Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
JACC Case Rep ; 3(6): 884-887, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34317647

RESUMEN

We report a unique case of a Starr-Edwards prosthesis (model 6310, cloth covered) implanted in the mitral position by Christian Barnard that was successfully explanted and replaced after 50 years, the longest period free from valve dysfunction ever reported. Reoperation also included replacement of the native aortic valve combined with tricuspid valve annuloplasty. (Level of Difficulty: Beginner.).

2.
Gen Thorac Cardiovasc Surg ; 69(5): 877-881, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33400196

RESUMEN

Short-term mechanical circulatory support (MCS) devices are designed to provide hemodynamic support for a wide range of clinical conditions such as high-risk cardiac surgery or interventional procedures, post-cardiotomy cardiogenic shock, acute decompensated heart failure. Electrical storm (defined as three or more sustained episodes of ventricular fibrillation-VF- in a 24-h period) is a rare but critical complication following revascularization in patients with ischemic heart disease and it is associated with a very high mortality (80-90%) both during the incident alone and during further observation. Here we report the case of a 38-year-old patient affected by coronary artery disease with moderate to severe left ventricular systolic dysfunction (EF 30-35%) who underwent emergency coronary artery bypass grafting (CABG) complicated by electrical storm and severe haemodynamic instability, successfully managed with a novel approach of biventricular mechanical circulatory support with extracorporeal life support (ECLS) in first instance, subsequently switched to Impella CP and ProtekDuo.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Oxigenación por Membrana Extracorpórea , Insuficiencia Cardíaca , Corazón Auxiliar , Adulto , Humanos , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia
3.
J Card Surg ; 35(11): 3157-3159, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32720389

RESUMEN

BACKGROUND: Displacement of Impella 5.0 secondary to patient movement or transportation is a well-known complication. Typically, repositioning of an Impella across the aortic valve is attempted over a guidewire. We present the first case, to our knowledge, of repositioning a dislodged Impella 5.0 without a guidewire under transesophageal echocardiography (TEE) guidance, by inducing rapid ventricular pacing to cross the aortic valve. CASE PRESENTATION: A 70-year-old man with low left ventricular ejection fraction underwent off-pump coronary artery bypass grafting. On 2nd postoperative day a low cardiac output state developed with increasing lactate levels and consequently the patient was taken to the cardiac catheterization laboratory for insertion of an Impella 5.0. Suddenly the Impella system failed with a rapid hemodynamic deterioration and it was successfully bedside repositioned inducing rapid ventricular pacing. CONCLUSIONS: In case of accidental Impella dislodgement and fast deterioration of the patient's hemodynamic status, rapid pacing may be an option to "open" the aortic valve thus aiding quick replacement of Impella 5.0 through the aortic valve into the left ventricle under TEE guidance.


Asunto(s)
Válvula Aórtica/cirugía , Estimulación Cardíaca Artificial/métodos , Corazón Auxiliar/efectos adversos , Falla de Prótesis , Implantación de Prótesis/métodos , Cirugía Asistida por Computador/métodos , Anciano , Puente de Arteria Coronaria Off-Pump , Ecocardiografía Transesofágica , Ventrículos Cardíacos/cirugía , Hemodinámica , Humanos , Masculino , Reoperación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA