1.
Indian Pacing Electrophysiol J ; 24(2): 68-74, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38096986

RESUMEN

INTRODUCTION: During radiofrequency (RF) ablation, impedance monitoring has been used to avoid steam-pop caused by excessive intramyocardial temperature (IMT) rise. However, it is uncertain why the impedance decline is related to steam-pop and whether the impedance decline is correlated to IMT. METHODS: Twenty-one bipolar ablations (40 W, 30-g contact, 120 s) were attempted for seven perfused porcine myocardium. Immediately after ablation, a temperature electrode was inserted into the mid-myocardial portion, and the recovery process of impedance and its correlation to IMT were assessed. RESULTS: Transmural lesion was created in all 21 applications but steam-pop occurred in 5/21 applications with large impedance decline. In the 16 applications without steam-pop, impedance and IMT soon after ablation were 97.2 ± 4.0 Ω and 66.1 ± 4.8 °C, respectively. Reasonably high linear correlation was demonstrated between the maximum IMT after ablation and impedance differences before and after ablation. Recovery processes of the decreased impedance and the elevated IMT fit well to each equation of the single exponential decay function and showed symmetric shapes with no statistical difference of time constant (100.1 ± 34.5 s in impedance vs. 108.7 ± 27.3 s in IMT) and half-time of recovery (144.5 ± 49.8 s in impedance vs. 156.9 ± 39.4 s in IMT). Recovered impedance after ablation (104.8 ± 3.9 Ω) was 5.1 ± 2.0 Ω smaller than that before ablation (109.9 ± 2.7 Ω), suggesting several factors other than IMT rise participate in impedance decline in RF ablation. CONCLUSIONS: Recovery of impedance and IMT after ablation well correlated, which supports the usefulness of impedance monitoring for safe RF ablation.

2.
J Cardiovasc Electrophysiol ; 33(12): 2538-2545, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36135613

RESUMEN

INTRODUCTION: Bipolar (BIP) radiofrequency (RF) ablation creates deep myocardial lesions but ideal energy application modes to treat ventricular arrhythmias originating from deep inside the thick myocardium have not been well established. An experimental study was performed to clarify whether high power and long application time BIP ablation were performable by impedance-decline-guide power control (PC) and whether it could create transmural lesions in the thick ventricle with a minimum risk of steam-pop. METHODS AND RESULTS: Perfused porcine ventricle (18.4 ± 2.3 mm) was placed in an experimental bath and BIP ablation (50 W) for 120 s was attempted with catheter contact of 30-g using two protocols; fixed power (FP) and impedance-decline-guide PC. In the latter protocol, BIP ablation was started from 50 W, while the energy was decreased to 40-20 W according to the impedance decline during RF ablation. FP ablation was attempted in 30 applications and the transmural lesion was created in all 30, although steam-pop occurred in 16/30 applications (53%). Low minimum impedance, large total impedance decline (TID), and %-TID were associated with the steam-pop occurrence. PC ablation was attempted in another 21 applications, and the transmural lesion was created in all 21 without steam-pop. PC ablation was superior to FP ablation (21/21 vs. 14/30, p < .001) in the creation of a transmural lesion without resulting in steam-pop. CONCLUSIONS: High power and long application time BIP ablation seems to be feasible according to the impedance-decline-guide approach, which could create transmural lesions in thick porcine ventricles with minimal risk of steam-pop.


Asunto(s)
Ablación por Catéter , Vapor , Porcinos , Animales , Impedancia Eléctrica , Irrigación Terapéutica/métodos , Modelos Animales , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Diseño de Equipo
3.
J Arrhythm ; 37(4): 1038-1045, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34386130

RESUMEN

BACKGROUND: Anti-tachycardia pacing (ATP) delivered from an implantable device is a useful tool to terminate ventricular tachycardia (VT). But its real-world efficacy for those patients having multiple VTs with varying VT rates has not been fully studied. METHODS: Using the Nippon-storm study database, efficacy of patient-by-patient basis ATP programing for Japanese patients having both non-fast (120-187 bpm) and fast VT (≥188 bpm) was assessed. According to the useful criteria of ≥50% success termination by ATP, patients were divided into three subgroups; success ≥50% for both non-fast and fast VT (both useful), ≥50% only for non-fast VT (non-fast VT useful), or ≥50% for neither non-fast nor fast VT (neither useful). RESULTS: During a median follow-up of 28 months, ATP terminated 184 of the 203 non-fast VT episodes (91%) and 86 of the 113 fast VT episodes (76%) in all 41 patients. In the patient-by-patient analysis, efficacy of ATP was not different between non-fast and fast VT in most of the patients (36/41 = 88%); 32 patients were in the both useful and four other patients in the neither useful. Neither ischemic nor non-ischemic structural heart disease was associated with the ATP efficacy, whereas LVEF more than 37.0% and non-prescribed amiodarone were characteristics of the patients classified into the both useful. CONCLUSIONS: ATP well terminated both non-fast and fast VT occurring in individual Japanese patients with various structural heart diseases in the real-world device treatment and this finding further supports ATP programing for all device tachycardia detection zones in most patients with multiple VTs.

4.
Pacing Clin Electrophysiol ; 43(9): 983-991, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32524624

RESUMEN

BACKGROUND: Anti-tachycardia pacing (ATP) delivered from an implantable device is an important tool to terminate ventricular tachycardia (VT). But its real-world efficacy for fast VT has not been fully studied. METHODS: Using the database of Nippon-storm study, effect of patient-by-patient basis ATP programming for fast VT (≥188 bpm) was assessed for the patients with structural heart diseases. Fast VTs were divided into three groups depending on heart rate (HR); Group A was 188-209 bpm, and Group-B and Group-C were 210-239 bpm and ≥240 bpm, respectively. RESULTS: During a median follow-up of 28 months, 202 fast VT episodes (209 ± 19 bpm) were demonstrated in the 85 patients. ATP terminated 151 of the 202 episodes (74.8%) in total. The success rate of the ATP was not different among the three groups: 73.3% in Group A, 80.6% in Group B, and 66.7% in Group C. ATP success rate of >50% and >70% was 77.6% and 64.7% of the patients, respectively. Left ventricular ejection fraction (LVEF) was significantly higher in the patients with rather than without successful ATP therapy, and receiver operating characteristic (ROC) analysis revealed that LVEF of 23% was the optimal cut-off value. ATP was less effective in patients taking amiodarone, but etiology of the structural heart diseases, indication of the device implantation, and all Electrocardiogram (ECG) parameters were not useful predictors for successful ATP therapy. CONCLUSIONS: ATP highly terminated fast VT with wide HR ranges in patients with structural heart diseases, and should be considered as the first-line therapy for fast VT except for patients with very low LVEF.


Asunto(s)
Cardioversión Eléctrica/instrumentación , Cardiopatías/complicaciones , Taquicardia Ventricular/prevención & control , Anciano , Estimulación Cardíaca Artificial , Desfibriladores Implantables , Electrocardiografía , Femenino , Humanos , Japón , Masculino , Taquicardia Ventricular/fisiopatología
5.
Heart Rhythm ; 17(1): 133-141, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31369871

RESUMEN

BACKGROUND: Renal artery catheter ablation has been reported as a possible therapeutic option for drug-refractory ventricular arrhythmias (VAs) associated with structural heart diseases. OBJECTIVE: To further clarify its therapeutic background, we examined the relationship between electrical nerve stimulation (ENS)-induced blood pressure (BP) elevation and occurrence of VAs by using an acute canine model of renal artery ablation. METHODS: Using a decapolar electrode catheter, ENS was successively applied from the distal, mid, and proximal segments of the renal artery in 8 beagles. The same ENS was repeated after accomplishment of radiofrequency ablation at the ostial site of the renal artery by using an irrigation catheter. RESULTS: Before ablation, ENS increased BP from 140 ± 11/77 ± 11 to 167 ± 20/98 ± 16 mm Hg and heart rate from 100 ± 21 to 131±33 beats/min as well as induced VAs in 20 of the 45 ENS applications. Occurrence of VAs was associated with a greater magnitude of sympathetic nerve augmentation, and VAs were more frequently observed by ENS at the distal (67%) rather than mid/proximal segments of the renal artery (33%). Renal artery ablation was accomplished without any angiographic stenosis, and ENS-induced BP elevation, heart rate acceleration, and VAs occurrence were attenuated not only at the close segment (proximal) but also at the remote segments (mid/distal) of the renal artery. CONCLUSION: The renal autonomic nerves are considered as one of the therapeutic targets for suppression of frequent VAs because its activation has arrhythmogenic potential and induces premature ventricular beats.


Asunto(s)
Vías Autónomas/fisiopatología , Ablación por Catéter/métodos , Estimulación Eléctrica/métodos , Sistema de Conducción Cardíaco/cirugía , Arteria Renal/cirugía , Taquicardia Ventricular/cirugía , Animales , Modelos Animales de Enfermedad , Perros , Sistema de Conducción Cardíaco/fisiopatología , Taquicardia Ventricular/fisiopatología
6.
Int Heart J ; 60(5): 1161-1167, 2019 Sep 27.
Artículo en Inglés | MEDLINE | ID: mdl-31484866

RESUMEN

Therapy-resistant ventricular arrhythmias can occur during accidental advanced hypothermic conditions. On the other hand, hypothermic therapy using mild cooling has been successfully accomplished with infrequent ventricular arrhythmia events.To further clarify the therapeutic-resistant arrhythmogenic substrate which develops in hypothermic conditions, an experimental study was performed using a perfusion wedge preparation model of porcine ventricle, and electrophysiological characteristics, inducibility of ventricular arrhythmias, and effects of therapeutic interventions were assessed at 3 target temperatures (37, 32 and 28°C).As the myocardial temperature decreased, myocardial contractions and the number of spontaneous beats deceased. Depolarization (QRS width, stimulus-QRS interval) and repolarization (QT interval, ERP) parameters progressively increased, and dispersion of the ventricular repolarization increased. At 28°C, VF tended to be inducible more frequently (1/11 at 37°C, 1/11 at 32°C, and 5/11 hearts at 28°C), and some VFs at 28°C required greater defibrillation energy to resume basic rhythm.An advanced but not a mild hypothermic condition had an enhanced arrhythmogenic potential in our model. In the advanced hypothermic condition, VF with relatively prolonged F-F intervals and a greater defibrillation energy were occasionally inducible based on the arrhythmogenic substrate characterized as slowed conduction and prolonged repolarization of the ventricle.


Asunto(s)
Antiarrítmicos/administración & dosificación , Electrocardiografía/métodos , Hipotermia Inducida/métodos , Fibrilación Ventricular/diagnóstico por imagen , Fibrilación Ventricular/terapia , Análisis de Varianza , Animales , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Electrofisiología Cardíaca/métodos , Modelos Animales de Enfermedad , Resistencia a Medicamentos , Distribución Aleatoria , Medición de Riesgo , Porcinos , Resultado del Tratamiento
7.
J Arrhythm ; 34(2): 139-147, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29657589

RESUMEN

Background: Whether nonsustained ventricular tachycardia (NSVT) is a marker of increased risk of sustained ventricular tachyarrhythmias (VTAs) remains to be established in patients receiving cardiac resynchronization therapy with a defibrillator (CRT-D) for primary prevention. Methods: Among the follow-up data of the Japan cardiac device treatment registry (JCDTR) with an implantation date between January 2011 and August 2015, information regarding a history of NSVT before the CRT-D implantation for primary prevention had been registered in 269 patients. Outcomes were compared between two groups with and without NSVT: NSVT group (n = 179) and No NSVT group (n = 90). Results: There was no significant difference with regard to age, gender, and NYHA class between the two groups. Left ventricular ejection fraction (LVEF) was 25.6% in the NSVT group and 28.0% in the No NSVT group (P = .046). The rate of appropriate therapy at 24 months was 26.0% and 18.4% in the NSVT and No NSVT groups (P = .22), respectively. Survival free from heart failure death was reduced in the NSVT group, as compared with the No NSVT group, with the rate of 90.2% vs 97.2% at 24 months (P = .030). A multivariate analysis identified a history of NSVT, anemia, and no use of angiotensin-converting enzyme inhibitor (ACEI) or angiotensin-receptor blocker (ARB) as predictors of heart failure death. Conclusions: NSVT appears to be a surrogate marker of severe heart failure rather than a substrate for subsequent sustained VTAs in patients with CRT-D for primary prevention.

8.
Int J Cardiol ; 255: 85-91, 2018 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-29425569

RESUMEN

BACKGROUND: Electrical storm (E-Storm), defined as multiple episodes of ventricular arrhythmias within a short period of time, is an important clinical problem in patients with an implantable cardiac defibrillator (ICD) including cardiac resynchronization therapy devices capable of defibrillation. The detailed clinical aspects of E-Storm in large populations especially for non-ischemic dilated cardiomyopathy (DCM), however, remain unclear. OBJECTIVE: This study was performed to elucidate the detailed clinical aspects of E-Storm, such as its predictors and prevalence among patients with structural heart disease including DCM. METHODS: We analyzed the data of the Nippon Storm Study, which was a prospective observational study involving 1570 patients enrolled from 48 ICD centers. For the purpose of this study, we evaluated 1274 patients with structural heart disease, including 482 (38%) patients with ischemic heart disease (IHD) and 342 (27%) patients with DCM. RESULTS: During a median follow-up of 28months (interquartile range: 23 to 33months), E-Storm occurred in 84 (6.6%) patients. The incidence of E-Storm was not significantly different between patients with IHD and patients with DCM (log-rank p=0.52). Proportional hazard regression analyses showed that ICD implantation for secondary prevention of sudden cardiac death (p=0.0001) and QRS width (p=0.015) were the independent risk factors for E-storm. In a comparison between patients with and without E-Storm, survival curves after adjustment for clinical characteristics showed a significant difference in mortality. CONCLUSION: E-Storm was associated with subsequent mortality in patients with structural heart disease including DCM.


Asunto(s)
Terapia de Resincronización Cardíaca/mortalidad , Cardiomiopatías/mortalidad , Cardiomiopatías/terapia , Desfibriladores Implantables , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/terapia , Anciano , Terapia de Resincronización Cardíaca/tendencias , Cardiomiopatías/fisiopatología , Desfibriladores Implantables/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Mortalidad/tendencias , Estudios Prospectivos , Sistema de Registros , Fibrilación Ventricular/fisiopatología
9.
Circ J ; 81(12): 1798-1806, 2017 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-28626201

RESUMEN

BACKGROUND: Randomized control trials comparing the effectiveness of cardiac resynchronization therapy devices, with (CRT-D) or without (CRT-P) a defibrillator, are scarce in heart failure patients with no prior sustained ventricular tachyarrhythmias.Methods and Results:The Japan Cardiac Device Treatment Registry (JCDTR) has data for 2714 CRT-D and 555 CRT-P recipients for primary prevention with an implantation date between January 2011 and August 2015. Of these patients, follow-up data were available for 717. Over the mean follow-up period of 21 months, Kaplan-Meier curves of survival free of combined events for all-cause death or heart failure hospitalization (whichever came first) diverged between the CRT-D (n=620) and CRT-P (n=97) groups with a rate of 22% vs. 42%, respectively, at 24 months (P=0.0011). However, this apparent benefit of CRT-D over CRT-P was no longer significant after adjustment for covariates. With regard to mortality, including heart failure death or sudden cardiac death, there was no significant difference between the 2 groups. CONCLUSIONS: In patients without sustained ventricular tachyarrhythmias enrolled in the JCDTR, there was no significant difference in mortality between the CRT-D and CRT-P groups, despite a lower trend in CRT-D recipients. This study was limited by large clinical and demographic differences between the 2 groups.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Desfibriladores Implantables , Insuficiencia Cardíaca/terapia , Hospitalización , Anciano , Anciano de 80 o más Años , Femenino , Insuficiencia Cardíaca/mortalidad , Humanos , Japón , Masculino , Persona de Mediana Edad , Prevención Primaria , Sistema de Registros , Análisis de Supervivencia
10.
J Electrocardiol ; 50(3): 277-281, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28238302

RESUMEN

BACKGROUND: Patients with repetitive ventricular tachyarrhythmias - so-called electrical storm - frequently require antiarrhythmic drugs. Amiodarone is widely used for the treatment of electrical storm but is ineffective in some patients. Therefore, we investigated the efficacy of stepwise administration of nifekalant, a pure potassium channel blocker, and mexiletine for electrical storm. METHODS: This study included 44 patients with repetitive ventricular tachyarrhythmias who received stepwise therapy with nifekalant and mexiletine for electrical storm. Nifekalant was initially administered, and mexiletine was subsequently added if nifekalant failed to control ventricular tachyarrhythmias. RESULTS: Nifekalant completely suppressed recurrences of ventricular arrhythmias in 28 patients (64%), including 6 patients in whom oral amiodarone failed to control arrhythmias. In 9 of 16 patients in whom nifekalant was partially effective but failed to suppress ventricular arrhythmias, mexiletine was added. The addition of mexiletine prevented recurrences of ventricular tachyarrhythmias in 5 of these 9 patients (56%). There was no death associated with electrical storm. In total, the stepwise treatment with nifekalant and mexiletine was effective in preventing ventricular tachyarrhythmias in 33 of 44 patients (75%). There was no difference in cycle length of the ventricular tachycardia, QRS interval, QT interval, or left ventricular ejection fraction between patients who responded to antiarrhythmic drugs and those who did not. During follow-up, 8 patients had repetitive ventricular tachyarrhythmia recurrences, and the stepwise treatment was effective in 6 of these 8 patients (75%). CONCLUSIONS: The stepwise treatment with nifekalant and mexiletine was highly effective in the suppression of electrical storm.


Asunto(s)
Electroencefalografía/efectos de los fármacos , Mexiletine/administración & dosificación , Bloqueadores de los Canales de Potasio/administración & dosificación , Pirimidinonas/administración & dosificación , Bloqueadores de los Canales de Sodio/administración & dosificación , Taquicardia Ventricular/tratamiento farmacológico , Taquicardia Ventricular/mortalidad , Administración Oral , Humanos , Japón/epidemiología , Prevalencia , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Taquicardia Ventricular/diagnóstico , Resultado del Tratamiento
11.
Pacing Clin Electrophysiol ; 40(3): 223-231, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27943352

RESUMEN

BACKGROUND: During bipolar (BIP) radiofrequency (RF) ablation using two catheters in humans, each catheter is placed in separate cardiac chambers or spaces. We developed a contact force-controlled experimental preparation, and compared measurements made with two catheters placed in a single bath (SB), versus each catheter placed in separate baths, in order to assess the preparation-dependent differences in the results of BIP-RF ablation. METHODS: In the SB experiments, a porcine heart was placed in the center of the bath, while in the dual-bath (DB) experiments, it was placed between two half baths communicating through windows. RESULTS: The initial impedance was greatest (110.5 ± 7.2 Ω) with the BIP-DB, followed by the BIP-SB (92.0 ± 5.6 Ω) and the unipolar (UNIP) DB (84.9 ± 4.7 Ω) configurations. During 50-W ablation for 60 seconds at a 20-g contact force, the root mean square voltage was 75.7 ± 2.5 V in the BIP-DB, 68.0 ± 2.1 V in the BIP-SB, and 66.8 ± 2.0 V in the UNIP-DB. The mean surface lesion diameters were similar among the three configurations. However, the endocardial lesion depth was 5.60 ± 0.56 mm with the BIP-DB, 4.71 ± 0.64 mm with the BIP-SB, and 4.24 ± 0.58 mm with the UNIP-DB configuration. On average, the endocardial lesions were significantly deeper than the epicardial ones. CONCLUSIONS: BIP ablation created much deeper lesions as compared to UNIP ablation. Lesion depth could be different depending on experimental preparation, and contact force-controlled DB preparation may be a much more appropriate model for studying the effects of BIP ablation.


Asunto(s)
Electrodos , Ventrículos Cardíacos/patología , Ventrículos Cardíacos/cirugía , Modelos Animales , Técnicas de Cultivo de Órganos/métodos , Cloruro de Sodio/química , Animales , Impedancia Eléctrica , Diseño de Equipo , Análisis de Falla de Equipo , Presión , Estrés Mecánico , Porcinos
12.
J Arrhythm ; 32(6): 486-490, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27920834

RESUMEN

BACKGROUND: The choice of cardiac resynchronization therapy device, with (CRT-D) or without (CRT-P) a defibrillator, in patients with heart failure largely depends on the physician׳s discretion, because it has not been established which subjects benefit most from a defibrillator. METHODS: We examined the annual trend of CRT device implantations between 2006 and 2014, and evaluated the factors related to the device selection (CRT-D or CRT-P) for primary prevention of sudden cardiac death in patients with heart failure by analyzing the Japan Cardiac Device Treatment Registry (JCDTR) database from January 2011 and August 2015 (CRT-D, n=2714; CRT-P, n=555). RESULTS: The proportion of CRT-D implantations for primary prevention among all the CRT-D recipients was more than 70% during the study period. The number of CRT-D implantations for primary prevention reached a maximum in 2011 and decreased gradually between 2011 and 2014, whereas CRT-P implantations increased year by year until 2011 and remained unchanged in recent years. Multivariate analysis identified age (odds ratio [OR] 0.92, 95% confidence interval [CI] 0.90-0.95, P<0.0001), male sex (OR 1.99, 95% CI 1.28-3.11, P<0.005), reduced left ventricular ejection fraction (LVEF) (OR 0.96, 95% CI 0.94-0.98, P<0.0001), and non-sustained ventricular tachycardia (NSVT) (OR 2.85, 95% CI 1.87-4.35, P<0.0001) as independent factors favoring the choice of CRT-D. CONCLUSIONS: Younger age, male sex, reduced LVEF, and a history of NSVT were independently associated with the choice of CRT-D for primary prevention of sudden cardiac death in patients with heart failure in Japan.

14.
Heart Rhythm ; 13(8): 1707-15, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27136698

RESUMEN

BACKGROUND: Catheter ablation of the renal artery can be performed without apparent angiographic stenosis. This suggests that renal nerve function can be attenuated with minor structural damage to the renal artery. OBJECTIVE: To clarify this hypothesis, we examined the relationship between electrical nerve stimulation (ENS)-induced blood pressure (BP) response and severity of histological injury of the renal artery using an acute canine model of renal artery ablation. METHODS: An irrigation catheter was inserted into the renal arteries of 8 dogs, and radiofrequency current was delivered at 15, 20, or 25 W. ENS was applied to each artery before and after ablation. RESULTS: Before ablation, ENS increased the BP and heart rate from 145 ± 15/86 ± 13 to 189 ± 21/111 ± 19 mm Hg and from 116 ± 9 to 130 ± 6 beats/min, respectively. Heart rate variability indices and serum catecholamine levels were elevated concomitantly. After ablation, the ENS-induced increase in BP and heart rate were markedly attenuated after 15 W ablation and those were nearly completely inhibited after 20 or 25 W ablation. An increase in heart rate variability indices and serum catecholamine levels became insignificant regardless of the applied energy. Renal artery angiograms revealed stenotic lesions only after 25 W ablation procedures. Histological studies showed mild to moderate injury of the arterial wall and autonomic nerves caused by 20 and 25 W ablation procedures, whereas only minor changes caused by 15 W ablation. CONCLUSION: Functional renal autonomic nerve ablation is potentially performable with the guidance of ENS.


Asunto(s)
Vías Autónomas/fisiopatología , Ablación por Catéter/métodos , Hipertensión/cirugía , Riñón/inervación , Arteria Renal/cirugía , Simpatectomía/métodos , Animales , Vías Autónomas/cirugía , Modelos Animales de Enfermedad , Perros , Estimulación Eléctrica , Hipertensión/fisiopatología , Riñón/irrigación sanguínea , Arteria Renal/inervación
15.
Intern Med ; 54(10): 1175-82, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25986253

RESUMEN

OBJECTIVE: The dominant frequency (DF) in frequency analyses is considered to represent the objective cycle length and complexity of activation under conditions of ventricular fibrillation (VF). However, knowledge regarding the mechanisms determining the DF in human VF is limited. We studied the characteristics of the DF of human VF and relationship between DF and the defibrillation threshold. METHODS: Seventy-two implantable cardioverter-defibrillator patients and 211 VF were studied. Using defibrillation tests, we performed a frequency analysis with fast Fourier transformation. The correlations between DF and clinical characteristics, including the defibrillation threshold, were assessed. RESULTS: The mean DF of all induced VFs was 5.2±0.8 Hz. The patients were divided into two groups according to DF: the low-DF (DF <5.2 Hz, n=32) and high-DF (DF ≥5.2 Hz, n=40) groups. The frequency of structural heart disease was significantly higher in the low-DF group. In addition, the QRS duration, QT interval and effective refractory period of the right ventricle (RV-ERP) were significantly longer in the low-DF group. A multivariate analysis showed RV-ERP to be the only independent predictor of DF. Excluding patients receiving group III anti-arrhythmic drugs, which are known to have potent defibrillation threshold effects, the defibrillation threshold was significantly lower in the low-DF group (p=0.026). CONCLUSION: We found that the DF of human VF is associated with underlying heart disease, the cardiac function, cardiac conduction, ventricular refractoriness and defibrillation threshold. Our findings may be useful for identifying and managing patients with a high defibrillation threshold.


Asunto(s)
Desfibriladores Implantables , Fibrilación Ventricular/fisiopatología , Fibrilación Ventricular/terapia , Adulto , Anciano , Antiarrítmicos/administración & dosificación , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Fibrilación Ventricular/tratamiento farmacológico , Adulto Joven
16.
Circ J ; 78(8): 1989-91, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25030300

RESUMEN

BACKGROUND: Little is known regarding the appropriate duration for driving restrictions after inappropriate implantable cardiac shock device (ICSD) therapy. METHODS AND RESULTS: We evaluated the Nippon Storm Study data, and found that inappropriate ICSD therapy occurred in 114 (7.6%) patients during a median follow-up of 464 days. Among those patients, 25 experienced further inappropriate ICSD therapy during a subsequent median follow-up of 380 days. Time-dependent recurrence of inappropriate ICSD therapy occurred in 19 (76%) patients within 180 days. CONCLUSIONS: The interval for driving restrictions after inappropriate ICSD therapy can be reduced.


Asunto(s)
Conducción de Automóvil , Tormentas Ciclónicas , Desfibriladores Implantables , Choque Cardiogénico/prevención & control , Anciano , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad
18.
Intern Med ; 52(11): 1189-93, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23728553

RESUMEN

In two patients treated with cardiac resynchronization therapy (CRT), left ventricular (LV) pacing failure occurred due to ring conductor fractures of the bipolar LV lead (co-radial model). CRT was resumed by pacing between the tip conductor of the LV lead and the coil conductor of the right ventricular lead. However, shortly thereafter, subsequent fracture of the tip conductor developed, and implantation of a new LV lead was required. When one of the bipolar conductors of a co-radial designed LV lead fractures, reimplantation of a new LV lead is a better therapeutic option (than changing the LV pacing mode) in order to reliably continue CRT treatment.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/efectos adversos , Análisis de Falla de Equipo/instrumentación , Falla de Equipo , Insuficiencia Cardíaca/diagnóstico por imagen , Anciano , Electrodos Implantados/efectos adversos , Análisis de Falla de Equipo/métodos , Femenino , Insuficiencia Cardíaca/terapia , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Resultado del Tratamiento
20.
Hypertension ; 61(2): 450-6, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23283361

RESUMEN

Radiofrequency (RF) catheter ablation of the renal artery is therapeutic in patients with drug-refractory essential hypertension. This study was designed to examine the role of the renal autonomic nerves and of RF application from inside the renal artery in the regulation of blood pressure (BP). An open irrigation catheter was inserted into either the left or right renal artery in 8 dogs. RF current (17 ± 2 watts) was delivered to one renal artery. Electrical autonomic nerve stimulation was applied to each renal artery before and after RF ablation. BP, heart rate, indices of heart rate variability, and serum catecholamines were analyzed. Before RF ablation, electrical autonomic nerve stimulation of either renal artery increased BP from 150 ± 16/92 ± 15 to 173 ± 21/105 ± 16 mm Hg. After RF ablation, BP increased similarly when the nonablated renal artery was electrically stimulated, although the rise in BP was attenuated when the ablated renal artery was stimulated. Serum catecholamines and sympathetic nerve indices of heart rate variability increased when electrical autonomic nerve stimulation was applied before RF ablation and to the nonablated renal artery after RF ablation, although it changed minimally when the ablated renal artery was stimulated, suggesting interconnectivity between afferent renal nerve stimulation and systemic sympathetic activity. Renal artery angiogram showed no apparent injury after RF ablation. In conclusion, electrical stimulation of the renal arterial autonomic nerves increases BP via an increase in central sympathetic nervous activity. This response might be used to determine the target ablation site and end point of renal artery RF ablation.


Asunto(s)
Sistema Nervioso Autónomo/fisiología , Presión Sanguínea/fisiología , Estimulación Eléctrica , Frecuencia Cardíaca/fisiología , Arteria Renal/inervación , Animales , Catecolaminas/sangre , Ablación por Catéter , Perros , Arteria Renal/cirugía
SELECCIÓN DE REFERENCIAS