Int J Cardiovasc Imaging ; 38(10): 2219-2225, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37726459

RESUMEN

To investigate the usefulness of high-resolution systolic T1 mapping using compressed sensing for right ventricular (RV) evaluation. Phantoms and normal volunteers were scanned at 3 T by using a high-resolution (HR) modified look-locker inversion recovery (MOLLI) pulse sequence and a conventional MOLLI pulse sequence. The T1 values of the left ventricular (LV) and RV myocardium and blood pool were measured for each sequence. T1 values of HR-MOLLI and MOLLI sequences were compared in the LV myocardium, blood pool, and RV myocardium. The T1 values of HR-MOLLI and MOLLI showed good agreement in both phantoms and the LV myocardium and blood pool of volunteers. However, there was a significant difference between HR-MOLLI and MOLLI in the RV myocardium (1258 ± 52 ms vs. 1327 ± 73 ms; P = 0.0005). No significant difference was observed between the T1 value of RV and that of LV (1217 ± 32 ms) in HR-MOLLI, whereas the T1 value of RV was significantly higher than that of LV in MOLLI (P < 0.0001). The interclass correlation coefficients of intraobserver variabilities from HR-MOLLI and MOLLI were 0.919 and 0.804, respectively, and the interobserver variabilities from HR-MOLLI and MOLLI were 0.838 and 0.848, respectively. Assessment of RV myocardium by using HR systolic T1 mapping was superior to the conventional MOLLI sequence in terms of accuracy and reproducibility.


Asunto(s)
Ventrículos Cardíacos , Voluntarios , Humanos , Ventrículos Cardíacos/diagnóstico por imagen , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Fantasmas de Imagen
2.
Magn Reson Imaging ; 76: 87-95, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33232768

RESUMEN

PURPOSE: Multi-spin echo acquisition cine imaging (MUSACI) is a method used for cerebrospinal fluid (CSF) dynamics imaging based on the proton phase dispersion and flow void using 3D multi-spin echo imaging. In a previous study, the refocusing flip angle of MUSACI was set at a constant 80°. We conducted the present study to investigate the preservation the CSF signal intensity even in a long echo train and improve the ability to visualize CSF movement by modifying the refocusing flip angle in MUSACI. METHODS: The MUSACI images were acquired in 10 healthy volunteers (7 men and 3 women; age range 24-44 years; mean age 29.4 ±â€¯6.2 years) with a 3.0 Tesla MR scanner. Five refocusing flip angle sets were applied: constant 30°, constant 50°, constant 80°, pseudo-steady state (PSS) 50°-70°-100° (PSS50°), and PSS80°-100°-130° (PSS80°). In all sequences, the in-plane spatial resolution was 0.58 × 0.58 mm2, and the CSF movement for one heartbeat was drawn at 80-msec intervals. The signal intensity (SI) of CSF in the lateral ventricle, the foramen of Monro, the third ventricle, the fourth ventricle, and the pons was measured on MUSACI. Pearson's correlation coefficient was calculated between the CSF SI and effective echo time (TE; TEeff) in the lateral ventricle. RESULTS: Both antegrade and retrograde CSF movements on the midsagittal MUSACI images and the retrograde CSF movement in the foramen of Monro was observed in all sequences with the constant flip angles. A strong reverse correlation between the CSF SI in the lateral ventricle and TEeff values was observed with constant 30° (r = -0.96, p < 0.01), constant 50° (r = -0.97, p < 0.01) and constant 80° (r = -0.88, p < 0.01). A weak positive correlation was observed with PSS50° (r = 0.28, p = 0.43), and a moderate reverse correlation was observed at PSS80° (r = -0.60, p = 0.07). The SI values of the foramen of Monro, the third ventricle, and the fourth ventricle were significantly lower than that of the lateral ventricle, and those values were higher than that of the pons in both the constant 80° sequence and the PSS 50° sequence. CONCLUSION: PSS50° could be the optimal flip angle scheme for MUSACI, because the SI changes due to CSF movement and the SI preservation due to a long echo train were large due to the use of the refocusing flip angle method.


Asunto(s)
Líquido Cefalorraquídeo/diagnóstico por imagen , Líquido Cefalorraquídeo/fisiología , Hidrodinámica , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Adulto Joven
3.
Eur Heart J Cardiovasc Imaging ; 21(8): 855-862, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32359071

RESUMEN

AIMS: Right atrial (RA) function largely contributes to the maintenance of right ventricular (RV) function. This study investigated the effect of balloon pulmonary angioplasty (BPA) on RA functions in patients with inoperable chronic thromboembolic pulmonary hypertension (CTEPH) using cardiac magnetic resonance imaging (CMRI). METHODS AND RESULTS: CMRI and RV catheterization were performed before BPA sessions and at the follow-up periods in 29 CTEPH patients. Reservoir [RA longitudinal strain (RA-LS)], passive conduit [RA early LS rate (LSR)], and active (RA late LSR) phases were assessed by using cine CMRI and a feature-tracking algorithm. The relationships between the changes in RA functions and in brain natriuretic peptide (BNP) were evaluated in both the dilated and non-dilated RA groups. RA-LS (32.4% vs. 42.7%), RA LSR (6.3% vs. 8.3%), and RA early LSR (-2.3% vs. -4.3%) were improved after BPA, whereas no significant change was seen in RA late LSR. The changes in RA peak LS and in RA early LSR were significantly correlated with the changes in BNP (ΔRA-LS: r = -0.63, ΔRA-early LSR: r = 0.65) and pulmonary vascular resistance (PVR) (ΔRA-LS: r = -0.69, ΔRA-early LSR: r = 0.66) in the nondilated RA group. CONCLUSION: The RA reservoir and passive conduit functions were impaired in inoperable CTEPH, whereas RA active function was preserved. BPA markedly reversed these impaired functions. The improvements in RA reservoir and conduit functions were significantly correlated with the changes in BNP levels and PVR in CTEPH patients with normal RA sizes.


Asunto(s)
Angioplastia de Balón , Hipertensión Pulmonar , Embolia Pulmonar , Enfermedad Crónica , Humanos , Hipertensión Pulmonar/diagnóstico por imagen , Hipertensión Pulmonar/terapia , Arteria Pulmonar , Embolia Pulmonar/complicaciones , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/terapia , Resistencia Vascular , Función Ventricular Derecha
4.
Magn Reson Med ; 81(1): 331-341, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30194785

RESUMEN

PURPOSE: To evaluate the visualization of CSF dynamics using the novel method multi-spin echo acquisition cine imaging (MUSACI). METHODS: MUSACI is based on multi-echo volume isotropic turbo spin-echo acquisition (VISTA) with pulse gating. MUSACI images were acquired in 11 healthy volunteers (7 men, 4 women; age range, 24-46 y, mean age, 31.9 ± 5.51 y). We compared the CSF signal intensities (SIs) at multiple values of the effective echo time (TEeff ) at the lateral ventricle, the foramen of Monro, the third ventricle, and the fourth ventricle. We compared the CSF SI changes in MUSACI at multiple TEeff and the mean velocities in phase contrast (PC) at each trigger delay at the foramen of Monro, the third ventricle, and the fourth ventricle. RESULTS: The anterograde CSF motion from the aqueduct to the fourth ventricle, the retrograde motion from the aqueduct to the third ventricle, and the retrograde motion from the foramen of Monro to the lateral ventricle were observed with MUSACI. The CSF SIs at each TEeff in the foramen of Monro, the third ventricle, and the fourth ventricle were significantly lower than that at each TEeff in the lateral ventricle (P < 0.05). The CSF SI in MUSACI changed with the TEeff , and the CSF movements were observed at each trigger delay in PC. CONCLUSION: MUSACI can provide both high-resolution anatomical detail of the CSF passageways and physiologic information regarding CSF dynamics in a single scan.


Asunto(s)
Ventrículos Cerebrales/diagnóstico por imagen , Líquido Cefalorraquídeo/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Imagen por Resonancia Magnética , Adulto , Líquido Cefalorraquídeo/fisiología , Femenino , Voluntarios Sanos , Humanos , Hidrocefalia/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Movimiento (Física) , Fantasmas de Imagen
5.
J Magn Reson Imaging ; 45(3): 863-871, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27439061

RESUMEN

PURPOSE: To evaluate the dependence of saturation pulse power and duration on glycosaminoglycan chemical exchange saturation transfer (gagCEST) imaging and assess the degeneration of human lumbar intervertebral discs (IVDs) using this method. MATERIALS AND METHODS: All images were acquired on a 3T magnetic resonance imaging (MRI) scanner. The CEST effects were measured in the glycosaminoglycan (GAG) phantoms with different concentrations. In the human study, CEST effects were measured in the nucleus pulposus of IVD. We compared the CEST effects among the different saturation pulse powers (0.4, 0.8, and 1.6 µT) or durations (0.5, 1.0, and 2.0 sec) at each Pfirrmann grade (I-V). The relationship between the CEST effects and low back pain was also evaluated. RESULTS: The phantom study showed high correlations between the CEST effects and GAG concentration (R2 = 0.863, P < 0.0001, linear regression). In the human study, the CEST effect obtained with the 0.8 µT power was significantly greater than those obtained with 0.4 (P < 0.01) and 1.6 µT power (P < 0.05) at Pfirrmann grade I. The CEST effect obtained with a 1.0-sec duration was significantly greater than those derived with 0.5 and 2.0 sec (P < 0.01) durations at Pfirrmann grades I and II. The CEST effects in the group with moderate low back pain were significantly lower than those in the groups without pain (P < 0.001) and with mild pain (P = 0.0216). CONCLUSION: The contrast of gagCEST imaging in the lumbar IVDs varied with saturation pulse power and duration. GagCEST imaging may serve as a tool for evaluating IVD degeneration in the lumbar spine. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:863-871.


Asunto(s)
Glicosaminoglicanos/metabolismo , Degeneración del Disco Intervertebral/diagnóstico por imagen , Degeneración del Disco Intervertebral/metabolismo , Dolor de la Región Lumbar/diagnóstico por imagen , Dolor de la Región Lumbar/metabolismo , Imagen por Resonancia Magnética/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Biomarcadores/metabolismo , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Degeneración del Disco Intervertebral/complicaciones , Dolor de la Región Lumbar/etiología , Masculino , Imagen Molecular/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
Opt Lett ; 38(12): 2044-6, 2013 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-23938971

RESUMEN

We have developed a compact integral three-dimensional (3D) imaging equipment that positions the lens array and image sensor in close proximity to each other. In the conventional scheme, a camera lens is used to project the elemental images generated by the lens array onto the image sensor. In contrast, the imaging equipment presented here combines the lens array and image sensor into one unit and makes no use of a camera lens. This scheme eliminates the resolution deterioration and distortion caused by the use of a camera lens and improves, in principle, the quality of the reconstructed 3D image. We captured objects with this imaging equipment and displayed the reconstructed 3D images using display equipment consisting of a liquid crystal panel and a lens array. The reconstructed 3D images were found to have appropriate motion parallax.