loading on the osseointegrated implant of transfemoral amputees during walking" (Lee et al., Med Eng Phys, 2008.30(7). p. 825-833). This article contains the overall and individual loading characteristics applied on screw-type osseointegrated implant generated by transfemoral bone-anchored prostheses fitted with basic components during daily activities at self-selected comfortable pace. Overall and individual data was presented for the (A) spatio-temporal characteristics, (B) loading patterns, (C) loading boundaries and (D) the loading local extremum during level walking, ascending and descending ramp and stairs. Inter-participant variability of these new datasets with basic components is critical to improve the efficacy and safety of prosthetic components as well as the design of future automated algorithms and clinical trials. Online repository contains the files: https://data.mendeley.com/datasets/hh8rjjh73w/1.

10.
Data Brief ; 26: 104510, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31667273

RESUMEN

The data in this paper are related to the research article entitled "Loading applied on osseointegrated implant by transtibial bone-anchored prostheses during daily activities: Preliminary characterization of prosthetic feet" (Frossard et al., 2019: Accepted). This article contains the individual and grouped loading characteristics applied on transtibial osseointegrated implant generated while walking with bone-anchored prostheses including prosthetic feet with different index of anthropomorphicity. Inter-participant variability was presented for (A) the spatio-temporal characteristics, (B) the loading boundaries and (C) the loading local extremum during walking, ascending and descending ramp and stairs. These initial inter-participant variability benchmark datasets are critical to improve the efficacy and safety of prosthetic components for transtibial prostheses as well as the design of future automated algorithms and clinical trials. Online repository contains the files: https://doi.org/10.17632/vhc6sf7ngy.1.

11.
Data Brief ; 26: 104536, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31667297

RESUMEN

The data in this paper are related to the research article entitled "Development of a government continuous quality improvement procedure for assessing the provision of bone anchored limb prosthesis: A process re-design descriptive study" (Frossard et al., Canadian Prosthetics & Orthotics Journal, 2018. 1(2). p. 1-14). This article contains quality of life data experienced by individuals before and after implantation of a press-fit or screw-type osseointegrated fixation when fitted with conventional socket-suspended and bone-anchored limb prosthesis, respectively. This specifically-designed survey was developed and administered by Queensland Artificial Limb Services (QALS), an Australian State government organization. It was an integrated part of QALS' continuous quality improvement procedure for assessing the provision of bone-anchored prosthesis. A total of 12 out of the 65 consumers completed to the survey, giving a return rate of 18%. This benchmark information can contribute to inform the design of (A) other patients' experience surveys including those built-in governmental continuous quality improvement procedure as well as (B) clinical trials looking at the overall effects of surgical implantation of ossoeintegrated fixation on patients' quality of life. Online repository contains the files: https://data.mendeley.com/datasets/bkbxxmrhfh/1.

12.
Data Brief ; 25: 104195, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31406899

RESUMEN

The data in this paper are related to the research article entitled "Automated characterization of anthropomorphicity of prosthetic feet fitted to bone-anchored transtibial prosthesis" (Frossard et al., 2019: DOI: 10.1109/TBME.2019.2904713). This article contains the individual angles of dorsiflexion and bending moments generated while walking with transtibial bone-anchored prostheses including prosthetic feet with different index of anthropomorphicity. Inter-participant variability were presented for the (A) position of the load cell measuring directly to the bending moments, (B) patterns of angles of dorsiflexion and bending moment as well as moment-angle curves and (C) variations of magnitude of angles of dorsiflexion as well as the raw and bodyweight-normalized bending moments between toe contact and heel off. These initial inter-participant variability benchmark datasets are critical to design future automated algorithms and clinical trials. Online repository contains the files: https://eprints.qut.edu.au/127745/1/127745.pdf.

13.
Artículo en Inglés | MEDLINE | ID: mdl-30872221

RESUMEN

OBJECTIVE: This study describes differentiating prosthetic feet designs fitted to bone-anchored transtibial prostheses based on an automated characterization of ankle stiffness profile relying on direct loading measurements. The objectives were (A) to present a process characterizing stiffness using innovative macro, meso and micro analyses, (B) to present stiffness profiles for feet with and without anthropomorphic designs, where anthropomorphicity is defined as a similarity of the moment-angle dependency in prosthetic and in the anatomical ankle, (C) to determine sensitivity of characterization. METHODS: Three participants walked consecutively with two instrumented bone-anchored prostheses including their own prosthetic feet and Free-Flow foot meeting the anthropomorphicity criterion by design. Angle of dorsiflexion was extracted from video footage. Bending moment was recorded using multi-axis transducer attached to osseointegrated fixation. The automated characterization of stiffness involved a 12-step process relying on data-based criterion. RESULTS: The meso analyses confirmed bilinear behavior of moment-angle curves with Index of Anthropomorphicity of -2.966±2.369 Nm/Deg and 2.681±1.089 Nm/Deg indicating a convex and concave shape of usual and Free-Flow feet without and with anthropomorphic designs, respectively. CONCLUSIONS: The proposed straightforward meso analysis of the stiffness was capable to report clinical meaningful differences sensitive to feet's anthropomorphicity. Results confirmed the benefits for clinicians to rely on direct loading measurement providing individualized complementary insight into impact of components. SIGNIFICANCE: This work could assist the developments of standards and guidelines for manufacturing and safe fitting of components to growing population requiring transtibial prostheses with socket or direct skeletal attachment worldwide.

14.
Trials ; 19(1): 661, 2018 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-30486849

RESUMEN

BACKGROUND: Gait difficulties are common and frequently devastating to people with Parkinson's disease (PD). These difficulties are often followed by an increased risk of falls, leading to injury, hospitalization and mortality. The dysfunction in the basal ganglia-thalamocortical motor circuits and reduced activity in the premotor and primary motor cortices has raised interest in transcranial direct current stimulation (tDCS) as an adjunct intervention in PD. tDCS might provide a potentially safe and non-invasive treatment by modulating cortical excitability and behavioural outcomes. The aim of this study is to compare the effects of different monopolar and bipolar montages of tDCS administered to the motor cortex and cerebellum on gait speed in PD. METHODS: This study will be conducted in a randomized, double-blind cross-over design. Eighteen participants diagnosed with Parkinson's disease will receive anodal and sham tDCS (1 mA, 20 min, 10 × 4 cm2) over the premotor and primary motor cortices with the cathode over the cerebellum during treadmill walking. Three montages will be applied over three sessions and compared: anodal tDCS with a small active cathode (4 × 4 cm2); anodal tDCS with a large, functionally inert cathode (10 × 10 cm2); and sham tDCS. The primary outcome measure is gait speed, and secondary outcome measures include gait parameters (temporospatial, segmental, kinematic), the Timed Up and Go test and lower limb muscle activity patterns as measured by electromyography. DISCUSSION: This study will investigate the short-term effects of anodal tDCS over the premotor and primary motor cortices on gait abilities using monopolar and bipolar montages in people with PD. The outcomes will inform future studies aimed at inducing longer-lasting changes in neural excitability and performance using multisession tDCS designs in PD. TRIAL REGISTRATION: Australian New Zealand Clinical Trials Registry (ANZCTR), ACTRN12618000063213 . Registered on 17 January 2018. Retrospectively registered.


Asunto(s)
Marcha , Corteza Motora/fisiopatología , Enfermedad de Parkinson/terapia , Estimulación Transcraneal de Corriente Directa/métodos , Adulto , Anciano , Anciano de 80 o más Años , Estudios Cruzados , Método Doble Ciego , Electromiografía , Femenino , Análisis de la Marcha , Humanos , Masculino , Persona de Mediana Edad , Enfermedad de Parkinson/diagnóstico , Enfermedad de Parkinson/fisiopatología , Queensland , Ensayos Clínicos Controlados Aleatorios como Asunto , Recuperación de la Función , Factores de Tiempo , Estimulación Transcraneal de Corriente Directa/efectos adversos , Resultado del Tratamiento
15.
JBI Database System Rev Implement Rep ; 16(6): 1286-1310, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29894396

RESUMEN

REVIEW QUESTION: The main purpose of this scoping review is to characterize loading information applied on the residuum of individuals with transfemoral amputation fitted with an osseointegrated fixation for bone-anchored prostheses.The objectives of this scoping review are: i) to map the scope of loading variables, and ii) to report the range of magnitude of loads that has been directly measured using a portable kinetic recording apparatus fitted at the distal end of the residuum during rehabilitation exercises, standardized and unscripted activities of daily living, and adverse events.The specific review questions are.


Asunto(s)
Amputación Quirúrgica/rehabilitación , Prótesis Anclada al Hueso , Oseointegración , Soporte de Peso/fisiología , Miembros Artificiales , Ejercicio Físico/fisiología , Humanos , Diseño de Prótesis
16.
Prosthet Orthot Int ; 42(3): 318-327, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29119860

RESUMEN

BACKGROUND: In principle, lower limb bone-anchored prostheses could alleviate expenditure associated with typical socket manufacturing and residuum treatments due to socket-suspended prostheses. OBJECTIVE: This study reports (a) the incremental costs and (b) heath gain as well as (c) cost-effectiveness of bone-anchored prostheses compared to socket-suspended prostheses. STUDY DESIGN: Retrospective individual case-controlled observations and systematic review. METHODS: Actual costs were extracted from financial records and completed by typical costs when needed over 6-year time horizon for a cohort of 16 individuals. Health gains corresponding to quality-adjusted life-year were calculated using health-related quality-of-life data presented in the literature. RESULTS: The provision of bone-anchored prostheses costed 21% ± 41% more but increased quality-adjusted life-years by 17% ± 5% compared to socket-suspended prostheses. The incremental cost-effectiveness ratio ranged between -$25,700 per quality-adjusted life-year and $53,500 per quality-adjusted life-year with indicative incremental cost-effectiveness ratio of approximately $17,000 per quality-adjusted life-year. Bone-anchored prosthesis was cost-saving and cost-effective for 19% and 88% of the participants, respectively. CONCLUSION: This study indicated that bone-anchored prostheses might be an acceptable alternative to socket-suspended prostheses at least from a prosthetic care perspective in Australian context. Altogether, this initial evidence-based economic evaluation provided a working approach for decision makers responsible for policies around care of individuals with lower limb amputation worldwide. Clinical relevance For the first time, this study provided evidence-based health economic benefits of lower limb bone-anchored prostheses compared to typical socket-suspended prostheses from a prosthetic care perspective that is essential to clinicians and decision makers responsible for policies.


Asunto(s)
Amputados/rehabilitación , Miembros Artificiales/economía , Análisis Costo-Beneficio , Oseointegración/fisiología , Ajuste de Prótesis/economía , Anclas para Sutura/economía , Adulto , Anciano , Amputación Quirúrgica/métodos , Estudios de Casos y Controles , Evaluación de la Discapacidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis/economía , Ajuste de Prótesis/métodos , Queensland , Estudios Retrospectivos
17.
JBI Database System Rev Implement Rep ; 15(3): 607-619, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-28267022

RESUMEN

REVIEW QUESTION: The primary objective of this scoping review is to characterize rehabilitation programs for individuals with transfemoral amputation following the implantation of screw-type or press-fit osseointegrated fixations for bone-anchored prostheses.The secondary objective of this review is to describe partial weight bearing exercises including static and dynamic exercises as well as use of walking aids in each rehabilitation program for screw-type and press-fit fixations.The third objective of this review is to compare key rehabilitation parameters for various partial weight bearing exercises (e.g. type of training prosthesis, loading time and progression, monitoring of loading, loading direction, instructions given to patients and the use of loading regulators) within each program for screw-type and press-fit fixations (intra-variability) and between programs for screw-type and press-fit fixations (inter-variability).The specific review questions are.


Asunto(s)
Amputación Quirúrgica/rehabilitación , Oseointegración , Prótesis e Implantes/estadística & datos numéricos , Diseño de Prótesis/instrumentación , Implantación de Prótesis/instrumentación , Implantación de Prótesis/rehabilitación , Anclas para Sutura , Fémur , Humanos , Modalidades de Fisioterapia , Revisiones Sistemáticas como Asunto , Soporte de Peso
18.
IEEE Trans Neural Syst Rehabil Eng ; 25(6): 679-685, 2017 06.
Artículo en Inglés | MEDLINE | ID: mdl-28113632

RESUMEN

Quantitative assessments of prostheses performances rely more and more frequently on gait analysis focusing on prosthetic knee joint forces and moments computed by inverse dynamics. However, this method is prone to errors, as demonstrated in comparison with direct measurements of these forces and moments. The magnitude of errors reported in the literature seems to vary depending on prosthetic components. Therefore, the purposes of this study were (A) to quantify and compare the magnitude of errors in knee joint forces and moments obtained with inverse dynamics and direct measurements on ten participants with transfemoral amputation during walking and (B) to investigate if these errors can be characterised for different prosthetic knees. Knee joint forces and moments computed by inverse dynamics presented substantial errors, especially during the swing phase of gait. Indeed, the median errors in percentage of the moment magnitude were 4% and 26% in extension/flexion, 6% and 19% in adduction/abduction as well as 14% and 27% in internal/external rotation during stance and swing phase, respectively. Moreover, errors varied depending on the prosthetic limb fitted with mechanical or microprocessor-controlled knees. This study confirmed that inverse dynamics should be used cautiously while performing gait analysis of amputees. Alternatively, direct measurements of joint forces and moments could be relevant for mechanical characterising of components and alignments of prosthetic limbs.


Asunto(s)
Muñones de Amputación/fisiopatología , Amputados/rehabilitación , Miembros Artificiales , Trastornos Neurológicos de la Marcha/fisiopatología , Trastornos Neurológicos de la Marcha/rehabilitación , Marcha , Articulación de la Rodilla/fisiopatología , Adulto , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Trastornos Neurológicos de la Marcha/diagnóstico , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Ajuste de Prótesis/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estrés Mecánico , Torque , Resultado del Tratamiento
19.
Pharmacoecon Open ; 1(4): 301-314, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29441506

RESUMEN

BACKGROUND: Governmental organizations are facing challenges in adjusting procedures providing equitable assistance to consumers with amputation choosing newly available osseointegrated fixations for bone-anchored prostheses (BAPs) over socket-suspended prostheses. OBJECTIVES: The aims of this study were to (1) present a procedure focusing on tasks, documents and costs of prosthetic care, and (2) share observed obstacles and facilitators to implementation. METHODS: This research aimed at developing a governmental procedure for the provision of BAPs was designed as an action research study. A total of 18 individuals with transfemoral amputation solely funded by a Queensland State organization were considered. RESULTS: The procedure, developed between January 2011 and June 2015, included seven processes involving fixed expenses during treatment and five processes regulating ongoing prosthetic care expenses. Prosthetic care required 22 h of labor, corresponding to AUD$3300 per patient, during rehabilitation. Prosthetists spend 64 and 36% of their time focusing on prosthetic care and other activities, respectively. The procedure required adjustments related to the scope of practice of prosthetists, funding of prosthetic limbs during rehabilitation, and allocation of microprocessor-controlled prosthetic knees. Approximately 41% (7) and 59% (10) of obstacles were within (e.g. streamlining systematic processes, sustaining evaluation of this complex procedure) or outside (e.g. early and consistent consultations of stakeholders, lack of a definitive rehabilitation program) governmental control, respectively, and approximately 89% (17) of the facilitators were within governmental control (e.g. adapting existing processes). CONCLUSION: This study provides a working plan to stakeholders developing and implementing policies around the care of individuals choosing osseointegration for BAPs.

20.
Prosthet Orthot Int ; 41(4): 393-401, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27117014

RESUMEN

BACKGROUND: Load-bearing exercises are performed by transfemoral amputees fitted with an osseointegrated implant to facilitate bone remodelling. OBJECTIVE: This study presents the loading compliance comparing loads prescribed and applied on the three axes of the implant during static load-bearing exercises with a specific emphasis on axial and vectorial comparisons. STUDY DESIGN: Cohort study. METHODS: A total of 11 fully rehabilitated unilateral transfemoral amputees fitted with an osseointegrated implant performed five trials in four loading conditions using a static standing frame. The load prescribed was monitored using a vertical single-axis strain gauge connected to an electronic display. The tri-axial forces applied on the implant were measured directly with an instrumented pylon including a six-channel transducer. The analysis included 'axial' and 'vectorial' comparisons corresponding to the difference between the force applied on the long axis of the implant and the load prescribed as well as the resultant of the three components of the load applied and the load prescribed, respectively. RESULTS: The results demonstrated that axial and vectorial differences were significant in all conditions ( p < 0.05), except for the vectorial difference for the 40 kg condition ( p = 0.182). CONCLUSION: The significant lack of axial compliance led to systematic underloading of the long axis of the implant. Clinical relevance This study contributes to a better understanding of the load applied on an osseointegrated implant during the static load-bearing exercises that could contribute to improve the design of apparatus to monitor loading exercises as well as clinical guidelines for the loading progression during rehabilitation.


Asunto(s)
Amputación Quirúrgica/rehabilitación , Miembros Artificiales , Ejercicio Físico/fisiología , Oseointegración , Soporte de Peso/fisiología , Adulto , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...