Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
2.
Int J Cardiol ; 167(4): 1317-21, 2013 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-22578951

RESUMEN

BACKGROUND: Patients with cyanotic congenital heart disease(CCHD) have haemostatic abnormalities, which result in an increased risk of bleeding. The cause is unknown, but recent studies have indicated that an elevated haematocrit, which is present in cyanotic patients, could be an important factor. The aim of this study was to characterize the haemostatic profile, examine how changes in haematocrit affect the haemostatic profile, and whether a haematocrit reduction could terminate bleeding in CCHD patients. METHODS: This was a prospective, multicenter study. The haemostatic profile consisting of haematocrit, platelet count and thrombelastography(TEG) was characterized in ninety-eight CCHD patients. To evaluate the influence of haematocrit on the haemostatic profile, 21 of the patients underwent phlebotomy and 16 patients received treatment with an iron supplement. Furthermore ten patients with haemoptysis underwent phlebotomy. The haemostatic profile was reevaluated after interventions. RESULTS: TEG revealed that patients with CCHD and elevated haematocrit were hypocoagulable due to reduced clot formation and strength. Furthermore a positive correlation between elevated haematocrit and hypocoagulability was present. Interventions such as phlebotomy and treatment with supplemental iron causing significant haematocrit changes confirmed the correlation between haematocrit and the haemostatic profile. Finally a haematocrit reduction by phlebotomy successfully terminated haemoptysis in ten CCHD patients. CONCLUSION: Patients with CCHD and elevated haematocrit are hypocoagulable. The hypocoagulable haemostatic profile is positively correlated to increasing haematocrit. An intervention, which increases or decreases haematocrit, changes the haemostatic profile. A haematocrit reduction seems to improve the haemostatic profile, and may thereby terminate bleeding. However, these results warrant further studies.


Asunto(s)
Cianosis/sangre , Cianosis/diagnóstico , Cardiopatías Congénitas/sangre , Cardiopatías Congénitas/diagnóstico , Hemostasis/fisiología , Adulto , Cianosis/epidemiología , Femenino , Cardiopatías Congénitas/epidemiología , Hematócrito/métodos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tromboelastografía/métodos
3.
Int J Cardiol ; 167(5): 2210-4, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-22727966

RESUMEN

BACKGROUND: Patients with cyanotic congenital heart disease (CCHD) have haemostatic abnormities associated with bleeding and thrombo-embolic events. The haemostatic abnormalities are not fully understood, but recent studies indicate that elevated haematocrit and fibrinogen function may be of importance. The aim of this study was to characterise the haemostatic profile and examine the potential role of haematocrit on clot formation and strength in CCHD patients. Furthermore to examine whether CCHD patients with history of haemoptysis have diminished fibrinogen function compared to those without haemoptysis. METHODS: In a prospective study 75 adult CCHD patients had haematocrit, platelet count, and plasma fibrinogen concentration examined. Furthermore thrombelastography(TEG) as well as TEG Functional Fibrinogen(TEG FF) assay evaluating fibrinogen function(FLEV) was performed. Data were compared with historical data regarding previous haemoptysis in CCHD patients. RESULTS: Haematocrit was 57 ± 8% and platelet counts in the lower normal range. TEG revealed a hypocoagulable condition with impaired clot formation. TEG values were correlated to haematocrit, indicating that elevated haematocrit causes impaired clot formation and strength. Despite high levels of plasma fibrinogen, TEG FF demonstrated that FLEV was diminished and negatively correlated to haematocrit. Furthermore CCHD patients with previous history of haemoptysis had significantly lower FLEV compared to CCHD patients without haemoptysis. CONCLUSION: Patients with CCHD are hypocoagulable mainly due to impaired fibrinogen function. Despite a low platelet count, platelet function does not seem to be severely affected in CCHD patients. Haemostasis, and especially fibrinogen function, is negatively affected by elevated haematocrit, and fibrinogen function is diminished in CCHD patients with haemoptysis.


Asunto(s)
Fibrinógeno/fisiología , Cardiopatías Congénitas/sangre , Cardiopatías Congénitas/diagnóstico , Hemostasis/fisiología , Adulto , Cianosis , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recuento de Plaquetas/métodos , Estudios Prospectivos , Tromboelastografía/métodos , Tiempo de Coagulación de la Sangre Total/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA