Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
3.
Expert Rev Med Devices ; : 1-12, 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38655581

RESUMEN

INTRODUCTION: This systematic review and meta-analysis aimed to compare the efficacy of dynamic versus standard bougies to achieve tracheal intubation. METHODS: We searched MEDLINE, Embase, CENTRAL, Web of Science, Scopus and Google Scholar on 10 October 2023. We included clinical trials comparing both devices. The primary outcome was the first-attempt intubation success rate. The secondary outcome was the time required for tracheal intubation. RESULTS: Eighteen studies were included. Dynamic bougies do not increase first-attempt success rate (RR 1.11; p = 0.06) or shorten tracheal intubation time (MD -0.30 sec; p = 0.84) in clinical trials in humans. In difficult airways, first-attempt success intubation rate was greater for dynamic bougies (RR 1.17; p = 0.002); Additionally, they reduced the time required for intubation (MD -4.80 sec; p = 0.001). First-attempt intubation success rate was higher (RR 1.15; p = 0.01) and time to achieve intubation was shorter when using Macintosh blades combined with dynamic bougies (MD -5.38 sec; p < 0.00001). Heterogeneity was high. CONCLUSION: Dynamic bougies do not increase the overall first-pass success rate or shorten tracheal intubation time. However, dynamic bougies seem to improve first-attempt tracheal intubation rate in patients with difficult airways and in those intubated with a Macintosh blade. Further research is needed for definitive conclusions. REGISTRATION OF PROSPERO: CRD42023472122.

5.
Healthcare (Basel) ; 12(4)2024 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-38391827

RESUMEN

The aim of the study was to test the hypothesis that the results obtained with three different types of video laryngoscopes (UESCOPE VL-400, I-View, Non-Channeled Aitraq) with and without an endotracheal stylet should be better than the results obtained with a Macintosh laryngoscope in a simulated out-of-hospital scenario by a person without clinical experience. Primary outcome measures were the time taken to successfully achieve tracheal intubation (TI). Secondary outcomes included the grade of glottic view (Cormack and Lehane grades 1-4), the incidence of successful TI, the number of audible dental clicks indicating potential dental damage, the level of effort required to perform TI, and the operator's comfort during the procedure. The time required to achieve tracheal intubation successfully was significantly longer with the Macintosh laryngoscope and Airtraq than with the other video laryngoscopes. The use of the stylet significantly reduced the time required for tracheal intubation with the Macintosh laryngoscope (21.8 sec. vs. 24.0 sec., p = 0.026), UESCOPE VL 400 (18.1 sec. vs. 23.4 sec., p = 0.013), and Airtraq (22.7 sec. vs. 34.5 sec., p < 0.001). There were no significant differences in intubation time when using the I-View with or without stylets. No differences were observed in the Cormack-Lehane grading. The success rate of intubation was 100% for the Macintosh and I-View laryngoscopes used with or without stylets and for the UESCOPE VL 400 and Airtraq laryngoscopes used with stylets. Without stylets, the success rate of intubation was 96.6% for the UESCOPE VL 400 and 86.6% for the Airtraq. There were no significant differences in the risk of dental damage between the Macintosh, UESCOPE VL 400, I-View, and Airtraq laryngoscopes, regardless of the use of stylets (without and with stylets). The use of stylets significantly reduced dental damage only for the Airtraq laryngoscope: 8 (26.6%) vs. 2 (6.6%). Statistically significant differences in perceived exertion were observed between the mentioned laryngoscopes, both with and without stylets. However, there were no differences in the comfort of use between the laryngoscopes, regardless of the use of stylets (without and with stylets. The use of stylets led to better comfort in the case of the Macintosh (2.5 vs. 3, p = 0.043) and UESCOPE VL 400 (2 vs. 3, p = 0.008) laryngoscopes. In our study, the I-View and UESCOPE VL-400 video laryngoscopes provided better intubation results than the Macintosh laryngoscope in terms of time needed to intubate, glottis visibility, and reduction in dental damage. The use of the stylet did not significantly improve the intubation results compared to the results obtained in direct laryngoscopy. Due to the small study group and the manikin model, additional studies should be performed on a larger study group.

7.
Healthcare (Basel) ; 11(18)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37761667

RESUMEN

A wide range of airway devices and techniques have been created to enhance the safety of airway management. However, airway management remains a challenge. All techniques are susceptible to failure. Therefore, it is necessary to have and know the greatest number of alternatives to treat even the most challenging airway successfully. The aim of this narrative review is to describe some new devices, such as video laryngeal masks, articulated stylets, and non-standard techniques, for laryngeal mask insertion and endotracheal intubation that are not applied in daily practice, but that could be highly effective in overcoming a difficulty related to airway management. Artificial intelligence and 3D technology for airway management are also discussed.

8.
BMC Anesthesiol ; 23(1): 274, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37580649

RESUMEN

ERAS programs aim to reduce the length of hospital stays and lower costs, and minimize the risk of postoperative complications and readmissions while enhancing the overall patient experience. BMC Anesthesiology has initiated a new collection on ERAS, urging investigators to conduct large-scale, high-quality studies that address the existing knowledge gap.


Asunto(s)
Recuperación Mejorada Después de la Cirugía , Humanos , Complicaciones Posoperatorias/prevención & control , Tiempo de Internación , Recuperación de la Función , Atención Perioperativa
10.
Simul Healthc ; 2023 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-37185879

RESUMEN

INTRODUCTION: Personal protective equipment (PPE) reduces the risk of pathogens reaching the skin and clothing of health care personnel. We hypothesize that doffing PPE following verbal instructions by a supervisor is more effective in reducing contamination compared with doffing without verbal instructions. Our primary aim was to determine contamination rates with and without supervised doffing. The secondary aim was to determine the number and localization of contaminated body sites and PPE removal times in both groups. METHODS: Staff members of Bnai Zion Medical Center participated in this single-center, randomized simulation study (NCT05008627). Using a crossover design, all participants donned and doffed the PPE twice, once under guidance from a trained supervisor and then independently without supervision (group A), or vice versa (group B). Participants were randomized to either group A or B using a computer-generated random allocation sequence. The PPE was "contaminated" with Glo Germ on the thorax, shoulders, arms, hands, legs, and face shield. After doffing the PPE, the participant was examined under ultraviolet light to detect traces of contamination. The following variables were collected: contamination rates, the number and localization of contaminated body sites, and PPE doffing time. RESULTS: Forty-nine staff members were included. In group A, the contamination rate was significantly lower (8% vs. 47%; χ2 = 17.19; p < 0.001). The sites most frequently contaminated were the neck and hands. Mean PPE doffing time under verbal instructions was significantly longer [mean (SD): 183.98 (3.63) vs. 68.43 (12.75) seconds, P < 0.001] compared with unsupervised doffing. CONCLUSIONS: In a simulated setting, PPE doffing following step-by-step verbal instructions from a trained supervisor reduces the rate of contamination but prolongs doffing time. These findings could have important implications for clinical practice and could further protect health care workers against contamination from emerging and high-consequence pathogens.

11.
Turk J Anaesthesiol Reanim ; 51(2): 80-84, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37140571

RESUMEN

Non-invasive ventilation application in neurocritical care with risk of pneumocephalus is controversial. Non-invasive ventilation-related increased intrathoracic pressure increases intracranial pressure via direct transmission of intrathoracic pressure to the intracranial cavity. In addition, increased thoracic pressure decreases venous return to the heart and increases vena jugularis interna pressure, thereby increasing cerebral blood volume. Pneumocephalus is one of the major concerns after non-invasive ventilation application in head/brain trauma patients. Non-invasive mechanical ventilation may be performed in limited conditions in head trauma/brain surgery with appropriate and close monitoring. High-flow nasal cannula oxygen therapy can provide higher FiO2 as manifested by a larger increase in PaO2/FiO2 ratio and provide the theoretical basis in pneumocephalus because augmenting the PaO2 more effectively would accelerate nitrogen (N2) washout. As a result, non-invasive mechanical ventilation may be performed in limited manner in head trauma/ brain surgery with appropriate and close monitoring.

12.
Healthcare (Basel) ; 11(8)2023 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-37107952

RESUMEN

Airway device-associated infections resulting from the cross-contamination of reusable laryngoscopes are one of the main causes of healthcare-associated infections. Laryngoscope blades are highly contaminated with various pathogens, including Gram-negative bacilli, which can cause prolonged hospitalization, high morbidity and mortality risks, the development of antibiotic-resistant microorganisms, and significant costs. Despite the Centers for Disease Control and Prevention and the American Society of Anesthesiologists' recommendations, this national survey of 248 Spanish anesthesiologists showed that there is great variability in the processing of reusable laryngoscopes in Spain. Nearly a third of the respondents did not have an institutional disinfection protocol, and 45% of them did not know the disinfection procedure used. Good practices for the prevention and control of cross-contamination can be ensured through compliance with evidence-based guidelines, education of healthcare providers, and audits of clinical practices.

16.
Expert Rev Med Devices ; 19(11): 847-858, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36308748

RESUMEN

INTRODUCTION: Video laryngeal masks have become alternatives to classical supraglottic airway devices in recent years. This review provides information on the background of these new medical devices, the most popular and widely used video laryngeal masks, their advantages, disadvantages and their main applications in airway management. AREAS COVERED: In this review, the physical differences between video laryngeal masks and second-generation laryngeal mask airways, and their properties in specific clinical settings are discussed. EXPERT COMMENTARY: To limit airway-related morbidity, an optimal position of supraglottic airway devices must be the primary goal. Extensive research has shown that blindly inserted laryngeal mask can be malpositioned in 50% to 80% of the cases. Therefore, blind insertion should be the exception rather than the rule unlike current practice. Video laryngeal mask airways have clear advantages in routine use and in difficult airway management since they allow a vision-guided technique. Henceforth, the properties perceived in clinical practice must be endorsed with quality clinical evidence.


Asunto(s)
Máscaras Laríngeas , Humanos , Intubación Intratraqueal , Manejo de la Vía Aérea , Proyectos de Investigación
17.
Indian J Crit Care Med ; 26(8): 938-948, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36042773

RESUMEN

Aim: This systematic review aimed to investigate the drugs used and their potential effect on noninvasive ventilation (NIV). Background: NIV is used increasingly in acute respiratory failure (ARF). Sedation and analgesia are potentially beneficial in NIV, but they can have a deleterious impact. Proper guidelines to specifically address this issue and the recommendations for or against it are scarce in the literature. In the most recent guidelines published in 2017 by the European Respiratory Society/American Thoracic Society (ERS/ATS) relating to NIV use in patients having ARF, the well-defined recommendation on the selective use of sedation and analgesia is missing. Nevertheless, some national guidelines suggested using sedation for agitation. Methods: Electronic databases (PubMed/Medline, Google Scholar, and Cochrane library) from January 1999 to December 2019 were searched systematically for research articles related to sedation and analgosedation in NIV. A brief review of the existing literature related to sedation and analgesia was also done. Review results: Sixteen articles (five randomized trials) were analyzed. Other trials, guidelines, and reviews published over the last two decades were also discussed. The present review analysis suggests dexmedetomidine as the emerging sedative agent of choice based on the most recent trials because of better efficacy with an improved and predictable cardiorespiratory profile. Conclusion: Current evidence suggests that sedation has a potentially beneficial role in patients at risk of NIV failure due to interface intolerance, anxiety, and pain. However, more randomized controlled trials are needed to comment on this issue and formulate strong evidence-based recommendations. How to cite this article: Karim HMR, Sarc I, Calandra C, Spadaro S, Mina B, Ciobanu LD, et al. Role of Sedation and Analgesia during Noninvasive Ventilation: Systematic Review of Recent Evidence and Recommendations. Indian J Crit Care Med 2022;26(8):938-948.

19.
J Clin Anesth ; 80: 110752, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35405517

RESUMEN

STUDY OBJECTIVE: Assess the relationship between the Enhanced Recovery After Surgery (ERAS®) pathway and routine care and 30-day postoperative outcomes. DESIGN: Prospective cohort study. SETTING: European centers (185 hospitals) across 21 countries. PATIENTS: A total of 2841 adult patients undergoing elective colorectal surgery. Each hospital had a 1-month recruitment period between October 2019 and September 2020. INTERVENTIONS: Routine perioperative care. MEASUREMENTS: Twenty-four components of the ERAS pathway were assessed in all patients regardless of whether they were treated in a formal ERAS pathway. A multivariable and multilevel logistic regression model was used to adjust for baseline risk factors, ERAS elements and country-based differences. RESULTS: A total of 1835 patients (65%) received perioperative care at a self-declared ERAS center, 474 (16.7%) developed moderate-to-severe postoperative complications, and 63 patients died (2.2%). There was no difference in the primary outcome between patients who were or were not treated in self-declared ERAS centers (17.1% vs. 16%; OR 1.00; 95%CI, 0.79-1.27; P = 0.986). Hospital stay was shorter among patients treated in self-declared ERAS centers (6 [5-9] vs. 8 [6-10] days; OR 0.82; 95%CI, 0.78-0.87; P < 0.001). Median adherence to 24 ERAS elements was 57% [48%-65%]. Adherence to ERAS-pathway quartiles (≥65% vs. <48%) suggested that patients with the highest adherence rates experienced a lower risk of moderate-to-severe complications (15.9% vs. 17.8%; OR 0.71; 95%CI, 0.53-0.96; P = 0.027), lower risk of death (0.3% vs. 2.9%; OR 0.10; 95%CI, 0.02-0.42; P = 0.002) and shorter hospital stay (6 [4-8] vs. 7 [5-10] days; OR 0.74; 95%CI, 0.69-0.79; P < 0.001). CONCLUSIONS: Treatment in a self-declared ERAS center does not improve outcome after colorectal surgery. Increased adherence to the ERAS pathway is associated with a significant reduction in overall postoperative complications, lower risk of moderate-to-severe complications, shorter length of hospital stay and lower 30-day mortality.


Asunto(s)
Cirugía Colorrectal , Recuperación Mejorada Después de la Cirugía , Adulto , Cirugía Colorrectal/efectos adversos , Procedimientos Quirúrgicos Electivos/efectos adversos , Humanos , Tiempo de Internación , Estudios Observacionales como Asunto , Atención Perioperativa/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Prospectivos
20.
Anesth Analg ; 134(4): 791-801, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35086112

RESUMEN

BACKGROUND: Some patients still report moderate-to-severe postoperative pain after cesarean delivery. Local anesthetic wound infusion improves acute pain and might act on peripheral and central sensitization mechanisms; however, no studies have proved this hypothesis. We evaluated the potential benefits of continuous wound infusion of levobupivacaine after cesarean delivery on secondary hyperalgesia (primary end point) and primary hyperalgesia, pain relief, persistent pain, and inflammatory and metabolic stress response. METHODS: Healthy women scheduled for elective cesarean delivery participated in this prospective, randomized, triple-blind, placebo-controlled trial (NCT01458431). All patients received spinal anesthesia with 0.5% hyperbaric bupivacaine with fentanyl and a multiholed wound catheter placed under the fascia. Women were randomized to receive continuous wound infusion (0.35% levobupivacaine 7 mL/h for 48 hours; group L) or an equal volume of saline (group S). Secondary hyperalgesia to punctate mechanical stimuli was evaluated using dynamic tests, and primary hyperalgesia was evaluated using an electronic von Frey anesthesiometer; both were assessed at 24, 48, and 72 hours. The following variables were collected: intensity of postoperative parietal and visceral pain at rest and on movement rated on a visual analog scale >72 hours, time to first bolus of patient-controlled analgesia (PCA), cumulative dose of rescue morphine (PCA) and acetaminophen, ability to sleep and sleep quality, and patient satisfaction. Persistent postoperative pain was evaluated during a telephone interview at 1, 3, 6, and 12 months after surgery. C-reactive protein, acid glycoprotein, preprandial glucose, insulin, cortisol, prolactin, growth hormone, and interleukin-6 were measured before cesarean delivery and at 8, 24, and 48 hours. Adverse events and patient outcomes were recorded. RESULTS: Seventy women were included. In group L, the area of secondary hyperalgesia was significantly reduced (43.4 [18.5-80] vs 68.4 [39.0-136] cm2 and 45.1 [0.9-89.8] vs 67.3 [31.3-175] cm2 at 24 and 48 hours, respectively; group:time interaction P value < .001), the mechanical pain threshold was significantly higher at 24 hours (633 [441-802] vs 417 [300-572] g.mm-2; P = .001), and morphine consumption was significantly lower at 24 hours (4 [2-11] vs 11[6-23]; P = .003) compared with group S. Levobupivacaine had no effect on persistent postoperative pain at 1, 3, 6, and 12 months. Plasma insulin levels in the immediate postoperative period and at 8, 24, and 48 hours were significantly lower in group L (P < .001). There were no significant differences in other biochemical parameters of inflammatory and endocrine-metabolic response. CONCLUSIONS: Levobupivacaine wound infusion provides adequate analgesia and might be an effective antihyperalgesic adjunct.


Asunto(s)
Analgésicos Opioides , Morfina , Analgesia Controlada por el Paciente , Anestésicos Locales/efectos adversos , Método Doble Ciego , Femenino , Humanos , Hiperalgesia/inducido químicamente , Hiperalgesia/diagnóstico , Hiperalgesia/tratamiento farmacológico , Insulina , Levobupivacaína , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/tratamiento farmacológico , Dolor Postoperatorio/etiología , Embarazo , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...