Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Diabetes Sci Technol ; : 19322968231204376, 2023 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-37942633

RESUMEN

BACKGROUND: Evidence regarding the implementation of medium-term strategies in advanced hybrid closed-loop (AHCL) system users is limited. Therefore, this study aimed to describe the efficacy and safety of the AHCL system in patients with type 1 diabetes (T1D) on a six-month follow-up in a virtual diabetes clinic (VDC). METHOD: A prospective cohort of adult patients with T1D treated using the AHCL system (Mini Med 780G; Medtronic, Northridge, California) in a VDC follow-up. Standardized training and follow-up were conducted virtually. Clinical data and metabolic control outcomes were reported at baseline, and at three and six months. RESULTS: Sixty-four patients (mean age = 42 ± 14.6 years, 65% men, 54% with graduate education) were included. Percentage time in range (%TIR) increased significantly regardless of prior therapy with intermittently scanned continuous glucose monitoring + multiple daily injections and sensor-augmented pump therapy with predictive low-glucose management after starting AHCL and persisted during the follow-up period with no hypoglycemic events. The %TIR 70 to 180 mg/dL according to socioeconomic strata was 73.4% ± 5.3%, 78.1% ± 8.1%, and 84.2% ± 7.5% for the lower, middle, and upper strata, respectively. The sensor was used more frequently in the population with a higher education level. Adherence to sensor use and SmartGuard retention were higher in patients who underwent the VDC follow-up. CONCLUSIONS: Medium-term follow-up of users of AHCL systems in a VDC contributes to safely achieving %TIR goals. Virtual diabetes clinic follow-up favored adherence to sensor use and continuous SmartGuard use. Socioeconomic strata were associated with a better glycemic profile and education level was associated with better adherence to sensor use.

2.
Diabetes Res Clin Pract ; 204: 110897, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37678728

RESUMEN

AIMS: To describe Hybrid closed-loop (HCL) and advanced hybrid closed-loop (AHCL) performance in the hospital setting based on the continuous glucose monitoring (CGM) metrics description. METHODS: This was an observational study from a cohort of patients with T1D using HCL/AHCL with history of hospitalization. CGM metrics were analyzed during the hospital stay. CGM metrics sub-analysis of the population with active Automated Mode (AM) and SmartGuard (SG) during hospitalization and/or surgical procedure was performed. RESULTS: Twenty-four patients were included (50 % women; mean age, 49 years [inter-quartile range (IQR), 39-62 years]). During hospitalization 70.8 % patients achieved %Time in Range (TIR) between 70 and 180 mg/dL ≥ 70 %. The overall %TIR was 75.5 % (IQR, 67.3-81.5 %), % time below range (TBR) < 70 mg/dL was 2.1 % (IQR, 0.7-5.4 %) and %TBR < 54 mg/dL was 0 % (IQR, 0-5.4 %). Users of the AHCL with active SG achieved a non-significant higher %TIR during hospitalization (79 % [73.8.88 %] vs. 76 % [72.81 %], p = 0.312) and had a shorter stay (3[IQR, 2.4] vs. 6 days[IQR, 5.7], p = 0.045) compared to the users of the HCL with AM active. No device-related serious adverse events occurred for users of either system. CONCLUSIONS: HCL/AHCL systems with active AM/SG in patients with T1D in the hospital environment leads to %TIR > 70 % in ranges of 70-180 mg/dL in patients without increasing hypoglycemia.


Asunto(s)
Diabetes Mellitus Tipo 1 , Humanos , Femenino , Persona de Mediana Edad , Masculino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Glucemia , Automonitorización de la Glucosa Sanguínea , Control Glucémico , Hospitalización , Insulina , Hipoglucemiantes , Sistemas de Infusión de Insulina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...