Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Vet Clin Pathol ; 52(4): 698-704, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38097197

RESUMEN

BACKGROUND: Silica from plastic red top sample collection tubes and barium cause recognized artifacts in slide preparations for microscopic examination. OBJECTIVES: The objectives of this study were to evaluate and directly compare the microscopic appearance of silica and barium particles and various slide preparation techniques (e.g., use of coverslips, oil immersion, and different stains). A secondary objective of this study was to evaluate the effects of silica particles on cellular morphology after mechanical trauma with cytocentrifugation. METHODS: Fluid samples (deionized water, pleural effusion, peritoneal effusion, cerebrospinal fluid, and urine) were collected and evaluated in silica- and non-silica-containing tubes. Barium was added to silica and non-silica samples. Direct and cytocentrifuge preparations were compared to evaluate the effect of silica particles on cellular morphology. Preparations were stained with Wright-Giemsa, rhodizonic acid disodium salt, Alizarin Red, Grocott's methenamine silver, and Prussian blue. RESULTS: Silica and barium particles were identifiable via light microscopy with and without polarized light, although silica particles diminished with immersion oil. Barium particles retained their structure and diminished less under oil. Cytoseal mounting medium for coverslip placement resulted in diminished refractility of silica and some barium particles. Silica particles with mechanical interaction during cytocentrifugation resulted in disrupted cellular morphology with many lysed cells. Silica and barium particles were negative for all special stains tested. CONCLUSIONS: Silica from plastic red top tubes adversely affects cell morphology in cytocentrifuge preparations, potentially affecting manual differential cell counts and compromising diagnostic interpretation. Samples intended for microscopic evaluation should not be collected in silica-containing tubes.


Asunto(s)
Derrame Pleural , Dióxido de Silicio , Animales , Bario , Dióxido de Silicio/efectos adversos , Manejo de Especímenes/veterinaria , Derrame Pleural/veterinaria , Técnicas Citológicas/veterinaria
2.
Vet Clin Pathol ; 52(2): 243-251, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37127847

RESUMEN

BACKGROUND: There are few reports in dogs that have evaluated the utility of semi-quantitative scoring of bone marrow iron stores in conjunction with reticulocyte hemoglobin (CHr) to identify iron-restricted erythropoiesis due to absolute iron deficiency or iron sequestration. OBJECTIVES: An established system for scoring iron stores in human bone marrow samples was applied to dogs. The objectives were to evaluate interobserver agreement (Κω ), determine marrow iron scores in dogs without detectable hematologic abnormalities, and assess combined interpretation of iron scores and CHr to evaluate for iron-restricted erythropoiesis. METHODS: Four blinded observers independently scored iron in 139 Prussian blue-stained canine marrow samples from 0 (none) to 6 (very heavy), including healthy controls (n = 12), clinically ill dogs with (n = 100) and without (n = 16) detectable hematologic abnormalities, and dogs with experimental nutritional iron deficiency (n = 11). Additional medical record data were available for 118 dogs to evaluate for other evidence of iron deficiency (abnormal CHr, RBC indices, serum iron variables, external blood loss, or nutritional deficiencies). RESULTS: Mean Κω was 0.69 (substantial agreement) for all samples but was 0.44 (moderate agreement) for samples with iron scores <3, indicating distinguishing scores 0-2 may not be reliable. Dogs without detectable hematologic abnormalities had scores from 3-5. Dogs with scores <3 and decreased CHr often had more indicators of iron deficiency vs dogs only having low iron scores or low CHr. CONCLUSIONS: Evaluation of dogs with marrow iron score <3 for external blood loss or nutritional deficiencies is likely clinically worthwhile, particularly if there is also decreased CHr.


Asunto(s)
Anemia Ferropénica , Enfermedades de los Perros , Deficiencias de Hierro , Desnutrición , Humanos , Perros , Animales , Hierro , Eritropoyesis , Médula Ósea , Anemia Ferropénica/diagnóstico , Anemia Ferropénica/veterinaria , Hemoglobinas/análisis , Deficiencias de Hierro/veterinaria , Reticulocitos/química , Desnutrición/veterinaria
3.
Vet Clin Pathol ; 52 Suppl 2: 149-151, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36574976

Asunto(s)
Pollos , Tráquea , Animales
5.
Vet Clin Pathol ; 50(1): 132-141, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33655512

RESUMEN

BACKGROUND: Insufficient iron for erythropoiesis can occur in multiple conditions, including absolute iron deficiency, which is often caused by chronic external hemorrhage in dogs. Distinguishing this from other causes of iron-restricted erythropoiesis allows appropriate intervention. Decreased marrow iron assessed by Prussian blue staining is a method to diagnose absolute iron deficiency, but scoring systems for marrow iron are not validated in dogs. OBJECTIVES: Our objectives were to (a) evaluate the technical performance of two bone marrow iron scoring systems used in human medicine and (b) examine the effects of destaining and restaining on iron stores after Wright-stained marrow slides are destained and restained with a Prussian blue stain. METHODS: Two marrow aspirate slides were included from each of 12 ill dogs in which marrow was collected during clinical evaluation. One slide was directly stained with Prussian blue. The other was first stained with Wright stain, then destained and restained with Prussian blue. Three blinded observers scored the presence of iron in each of the 24 randomized slides using the Gale (scale 0-6) and sideroblast methods (percentage score). Slides were then re-randomized and rescored. RESULTS: For the Gale method, interobserver agreement was fair, and intraobserver agreement was substantial to perfect. There was less agreement using the sideroblast method, with a significant observer effect. Iron scores were significantly lower in destained slides compared with those stained directly. CONCLUSIONS: Interobserver and intraobserver agreements were acceptable for the Gale method, but the sideroblast method should be used cautiously. A destaining procedure before Prussian blue staining could decrease marrow iron scores.


Asunto(s)
Médula Ósea , Proyectos de Investigación , Animales , Colorantes , Perros , Hierro , Coloración y Etiquetado/veterinaria
6.
PeerJ ; 8: e10092, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33194381

RESUMEN

BACKGROUND: Glass slide preparations from a variety of specimens (blood, masses, effusions) are commonly made as part of the diagnostic work-up, however the effects of various drying methods in veterinary practice and diagnostic laboratory settings is not clear. OBJECTIVE: Compare the effects of four drying methods on results of microscopic examination of canine blood smears and direct smears of pleural or peritoneal effusion fluid. METHODS: Twelve canine blood samples (6 from healthy dogs, 6 from sick dogs) and 6 canine peritoneal or pleural effusion samples. Four smears were prepared from each of the 18 samples and dried using the following methods: air-dry, hair dryer with or without heat, and heat block at 58 °C. Observers, blinded to the drying method, independently reviewed the slides microscopically, using a scoring system to evaluate cell morphology and (for blood smears) echinocyte numbers; scoring results were analyzed statistically. RESULTS: For blood smears, several comparisons showed more adverse effects on morphology using the heat block method than for one or more other drying methods. For effusion fluid smears, RBCs dried with the heat block or air-dry methods had more poorly preserved morphology than RBCs dried by the hair dryer method without heat. CONCLUSIONS AND CLINICAL RELEVANCE: The results (1) indicate that different drying methods had a significant effect, (2) support using a hair dryer without heat for both blood smears and effusion fluid smears, and (3) discourage using a 58 °C heat block.

7.
PeerJ ; 7: e7468, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31410314

RESUMEN

BACKGROUND: Stress and diseases such as endotoxemia induce cortisol synthesis through a complex biosynthetic pathway involving intermediates (progesterone, and 17α-hydroxyprogesterone (17α-OHP)) and suppression of the hypothalamus-pituitary-thyroid axis. OBJECTIVE: To measure plasma concentrations of cortisol, progesterone, 17α-OHP, and thyroid stimulating hormone (TSH) in dogs experimentally injected with intravenous low-dose lipopolysaccharide (LPS). Our hypothesis was that LPS treatment would elicit a significant increase in cortisol and its precursors, and a significant decrease in TSH concentration. METHODS: Hormone measurements were performed on blood samples left over from a previous investigation (2011) on the effect of low-dose LPS on hematological measurands. Five sexually intact female dogs, none in estrous at the time of the study, were administered saline treatment two weeks prior to LPS treatment. LPS was administered intravenously at a dose of 0.1 µg/kg. Blood was collected before (baseline, time -24 hours) and 3-, 6- and 24-hours post-injection. Mixed model analysis for repeated measures was used, with both treatment and time as the repeated factors. Ranked transformation were applied when diagnostic analysis exhibited violation of normality and equal variance assumptions. Post hoc multiple comparisons were performed with Tukey's adjustment. Statistical significance was defined as p < 0.05. RESULTS: Significant differences relative to baseline values were detected following both treatments. Compared to baseline, dogs had significantly higher cortisol and 17α-OHP at 3-hours, and significantly lower TSH at 3- and 6-hours following LPS treatment. Dogs had significantly lower TSH at 6- and 24- following saline treatment. Though not statistically significant, the trend in progesterone concentrations was similar to cortisol and 17α-OHP, with an increase at 3-hours post-injection followed by a decrease close to baseline following both LPS and saline. Cortisol and 17α-OHP concentrations were higher after LPS treatment than after saline treatment at 3- and 6-hours post-injection, but differences were not statistically significant, and no significant differences between treatments were detected for any other hormone or timepoint. DISCUSSION AND CONCLUSION: Cortisol and its adrenal precursors are released in the bloodstream following a low dose of LPS, while TSH appears to decrease. Similar changes occurred following saline treatment, suggesting that even routine handling and saline injection in conditioned dogs can elicit alterations in the internal equilibrium with subsequent modification of both hypothalamus-pituitary-adrenal and thyroid axes. Changes to adrenal and thyroid hormone concentrations must be interpreted in light of clinical information. Further studies are needed to elucidate mechanisms of adrenal steroidal hormone synthesis and secretion in response to various stressful stimuli in both neutered and intact animals.

8.
Vet Clin Pathol ; 44(2): 249-52, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25707928

RESUMEN

A 9.5-year-old, male castrated Walker Hound was presented for evaluation of progressive weakness, anorexia, and weight loss. Imaging revealed multiple abdominal and thoracic masses and ascites; fine-needle aspirates of mesenteric and splenic masses confirmed malignancy, most likely histiocytic sarcoma. Laboratory analyses revealed increased ionized calcium and parathyroid hormone-related peptide (PTH-rP) concentrations, and concurrent low-normal parathyroid hormone concentration, consistent with humoral hypercalcemia of malignancy. Necropsy was performed after euthanasia. The dog had disseminated histiocytic sarcoma, including sarcomatosis, as well as bilateral thyroid carcinoma. PTH-rP immunostaining was positive in the thyroid carcinoma but negative in the histiocytic neoplasm. These results suggest that thyroid carcinoma-associated hypercalcemia can be caused by tumor secretion of PTH-rP.


Asunto(s)
Carcinoma/veterinaria , Enfermedades de los Perros/metabolismo , Sarcoma Histiocítico/veterinaria , Hipercalcemia/metabolismo , Proteína Relacionada con la Hormona Paratiroidea/metabolismo , Neoplasias de la Tiroides/veterinaria , Animales , Recuento de Células Sanguíneas/veterinaria , Carcinoma/metabolismo , Carcinoma/patología , Enfermedades de los Perros/patología , Perros , Regulación Neoplásica de la Expresión Génica , Sarcoma Histiocítico/metabolismo , Sarcoma Histiocítico/patología , Hipercalcemia/genética , Masculino , Proteína Relacionada con la Hormona Paratiroidea/genética , Neoplasias de la Tiroides/metabolismo , Neoplasias de la Tiroides/patología
9.
Can Vet J ; 55(12): 1173-9, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25477546

RESUMEN

This study sought to develop customized morphology flagging thresholds for canine erythrocyte volume and hemoglobin concentration [Hgb] on the ADVIA 120 hematology analyzer; compare automated morphology flagging with results of microscopic blood smear evaluation; and examine effects of customized thresholds on morphology flagging results. Customized thresholds were determined using data from 52 clinically healthy dogs. Blood smear evaluation and automated morphology flagging results were correlated with mean cell volume (MCV) and cellular hemoglobin concentration mean (CHCM) in 26 dogs. Customized thresholds were applied retroactively to complete blood (cell) count (CBC) data from 5 groups of dogs, including a reference sample group, clinical cases, and animals with experimentally induced iron deficiency anemia. Automated morphology flagging correlated more highly with MCV or CHCM than did blood smear evaluation; correlation with MCV was highest using customized thresholds. Customized morphology flagging thresholds resulted in more sensitive detection of microcytosis, macrocytosis, and hypochromasia than default thresholds.


Adaptation des seuils d'Advia 120 pour le volume d'érythrocytes et la concentration d'hémoglobines des chiens et les effets sur le signalement des résultats de la morphologie. Cette étude a cherché à développer des seuils de signalement adaptés à la morphologie pour le volume des érythrocytes et la concentration d'hémoglobines [Hgb] des chiens sur l'analyseur d'hématologie ADVIA 120; à comparer le signalement automatique de la morphologie avec les résultats de l'évaluation microscopique des frottis sanguins; et à examiner les effets des seuils adaptés sur les résultats de signalement de la morphologie. Des seuils adaptés ont été déterminés à l'aide de données de 52 chiens cliniquement en santé. L'évaluation des frottis sanguins et les résultats de signalement automatiques de la morphologie ont été corrélés avec le volume cellulaire moyen (VCM) et la concentration d'hémoglobines cellulaires moyennes (CHCM) chez 26 chiens. Les seuils adaptés ont été appliqués rétroactivement à des données d'hémogramme provenant de 5 groupes de chiens, y compris un groupe de référence, de cas cliniques et d'animaux avec une anémie ferriprive induite expérimentalement. Il y avait une corrélation supérieure du signalement automatique de la morphologie avec le VCM ou le CHCM par rapport à l'évaluation des frottis sanguins; la corrélation avec le VCM était supérieure en utilisant des seuils adaptés. Des seuils de signalement adaptés à la morphologie ont produit une détection plus sensible de la microcytose, de la macrocytose et de l'hypochromasie que les seuils par défaut.(Traduit par Isabelle Vallières).


Asunto(s)
Perros/sangre , Volumen de Eritrocitos/veterinaria , Citometría de Flujo/veterinaria , Hemoglobinas/análisis , Anemia Ferropénica/sangre , Anemia Ferropénica/diagnóstico , Anemia Ferropénica/veterinaria , Animales , Enfermedades de los Perros/sangre , Enfermedades de los Perros/diagnóstico , Femenino , Citometría de Flujo/métodos , Citometría de Flujo/normas , Hematócrito/veterinaria , Masculino , Estándares de Referencia
10.
Vet Clin Pathol ; 43(2): 206-17, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24588622

RESUMEN

BACKGROUND: The Heska Dri-Chem 4000 uses dry slide technology to evaluate serum or plasma. No previous independent performance evaluation is published to the authors' knowledge. OBJECTIVES: The objectives were to (1) characterize analytical performance of a Dri-Chem 4000 by measuring precision and bias, (2) compare analytical performance of that Dri-Chem 4000 unit with a predetermined quality requirement, and (3) determine whether statistical QC of the Dri-Chem 4000 is possible using the 13s control rule. METHODS: Sixteen analytes were measured using plasma from dogs, cats, and horses. Coefficient of variation (CV), bias, and observed total error (TEobs ) were calculated. TEobs was compared with allowable total error (TEa ). Sigma metric and quality goal index were calculated where relevant. QC validation was performed. RESULTS: Bias and TEobs calculated using quality control material (QCM) data were smaller than those calculated using method comparison data. Using TEobs calculated from species-specific CV and QCM-based bias, 100% of analytes in each species met ASVCP-recommended TEa . Desired error detection and false rejection rates were achievable using the 13s control rule and ASVCP-recommended TEa values for 9/16 (56%) of analytes in dogs, 9/14 (64%) of analytes in cats, and 8/13 (62%) of analytes in horses. CONCLUSIONS: Analytical performance of the Dri-Chem 4000 is comparable to that reported by other authors for other small benchtop biochemistry analyzers. Statistical QC using a simple control rule is possible for most analytes in dogs, cats, and horses.


Asunto(s)
Análisis Químico de la Sangre/veterinaria , Errores Diagnósticos/veterinaria , Animales , Análisis Químico de la Sangre/instrumentación , Análisis Químico de la Sangre/normas , Gatos , Perros , Caballos , Sistemas de Atención de Punto/normas , Control de Calidad , Reproducibilidad de los Resultados , Especificidad de la Especie
12.
Environ Sci Technol ; 48(1): 93-103, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24350796

RESUMEN

The oil spill resulting from the explosion of the Deepwater Horizon drilling platform initiated immediate concern for marine wildlife, including common bottlenose dolphins in sensitive coastal habitats. To evaluate potential sublethal effects on dolphins, health assessments were conducted in Barataria Bay, Louisiana, an area that received heavy and prolonged oiling, and in a reference site, Sarasota Bay, Florida, where oil was not observed. Dolphins were temporarily captured, received a veterinary examination, and were then released. Dolphins sampled in Barataria Bay showed evidence of hypoadrenocorticism, consistent with adrenal toxicity as previously reported for laboratory mammals exposed to oil. Barataria Bay dolphins were 5 times more likely to have moderate-severe lung disease, generally characterized by significant alveolar interstitial syndrome, lung masses, and pulmonary consolidation. Of 29 dolphins evaluated from Barataria Bay, 48% were given a guarded or worse prognosis, and 17% were considered poor or grave, indicating that they were not expected to survive. Disease conditions in Barataria Bay dolphins were significantly greater in prevalence and severity than those in Sarasota Bay dolphins, as well as those previously reported in other wild dolphin populations. Many disease conditions observed in Barataria Bay dolphins are uncommon but consistent with petroleum hydrocarbon exposure and toxicity.


Asunto(s)
Insuficiencia Suprarrenal/veterinaria , Delfín Mular , Enfermedades Pulmonares/veterinaria , Contaminación por Petróleo , Insuficiencia Suprarrenal/epidemiología , Animales , Bahías , Florida/epidemiología , Louisiana/epidemiología , Enfermedades Pulmonares/epidemiología , Masculino
13.
J Avian Med Surg ; 27(4): 264-8, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24640927

RESUMEN

To evaluate the relationship between osmolality and specific gravity of urine samples from clinically normal adult parrots and to determine a formula to convert urine specific gravity (USG) measured on a reference scale to a more accurate USG value for an avian species, urine samples were collected opportunistically from a colony of Hispaniolan Amazon parrots (Amazona ventralis). Samples were analyzed by using a veterinary refractometer, and specific gravity was measured on both canine and feline scales. Osmolality was measured by vapor pressure osmometry. Specific gravity and osmolality measurements were highly correlated (r = 0.96). The linear relationship between refractivity measurements on a reference scale and osmolality was determined. An equation was calculated to allow specific gravity results from a medical refractometer to be converted to specific gravity values of Hispaniolan Amazon parrots: USGHAp = 0.201 +0.798(USGref). Use of the reference-canine scale to approximate the osmolality of parrot urine leads to an overestimation of the true osmolality of the sample. In addition, this error increases as the concentration of urine increases. Compared with the human-canine scale, the feline scale provides a closer approximation to urine osmolality of Hispaniolan Amazon parrots but still results in overestimation of osmolality.


Asunto(s)
Amazona/orina , Refractometría/veterinaria , Urinálisis/veterinaria , Amazona/fisiología , Animales , Concentración Osmolar , Gravedad Específica
14.
Vet Clin North Am Small Anim Pract ; 42(1): 85-96, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22285159

RESUMEN

The relatively recent discovery of hepcidin has stimulated renewed research interest in iron metabolism and iron-related disorders, emphasizing the importance of this hormone in many normal and pathologic processes. Important questions still remain to be answered; however, research to date offers promising diagnostic and therapeutic implications for both humans and veterinary species.


Asunto(s)
Péptidos Catiónicos Antimicrobianos/fisiología , Homeostasis/fisiología , Trastornos del Metabolismo del Hierro/veterinaria , Hierro/metabolismo , Animales , Animales Domésticos , Péptidos Catiónicos Antimicrobianos/deficiencia , Hepcidinas , Trastornos del Metabolismo del Hierro/diagnóstico , Trastornos del Metabolismo del Hierro/metabolismo
15.
Vet Med Int ; 2011: 751849, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21785687

RESUMEN

Objectives of this study were to adapt a commercial human protein C (PC) colorimetric assay for use in dogs and to investigate effects of various storage conditions. The human assay was modified by using pooled canine plasma for calibration and by increasing the activation time. PC activity was measured in fresh canine plasma and in plasma stored under various conditions. PC activity of some stored samples was significantly different from that of fresh plasma; however, differences were small. No difference was detected in samples stored under similar conditions but analyzed in different laboratories using similar methodology. Results of this study indicate that the human colorimetric assay is suitable for canine samples if pooled canine plasma is used for calibration, that Clinical and Laboratory Standards Institute sample storage guidelines developed for testing in humans are appropriate for dogs, and that comparisons of results from laboratories using similar methodology are legitimate.

16.
Vet Clin Pathol ; 40(2): 207-14, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21554370

RESUMEN

An 8-year-old female spayed Pug dog was presented for evaluation of cutaneous lesions occurring secondary to immunosuppressive treatment of presumed immune-mediated thrombocytopenia. Abnormal hematologic findings included persistent thrombocytopenia, macrothrombocytes, and variably shaped, often fusiform, blue cytoplasmic inclusions in neutrophils. May-Hegglin anomaly (MHA) was suspected based on the morphologic appearance of platelets and neutrophils. Examination of cells by transmission electron microscopy revealed normal platelet ultrastructure; neutrophil inclusions had features similar to those reported for inclusions in human MHA. Neutrophil function was within normal limits based on flow cytometric analysis. Thrombelastography indicated a prolonged clotting time (r), and PlateletMapping showed a lack of response to 2 µM ADP compared with a moderate response in the control dog. Immunocytochemical staining of blood smears using 2 commercially available antibodies against MYH9 protein (nonmuscle myosin heavy chain II) yielded negative results. However, genomic DNA sequencing analysis of the dog's MYH9 gene identified a single point mutation, resulting in substitution of lysine for glutamine at the 1841 amino acid position; this mutation is identical to one identified in people with MHA. To our knowledge, this is the first report of an MYH9 mutation in the dog. MHA-associated macrothrombocytopenia may be mistaken for immune-mediated thrombocytopenia.


Asunto(s)
Enfermedades de los Perros/sangre , Trombocitopenia/veterinaria , Animales , Plaquetas/ultraestructura , Enfermedades de los Perros/genética , Perros , Femenino , Pérdida Auditiva Sensorineural , Microscopía Electrónica de Transmisión/veterinaria , Cadenas Pesadas de Miosina/genética , Mutación Puntual/genética , Tromboelastografía/veterinaria , Trombocitopenia/sangre , Trombocitopenia/genética
17.
Vet Clin Pathol ; 39(4): 474-9, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21198734

RESUMEN

BACKGROUND: Advantages of handheld and small bench-top biochemical analyzers include requirements for smaller sample volume and practicality for use in the field or in practices, but little has been published on the performance of these instruments compared with standard reference methods in analysis of reptilian blood. OBJECTIVE: The aim of this study was to compare reptilian blood biochemical values obtained using the Abaxis VetScan Classic bench-top analyzer and a Heska i-STAT handheld analyzer with values obtained using a Roche Hitachi 911 chemical analyzer. METHODS: Reptiles, including 14 bearded dragons (Pogona vitticeps), 4 blue-tongued skinks (Tiliqua gigas), 8 Burmese star tortoises (Geochelone platynota), 10 Indian star tortoises (Geochelone elegans), 5 red-tailed boas (Boa constrictor), and 5 Northern pine snakes (Pituophis melanoleucus melanoleucus), were manually restrained, and a single blood sample was obtained and divided for analysis. Results for concentrations of albumin, bile acids, calcium, glucose, phosphates, potassium, sodium, total protein, and uric acid and activities of aspartate aminotransferase and creatine kinase obtained from the VetScan Classic and Hitachi 911 were compared. Results for concentrations of chloride, glucose, potassium, and sodium obtained from the i-STAT and Hitachi 911 were compared. RESULTS: Compared with results from the Hitachi 911, those from the VetScan Classic and i-STAT had variable correlations, and constant or proportional bias was found for many analytes. Bile acid data could not be evaluated because results for 44 of 45 samples fell below the lower linearity limit of the VetScan Classic. CONCLUSIONS: Although the 2 portable instruments might provide measurements with clinical utility, there were significant differences compared with the reference analyzer, and development of analyzer-specific reference intervals is recommended.


Asunto(s)
Técnicas de Laboratorio Clínico/veterinaria , Reptiles/sangre , Animales , Glucemia/análisis , Proteínas Sanguíneas/análisis , Boidae/sangre , Técnicas de Laboratorio Clínico/instrumentación , Técnicas de Laboratorio Clínico/normas , Electrólitos/sangre , Lagartos/sangre , Sistemas de Atención de Punto , Valores de Referencia , Serpientes/sangre , Tortugas/sangre
18.
J Am Vet Med Assoc ; 235(11): 1309-13, 2009 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-19951099

RESUMEN

OBJECTIVE: To compare blood glucose concentrations measured with 2 portable blood glucose meters (PBGMs) validated for use in dogs (PBGM-D) and humans (PBGM-H) and an automated chemistry analyzer. DESIGN: Validation study. SAMPLE POPULATION: 92 samples of fresh whole blood and plasma from 83 dogs with various diseases. PROCEDURES: Each PBGM was used to measure whole blood glucose concentration, and the automated analyzer was used to measure plasma glucose concentration. Passing-Bablok linear regression and Bland-Altman plots were used to determine correlations and bias between the PBGMs and the automated analyzer. Calculated acceptability limits based on combined inherent instrument imprecision were used with Bland-Altman plots to determine agreement. Clinical relevance was assessed via error grid analysis. RESULTS: Although correlation between results of both PBGMs and the standard analyzer was > 0.90, disagreement was greater than could be explained by instrument imprecision alone. Mean difference between PBGM-H and chemistry-analyzer values was -15.8 mg/dL. Mean difference between PBGM-D and chemistry-analyzer values was 2.4 mg/dL. Linear regression analysis revealed proportional bias of PBGM-H (greater disagreement at higher glucose concentrations); no proportional bias was detected for PBGM-D. No constant bias was detected for either PBGM. Error grid analysis revealed all measurements from both PBGMs were within zones without an anticipated effect on clinical outcome. CONCLUSIONS AND CLINICAL RELEVANCE: Neither PBGM had exact agreement with the automated analyzer; however, the disagreement detected did not have serious clinical consequences. Our findings stressed the importance of using the same device for monitoring trends in dogs and using instrument-specific reference ranges.


Asunto(s)
Análisis Químico de la Sangre/veterinaria , Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Enfermedades de los Perros/sangre , Animales , Automatización , Análisis Químico de la Sangre/instrumentación , Perros , Humanos , Estudios Retrospectivos
19.
Vet Clin Pathol ; 38(2): 242-6, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19351344

RESUMEN

BACKGROUND: Ultrasound-guided fine needle aspiration of the spleen is commonly used in the diagnostic evaluation of veterinary patients. Techniques using suction delivered through a 6-20-cm(3) syringe are the most commonly described means of obtaining cytologic samples of the spleen. Comparison studies of various human lesions have shown nonaspiration techniques to produce equal or superior cytologic specimens with less blood than specimens obtained using aspiration techniques. OBJECTIVE: The purpose of this study was to compare the quality of splenic cytology specimens obtained using aspiration and nonaspiration techniques. METHODS: Client-owned dogs (n=24) and cats (n=7) receiving an abdominal ultrasound at the University of Tennessee College of Veterinary Medicine were enrolled in the study between January and June 2005. Samples were obtained from patients with and without sonographic splenic abnormalities. Two clinical pathologists, working independently and blinded to the method of sample collection, graded the cytologic specimens using a subjective scoring system for cellularity, amount of blood, and preservation of cellular morphology. RESULTS: Agreement between the 2 independent observers was good. Direct comparison of the 2 techniques showed that samples obtained by the nonaspiration method had higher cellularity (P=.0002), less blood (P=.0023), and similar cell morphology (P=1.0000) compared with samples obtained by the aspiration method. CONCLUSION: These results suggest the nonaspiration technique is a superior method for obtaining a high-quality cytologic specimen from the canine and feline spleen.


Asunto(s)
Biopsia con Aguja/veterinaria , Bazo/citología , Animales , Biopsia con Aguja/métodos , Enfermedades de los Gatos/diagnóstico , Enfermedades de los Gatos/patología , Gatos , Enfermedades de los Perros/diagnóstico , Enfermedades de los Perros/patología , Perros
20.
Vet Clin Pathol ; 38(1): 13-9, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19228364

RESUMEN

BACKGROUND AND OBJECTIVE: We investigated hepatic gene expression in dogs with experimentally induced nutritional iron deficiency (ID). Our hypothesis was that ID would result in decreased hepcidin gene expression, and possibly in altered expression of other genes associated with iron metabolism. METHODS: Liver biopsies were collected from each of 3 dogs before induction of ID, at the point of maximal ID, and after resolution of ID. Using Affymetrix microarray technology and analytical tools specifically designed for microarray data, we identified genes that had at least a 2-fold change in expression in response to ID. Four genes were selected for further analysis by reverse transcriptase PCR (RT-PCR). RESULTS: Dogs with ID had markedly decreased expression of the hepcidin gene (mean decrease of 40-fold for one probe and >100-fold for another probe) and increased expression of the transferrin receptor gene (mean increase of >7-fold). There was also mildly decreased expression of the "similar to calreticulin" gene and a gene of unknown function. Results of RT-PCR analysis were consistent with microarray findings. CONCLUSION: Changes in hepcidin and transferrin receptor gene expression were consistent with the known biology of iron metabolism. The decrease in expression of a gene identified as "similar to calreticulin," while not statistically significant, was consistent with the findings of other investigators that suggest iron plays a role in calreticulin expression.


Asunto(s)
Anemia Ferropénica/veterinaria , Enfermedades de los Perros/metabolismo , Regulación de la Expresión Génica/fisiología , Hígado/metabolismo , Anemia Ferropénica/metabolismo , Fenómenos Fisiológicos Nutricionales de los Animales , Animales , Perros , Femenino , Hierro de la Dieta , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA