Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Acta Orthop ; 95: 61-66, 2024 Jan 30.
Artículo en Inglés | MEDLINE | ID: mdl-38288960

RESUMEN

BACKGROUND AND PURPOSE: Hemiarthroplasty (HA) is the usual treatment for displaced femoral neck fractures (FNF) in elderly patients. Patients may be unsuitable for HA due to secondary conditions such as systemic infections or severe neurological conditions, which is why Girdlestone resection arthroplasty (GRA) may be an option. We aimed to determine (1) patient survival in matched patient groups treated with either GRA or HA and (2) functional outcomes. PATIENTS AND METHODS: 21 patients treated with GRA for FNF in a German university hospital were retrospectively reviewed (2015-2019). After matching for age and comorbidities, a control group of 42 HA patients was established. Patient survival was determined by a Kaplan-Meier analysis. The mean follow-up (FU) was 1.5 (0-4.4) years. Function at FU was documented using the modified Harris Hip Score (mHHS) and the National Hip Fracture Database (NHFD) mobility score. RESULTS: The 1-month-mortality was 19% in the GRA group and 12% in the HA group; the 1-year mortality was 71% and 49%, respectively (P = 0.01). The mHHS at FU was lower in the GRA group than in the HA group (22 [range 0-50] vs. 46 [11-80]). 82% of patients in the GRA group were bedridden post-surgery as opposed to 19% in the HA group. CONCLUSION: Patients with HA after FNF had higher survival and better functional outcomes when compared with GRA in matched patient groups. Considering this, GRA for FNF should be selected restrictively.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Cuello Femoral , Hemiartroplastia , Humanos , Anciano , Estudios Retrospectivos , Artroplastia de Reemplazo de Cadera/efectos adversos , Hemiartroplastia/efectos adversos , Anciano Frágil , Fracturas del Cuello Femoral/cirugía , Fracturas del Cuello Femoral/etiología , Resultado del Tratamiento
2.
J Clin Med ; 12(17)2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37685535

RESUMEN

PURPOSE: Articular cartilage defects are a prevalent consequence of femoroacetabular impingement (FAI) in young active patients. In accordance with current guidelines, large chondral lesions of the hip joint over 2 cm2 are recommended to be treated with matrix-associated, autologous chondrocyte transplantation (MACT); however, the conditions in the hip joint are challenging for membrane-based MACT options. Injectable MACT products can solve this problem. The purpose of the trial was to assess clinical and radiological outcomes 24 months after injectable MACT of focal chondral lesions caused by FAI. METHODS: We present data of 21 patients with focal cartilage defects of the hip [3.0 ± 1.4 cm2 (mean ± SD)], ICRS Grade III and IV caused by CAM-type impingement, who underwent arthroscopic MACT (NOVOCART® Inject) and FAI correction. The outcome was evaluated with the patient-reported outcome instruments iHOT33 and EQ-5D-5L (index value and VAS), whilst graft morphology was assessed based on the MOCART score over a follow-up period of 24 months. RESULTS: The iHOT33 score increased significantly from 52.9 ± 21.1 (mean ± SD) preoperatively to 85.8 ± 14.8 (mean ± SD; p < 0.0001) 24 months postoperatively. The EQ-5D-5L index value (p = 0.0004) and EQ-5D VAS (p = 0.0006) showed a statistically significant improvement as well. MRI evaluation after 24 months showed successful integration of the implant in all patients with a complete defect filling in 11 of 14 patients. CONCLUSIONS: Injectable MACT for the treatment of full-thickness chondral lesions of the hip joint due to FAI in combination with FAI correction improved symptoms, function, and quality of life in the treated cohort. Alongside the treatment of the underlying pathology by the FAI correction, the developed cartilage defect can be successfully repaired by MACT, which is of considerable clinical relevance.

3.
EFORT Open Rev ; 8(7): 509-521, 2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37395720

RESUMEN

With the implementation of the new MDR 2017/745 by the European Parliament, more robust clinical and pre-clinical data will be required due to a more stringent approval process. The EFORT Implant and Patient Safety Initiative WG1 'Introduction of Innovation', combined knowledge of orthopaedic surgeons, research institutes, orthopaedic device manufacturers, patient representatives and regulatory authorities to develop a comprehensive set of recommendations for the introduction of innovations in joint arthroplasty within the boundaries of MDR 2017/745. Recommendations have been developed to address key questions about pre-clinical and clinical requirements for the introduction of new implants and implant-related instrumentation with the participation of a steering group, invited by the EFORT Board in dialogue with representatives from European National Societies and Speciality Societies. Different degrees of novelty and innovation were described and agreed on in relation to when surgeons can start, using implants and implant-related instrumentation routinely. Before any clinical phase of a new implant, following the pre-market clinical investigation or the equivalent device PMCF pathway, it is a common understanding that all appropriate pre-clinical testing (regulatory mandatory and evident state of the art) - which has to be considered for a specific device - has been successfully completed. Once manufacturers receive the CE mark for a medical device, it can be used in patients routinely when a clinical investigation has been conducted to demonstrate the conformity of devices according to MDR Article 62 or full equivalence for the technical, biological and clinical characteristics has been demonstrated (MDR, Annex XIV, Part A, 3.) and a PMCF study has been initiated.

4.
J Arthroplasty ; 38(11): 2415-2422, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37271233

RESUMEN

BACKGROUND: Large acetabular bone defects present a serious challenge in revision total hip arthroplasty. The off-label use of antiprotrusio cages in combination with tantalum augments is a promising treatment option in these difficult situations. METHODS: Between 2008 and 2013, 100 consecutive patients underwent acetabular cup revision with a cage-augment combination in Paprosky 2 and 3 defect types (including pelvic discontinuities). There were 59 patients available for follow-up. The primary endpoint was the explantation of the cage-and-augment construct. The secondary endpoint was acetabular cup revision for any reason. Also, radiographic and functional outcomes (Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score) were evaluated. Implant survival rates were determined using a Kaplan-Meier analysis. The significance level was set at P < .05. RESULTS: Explantation-free survivorship of the "Cage-and-Augment" system was 91.9% after a mean follow-up of 6.2 years (range, 0 to 12.8). All 6 explantations were due to periprosthetic joint infection (PJI). The overall revision-free implant survival rate was 85.7%, including 6 additional liner revisions due to instability. In addition, 6 early PJI occurred, which were successfully treated with debridement, irrigation, and implant retention. We did observe one patient who had radiographic loosening of the construct without necessity for treatment. CONCLUSION: The combination of an antiprotrusio cage with tantalum augments is a promising technique in treating large acetabular defects. A major risk of PJI and instability due to large bone and soft tissue defects needs special attention.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Prótesis de Cadera/efectos adversos , Estudios de Seguimiento , Tantalio , Falla de Prótesis , Acetábulo/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/métodos , Reoperación/métodos , Metales , Estudios Retrospectivos
5.
J Orthop Res ; 41(11): 2501-2515, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37132090

RESUMEN

Total hip joint replacement (THR) is clinically well-established. In this context, the resulting range of motion (ROM) is crucial for patient satisfaction when performing joint movements. However, the ROM for THR with different bone preserving strategies (short hip stem and hip resurfacing) raises the question of whether the ROM is comparable with conventional hip stems. Therefore, this computer-based study aimed to investigate the ROM and type of impingement for different implant systems. An established framework with computer-aided design 3D models based on magnetic resonance imaging data of 19 patients with hip osteoarthritis was used to analyse the ROM for three different implant systems (conventional hip stem vs. short hip stem vs. hip resurfacing) during typical joint movements. Our results revealed that all three designs led to mean maximum flexion higher than 110°. However, hip resurfacing showed less ROM (-5% against conventional and -6% against short hip stem). No significant differences were observed between the conventional and short hip stem during maximum flexion and internal rotation. Contrarily, a significant difference was detected between the conventional hip stem and hip resurfacing during internal rotation (p = 0.003). The ROM of the hip resurfacing was lower than the conventional and short hip stem during all three movements. Furthermore, hip resurfacing shifted the impingement type to implant-to-bone impingement compared with the other implant designs. The calculated ROMs of the implant systems achieved physiological levels during maximum flexion and internal rotation. However, bone impingement was more likely during internal rotation with increasing bone preservation. Despite the larger head diameter of hip resurfacing, the ROM examined was substantially lower than that of conventional and short hip stem.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Osteoartritis de la Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Osteoartritis de la Cadera/cirugía , Rango del Movimiento Articular/fisiología , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/cirugía
6.
Orthopadie (Heidelb) ; 52(4): 282-292, 2023 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-36894594

RESUMEN

Pelvic osteotomies are an established treatment for symptomatic adult hip dysplasia with a promising long-term outcome. Results depend not only on the achieved acetabular reorientation but also on patient-factors like preoperative joint condition (degree of osteoarthritis and joint congruency) and age. Additionally, the diagnosis and appropriate therapy of impingement-associated hip deformities is essential in order to achieve good mid- and long-term outcomes. The influence of chondrolabral pathology on the outcome of pelvic osteotomies is not yet defined. Symptomatic patients with residual dysplasia after previous pelvic or acetabular osteotomies can benefit from an additional osteotomy, although results can be worse in comparison to prior unoperated joints. Obesity can make surgery more demanding and increases the complication profile of PAO, although it has no influence on the postoperative outcome. Regarding the overall prognosis after an osteotomy, the consideration of combined risk factors is superior to the concentration on individual factors alone.


Asunto(s)
Luxación Congénita de la Cadera , Luxación de la Cadera , Osteoartritis , Adulto , Humanos , Articulación de la Cadera/anomalías , Luxación de la Cadera/complicaciones , Acetábulo/cirugía , Luxación Congénita de la Cadera/complicaciones , Osteoartritis/complicaciones
7.
Clin Orthop Relat Res ; 481(8): 1527-1540, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-36961220

RESUMEN

BACKGROUND: Osteonecrosis of the femoral head (ONFH) is a disabling disease that can ultimately progress to collapse of the femoral head, often resulting in THA. Core decompression of the femoral head combined with cell therapies have shown beneficial effects in previous clinical studies in patients with early-stage (Association Research Circulation Osseous [ARCO] Stage I and II) ONFH. However, high-quality evidence confirming the efficacy of this treatment modality is still lacking. QUESTIONS/PURPOSES: (1) Is core decompression combined with autologous osteoblastic cell transplantation superior to core decompression with placebo implantation in relieving disease-associated pain and preventing radiologic ONFH progression in patients with nontraumatic early-stage ONFH? (2) What adverse events occurred in the treatment and control groups? METHODS: This study was a Phase III, multicenter, randomized, double-blind, controlled study conducted from 2011 to 2019 (ClinicalTrails.gov registry number: NCT01529008). Adult patients with ARCO Stage I and II ONFH were randomized (1:1) to receive either core decompression with osteoblastic cell transplantation (5 mL with 20 x 10 6 cells/mL in the study group) or core decompression with placebo (5 mL of solution without cells in the control group) implantation. Thirty percent (68 of 230) of the screened patients were eligible for inclusion in the study; of these, 94% (64 of 68) underwent a bone marrow harvest or sham procedure (extended safety set) and 79% (54 of 68) were treated (study group: 25 patients; control group: 29). Forty-nine patients were included in the efficacy analyses. Similar proportions of patients in each group completed the study at 24 months of follow-up (study group: 44% [11 of 25]; control: 41% [12 of 29]). The study and control groups were comparable in important ways; for example, in the study and control groups, most patients were men (79% [27 of 34] and 87% [26 of 30], respectively) and had ARCO Stage II ONFH (76% [19 of 25] and 83% [24 of 29], respectively); the mean age was 46 and 45 years in the study and control groups, respectively. The follow-up period was 24 months post-treatment. The primary efficacy endpoint was the composite treatment response at 24 months, comprising the clinical response (clinically important improvement in pain from baseline using the WOMAC VA3.1 pain subscale, defined as 10 mm on a 100-mm scale) and radiologic response (the absence of progression to fracture stage [≥ ARCO Stage III], as assessed by conventional radiography and MRI of the hips). Secondary efficacy endpoints included the percentages of patients achieving a composite treatment response, clinical response, and radiologic response at 12 months, and the percentage of patients undergoing THA at 24 months. We maintained a continuous reporting system for adverse events and serious adverse events related to the study treatment, bone marrow aspiration and sham procedure, or other study procedures throughout the study. A planned, unblinded interim analysis of efficacy and adverse events was completed at 12 months. The study was discontinued because our data safety monitoring board recommended terminating the study for futility based on preselected futility stopping rules: conditional power below 0.20 and p = 0.01 to detect an effect size of 10 mm on the 100-mm WOMAC VA3.1 pain subscale (improvement in pain) and the absence of progression to fracture (≥ ARCO Stage III) observed on radiologic assessment, reflecting the unlikelihood that statistically beneficial results would be reached at 24 months after the treatment. RESULTS: There was no difference between the study and control groups in the proportion of patients who achieved a composite treatment response at 24 months (61% [14 of 23] versus 69% [18 of 26]; p = 0.54). There was no difference in the proportion of patients with a treatment response at 12 months between the study and control groups (14 of 21 versus 15 of 23; p = 0.92), clinical response (17 of 21 versus 16 of 23; p = 0.38), and radiologic response (16 of 21 versus 18 of 23; p = 0.87). With the numbers available, at 24 months, there was no difference in the proportion of patients who underwent THA between the study and control groups (24% [six of 25] versus 14% [four of 29]). There were no serious adverse events related to the study treatment, and only one serious adverse event (procedural pain in the study group) was related to bone marrow aspiration. Nonserious adverse events related to the treatment were rare in the study and control groups (4% [one of 25] versus 14% [four of 29]). Nonserious adverse events related to bone marrow or sham aspiration were reported by 15% (five of 34) of patients in the study group and 7% (two of 30) of patients in the control group. CONCLUSION: Our study did not show any advantage of autologous osteoblastic cells to improve the results of core decompression in early-stage (precollapse) ONFH. Adverse events related to treatment were rare and generally mild in both groups, although there might have been a potential risk associated with cell expansion. Based on our findings, we do not recommend the combination of osteoblastic cells and core decompression in patients with early-stage ONFH. Further, well-designed studies should be conducted to explore whether other treatment modalities involving a biological approach could improve the overall results of core decompression. LEVEL OF EVIDENCE: Level II, therapeutic study.


Asunto(s)
Necrosis de la Cabeza Femoral , Cabeza Femoral , Adulto , Masculino , Humanos , Femenino , Resultado del Tratamiento , Cabeza Femoral/cirugía , Necrosis de la Cabeza Femoral/diagnóstico por imagen , Necrosis de la Cabeza Femoral/cirugía , Descompresión Quirúrgica/efectos adversos , Descompresión Quirúrgica/métodos , Método Doble Ciego
9.
J Orthop Res ; 41(6): 1365-1375, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36222474

RESUMEN

Polymethylmethacrylate (PMMA) removal during septic total joint arthroplasty revision is associated with a high fracture and perforation risk. Ultrasonic cement removal is considered a bone-preserving technique. Currently, there is still a lack of sound data on efficacy as it is difficult to detect smaller residues with reasonable technical effort. However, incomplete removal is associated with the risk of biofilm coverage of the residue. Therefore, the study aimed to investigate the efficiency of ultrasonic-based PMMA removal in a human cadaver model. The femoral components of a total hip and a total knee prosthesis were implanted in two cadaver femoral canals by 3rd generation cement fixation technique. Implants were then removed. Cement mantle extraction was performed with the OSCAR-3-System ultrasonic system (Orthofix®). Quantitative analysis of cement residues was carried out with dual-energy and microcomputer tomography. With a 20 µm resolution, in vitro microcomputer tomography visualized tiniest PMMA residues. For clinical use, dual-energy computer tomography tissue decomposition with 0.75 mm resolution is suitable. With ultrasound, more than 99% of PMMA was removed. Seven hundred thirty-four residues with a mean volume of 0.40 ± 4.95 mm3 were identified with only 4 exceeding 1 cm in length in at least one axis. Ultrasonic cement removal of PMMA was almost complete and can therefore be considered a highly effective technique. For the first time, PMMA residues in the sub-millimetre range were detected by computer tomography. Clinical implications of the small remaining PMMA fraction on the eradication rate of periprosthetic joint infection warrants further investigations.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Humanos , Cementos para Huesos/química , Polimetil Metacrilato/química , Ultrasonido , Reoperación , Cadáver , Tomografía , Computadores
10.
Orthopadie (Heidelb) ; 52(1): 12-20, 2023 Jan.
Artículo en Alemán | MEDLINE | ID: mdl-35759041

RESUMEN

Hip arthroplasty revision management can range from simple procedures using standard implants to complex surgical interventions requiring the combined use of revision cups, metal augments, bone grafts, and antiprotrusio cages. The adequate restoration of biomechanics and function of the hip joint with reconstruction of the original center of rotation can be challenging. We present an overview of various available techniques with the associated implant and anchoring strategies and the respective clinical results depending on the acetabular defect situation.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Falla de Prótesis , Reoperación/métodos , Articulación de la Cadera
11.
Arthritis Care Res (Hoboken) ; 75(4): 869-875, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-34738320

RESUMEN

OBJECTIVE: To investigate whether osteoarthritis (OA)-specific assessment values (i.e., Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]) and generic pain and function (visual analog scale, Hanover Functionality Status Questionnaire) measured before and 12 months after arthroplasty are associated with the risk of long-term mortality in a cohort of patients with advanced OA of the hip or knee. METHODS: The Ulm Osteoarthritis Study was a prospective cohort study of OA patients with unilateral total hip or knee replacement between January 1995 and December 1996. Correlation coefficients were calculated to describe the agreement between the different assessments. Mortality was assessed during the follow-up period (last update July 2019). Cox proportional regression models were used to estimate hazard ratios (HRs) for mortality after adjusting for covariates. RESULTS: Arthroplasty was accompanied by a clear reduction in pain and improved function throughout all assessments in the 706 included patients. The results of the adjusted Cox models showed no relationship between baseline and follow-up joint-specific WOMAC assessments and long-term mortality. However, an independent increased risk of mortality was found with generic function assessments. In the final adjusted model, the HR for the 12-month follow-up value was 1.79 (95% confidence interval 1.24-2.60) in the group with clinically relevant impairment versus the reference group. CONCLUSION: Poor function based on the generic assessment was associated with increased long-term mortality, suggesting that functional impairments in daily life activities may be more important for long-term survival than OA-specific impairments in this patient group.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Osteoartritis de la Cadera , Osteoartritis de la Rodilla , Humanos , Osteoartritis de la Rodilla/diagnóstico , Osteoartritis de la Rodilla/cirugía , Osteoartritis de la Rodilla/etiología , Pronóstico , Estudios Prospectivos , Osteoartritis de la Cadera/diagnóstico , Osteoartritis de la Cadera/cirugía , Osteoartritis de la Cadera/etiología , Artroplastia de Reemplazo de Rodilla/efectos adversos , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/etiología
12.
Z Orthop Unfall ; 161(1): 74-84, 2023 Feb.
Artículo en Inglés, Alemán | MEDLINE | ID: mdl-34500491

RESUMEN

Dual-mobility cups (DMCs) were introduced in France more than 40 years ago and are increasingly used not only in hip revision but also primary hip arthroplasty. Due to a simulated large-head articulation and increased jumping distance, DMCs can contribute to a high range of motion in the hip joint and reduce the risk of instability. Numerous studies have reported low dislocation rates and high survival rates in the mid-term follow-up. Nevertheless, long-term data, especially on primary hip replacement, remain limited, and the effect of recent designs and material innovations is still unclear. Therefore, primary DMCs are mainly proposed in patients at high risk for dislocation (i.e. pelvitrochanteric insufficiency, compromised spinopelvic mobility, neuromuscular disorders, obesity and femoral neck fractures). Based on a review of recently published studies referring to these indications, the current study discusses the advantages and disadvantages of DMCs.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Luxación de la Cadera , Prótesis de Cadera , Luxaciones Articulares , Humanos , Falla de Prótesis , Reoperación , Diseño de Prótesis , Luxaciones Articulares/cirugía , Luxación de la Cadera/cirugía , Estudios Retrospectivos
13.
Eur J Epidemiol ; 37(10): 1107-1124, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36260190

RESUMEN

The German National Cohort (NAKO) is a multidisciplinary, population-based prospective cohort study that aims to investigate the causes of widespread diseases, identify risk factors and improve early detection and prevention of disease. Specifically, NAKO is designed to identify novel and better characterize established risk and protection factors for the development of cardiovascular diseases, cancer, diabetes, neurodegenerative and psychiatric diseases, musculoskeletal diseases, respiratory and infectious diseases in a random sample of the general population. Between 2014 and 2019, a total of 205,415 men and women aged 19-74 years were recruited and examined in 18 study centres in Germany. The baseline assessment included a face-to-face interview, self-administered questionnaires and a wide range of biomedical examinations. Biomaterials were collected from all participants including serum, EDTA plasma, buffy coats, RNA and erythrocytes, urine, saliva, nasal swabs and stool. In 56,971 participants, an intensified examination programme was implemented. Whole-body 3T magnetic resonance imaging was performed in 30,861 participants on dedicated scanners. NAKO collects follow-up information on incident diseases through a combination of active follow-up using self-report via written questionnaires at 2-3 year intervals and passive follow-up via record linkages. All study participants are invited for re-examinations at the study centres in 4-5 year intervals. Thereby, longitudinal information on changes in risk factor profiles and in vascular, cardiac, metabolic, neurocognitive, pulmonary and sensory function is collected. NAKO is a major resource for population-based epidemiology to identify new and tailored strategies for early detection, prediction, prevention and treatment of major diseases for the next 30 years.


Asunto(s)
Estudios Prospectivos , Masculino , Humanos , Femenino , Estudios de Cohortes , Alemania/epidemiología , Encuestas y Cuestionarios , Autoinforme
16.
Bone Joint J ; 104-B(7): 852-858, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35775169

RESUMEN

AIMS: Head-taper corrosion is a cause of failure in total hip arthroplasty (THA). Recent reports have described an increasing number of V40 taper failures with adverse local tissue reaction (ALTR). However, the real incidence of V40 taper damage and its cause remain unknown. The aim of this study was to evaluate the long-term incidence of ALTR in a consecutive series of THAs using a V40 taper and identify potentially related factors. METHODS: Between January 2006 and June 2007, a total of 121 patients underwent THA using either an uncemented (Accolade I, made of Ti12Mo6Zr2Fe; Stryker, USA) or a cemented (ABG II, made of cobalt-chrome-molybdenum (CoCrMo); Stryker) femoral component, both with a V40 taper (Stryker). Uncemented acetabular components (Trident; Stryker) with crosslinked polyethylene liners and CoCr femoral heads of 36 mm diameter were used in all patients. At a mean folllow-up of 10.8 years (SD 1.1), 94 patients (79%) were eligible for follow-up (six patients had already undergone a revision, 15 had died, and six were lost to follow-up). A total of 85 THAs in 80 patients (mean age 61 years (24 to 75); 47 (56%) were female) underwent clinical and radiological evaluation, including the measurement of whole blood levels of cobalt and chrome. Metal artifact reduction sequence MRI scans of the hip were performed in 71 patients. RESULTS: A total of 20 ALTRs were identified on MRI, with an incidence of 26%. Patients with ALTR had significantly higher median Co levels compared with those without ALTR (2.96 µg/l (interquartile range (IQR) 1.35 to 4.98) vs 1.44 µg/l (IQR 0.79 to 2.5); p = 0.019). Radiological evidence of osteolysis was also significantly associated with ALTR (p = 0.014). Median Cr levels were not significantly higher in those with ALTR compared with those without one (0.97 µg/l (IQR 0.72 to 1.9) v 0.67 µg/l (IQR 0.5 to 1.19; p = 0.080). BMI, sex, age, type of femoral component, head length, the inclination of the acetabular component, and heterotopic ossification formation showed no significant relationship with ALTR. CONCLUSION: Due to the high incidence of local ALTR in our cohort after more than ten years postoperatively, we recommend regular follow-up investigation even in asymptomatic patients with V40 taper and metal heads. As cobalt levels correlate with ALTR occurrence, routine metal ion screening and consecutive MRI investigation upon elevation could be discussed. Cite this article: Bone Joint J 2022;104-B(7):852-858.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Cromo , Aleaciones de Cromo , Cobalto , Corrosión , Femenino , Prótesis de Cadera/efectos adversos , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Reoperación/efectos adversos
17.
Medicina (Kaunas) ; 58(5)2022 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-35629991

RESUMEN

Background: Osteoarthritis of the hip (hip OA) is a leading cause of pain and disability in elderly people. If non-surgical therapies become ineffective, patients may consider total hip arthroplasty (THA). The biggest challenge in recommending a THA is identifying patients for whom the benefits of this procedure outweigh the potential risks. The aim of this initiative was to develop a clinical practice guideline with accompanying algorithm to guide consultations on THA, supported by a pocket-sized checklist. Methods: The initiative "Evidence- and consensus-based indication criteria for total hip replacement (EKIT-Hip)" used a stepwise approach, starting with an inauguration workshop, where a multidisciplinary German stakeholder panel from various scientific societies agreed on the working process. A Project Coordinating Group (PCG) was formed, and it performed a comprehensive systematic literature search of guidelines and systematic reviews related to the indication criteria for THA, as well as factors influencing outcomes. Based on best-available evidence, preliminary recommendations were formulated by the PCG and discussed with the stakeholder panel during a consensus meeting. In addition, the panel was asked to assess the feasibility of an extracted algorithm and to approve a final checklist. Results: In total, 31 recommendations were approved by 29 representatives of 23 societies. These were used to underpin an algorithm (EKIT-Algorithm), which indicates the minimum requirements for a THA (confirmed diagnosis of hip OA, present and documented individual burden of illness, ineffectiveness of non-surgical therapies, and absence of any contraindications). Once these criteria are fulfilled, further considerations should encompass the medical implications of modifiable risk factors and patients' individual treatment goals, as discussed during shared decision making. The subsequently developed checklist (EKIT-Checklist) lists relevant criteria for decision making. Conclusions: Adherence to the EKIT-Algorithm, conveniently accessed via the EKIT-Checklist, should improve the standardization of decision making leading to a recommendation for THA. By applying minimum requirements and patient-related risk factors, as well as considering patients' individual goals, it is possible to identify patients for whom the benefits of THA may exceed the potential risks.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteoartritis de la Cadera , Anciano , Consenso , Humanos , Osteoartritis de la Cadera/cirugía , Dolor
18.
J Arthroplasty ; 37(8): 1594-1601.e4, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35341925

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) is an elective surgery. Therefore, patient satisfaction with the results of surgery is paramount. The association between fulfillment of patients' expectations and satisfaction is well known. The aim of this study was to identify key expectations of patients with hip osteoarthritis awaiting THA. METHODS: A mixed-methods approach was used, consisting of two sequential parts. The questionnaire was developed based on literature review and focus group interviews. A nationwide survey was conducted in 21 orthopedic departments within Germany. RESULTS: Out of 691 obtained questionnaires, 636 were analyzed (mean age = 65.7 years (±11.3), 56.1% female). A majority of patients (≥75%) reported more than 20 complaints as 'present' due to hip osteoarthritis. A total of 9 key expectations were identified, which were reported by more than 75% of the patients as 'mandatory' for a successful THA. The identified key expectations were related to pain, range of motion, walking abilities, gait pattern, transitions, leisure and sports activities, awareness of the affected hip, satisfaction with health or life, and compensatory posture. A consistently high correlation was found between the complaints and the corresponding expectations. CONCLUSION: The expectations of patients have greatly expanded. In this study, a set of mandatory key expectations shared by the majority of patients was identified. The likelihood of fulfillment of key expectations should be assessed for weighing benefits and harms of available treatment options during the indication process. In addition, the results of this study might be used as a resource for shared decision-making.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteoartritis de la Cadera , Anciano , Artroplastia de Reemplazo de Cadera/métodos , Femenino , Alemania , Humanos , Masculino , Osteoartritis de la Cadera/cirugía , Satisfacción del Paciente , Encuestas y Cuestionarios , Resultado del Tratamiento
19.
J Psychosom Res ; 155: 110749, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35150982

RESUMEN

OBJECTIVE: According to the Common Sense Model (CSM), cognitive and emotional representations influence recovery. We used groups of individuals grouping multiple cognitive representations (schemas) to predict the recovery process after total hip arthroplasty (THR). METHODS: The aim of this prospective cohort study with three collection time points was to examine the significance of these schemas for functionality three and six months after THR. We assessed illness perception with the Illness Perception Questionnaire-Revised and the functionality with the Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Data were collected four weeks before (n = 317), three (n = 268), and six months after (n = 292) primary THR. Groups of individuals with the same schemas were identified using a two-step cluster analysis across cognitive representations. Controlling for WOMAC variables (functionality, stiffness, pain, and activities of daily living) before THR, we calculated the regression of schemas and emotional representations before THR on WOMAC variables after THR. RESULTS: Before THR, two cognitive schemes were found: Schema One: medium identity, long duration, many consequences, low personal and treatment control, and low coherence; Schema Two: low identity, short timeline, low consequences, and high personal and treatment control. Patients with Schema Two had better functionality and lower pain and stiffness three months after surgery compared to those with Schema One. After three months, the influence of cognitive schemas was stronger on functionality than that of emotional representation (f2: 0.04 /0.02). CONCLUSION: Further study is needed to determine whether a psychological intervention can change Schema One.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Osteoartritis de la Cadera , Actividades Cotidianas , Artroplastia de Reemplazo de Cadera/psicología , Humanos , Osteoartritis de la Cadera/cirugía , Dolor , Percepción , Estudios Prospectivos , Resultado del Tratamiento
20.
EFORT Open Rev ; 6(11): 982-1005, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34909220

RESUMEN

Off-label use is frequently practiced in primary and revision arthroplasty, as there may be indications for the application of implants for purposes outside the one the manufacturers intended.Under certain circumstances, patients may benefit from selective application of mix & match. This can refer to primary hip arthroplasty (if evidence suggests that the combination of devices from different manufacturers has superior results) and revision hip or knee arthroplasty (when the exchange of one component only is necessary and the invasiveness of surgery can be reduced).Within the EFORT 'Implant and Patient Safety Initiative', evidence- and consensus-based recommendations have been developed for the safe application of off-label use and mix & match in primary as well as revision hip and knee arthroplasty.Prior to the application of a medical device for hip or knee arthroplasty off-label and within a mix & match situation, surgeons should balance the risks and benefits to the patient, obtain informed consent, and document the decision process appropriately.Nevertheless, it is crucial for surgeons to only combine implants that are compatible. Mismatch of components, where their sizes or connections do not fit, may have catastrophic effects and is a surgical mistake.Surgeons must be fully aware of the features of the components that they use in off-label indications or during mix & match applications, must be appropriately trained and must audit their results.Considering the frequent practice of off-label and mix & match as well as the potential medico-legal issues, further research is necessary to obtain more data about the appropriate indications and outcomes for those procedures. Cite this article: EFORT Open Rev 2021;6:982-1005. DOI: 10.1302/2058-5241.6.210080.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...