Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 289
Filtrar
1.
J Cardiothorac Surg ; 19(1): 211, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38616249

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has become widely used in recent years, However, there is also an increasing need for removal of TAVR valves due to prosthetic valve dysfunction (PVD) and the development of infective endocarditis. Surgical aortic valve replacement (AVR) for these patients is risky due to the original patient background and anatomic conditions. Intuity rapid deployment aortic valve (Edwards Lifesciences, Irvine, CA) replacement would be useful for such high risk patients to prevent longer cardiac arrest time and obtain good hemodynamic results. However, there are few reports which present Intuity valve replacement after TAVR explantation. Herein, We report two cases in which we have achieved good hemodynamics with shorter cardiac arrest times by using a rapid deployment valve after TAVR explantation. CASE PRESENTATION: We present 2 cases of successful implantation of the Intuity rapid deployment valve after TAVR explantation. The 84- and 88-year-old female patients had previously received TAVR for severe aortic stenosis with SAPIEN XT (Edwards Lifesciences, Irvine, CA) and developed PVD during follow-up. The TAVR valve was removed carefully, then an Intuity valve was implanted with cardiac arrest times of 69 and 41 min. Both patients had good echocardiographic results with effective orifice area of 2.0 cm2 and 1.2 cm2 and mean trans-aortic plessure gradient of 9 mmHg and 15 mmHg respectively without aortic regurgitation. They were discharged without major complications. CONCLUSIONS: Surgical AVR using a rapid deployment valve is a useful alternative to sutured AVR after TAVR valve explantation. It allows for shorter cardiac arrest times and better postoperative hemodynamics without major complication.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Paro Cardíaco , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Remoción de Dispositivos
3.
Eur J Obstet Gynecol Reprod Biol ; 296: 194-199, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38458035

RESUMEN

OBJECTIVE: Assisted reproductive technology (ART), especially frozen-thawed embryo transfer (FET) in a hormone replacement cycle (HRC), is a risk factor for placenta accreta spectrum (PAS). This study aimed to clarify the risk factors for PAS related to the maternal background and ART techniques in pregnancies achieved after FET in an HRC. STUDY DESIGN: We performed a case-control study in two tertiary perinatal centres in Japan. Among 14,028 patients who delivered at ≥24 weeks of gestation or were transferred after delivery to two tertiary perinatal centres between 2010 and 2021, 972 conceived with ART and 13,056 conceived without ART. PAS was diagnosed on the basis of the FIGO classification for the clinical diagnosis of PAS or retained products of conception after delivery at ≥24 weeks of gestation. We excluded women with fresh embryo transfer, FET with a spontaneous ovulatory cycle, a donor oocyte cycle, and missing details of the ART treatment. Finally, among women who conceived after FET in an HRC, 62 with PAS and 340 without PAS were included in this study. Multivariate logistic regression models were used for case-control comparisons, with adjustment for maternal age at delivery, parity, endometriosis or adenomyosis, the number of previous uterine surgeries of caesarean section, myomectomy, endometrial polypectomy or endometrial curettage, placenta previa, the stage of transferred embryos, and endometrial thickness at the initiation of progestin administration. RESULTS: PAS was associated with ≥2 previous uterine surgeries (adjusted odds ratio, 3.57; 95 % confidence interval, 1.60-7.97) and the stage of embryo transfer (blastocysts: adjusted odds ratio, 2.89; 95 % confidence interval, 1.15-7.26). In patients with <2 previous uterine surgeries, PAS was associated with an endometrial thickness of <7.0 mm (adjusted odds ratio, 5.18; 95 % confidence interval, 1.10-24.44). CONCLUSION: Multiple uterine surgeries and the transfer of blastocysts are risk factors for PAS in pregnancies conceived after FET in an HRC. In women with <2 previous uterine surgeries, a thin endometrium before FET is also a risk factor for PAS in these pregnancies.


Asunto(s)
Placenta Accreta , Embarazo , Femenino , Humanos , Placenta Accreta/etiología , Estudios de Casos y Controles , Cesárea , Transferencia de Embrión/métodos , Progestinas , Criopreservación/métodos , Factores de Riesgo , Estudios Retrospectivos
4.
ESC Heart Fail ; 11(2): 1001-1008, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38234242

RESUMEN

AIMS: Myocardial fibrosis of the left ventricle (LV) is a prognostic factor in dilated cardiomyopathy (DCM). This study aims to evaluate whether fibrosis of right ventricular (RV) endomyocardial biopsy (EMB) can predict the degree of LV fibrosis beforehand in DCM. METHODS AND RESULTS: Fibrosis extent in 70 RV-EMB specimens of DCM diagnosis was compared with that in the whole cross-sectional LV of excised hearts in the same patients (52 explanted hearts for transplant and 18 autopsied hearts). The median interval between biopsy and excision was 4.1 (0.13-19.3) years. The fibrosis area ratio of the EMBs and excised hearts were evaluated via image analysis. The distribution of cardiovascular magnetic resonance-late gadolinium enhancement (LGE) in the intraventricular septum was classified into four quartile categories. The fibrosis area ratio in RV-EMB correlated significantly with that in the short-axis cut of the LV of excised hearts (r = 0.82, P < 0.0001) and with a diffuse pattern of LGE (r = 0.71, P = 0.003). In a multivariate model, after adjusting for the interval between biopsy performance and heart excision, the fibrosis area ratio in RV-EMB was associated with that in LV-excised heart (regression coefficient, 0.82; 95% confidence interval, 0.68-0.95; P < 0.0001). CONCLUSIONS: The fibrosis observed in RV-EMB positively correlated with the extent of fibrosis in the LV of excised hearts in patients with DCM. The study findings may help predict LV fibrosis, considered a prognostic factor of DCM through relatively accessible biopsy techniques.


Asunto(s)
Cardiomiopatía Dilatada , Humanos , Cardiomiopatía Dilatada/diagnóstico , Miocardio/patología , Ventrículos Cardíacos , Medios de Contraste , Estudios Transversales , Gadolinio , Fibrosis , Biopsia/métodos
5.
J Artif Organs ; 2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38190085

RESUMEN

There are no criteria for surgical mechanical circulatory system (MCS) selection for acute heart failure. Since 2021, we have utilized cardiopulmonary bypass system to assess patients' heart and lung condition to inform surgical MCS selection. we aimed to retrospectively analyze the outcomes of treatments administered using our protocol. We analyzed the data of 19 patients who underwent surgical MCS implantation. We compared patients' characteristics across the biventricular-assist device (BiVAD), central Y-Y extracorporeal membrane oxygenation (ECMO), central ECMO, and left VAD (LVAD) systems. Patients' diagnoses included fulminant myocarditis (47.4%), dilated cardiomyopathy (21.1%), acute myocardial infarction (15.8%), infarction from aortic dissection (5.3%), doxorubicin-related cardiomyopathy (5.3%), and tachycardia-induced myocarditis (5.3%). Eight patients (42.1%) underwent LVAD implantation, 1 (5.2%) underwent central ECMO, 4 (21.1%) underwent BiVAD implantation, and 6 (31.6%) underwent central Y-Y ECMO. 48 h after surgery, both the pulmonary arterial and right atrial pressures were effectively controlled, with median values being 19.0 mmHg and 9.0 mmHg, respectively. No patients transitioned from LVAD to BiVAD in the delayed period. Cerebrovascular events occurred in 21.1%. Successful weaning was achieved in 11 patients (57.9%), and 5 patients (26.3%) were converted to durable LVAD. Two-year cumulative survival was 84.2%. Our protocol showed good results for device selection in patients with heart failure, and device selection according to this protocol enabled good control of the pulmonary and systemic circulations.

6.
Org Biomol Chem ; 22(7): 1369-1373, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38232248

RESUMEN

A convenient method has been developed for transforming alkyl halides into the corresponding alcohols via an SN2 reaction. Treatment of an alkyl halide with the squarate dianion at high temperature produces mono-alkyl squarate, and a one-pot basic hydrolysis of the intermediate affords the alcohol in good yield.

7.
Gen Thorac Cardiovasc Surg ; 72(5): 324-330, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37709989

RESUMEN

OBJECTIVES: Progression of aortic insufficiency during left-ventricular assist device (LVAD) support is a crucial topic. One treatment option is aortic valvuloplasty (AVP); however, there is controversy regarding its safety and efficacy. We investigated the safety and efficacy of AVP using the coaptation stitch method (Park's stitch) performed for de novo aortic insufficiency. METHODS: Between 2013 and 2020, 175 consecutive patients underwent LVAD implantation, of which 7 patients [men, 2 (28.6%); median age, 55 years] underwent late-stage AVP. Two patients underwent AVP within 2 weeks, and the remaining six patients underwent AVP 3, 19, 24, 28, 42, and 49 months, respectively, after LVAD implantation. RESULTS: Preoperatively, the degree of aortic insufficiency was moderate in 6 (85.7%) patients and severe in 1 (14.3%) patient. AVP was technically successful in 6 (85.7%) patients, while one case of failed plasty was subsequently treated with bioprosthetic valve replacement. A 1-year post-AVP right heart catheterization study revealed a median pulmonary artery wedge pressure of 10.0 mmHg. No deaths or heart failure admissions occurred during the follow-up (median, 38.0 months). There was no aortic insufficiency in 2 (28.6%) patients; however, trivial AI was observed in 3 (42.8%) patients, and mild AI was observed in 1 (14.3%) patient 2 years postoperatively. However, at the 3-year follow-up, two patients developed an increase in AI grade from trivial to mild. CONCLUSIONS: AVP using Park's stitch was safe. It is critical to carefully observe the aortic valve during AVP surgery to ensure that AVP is appropriate.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Corazón Auxiliar , Masculino , Humanos , Persona de Mediana Edad , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia Cardíaca/terapia , Resultado del Tratamiento , Estudios Retrospectivos
8.
J Cardiol ; 83(3): 169-176, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37543193

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) does not benefit all patients. We performed a prospective multicenter study to investigate the cost-effectiveness of TAVR in a Japanese cohort. METHODS AND RESULTS: We prospectively enrolled 110 symptomatic patients with severe AS who underwent TAVR from five institutions. The quality of life measurement (QOL) was performed for each patient before and at 6 months after TAVR. Patients without an improvement in QOL at 6 months after TAVR were defined as non-responders. Pre-TAVR higher QOL, higher clinical frailty scale predicted the non-responders. Three models, 1) conservative treatment for all patients strategy, 2) TAVR for all patients strategy, and 3) TAVR for a selected patient strategy who is expected to be a responder, were simulated. Lifetime cost-effectiveness was estimated using incremental cost-effectiveness ratio (ICER) and cost per quality-adjusted life-year (QALY) gained. In comparison to conservative therapy for all patients, ICER was estimated to be 5,765,800 yen/QALY for TAVR for all patients and 2,342,175 yen/QALY for TAVR for selected patient strategy patients, which is less than the commonly accepted ICER threshold of 5,000,000 yen/QALY. CONCLUSIONS: TAVR for selected patient strategy model is more cost-effective than TAVR for all patient strategy without reducing QOL in the Japanese healthcare system. TAVR for selected patient strategy has potential benefit for optimizing the TAVR treatment in patients with high frailty and may direct our resources toward beneficial interventions.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Calidad de Vida , Análisis Costo-Beneficio , Estudios Prospectivos , Fragilidad/etiología , Estenosis de la Válvula Aórtica/etiología , Índice de Severidad de la Enfermedad , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo
9.
Kyobu Geka ; 76(13): 1131-1134, 2023 Dec.
Artículo en Japonés | MEDLINE | ID: mdl-38088079

RESUMEN

A rare case of isolated right atrial thrombus under anticoagulant therapy for atrial fibrillation is reported herein. The patient was an 81-year-old man undergoing anticoagulant therapy with oral warfarin for atrial fibrillation. During preoperative screening for eye surgery, echocardiography revealed a mobile mass in the right atrium, and emergency hospital admission was indicated. Excision of the right atrial thrombus was performed, and no residual thrombus was detected on postoperative imaging studies. This case was considered a good indication for surgical resection because of potential risk of fatal embolism.


Asunto(s)
Fibrilación Atrial , Cardiopatías , Trombosis , Masculino , Humanos , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Trombosis/cirugía , Anticoagulantes/efectos adversos
11.
JTCVS Open ; 15: 176-187, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37808062

RESUMEN

Objectives: Developments in both technique and technology have enabled surgeons to perform the maze procedure via right minithoracotomy (RMT) to treat atrial fibrillation (AF). This study aimed to clarify the outcomes of the modified cryomaze procedure via the RMT approach compared with the sternotomy approach. Methods: The study cohort comprised 803 consecutive patients who underwent a modified cryomaze procedure (130 via RMT and 673 via sternotomy) for paroxysmal AF and persistent AF from January 2001 to March 2022. The Gray test was applied to compare the incidence of recurrent atrial tachyarrhythmias. Additionally, residual electrical gaps were investigated in the patients who underwent additional catheter ablation for recurrent atrial tachyarrhythmias. Results: The respective 1-, 2-, and 3-year cumulative incidences of recurrent atrial tachyarrhythmias were 13.1%, 19.5%, and 23.1% in the RMT group, and 9.3%, 10.9%, and 12.8% in the sternotomy group (Gray test P = .036). All 31 patients with recurrent atrial tachyarrhythmias underwent additional catheter ablation, comprising 14 (10.8%) in the RMT group and 17 (2.5%) in the sternotomy group. There was a significant intergroup difference in the site of residual electrical gaps; the RMT group more frequently had residual gaps in the tricuspid annulus than the sternotomy group (6.2% vs 0.4%; P < .001). Conclusions: In the modified cryomaze procedure via the RMT approach, ablation failure is more likely to occur at the tricuspid annulus, where the surgical field of view is relatively poor compared with the sternotomy approach. Therefore, surgical ablation should be performed with caution when the RMT approach is used.

12.
J Cardiothorac Surg ; 18(1): 269, 2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37794433

RESUMEN

BACKGROUND: Post-implant right heart failure (RHF) has been recognized as a crucial prognostic factor in patients receiving left ventricular assist devices (LVADs), and its management has long attracted attention from cardiologists and surgeons. CASE PRESENTATION: This report described an 18-year-old female with acutely deteriorating heart failure due to dilated cardiomyopathy who underwent paracorporeal pulsatile-flow LVAD and developed early post-implant RHF. At postoperative day (POD) six, she was almost asymptomatic at rest on 2.5 mg/kg/min of dobutamine; however, the echocardiogram, performed as part of the daily postoperative care, revealed a severely enlarged right ventricle with a decompressed left ventricle, implying the development of post-implant RHF. Bolus infusion of saline and reduction of pump flow (6.0 L/min to 3.0 L/min) led to normalization of both ventricular shapes in 30 s, suggesting that RHF could be managed without surgical interventions. Milrinone was started on POD six, followed by sildenafil administration on POD seven. Fluid balance was strictly adjusted under the close observation of daily echocardiograms. Milrinone and dobutamine were discontinued on PODs 18 and 21, respectively. The patient was listed for a heart transplant on POD 40. Despite reduced right ventricular function (right ventricular stroke work index of 182.34 mmHg*ml/m- 2, body surface area 1.5 m2), she was successfully converted to implantable LVAD on POD 44 with no recurrence of post-implant RHF thereafter for four years. CONCLUSIONS: In post-implant RHF management, early detection, together with proper and prompt medical management, is crucial to avoiding any surgical intervention. Close observation of daily echocardiograms might be helpful in detecting subclinical RHF and is useful for post-implant medical management.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Femenino , Humanos , Adolescente , Milrinona , Corazón Auxiliar/efectos adversos , Dobutamina , Estudios Retrospectivos , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/cirugía , Ecocardiografía
13.
Bioorg Med Chem ; 93: 117461, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37659219

RESUMEN

The epigenetic regulation of the protein bromodomain-containing protein 4 (BRD4) has emerged as a compelling target for cancer treatment. In this study, we outline the discovery of a novel BRD4 inhibitor for melanoma therapy. Our initial finding was that benzimidazole derivative 1, sourced from our library, was a powerful BRD4 inhibitor. However, it exhibited a poor pharmacokinetic (PK) profile. To address this, we conducted a scaffold-hopping procedure with derivative 1, which resulted in the creation of benzimidazolinone derivative 5. This new derivative displayed an improved PK profile. To further enhance the BRD4 inhibitory activity, we attempted to introduce hydrogen bond acceptors. This indeed improved the activity, but at the cost of decreased membrane permeability. Our search for a potent inhibitor with desirable permeability led to the development of tricyclic 18. This compound demonstrated powerful inhibitory activity and a favorable PK profile. More significantly, tricyclic 18 showed antitumor efficacy in a mouse melanoma xenograft model, suggesting that it holds potential as a therapeutic agent for melanoma treatment.


Asunto(s)
Melanoma , Proteínas Nucleares , Animales , Ratones , Humanos , Epigénesis Genética , Factores de Transcripción , Melanoma/tratamiento farmacológico , Permeabilidad de la Membrana Celular , Proteínas de Ciclo Celular
14.
J Surg Case Rep ; 2023(8): rjad443, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37601245

RESUMEN

Driveline infection (DLI) is treated by local irrigation via driveline exit site (DLES) and surgical debridement is considered in patients with deep DLI. We describe three cases of deeply progressed superficial DLI that were considered to require surgical debridement but could be treated with a unique catheter cleaning method using intravenous indwelling catheter, a cotton swab with 10% silver nitrate solution and a monofilament nylon thread. Case 1 was a 60-y-old man with ischemic cardiomyopathy with left ventricular assist device implantation 2 y before. Daily bedside debridement with 10% silver nitrate solution was performed via the DLES. Case 2 was a 43-y-old man with ischemic cardiomyopathy who had recurrent DLI with methicillin-resistant Staphylococcus aureus, and case 3 was a 49-y-old woman with hypertrophic cardiomyopathy, who also showed improvement in their DLI with Pseudomonas aeruginosa. These cleaning methods may be useful for the deeply progressed superficial DLI.

15.
Eur J Obstet Gynecol Reprod Biol ; 288: 216-221, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37572451

RESUMEN

OBJECTIVE: Abdominal trachelectomy (AT) is a fertility-preservation surgery for patients with early-stage cervical cancer. Few studies have reported the outcomes of assisted reproductive technology (ART) in patients after AT. The aim of this study was to evaluate the outcomes of ART after AT. STUDY DESIGN: In this retrospective study, we compared the ART outcomes of 13 patients who underwent AT at another hospital prior to undergoing ART at our clinic (T group) and 52 control patients (non-T group) who did not undergo AT prior to ART, selected on the basis of age, time of treatment onset, and serum anti-Müllerian hormone concentrations, matched 1:4, respectively. RESULTS: Cumulative live birth rates were 62% (8/13) and 65% (34/52) in the T and non-T groups, respectively (p = 0.795). The total number of oocyte retrieval cycles was 34 in the T group and 95 in the non-T group. In all oocyte retrieval cycles, no significant differences were noted in the number of oocyte retrievals, rate of fertilization, and presence of good-quality blastocysts (Gardner classification ≥ BB). The total number of embryo transfer (ET) cycles was 55 in the T group and 109 in the non-T group. The pregnancy and live birth rates per ET were lower in the T group than those in the non-T group (pregnancy rate, 20% vs. 39%, p = 0.017; live birth rate, 15% vs. 30%, p = 0.028; respectively). Endometrial thickness before ET was lower in the T group vs. the non-T group: median (range): 7.4 (3.5-14.3) mm vs. 9.0 (5.5-14.9) mm, respectively; p < 0.0001. Multivariate logistic regression models showed that age at oocyte retrieval (adjusted odds ratio [OR], 0.76; 95% confidence interval [CI], 0.66-0.87), use of good-quality blastocysts (adjusted OR, 3.23; 95% CI, 1.20-8.67), and history of AT (adjusted OR, 0.28; 95% CI, 0.11-0.72) were associated with the pregnancy rate per ET. CONCLUSION: The pregnancy rate per ET was lower in patients with vs. without a history of AT. Clinicians should be aware of the longer time to pregnancy in patients who undergo ART after AT.


Asunto(s)
Traquelectomía , Embarazo , Humanos , Femenino , Índice de Embarazo , Estudios Retrospectivos , Nacimiento Vivo/epidemiología , Técnicas Reproductivas Asistidas , Transferencia de Embrión , Fertilización In Vitro
16.
Artif Organs ; 47(11): 1742-1751, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37578196

RESUMEN

BACKGROUND: Pulmonary complications often occur in patients receiving veno-arterial extracorporeal membrane oxygenation (VA ECMO). However, the prognostic impact of lung damage has not been fully elucidated. METHODS: This single-center retrospective observational study targeted patients with cardiogenic shock who received VA ECMO between 2012 and 2021. This study included 65 patients who underwent chest computed tomography (CT) on VA ECMO, followed by escalation to central mechanical circulatory support (MCS) with left ventricular venting. The average density of lung CT images was measured using region-of-interest methods, and the primary endpoint was 180-day all-cause death after escalation to the central MCS. RESULTS: Twenty-two patients (34%) developed 180-day all-cause death. According to the Cox regression analysis, age (hazard ratio [HR], 1.08; 95% confidence interval [CI], 1.03-1.14; p = 0.001), ischemic etiology (HR, 5.53; 95% CI, 2.09-14.62; p < 0.001), duration of VA ECMO support (HR, 1.19; 95% CI, 1.00-1.40; p = 0.045), and lung CT density (≥ -481 Hounsfield unit [HU]) (HR, 6.33; 95% CI, 2.26-17.72; p < 0.001) were independently associated with all-cause death. Receiver operating characteristic curve analysis determined that lung CT density ≥ -481 HU is an optimal cutoff value for predicting all-cause death (area under the curve [AUC], 0.72). The 180-day overall survival rate for patients with high lung CT density (≥ -481 HU) was significantly lower than that for those with low lung CT density (< -481 HU) (44.4% vs. 81.6%, respectively, p = 0.002). CONCLUSIONS: Higher lung CT density could be a useful predictor of death in patients with VA ECMO requiring central MCS escalation.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Choque Cardiogénico , Humanos , Pronóstico , Choque Cardiogénico/diagnóstico por imagen , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia , Oxigenación por Membrana Extracorpórea/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Pulmón/diagnóstico por imagen
17.
Gen Thorac Cardiovasc Surg ; 71(12): 692-699, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37418064

RESUMEN

BACKGROUND: Despite the growing popularity of robotically assisted mitral repair, robotically assisted tricuspid repair has not been widely adopted. We assessed the safety and feasibility of robotic tricuspid annuloplasty with continuous sutures for tricuspid regurgitation (TR). METHODS AND RESULTS: We studied consecutive 68 patients (median age, 74 years) with secondary TR who underwent tricuspid annuloplasty using continuous sutures with (n = 61) and without mitral valve repair (n = 7) from 2018 to 2021. Robotic tricuspid annuloplasty consists of continuous sutures with flexible prosthetic band to the tricuspid annulus using two V-Loc barbed sutures (Medtronic Inc., Minneapolis, MN). Concomitant maze procedure was performed in 45 (66%) patients. Robotic tricuspid annuloplasty with continuous sutures was successfully performed. There was no in-hospital or 30-day mortality; 65 patients (96%) did not experience major surgery-related complications. Preoperatively, the TR grade was mild in 20 (29%) patients and mildly higher in 48 (71%). Postoperatively, the TR severity significantly improved, with TR grade mildly higher in 9% at hospital discharge and 7% at 1-year follow-up (p < 0.001). The 1-year and 2-year freedom rates from heart failure were 98% and 95%, respectively. CONCLUSIONS: Robotic tricuspid annuloplasty with continuous sutures is safe and feasible alone or concomitant with mitral valve repair. It offered sustained improvement in TR severity and might prevent heart failure readmission.


Asunto(s)
Insuficiencia Cardíaca , Procedimientos Quirúrgicos Robotizados , Insuficiencia de la Válvula Tricúspide , Humanos , Anciano , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Mitral/cirugía , Procedimientos Quirúrgicos Robotizados/efectos adversos , Hospitales
18.
BMC Cardiovasc Disord ; 23(1): 281, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37264308

RESUMEN

BACKGROUND: Recent studies have reported atrial involvement and coexistence of aortic stenosis in transthyretin (ATTR) cardiac amyloidosis (CA). However, pathological reports of extraventricular ATTR amyloid deposits in atrial structures or heart valves are limited, and the clinical implications of ATTR amyloid deposits outside the ventricles are not fully elucidated. CASE PRESENTATION: We report 3 cases of extraventricular ATTR amyloid deposits confirmed in surgically resected aortic valves and left atrial structures, all of which were unlikely to have significant ATTR amyloidosis infiltrating the ventricles as determined by multimodality evaluation including 99mtechnetium-pyrophosphate scintigraphy, cardiac magnetic resonance, endomyocardial biopsy and their mid-term clinical course up to 5 years. These findings suggested that these were extraventricular ATTR amyloid deposits localized in the aortic valve and the left atrium. CONCLUSIONS: While long-term observation is required to fully clarify whether these extraventricular ATTR amyloid deposits are truly localized outside the ventricles or are early stages of ATTR-CA infiltrating the ventricles, our 3 cases with multimodality evaluations and mid-term follow up suggest the existence of extraventricular ATTR amyloid deposits localized in the aortic valve and left atrial structures.


Asunto(s)
Neuropatías Amiloides Familiares , Fibrilación Atrial , Cardiomiopatías , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Neuropatías Amiloides Familiares/diagnóstico por imagen , Estudios de Seguimiento , Placa Amiloide , Prealbúmina/genética , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Cardiomiopatías/diagnóstico por imagen
19.
J Am Heart Assoc ; 12(11): e028607, 2023 06 06.
Artículo en Inglés | MEDLINE | ID: mdl-37232245

RESUMEN

Background This study assessed risk factors for mitral regurgitation (MR) recurrence or functional mitral stenosis during long-term follow-up in patients undergoing mitral valve repair for isolated posterior mitral leaflet prolapse. Methods and Results We assessed a consecutive series of 511 patients who underwent primary mitral valve repair for isolated posterior leaflet prolapse between 2001 and 2021. Annuloplasty using a partial band was selected in 86.3%. The leaflet resection technique was used in 83.0%, whereas the chordal replacement without resection was used in 14.5%. Risk factors were analyzed for MR recurrence ≥grade 2 or functional mitral stenosis with mean transmitral pressure gradient ≥5 mm Hg using a multivariable Fine-Gray regression model. The 1-, 5-, and 10-year cumulative incidence of MR ≥grade 2 was 7.8%, 22.7%, and 30.1%, respectively, whereas that of mean transmitral pressure gradient ≥5 mm Hg was 8.1%, 20.6%, and 29.3%, respectively. Risk factors for MR ≥grade 2 included chordal replacement without resection (hazard ratio [HR], 2.50, P<0.001) and larger prosthesis size (HR, 1.13, P=0.023), whereas factors for functional mitral stenosis were use of a full ring (partial band versus full ring, HR, 0.53, P=0.013), smaller prosthesis size (HR, 0.74, P<0.001), and larger body surface area (HR, 3.03, P=0.045). Both MR ≥grade 2 and mean transmitral pressure gradient ≥5 mm Hg at 1 year post surgery were significantly associated with the long-term incidence of reoperation. Conclusions Leaflet resection with a large partial band may be an optimal strategy for isolated posterior mitral valve prolapse.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Estenosis de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Estenosis de la Válvula Mitral/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Prolapso
20.
Acta Obstet Gynecol Scand ; 102(7): 914-920, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37194424

RESUMEN

INTRODUCTION: We aimed to describe physiological changes in endometrial blood flow (minute arterioles running through the endometrium) from ovulation to the mid-luteal phase using superb microvascular imaging. MATERIAL AND METHODS: The study involved 17 women (median age, 32.5 years; first to third interquartile range, 29.8-40.0 years) with regular menstrual cycles who were managed in our institute from 2020 to 2021. The uterus was delineated at the sagittal section using transvaginal ultrasonography incorporated with superb microvascular imaging. For each participant, a total of 28 cycles were observed; 17 cycles observed within one day of ovulation and the implantation period, 5-7 days (D5-7) after ovulation in the same cycle, and nine cycles in which only ovulation was observed, and two cycles in which only D5-7 was observed. Therefore, 26 and 19 images at ovulation and D5-7, respectively, were acquired. Endometrial blood flow was evaluated by depth of the vascular signal in the endometrium and categorized as follows: signals only in the basal layer of the endometrium (grade 1), reaching up to half the endometrium (grade 2), and covering the whole endometrium (grade 3). Changes in the grade of endometrial blood flow from ovulation to D5-7 after ovulation, and the relationship between the grade of endometrial blood flow and the endometrial thickness on ovulation and D5-7 after ovulation, were analyzed. Statistical significance was set at p < 0.05. RESULTS: The endometrial blood flow from ovulation to D5-7 after ovulation during the same menstrual period showed a downgrade in 14 of 17 cycles (82.3%) and no change in the remaining three cycles (17.6%), indicating a decrease in the endometrial blood flow from ovulation to D5-7 after ovulation (p = 0.001). There were differences between the grade of endometrial blood flow and median endometrial thickness on ovulation (grade 1: 5.9 mm, grade 2: 9.1 mm, and grade 3: 11.2 mm); however, no differences in the endometrial thickness were found between the grades on D5-7 after ovulation. CONCLUSIONS: In the normal menstrual cycle, endometrial blood flow decreased from ovulation to the mid-luteal phase, and the endometrial thickness in the ovulatory phase was related to the endometrial perfusion.


Asunto(s)
Endometrio , Fase Luteínica , Femenino , Humanos , Adulto , Endometrio/diagnóstico por imagen , Ovulación/fisiología , Ciclo Menstrual/fisiología , Útero/irrigación sanguínea
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...