1.
Artículo en Inglés | MEDLINE | ID: mdl-29856714

RESUMEN

Advanced satellite-based frequency transfers by two-way carrier-phase (TWCP) and integer precise point positioning have been performed between the National Institute of Information and Communications Technology and Korea Research Institute of Standards and Science. We confirm that the disagreement between them is less than at an averaging time of several days. In addition, an overseas frequency ratio measurement of Sr and Yb optical lattice clocks was directly performed by TWCP. We achieved an uncertainty at the mid-10-16 level after a total measurement time of 12 h. The frequency ratio was consistent with the recently reported values within the uncertainty.

2.
Artículo en Inglés | MEDLINE | ID: mdl-27913335

RESUMEN

We developed a system for the remote frequency comparison of optical clocks. The system does not require a flywheel oscillator at the remote end, making it possible to evaluate optical frequencies even in laboratories, where no stable microwave reference, such as an Rb clock, a Cs clock, or a hydrogen maser exists. The system is established by the integration of several systems: a portable carrier-phase two-way satellite frequency transfer station and a microwave signal generation system by an optical frequency comb from an optical clock. The measurement was as quick as a conventional method that employs a local microwave reference. We confirmed the system uncertainty and instability to be at the low 10-15 level using an Sr lattice clock.

3.
Artículo en Inglés | MEDLINE | ID: mdl-23221211

RESUMEN

We performed measurements of carrier-phase-based two-way satellite time and frequency transfer (TWST-FT) with an A/D sampler and conventional TWSTFT system. We found that an instability resulting from a local signal at the satellite transponder was negligible. The short-term stability of 4 × 10(-13) at 1 s was achieved in a short-baseline measurement. The results showed good agreement with the GPS carrier phase.

4.
Artículo en Inglés | MEDLINE | ID: mdl-22481788

RESUMEN

Two-way satellite time and frequency transfer (TWSTFT) is one of the main techniques used to compare atomic time scales over long distances. To both improve the precision of TWSTFT and decrease the satellite link fee, a new software-defined modem with dual pseudo-random noise (DPN) codes has been developed. In this paper, we demonstrate the first international DPN-based TWSTFT experiment over a period of 6 months. The results of DPN exhibit excellent performance, which is competitive with the Global Positioning System (GPS) precise point positioning (PPP) technique in the short-term and consistent with the conventional TWSTFT in the long-term. Time deviations of less than 75 ps are achieved for averaging times from 1 s to 1 d. Moreover, the DPN data has less diurnal variation than that of the conventional TWSTFT. Because the DPN-based system has advantages of higher precision and lower bandwidth cost, it is one of the most promising methods to improve international time-transfer links.

5.
Opt Express ; 19(17): 16498-507, 2011 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-21935014

RESUMEN

We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of 2 × 10(-15) at 1 second and 4 × 10(-18) at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below 2 × 10(-15) at 1 second and 7 × 10(-17) at 1000 seconds. The system was available for the direct comparison of two distant (87)Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.

6.
Artículo en Inglés | MEDLINE | ID: mdl-20040442

RESUMEN

We have demonstrated a microwave transfer over a 204-km noisy urban fiber link by a cascaded system with 2 stages, which connected 10-GHz and 1-GHz transfer systems in series. A diurnal phase-noise cancellation ratio of 45 dB was obtained by use of an electronic phase-noise compensation system. Additionally, the stabilities reached 6 x 10(-14) at 1 s and 5 x 10(-17) at one-half day, which agreed with the root-sum-square of those of the 10-GHz and 1-GHz transfers. We verified for the first time that the transfer stability degrades only square root N times in a cascaded system with N stages.


Asunto(s)
Fibras Ópticas , Telecomunicaciones/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Microondas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
7.
Opt Lett ; 34(19): 2949-51, 2009 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-19794778

RESUMEN

An rf dissemination system using an optical fiber link has been developed. The phase noise induced during optical fiber transmission has been successfully cancelled using what we believe to be a novel fiber-noise compensation system with a combination of electrical and optical compensations. We have performed rf transfer in a 114 km urban telecom fiber link in Tokyo with a transfer stability of 10(-18) level at an averaging time of 1 day. Additionally, a high degree of continuous operation robustness has been confirmed.

8.
J Agric Food Chem ; 56(16): 7305-10, 2008 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-18672883

RESUMEN

Three new phenolic compounds named whiskey tannins A and B and carboxyl ellagic acid were isolated from commercial Japanese whiskey, along with gallic acid, ellagic acid, brevifolin carboxylic acid, three galloyl glucoses, a galloyl ester of phenolic glucoside, 2,3-(S)-hexahydroxydiphenoylglucose, and castacrenin B. Whiskey tannins A and B were oxidation products of a major oak wood ellagitannin, castalagin, in which the pyrogallol ring at the glucose C-1 position of castalagin was oxidized to a cyclopentenone moiety. These tannins originated from ellagitannins contained in the oak wood used for barrel production; however, the original oak wood ellagitannins were not detected in the whiskey. To examine whether the whiskey tannins were produced during the charring process of barrel production, pyrolysis products of castalagin were investigated. Dehydrocastalagin and a new phenolcarboxylic acid trislactone having an isocoumarin structure were isolated, along with castacrenin F and ellagic acid. However, whiskey tannins were not detected in the products.


Asunto(s)
Bebidas Alcohólicas/análisis , Flavonoides/química , Flavonoides/aislamiento & purificación , Taninos Hidrolizables/química , Fenoles/química , Fenoles/aislamiento & purificación , Quercus/química , Madera/química , Ácido Elágico/química , Ácido Elágico/aislamiento & purificación , Flavonoides/análisis , Oxidación-Reducción , Fenoles/análisis , Polifenoles , Taninos/química , Taninos/aislamiento & purificación
9.
Chem Pharm Bull (Tokyo) ; 56(3): 266-72, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18310934

RESUMEN

Lipase and amylase inhibitory activities of black tea were examined. After solvent partitioning of a black tea extract with the ethyl acetate and n-butanol, the two soluble fractions showed comparable inhibitory activities. Activity in the ethyl acetate fraction was mainly attributable to polyphenols with low-molecular weights, such as theaflavin gallates. On the other hand, the active substance in the n-butanol layer was ascertained to be a polymer-like substance. 1H- and 13C-NMR spectra showed signals arising from the flavan A-ring and galloyl groups, although signals due to flavan B-rings were not detected, suggesting that the polymer-like substances were generated by oxidative condensation of flavan B-rings, a result which was previously deduced from our results of in vitro catechin oxidation experiments. Enzymatic oxidation of epicatechin 3-O-gallate produced a similar polymer-like substance and suggested that condensation between a B-ring and galloyl groups was involved in the polymerization reaction.


Asunto(s)
Amilasas/antagonistas & inhibidores , Inhibidores Enzimáticos/farmacología , Flavonoides/farmacología , Lipasa/antagonistas & inhibidores , Fenoles/farmacología , Té/química , Cromatografía Líquida de Alta Presión , Inhibidores Enzimáticos/química , Inhibidores Enzimáticos/aislamiento & purificación , Etanol/química , Flavonoides/química , Flavonoides/aislamiento & purificación , Espectroscopía de Resonancia Magnética , Espectrometría de Masas , Oxidación-Reducción , Fenoles/química , Fenoles/aislamiento & purificación , Polifenoles , Espectrofotometría Ultravioleta
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA