Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Europace ; 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39271126

RESUMEN

BACKGROUND: Several algorithms can differentiate inferior axis premature ventricular contractions (PVCs) originating from the right side and left side on 12-lead electrocardiograms (ECGs). However, it is unclear whether distinguishing the origin should rely solely on PVC or incorporate sinus rhythm (SR). AIMS: We compared the Dual-Rhythm model (incorporating both SR and PVC) to the PVC model (using PVC alone), and quantified the contribution of each ECG lead in predicting the PVC origin for each cardiac rotation. METHODS: This multicenter study enrolled 593 patients from 11 centers-493 from Japan and Germany, and 100 from Belgium, which used as the external validation dataset. Using a hybrid approach combining a Resnet50-based convolutional neural network and a Transformer model, we developed two variants-the PVC and Dual-Rhythm models-to predict PVC origin. RESULTS: In the external validation dataset, the Dual-Rhythm model outperformed the PVC model in accuracy (0.84 vs. 0.74, respectively; p < 0.01), precision (0.73 vs. 0.55, respectively; p < 0.01), specificity (0.87 vs. 0.68, respectively; p < 0.01), area under the receiver operating characteristic curve (0.91 vs. 0.86, respectively; p = 0.03), and F1-Score (0.77 vs. 0.68, respectively; p = 0.03). The contributions to PVC origin prediction were 77.3% for PVC and 22.7% for the SR. However, in patients with counterclockwise rotation, SR had a greater contribution in predicting the origin of right-sided PVC. CONCLUSIONS: Our deep learning-based model, incorporating both PVC and SR morphologies, resulted in a higher prediction accuracy for PVC origin. Considering SR is particularly important for predicting right-sided origin in patients with counterclockwise rotation.

2.
Catheter Cardiovasc Interv ; 101(3): 528-535, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36617385

RESUMEN

BACKGROUND: Kissing balloon inflation with distal guide wire recross can cause severe stent deformation depending on the stent link location with respect to the carina. The balloon-push technique, by which an inflated balloon is forced into the SB from the proximal main vessel (MV), is a feasible way to remove jailed struts without causing severe stent deformation. AIMS: We investigated the procedural success rate, patterns of jailed strut removal at side branch (SB) orifices, factors related to failure of jailed strut removal, and follow-up angiogram results of the balloon-push technique. METHODS: Between September 2015 and December 2020, 51 bifurcation stenting cases in which the balloon-push technique was used were enrolled. Based on three-dimensional optical coherence tomography images, strut removal with 1 stent crown length was defined as successful. Strut removal patterns were classified into two types: parallel-slide type (stent struts shifted distally into the MV lumen without inversion) and under-carina type (stent struts shifted distally under the carina with strut inversion or strut slide). RESULTS: Procedural success was attained in 39 cases (success rate: 76.5%). Parallel-slide type and under-carina type occurred in 43% and 33% of cases, respectively. Factors related to failure were trifurcation lesions and a smaller pushed balloon-SB artery ratio compared with those in success cases (0.95 ± 0.18 vs. 1.10 ± 0.22, p = 0.032). Follow-up angiography was performed in 37 cases, and 2 cases had binary in-stent restenosis. CONCLUSIONS: Removal of jailed struts with the balloon-push technique was feasible, without severe stent deformation, in bifurcation stentings.


Asunto(s)
Enfermedad de la Arteria Coronaria , Tomografía de Coherencia Óptica , Humanos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Resultado del Tratamiento , Stents , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia
3.
Circ J ; 86(2): 256-265, 2022 01 25.
Artículo en Inglés | MEDLINE | ID: mdl-34334554

RESUMEN

BACKGROUND: The use of iodine contrast agents is one possible limitation in cryoballoon ablation (CBA) for atrial fibrillation (AF). This study investigated intracardiac echography (ICE)-guided contrast-free CBA.Methods and Results:The study was divided into 2 phases. First, 25 paroxysmal AF patients (Group 1) underwent CBA, and peri-balloon leak flow velocity (PLFV) was assessed using ICE and electrical pulmonary vein (PV) lesion gaps were assessed by high-density electroanatomical mapping. Then, 24 patients (Group 2) underwent ICE-guided CBA and were compared with 25 patients who underwent conventional CBA (historical controls). In Group 1, there was a significant correlation between PLFV and electrical PV gap diameter (r=-0.715, P<0.001). PLFV was higher without than with an electrical gap (mean [±SD] 127.0±28.6 vs. 66.6±21.0 cm/s; P<0.001) and the cut-off value of PLFV to predict electrical isolation was 105.7 cm/s (sensitivity 0.700, specificity 0.929). In Group 2, ICE-guided CBA was successfully performed with acute electrical isolation of all PVs and without the need for "rescue" contrast injection. Atrial tachyarrhythmia recurrence at 6 months did not differ between ICE-guided and conventional CBA (3/24 [12.5%] vs. 5/25 [20.0%], respectively; P=0.973, log-rank test). CONCLUSIONS: PLFV predicted the presence of an electrical PV gap after CBA. ICE-guided CBA was feasible and safe, and could potentially be performed completely contrast-free without a decrease in ablation efficacy.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/efectos adversos , Criocirugía/métodos , Ecocardiografía/métodos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
4.
Sci Rep ; 11(1): 8045, 2021 04 13.
Artículo en Inglés | MEDLINE | ID: mdl-33850245

RESUMEN

Cardiac accessory pathways (APs) in Wolff-Parkinson-White (WPW) syndrome are conventionally diagnosed with decision tree algorithms; however, there are problems with clinical usage. We assessed the efficacy of the artificial intelligence model using electrocardiography (ECG) and chest X-rays to identify the location of APs. We retrospectively used ECG and chest X-rays to analyse 206 patients with WPW syndrome. Each AP location was defined by an electrophysiological study and divided into four classifications. We developed a deep learning model to classify AP locations and compared the accuracy with that of conventional algorithms. Moreover, 1519 chest X-ray samples from other datasets were used for prior learning, and the combined chest X-ray image and ECG data were put into the previous model to evaluate whether the accuracy improved. The convolutional neural network (CNN) model using ECG data was significantly more accurate than the conventional tree algorithm. In the multimodal model, which implemented input from the combined ECG and chest X-ray data, the accuracy was significantly improved. Deep learning with a combination of ECG and chest X-ray data could effectively identify the AP location, which may be a novel deep learning model for a multimodal model.


Asunto(s)
Aprendizaje Profundo , Fascículo Atrioventricular Accesorio , Estudios Retrospectivos , Síndrome de Wolff-Parkinson-White
5.
Heart Vessels ; 36(11): 1661-1669, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33830317

RESUMEN

This retrospective, single-center study evaluated the patency rate and predictors of restenosis after percutaneous transluminal angioplasty (PTA) for femoropopliteal stenotic lesions using intravascular ultrasound. We assessed 78 de novo femoropopliteal stenotic lesions (64 patients; mean age, 73.6 ± 9.4 years; average lesion length, 59.8 mm) that underwent PTA under intravascular ultrasound guidance. The primary endpoint was 1-year primary patency. The 1-year primary patency rate was 63%. The frequency of insulin use was significantly greater (44% vs. 12%, p = 0.005), and lesions were significantly longer (77.8 mm vs. 49.2 mm, p = 0.047) in the restenosis group than in the non-restenosis group. The pre-intervention reference lumen area and minimum lumen area (MLA) were significantly smaller in the restenosis group (reference lumen area: 19.7 ± 6.7 mm2 vs. 23.7 ± 7.4 mm2, p = 0.017; MLA 3.9 ± 2.8 mm2 vs. 5.7 ± 3.9 mm2, p = 0.026; respectively). The MLA was significantly smaller and the maximum angle of dissection was significantly larger in the restenosis group (MLA 9.3 mm2 vs. 12.3 mm2, p = 0.013; maximum angle of dissection: 104.1° vs. 69.6°, p = 0.003; respectively) among post-intervention parameters. Multivariate analysis revealed that the independent predictors of 1-year restenosis were the large post-intervention maximum angle of dissection and insulin use. Per receiver operating curve analysis, the best cut-off value of the post-intervention maximum angle of dissection that predicted 1-year restenosis was 70.2° (sensitivity 72.4%, specificity 63.3%, area under the curve 0.70, p = 0.004). In conclusion, the 1-year primary patency rate after PTA for relatively short stenotic femoropopliteal lesions was 63%. The large post-intervention maximum angle of dissection, measured using intravascular ultrasound, and insulin use were independent predictors of restenosis after PTA.


Asunto(s)
Angioplastia de Balón , Insulinas , Anciano , Anciano de 80 o más Años , Angioplastia/métodos , Constricción Patológica , Humanos , Persona de Mediana Edad , Arteria Poplítea/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos
6.
Circ J ; 85(3): 264-271, 2021 02 25.
Artículo en Inglés | MEDLINE | ID: mdl-33431721

RESUMEN

BACKGROUND: Coronary artery spasms (CASs), which can cause angina attacks and sudden death, have been recently reported during catheter ablation. The aim of the present study was to report the incidence, characteristics, and prognosis of CASs related to atrial fibrillation (AF) ablation procedures.Methods and Results:The AF ablation records of 22,232 patients treated in 15 Japanese hospitals were reviewed. CASs associated with AF ablation occurred in 42 of 22,232 patients (0.19%). CASs occurred during ablation energy applications in 21 patients (50%). CASs also occurred before ablation in 9 patients (21%) and after ablation in 12 patients (29%). The initial change in the electrocardiogram was ST-segment elevation in the inferior leads in 33 patients (79%). Emergency coronary angiography revealed coronary artery stenosis and occlusions, which were relieved by nitrate administration. No air bubbles were observed. A comparison of the incidence of CASs during pulmonary vein isolation between the different ablation energy sources revealed a significantly higher incidence with cryoballoon ablation (11/3,288; 0.34%) than with radiofrequency catheter, hot balloon, or laser balloon ablation (8/18,596 [0.04%], 0/237 [0%], and 0/111 [0%], respectively; P<0.001). CASs most often occurred during ablation of the left superior pulmonary vein. All patients recovered without sequelae. CONCLUSIONS: CASs related to AF ablation are rare, but should be considered as a dangerous complication that can occur anytime during the periprocedural period.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Vasoespasmo Coronario , Venas Pulmonares , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Vasoespasmo Coronario/epidemiología , Vasoespasmo Coronario/etiología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Humanos , Incidencia , Venas Pulmonares/cirugía , Espasmo , Resultado del Tratamiento
7.
J Atheroscler Thromb ; 28(9): 954-962, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-33100279

RESUMEN

AIM: The predictors of restenosis after endovascular therapy (EVT) with paclitaxel drug-coated balloons (DCBs) have not been clearly established. The present study aimed to investigate the association of post-procedural dissection, as evaluated using intravascular ultrasound (IVUS), with the risk of restenosis following femoropopliteal EVT with paclitaxel DCBs. METHODS: In the present single-center retrospective study, 60 de novo femoropopliteal lesions (44 patients) that underwent EVT with DCBs, without bail-out stenting, were enrolled. The primary outcome was 1-year primary patency. Risk factors for restenosis were evaluated using a Cox proportional hazards regression model and random survival forest analysis. RESULTS: The 1-year primary patency rate was 57.2% [95% confidence interval, 45%-72%]. IVUS-evaluated post-procedural dissection was significantly associated with the risk of restenosis (P=0.002), with the best cutoff point of 64º [range, 39º-83º]. The random survival forest analysis showed that the variable importance measure of IVUS-evaluated dissection was significantly lower than that of the reference vessel diameter (P<0.001), not different from that of the lesion length (P=0.41), and significantly higher than that of any other clinical feature (all P<0.05). CONCLUSION: IVUS-evaluated post-procedural dissection was associated with 1-year restenosis following femoropopliteal EVT with DCB.


Asunto(s)
Procedimientos Endovasculares , Paclitaxel/uso terapéutico , Enfermedad Arterial Periférica/terapia , Moduladores de Tubulina/uso terapéutico , Dispositivos de Acceso Vascular , Anciano , Anciano de 80 o más Años , Constricción Patológica/diagnóstico , Constricción Patológica/etiología , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Paclitaxel/administración & dosificación , Enfermedad Arterial Periférica/diagnóstico , Pronóstico , Estudios Retrospectivos , Resultado del Tratamiento , Moduladores de Tubulina/administración & dosificación , Dispositivos de Acceso Vascular/efectos adversos
9.
Heart Rhythm ; 16(1): 128-139, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30075279

RESUMEN

BACKGROUND: Air embolisms are serious complications during catheter ablation procedures. OBJECTIVES: The aims of the present study were to determine when air bubbles enter the left atrium (LA) during catheter ablation procedures and to identify techniques that reduce air bubble intrusion. METHODS: An ex vivo study was performed to monitor air bubbles using a silicone heart model and a high-resolution camera. In total, 280 radiofrequency catheter and cryoballoon ablation processes were tested. RESULTS: Small and large air bubbles were often observed during catheter ablation processes. Many small air bubbles arose during sheath flushing at fast speeds (15 mL/2 s) (median bubble number [quartiles]: 35 [20-53] for SL0, 35 [23-44] for Agilis, and 98 [91-100] for FlexCath) and during initial cryoballoon inflation/freezing/deflation (34 [22-47]). Large (≥1.5 mm) air bubbles were observed during Lasso catheter insertion (1 [0-1]), cryoballoon insertion (2 [1-2]), and initial inflation/freezing/deflation (1 [1-3]). Massive air bubbles were observed during Optima catheter insertion into the sheath using an inserter (10 [2-15]). Sheath flushing at slow speeds (15 mL/5 s) significantly reduced the number of air bubbles. Before cryoballoon insertion, temporary balloon inflation and air bubble removal from the inflated surface were most effective in reducing air bubble intrusions. Optima catheter insertion without an inserter significantly reduced large air bubble intrusion. CONCLUSION: Air bubbles entered the LA at specific times. Techniques such as sheath flushing at slow speeds, temporary cryoballoon inflation before insertion, inserting the Optima catheter without an inserter, and avoidance of negative pressure in the LA could reduce air bubble intrusion.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía/métodos , Sistema de Conducción Cardíaco/fisiopatología , Venas Pulmonares/cirugía , Cirugía Asistida por Computador/métodos , Grabación en Video/instrumentación , Aire , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Diseño de Equipo , Atrios Cardíacos , Sistema de Conducción Cardíaco/cirugía , Humanos , Resultado del Tratamiento
12.
Europace ; 19(1): 40-47, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26826137

RESUMEN

AIMS: A recent large clinical study demonstrated the association between intermediate CD14++CD16+monocytes and cardiovascular events. However, whether that monocyte subset contributes to the pathogenesis of atrial fibrillation (AF) has not been clarified. We compared the circulating monocyte subsets in AF patients and healthy people, and investigated the possible role of intermediate CD14++CD16+monocytes in the pathophysiology of AF. METHODS AND RESULTS: This case-control study included 44 consecutive AF patients without systemic diseases referred for catheter ablation at our hospital, and 40 healthy controls. Patients with systemic diseases, including structural heart disease, hepatic or renal dysfunction, collagen disease, malignancy, and inflammation were excluded. Monocyte subset analyses were performed (three distinct human monocyte subsets: classical CD14++CD16-, intermediate CD14++CD16+, and non-classical CD14+CD16++monocytes). We compared the monocyte subsets and evaluated the correlation with other clinical findings. A total of 60 participants (30 AF patients and 30 controls as an age-matched group) were included after excluding 14 AF patients due to inflammation. Atrial fibrillation patients had a higher proportion of circulating intermediate CD14++CD16+monocytes than the controls (17.0 ± 9.6 vs. 7.5 ± 4.1%, P < 0.001). A multivariable logistic regression analysis demonstrated that only the proportion of intermediate CD14++CD16+monocytes (odds ratio: 1.316; 95% confidence interval: 1.095-1.582, P = 0.003) was independently associated with the presence of AF. Intermediate CD14++CD16+monocytes were negatively correlated with the left atrial appendage flow during sinus rhythm (r= -0.679, P = 0.003) and positively with the brain natriuretic peptide (r = 0.439, P = 0.015). CONCLUSION: Intermediate CD14++CD16+monocytes might be closely related to the pathogenesis of AF and reflect functional remodelling of the left atrium.


Asunto(s)
Fibrilación Atrial/sangre , Función del Atrio Izquierdo , Remodelación Atrial , Receptores de Lipopolisacáridos/sangre , Monocitos/inmunología , Receptores de IgG/sangre , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/inmunología , Fibrilación Atrial/fisiopatología , Biomarcadores/sangre , Estudios de Casos y Controles , Distribución de Chi-Cuadrado , Femenino , Proteínas Ligadas a GPI/sangre , Humanos , Japón , Modelos Logísticos , Masculino , Persona de Mediana Edad , Monocitos/clasificación , Análisis Multivariante , Péptido Natriurético Encefálico/sangre , Oportunidad Relativa , Valor Predictivo de las Pruebas , Regulación hacia Arriba
13.
J Arrhythm ; 32(1): 36-41, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26949429

RESUMEN

BACKGROUND: Even with the use of a reduced energy setting (20-25 W), excessive transmural injury (ETI) following catheter ablation of atrial fibrillation (AF) is reported to develop in 10% of patients. However, the incidence of ETI depends on the pulmonary vein isolation (PVI) method and its esophageal temperature monitor setting. Data comparing the incidence of ETI following AF ablation with and without esophageal temperature monitoring (ETM) are still lacking. METHODS: This study was comprised of 160 patients with AF (54% paroxysmal, mean: 24.0±2.9 kg/m(2)). Eighty patients underwent ablation accompanied by ETM. The primary endpoint was defined as the occurrence of ETI assessed by endoscopy within 5 d after the AF ablation. The secondary endpoint was defined as AF recurrence after a single procedure. If the esophageal temperature probe registered >39 °C, the radiofrequency (RF) application was stopped immediately. RF applications could be performed in a point-by-point manner for a maximum of 20 s and 20 W. ETI was defined as any injury that resulted from AF ablation, including esophageal injury or periesophageal nerve injury (peri-ENI). RESULTS: The incidence of esophageal injury was significantly lower in patients whose AF ablation included ETM compared with patients without ETM (0 [0%] vs. 6 [7.5%], p=0.028), but not the incidence of peri-ENI (2 [2.5%] vs. 3 [3.8%], p=1.0). AF recurrence 12 months after the procedure was similar between the groups (20 [25%] in the ETM group vs. 19 [24%] in the non-ETM group, p=1.00). CONCLUSIONS: Catheter ablation using ETM may reduce the incidence of esophageal injury without increasing the incidence of AF recurrence but not the incidence of peri-ENI.

14.
J Interv Card Electrophysiol ; 46(2): 161-6, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26781786

RESUMEN

BACKGROUND: The recurrence rates of atrial fibrillation (Af) after ablation are still high, and repeat procedures are required in these patients. The main reason for Af recurrence is the recovery of the conduction between the pulmonary veins and left atrium. The importance of catheter stability during the pulmonary vein isolation (PVI) is not well studied. PURPOSE: The purpose of this study was to evaluate the contact force (CF), stable ablation time, and power during conduction blocking lesion formation for PVI. METHODS: Thirty-two consecutive drug-refractory Af patients who underwent an initial PVI using CARTO 3 and Visitag were included. The CF, ablation time, force time integral (FTI), and ablation power were recorded by Visitag. Residual conduction gap points requiring touch-up ablation after an encircling linear ablation (R point), spontaneous reconnection points (S point), and dormant conduction points (D point) were considered as non-conduction blocking lesion points. Each ablation parameter for the non-conduction blocking lesion points was compared with the other lesion points. RESULTS: Twenty-one points in 16 patients were considered non-conduction blocking lesions. Ten were R, eight were S, and three were D points. The CF, ablation time, FTI, and power at the non-conduction blocking lesion points and other points were 12.0 g (7.0-21.5) and 12.0 g (9.0-16.0) (P = 0.9), 7.7 s (5.6-10.1) and 12.5 s (9.4-16.8) (P < 0.05), 103.0 g*s (62.0-174.5) and 149.0 g*s (104.0-213.0) (P < 0.05), and 30.0 W (22.5-30.0) and 30.0 W (30.0-30.0) (P = 0.06), respectively. CONCLUSIONS: Shorter ablation time recorded in Visitag lead to non-conduction blocking lesion.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Sistema de Conducción Cardíaco/cirugía , Venas Pulmonares/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Mapeo del Potencial de Superficie Corporal , Femenino , Humanos , Masculino , Movimiento (Física) , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Programas Informáticos , Estrés Mecánico , Resultado del Tratamiento
15.
J Cardiol ; 67(5): 424-9, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26347219

RESUMEN

BACKGROUND: This study aimed to assess chronic-phase suppression of neointimal proliferation and arterial healing following paclitaxel-coated (PTX) and bare metal stent (BMS) implantation in the superficial femoral artery using optical coherence tomography (OCT). METHODS: Twenty-five patients with 68 stents underwent an 8-month OCT follow-up. Besides standard OCT variables, neointimal characterization and frequencies of peri-strut low-intensity area (PLIA), macrophage accumulation, and in-stent thrombi were evaluated. RESULTS: The mean neointimal thickness was significantly less with PTX stents (544.9±202.2 µm vs. 865.0±230.6 µm, p<0.0001). The covered and uncovered strut frequencies were significantly smaller and larger, respectively, in the PTX stent group vs. the BMS group (93.7% vs. 99.4%; p<0.0001, 4.0% vs. 0.4%; p<0.0001, respectively). Heterogeneous neointima was only observed in the PTX stent group (12.5% vs. 0%, p=0.017). The frequencies of PLIA and macrophage accumulation were significantly greater in the PTX stent group (87.2% vs. 67.6%, p=0.001 and 46% vs. 9.1%, p=0.003, respectively). CONCLUSION: After 8 months, reduced neointimal proliferation was observed with PTX stent implantation. On the other hand, delayed arterial healing was observed compared with BMS.


Asunto(s)
Arteria Femoral/diagnóstico por imagen , Stents , Tomografía de Coherencia Óptica , Cicatrización de Heridas , Anciano , Aleaciones , Femenino , Humanos , Macrófagos/metabolismo , Masculino , Neointima/diagnóstico por imagen , Paclitaxel , Estudios Retrospectivos
16.
J Arrhythm ; 31(5): 286-92, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26550084

RESUMEN

BACKGROUND: Catheter ablation (CA) is an established therapy for atrial fibrillation (AF). However, the assessment of anatomical information and predictors of AF recurrence remain unclear. We investigated the relationship between anatomical information on the left atrium (LA) and pulmonary veins (PVs) from three-dimensional computed tomography images and the recurrence of AF after CA. METHODS: Sixty-seven consecutive AF patients (mean age: 62±10 years, median AF history: 42 (12; 60) months, mean LA size: 41±7 mm, paroxysmal: 56%) underwent CA and were followed for 19±10 months. The segmented surface areas (antral, posterior, septal, and lateral) and dimensions (between the anterior and posterior walls, the right inferior PV and mitral annulus [MA], the right superior PV and MA, the left superior PV and MA, and the mitral isthmus) of the LA were evaluated three dimensionally using the NavX system. The cross-sectional areas of the PVs were also evaluated. RESULTS: After the follow-up period, 49 patients (73%) remained free from AF. A multivariate analysis showed that the diameter of the mitral isthmus and cross-sectional area of the right upper PV were associated with AF recurrence (odds ratio: 1.070, CI: 1.02-1.12, p=0.001; odds ratio: 0.41, CI: 0.21-0.77, p=0.006). CONCLUSION: Enlargement of the mitral isthmus and a smaller right superior PV cross-sectional area were associated with AF recurrence.

17.
J Arrhythm ; 31(3): 122-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26336545

RESUMEN

BACKGROUND: Outcomes related to prophylactic catheter ablation (PCA) for ventricular tachycardia (VT) before implantable cardioverter-defibrillator (ICD) implantation in non-ischemic cardiomyopathy (NICM) are not well characterized. We assessed the efficacy of single endocardial PCA in NICM patients. METHODS: We retrospectively analyzed 101 consecutive NICM patients with sustained VT. We compared clinical outcomes of patients who underwent PCA (ABL group) with those who did not (No ABL group). Successful PCA was defined as no inducible clinical VT. We also compared the clinical outcomes of patients with successful PCA (PCA success group) with those of the No ABL group. Endpoints were appropriate ICD therapy (shock and anti-tachycardia pacing) and the occurrence of electrical storm (ES). RESULTS: PCA was performed in 42 patients, and it succeeded in 20. The time to ES occurrence was significantly longer in the ABL group than in the No ABL group (p=0.04). The time to first appropriate ICD therapy and ES occurrence were significantly longer in the PCA success group than in the No ABL group (p=0.02 and p<0.01, respectively). CONCLUSION: Single endocardial PCA can decrease ES occurrence in NICM patients. However, high rates of VT recurrence and low success rates are issues to be resolved; therefore, the efficacy of single endocardial PCA is currently limited.

18.
J Arrhythm ; 31(4): 221-5, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26336563

RESUMEN

BACKGROUND: We reviewed the effectiveness and safety of cardiac resynchronization therapy (CRT) for patients with New York Heart Association (NYHA) class IV non-ambulatory heart failure (NAHF). METHODS: From 2006 to 2011, 310 patients underwent CRT at Kobe University Hospital and Himeji Cardiovascular Center because of heart failure. Of these, 29 NAHF patients were retrospectively analyzed. The control group comprised 21 age- and ejection fraction-matched patients with NAHF who did not undergo CRT from the ICU database of Kobe University Hospital. The primary endpoint was all-cause death and hospitalization for heart failure. Response was defined as a >15% reduction in left ventricular end-systolic volume (LVESV). RESULTS: CRT was performed successfully without serious complications in all patients. Twenty-three patients (79%) were discharged 19±15 days after CRT implantation, while 6 (21%) died during their hospital stay due to progressive heart failure. Compared with the control group, patients in the CRT group showed significant improvements in the primary endpoint (log-rank p=0.04). Six patients (21%) were defined as responders and the Kaplan-Meier curve showed that responders experienced a better outcome than non-responders (log-rank p=0.029). LV dyssynchrony before implantation was significantly related to the occurrence of the primary endpoint (p=0.02). CONCLUSIONS: CRT can be safely used in patients with NAHF and can improve long-term patient outcomes, especially in treatment responders.

19.
Pacing Clin Electrophysiol ; 38(5): 608-16, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25644937

RESUMEN

BACKGROUND: The precise location of truly active reentry circuits of typical atrial flutter (AFL) has not been well identified. The purpose of this study was to verify our hypothesis that the posterior block line is located along the posteromedial right atrium (PMRA) and the crista terminalis (CT) is the anterior pathway of AFL, with real-time intracardiac echo (ICE). METHODS: The entire right atrium (RA) three-dimensional activation and entrainment mapping were evaluated during AFL in 18 patients using CARTO sound. RESULTS: The CT was clearly visualized by ICE and the local electrograms along the CT were single potentials in all the patients. The CT was recognized as the truly active anterior pathway based on entrainment mapping in all patients. Double potentials were recorded along the PMRA. Entire RA entrainment mapping could be performed in 16 patients. The reentry circuits were separated into three passages. The first was around the tricuspid annulus (TA), the second the anterior superior vena cava (SVC; AFL waves passed between the anterior SVC and RA appendage), and the last the posterior SVC (between the posterior SVC and upper limit of the PMRA). All three of these passages were active in four, around the TA and anterior SVC in eight, around the TA and posterior SVC in three, and around only the anterior SVC in one patient. CONCLUSIONS: The CT functions as the anterior pathway of typical AFL, and the posterior block line was located along the PMRA. Dual or triple circuits were recognized in the majority of AFL patients.


Asunto(s)
Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/fisiopatología , Ecocardiografía/métodos , Anciano , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Sistema de Conducción Cardíaco , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino
20.
Europace ; 17(9): 1407-14, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25662988

RESUMEN

AIMS: Left bundle branch block (LBBB) induces mechanical dyssynchrony, thereby compromising the coronary circulation in non-ischaemic cardiomyopathy. We sought to examine the effects of cardiac resynchronization therapy (CRT) on coronary flow dynamics and left ventricular (LV) function. METHODS AND RESULTS: Twenty-two patients with non-ischaemic cardiomyopathy (New York Heart Association class, III or IV; LV ejection fraction, ≤35%; QRS duration, ≥130 ms) were enrolled. One week after implantation of the CRT device, coronary flow velocity and pressure in the left anterior descending coronary artery (LAD) and left circumflex coronary artery (LCx) were measured invasively, before and after inducing hyperemia by adenosine triphosphate administration, with two programming modes: sequential atrial and biventricular pacing (BiV) and atrial pacing in patients with LBBB or sequential atrial and right ventricular pacing in patients with complete atrioventricular block (Control). We assessed hyperemic microvascular resistance (HMR, mean distal pressure divided by hyperemic average peak velocity) and the relationship between the change in HMR and mid-term LV reverse remodelling. Hyperemic microvascular resistance was lower during BiV than during Control (LAD: 1.76 ± 0.47 vs. 1.54 ± 0.45, P < 0.001; LCx: 1.92 ± 0.42 vs. 1.73 ± 0.31, P = 0.003). The CRT-induced change in HMR of the LCx correlated with the percentage change in LV ejection fraction (R = -0.598, P = 0.011) and LV end-systolic volume (R = 0.609, P = 0.010) before and 6 months after CRT. CONCLUSION: Cardiac resynchronization therapy improves coronary flow circulation by reducing microvascular resistance, which might be associated with LV reverse remodelling.


Asunto(s)
Bloqueo de Rama/fisiopatología , Terapia de Resincronización Cardíaca/métodos , Cardiomiopatías/cirugía , Vasos Coronarios/fisiopatología , Ventrículos Cardíacos/fisiopatología , Anciano , Ecocardiografía , Electrocardiografía , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Función Ventricular Izquierda , Remodelación Ventricular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA