Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Magn Reson Med Sci ; 20(4): 359-370, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-33390560

RESUMEN

PURPOSE: Non-calcified cholesterol stones that are small in size are hard to be depicted on CT or magnetic resonance cholangiopancreatography. This institutional review board (IRB)-approved retrospective in vitro study aims to characterize contrast behaviors of 3 main components of the gallstones, i.e., cholesterol component (CC), bilirubin calcium component (BC) and CaCO3 (CO) on 3D radial scan with ultrashort TE (UTE) MRI, and to test the capability of depicting CC of gallstones as bright signals as compared to background saline. METHODS: Fourteen representative gallstones from 14 patients, including 15 CC, 6 BC and 4 CO, were enrolled. The gallstones underwent MRI including fat-saturated T1-weighted image (fs-T1WI) and UTE MRI with dual echoes. The contrast-to-noise ratio (CNR) and the chemical analysis for the 25 portions of the stones were compared. RESULTS: BC was bright on fs-T1WI, which did not change dramatically on UTE MRI and the signal did not remain on UTE subtraction image between dual echoes. Whereas the CC was negative or faintly positive signal on fs-T1WI, bright signal on UTE MRI and the contrast remained even higher on the UTE subtraction, which reflected their short T2 values. Median CNRs and standard errors of the segments on each imaging were as follows: on fs-T1WI, -10.2 ± 4.2 for CC, 149.7 ± 27.6 for BC and 37.9 ± 14.3 for CO; on UTE MRI first echo, 16.7 ± 3.3 for CC, 74.9 ± 21.3 for BC and 17.7 ± 8.4 for CO; on UTE subtraction image, 30.2 ±2.0 for CC, -11.2 ± 5.4 for BC and 17.8 ± 10.7 for CO. Linear correlations between CNRs and cholesterol concentrations were observed on fs-T1WI with r = -0.885, (P < 0.0001), UTE MRI first echo r = -0.524 (P = 0.0072) and UTE subtraction with r = 0.598 (P = 0.0016). CONCLUSION: UTE MRI and UTE subtraction can depict CC bright.


Asunto(s)
Cálculos Biliares , Colesterol , Cálculos Biliares/diagnóstico por imagen , Humanos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Imagen por Resonancia Magnética , Estudios Retrospectivos
2.
Magn Reson Med Sci ; 18(4): 265-271, 2019 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-30828045

RESUMEN

PURPOSE: The accuracy of flow velocity and three-directional velocity components are important for the precise visualization of hemodynamics by 3D cine phase-contrast MRI (3D cine PC MRI, also referred to as 4D-flow). The aim of this study was to verify the accuracy of these measurements of prototype or commercially available 3D cine PC MRI obtained by three different manufactures' MR scanners. METHODS: The verification of the accuracy of flow velocity in 3D cine PC MRI was performed by circulating blood mimicking fluid through a straight-tube phantom in a slanting position, such that the three-directional velocity components were simultaneously measurable, using three 3T MR scanners from different manufacturers. The data obtained were processed by phase correction, and the velocity and three-directional velocity components in the center of the tube on the central cross section of a slab were calculated. The velocity profile in each three directions and the composite velocity profiles were compared with the calculated reference values, using the Hagen-Poiseuille equation. In addition, velocity profiles and the spatially time-averaged velocity perpendicular to the tube were compared with the theoretical values and measured values by a flowmeter, respectively. RESULTS: An underestimation of the maximum velocity in the center of the tube and an overestimation of the velocity near the tube wall due to partial volume effects were observed in all three scanners. A roughening and flattening of profiles in the center of the tube were observed in one scanner, due, presumably, to the low signal-to-noise ratio. However, the spatially time-averaged velocities corresponded well with the measured values by the flowmeter in all three scanners. CONCLUSION: In this study, we have demonstrated that the accuracy of flow velocity and three-directional velocity components in 3D cine PC MRI was satisfactory in all three MR scanners.


Asunto(s)
Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética , Imagen por Resonancia Cinemagnética/instrumentación , Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Cinemagnética/normas , Fantasmas de Imagen
3.
Magn Reson Med Sci ; 15(3): 288-98, 2016 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-26726016

RESUMEN

PURPOSE: We present a sequence for T1 relaxation-time mapping that enables a rapid and accurate measuring. The sequence is based on the Look-Locker method by employing turbo-field echo-planar imaging (TFEPI) acquisitions and time to free relaxation after constant application of the radiofrequency (RF) pulses. We optimized the sequence, and then evaluated the accuracy of the method in imaging of head and neck. MATERIALS AND METHODS: The method was implemented on a standard clinical scanner, and the accuracy of the T1 value was evaluated against that with the two-dimensional (2D) inversion recovery method. RESULTS: The percentage errors of the T1 value, as validated by phantom imaging measurements, were 3.1% for slow-relaxing compartments (T1 = 2736 msec) and 1.1% for fast-relaxing compartments (T1 = 264.2 msec). CONCLUSION: We demonstrated a fast 3D sequence to obtain multiple slices, based on the Look-Locker method for T1 measurement, which provided a rapid and accurate way of measuring the spin-lattice relaxation time. An acquisition time of approximately 5 min was achieved for T1 mapping; in principle, this can provide head and neck coverage with 15 slices.


Asunto(s)
Imagen Eco-Planar/instrumentación , Imagen Eco-Planar/métodos , Cabeza/diagnóstico por imagen , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Cuello/diagnóstico por imagen , Humanos , Modelos Teóricos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...