Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
World J Clin Cases ; 7(23): 3945-3956, 2019 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-31832396

RESUMEN

BACKGROUND: Diabetic kidney disease (DKD) is a common complication of diabetes. The patient's prognosis is poor once DKD progresses to advanced stage. Accurate diagnosis and timely treatment of early DKD are important for improving patient's prognosis and reducing mortality. AIM: To explore the value of elastography point quantification (ElastPQ) in improving the accuracy of early DKD diagnosis. METHODS: A total of 69 patients with type 2 diabetes were recruited from Naval Military Medical University Affiliated Gongli Hospital. Patients were divided into early DKD group and medium DKD group according to pathological results and urinary albumin excretion rate (UAER). Another 40 patients with simple diabetes were included as the diabetes group. The baseline data, laboratory diagnostic indicators, and ultrasound indicators for each patient were recorded. The differences of the indicators in the three groups were compared. Multivariate logistic regression was used to analyze the influencing factors of the development from simple diabetes into early DKD and from early DKD into medium DKD. Receiver operating characteristic analyses of potential indicators in identifying early DKD and medium DKD, and early DKD and simple diabetes were established. RESULTS: Multivariate logistic regression analysis showed that UAER (P < 0.001), renocortical Young's Modulus (YM) (P < 0.001), and renal parenchymal thickness (P = 0.013) were the independent influencing factors of the development from early DKD into medium DKD. Diabetes duration (P = 0.041), UAER (P = 0.034), and renocortical YM (P = 0.017) were the independent influencing factors of the development from simple diabetes into early DKD. Receiver operating characteristic analysis indicated that UAER, renocortical YM, and renal parenchymal thickness were accurate in identifying early DKD and medium DKD [all area under curve (AUC) > 0.9]. The accuracy of UAER (AUC = 0.744), diabetes duration (AUC = 0.757), and renocortical YM (AUC = 0.782) for the diagnosis of early DKD and simple diabetes were limited. However, the combined diagnosis of UAER, diabetes duration, and renocortical YM was accurate in identifying early DKD and simple diabetes (AUC = 0.906), which was significantly higher than any of the three indicators (all P < 0.05). CONCLUSION: ElastPQ is of great value in the diagnosis of early DKD. When combined with the diabetes duration and UAER, it is expected to diagnose accurately early DKD.

2.
Biol Proced Online ; 15(1): 1, 2013 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-23294600

RESUMEN

BACKGROUND: To explore a new method of kidney biopsy with coaxial trocar and bard biopsy gun under low dose computed tomography (CT)-guidance and evaluate its accuracy, safety, and efficacy. METHODS: Sixty patients underwent renal biopsy under CT-guidance. They were randomly divided into two groups: group I, low dose CT-guided (120 kV and 25 or 50 mAs) and group II, standard dose CT-guided (120 kV and 250 mAs). For group I, the coaxial trocar was accurately placed adjacent to the renal capsule of the lower pole, the needle core was removed, and samples were obtained with a bard biopsy gun. For group II, the coaxial trocar was not used. Total number of passes, mean biopsy diameter, mean glomeruli per specimen, mean operation time, mean scanning time, and mean radiation dose were noted. Dose-length product (DLP) was used to calculate the radiation doses. After 24 hours of the biopsy, ultrasound was repeated to identify any subcapsular hematoma. RESULTS: Success rate of biopsy in group I was 100% while using low dose CT-guidance along with coaxial trocar renal. There was no statistic differences bewteen group I and II in the total number of passes, mean biopsy diameter, mean glomeruli per specimen and mean time of operation and CT scanning. The average DLP of group I was lower as compared to the value of group II (p <0.05). CONCLUSIONS: Kidney biopsy using coaxial trocar and bard biopsy gun under low dose CT was an accurate, simple and safe method for diagnosis and treatment of kidney diseases. It can be used for repeat and multiple biopsies, particularly suitable for obese and renal atrophy patients in whom the kidneys are difficult to image.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA