Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Neuroimage ; 275: 120116, 2023 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-37169118

RESUMEN

Electroencephalographic (EEG) methods have great potential to serve both basic and clinical science approaches to understand individual differences in human neural function. Importantly, the psychometric properties of EEG data, such as internal consistency and test-retest reliability, constrain their ability to differentiate individuals successfully. Rapid and recent technological and computational advancements in EEG research make it timely to revisit the topic of psychometric reliability in the context of individual difference analyses. Moreover, pediatric and clinical samples provide some of the most salient and urgent opportunities to apply individual difference approaches, but the changes these populations experience over time also provide unique challenges from a psychometric perspective. Here we take a developmental neuroscience perspective to consider progress and new opportunities for parsing the reliability and stability of individual differences in EEG measurements across the lifespan. We first conceptually map the different profiles of measurement reliability expected for different types of individual difference analyses over the lifespan. Next, we summarize and evaluate the state of the field's empirical knowledge and need for testing measurement reliability, both internal consistency and test-retest reliability, across EEG measures of power, event-related potentials, nonlinearity, and functional connectivity across ages. Finally, we highlight how standardized pre-processing software for EEG denoising and empirical metrics of individual data quality may be used to further improve EEG-based individual differences research moving forward. We also include recommendations and resources throughout that individual researchers can implement to improve the utility and reproducibility of individual differences analyses with EEG across the lifespan.


Asunto(s)
Individualidad , Longevidad , Humanos , Niño , Reproducibilidad de los Resultados , Electroencefalografía/métodos , Potenciales Evocados
2.
Dev Cogn Neurosci ; 57: 101140, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35926469

RESUMEN

Event-Related Potential (ERP) designs are a common method for interrogating neurocognitive function with electroencephalography (EEG). However, the traditional method of preprocessing ERP data is manual-editing - a subjective, time-consuming processes. A number of automated pipelines have recently been created to address the need for standardization, automation, and quantification of EEG data pre-processing; however, few are optimized for ERP analyses (especially in developmental or clinical populations). We propose and validate the HAPPE plus Event-Related (HAPPE+ER) software, a standardized and automated pre-processing pipeline optimized for ERP analyses across the lifespan. HAPPE+ER processes event-related potential data from raw files through preprocessing and generation of event-related potentials for statistical analyses. HAPPE+ER also includes post-processing reports of both data quality and pipeline quality metrics to facilitate the evaluation and reporting of data processing in a standardized manner. Finally, HAPPE+ER includes post-processing scripts to facilitate validating HAPPE+ER performance and/or comparing to performance of other preprocessing pipelines in users' own data via simulated ERPs. We describe multiple approaches with simulated and real ERP data to optimize pipeline performance and compare to other methods and pipelines. HAPPE+ER software is freely available under the terms of GNU General Public License at https://www.gnu.org/licenses/#GPL.

3.
Neuroimage ; 260: 119390, 2022 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-35817295

RESUMEN

Lower-density Electroencephalography (EEG) recordings (from 1 to approximately 32 electrodes) are widely-used in research and clinical practice and enable scalable brain function measurement across a variety of settings and populations. Though a number of automated pipelines have recently been proposed to standardize and optimize EEG pre-processing for high-density systems with state-of-the-art methods, few solutions have emerged that are compatible with lower-density systems. However, lower-density data often include long recording times and/or large sample sizes that would benefit from similar standardization and automation with contemporary methods. To address this need, we propose the HAPPE In Low Electrode Electroencephalography (HAPPILEE) pipeline as a standardized, automated pipeline optimized for EEG recordings with lower density channel layouts of any size. HAPPILEE processes task-free (e.g., resting-state) and task-related EEG (including event-related potential data by interfacing with the HAPPE+ER pipeline), from raw files through a series of processing steps including filtering, line noise reduction, bad channel detection, artifact correction from continuous data, segmentation, and bad segment rejection that have all been optimized for lower density data. HAPPILEE also includes post-processing reports of data and pipeline quality metrics to facilitate the evaluation and reporting of data quality and processing-related changes to the data in a standardized manner. Here the HAPPILEE steps and their optimization with both recorded and simulated EEG data are described. HAPPILEE's performance is then compared relative to other artifact correction and rejection strategies. The HAPPILEE pipeline is freely available as part of HAPPE 2.0 software under the terms of the GNU General Public License at: https://github.com/PINE-Lab/HAPPE.


Asunto(s)
Electroencefalografía , Procesamiento de Señales Asistido por Computador , Artefactos , Electrodos , Electroencefalografía/métodos , Programas Informáticos
4.
Dev Cogn Neurosci ; 34: 63-74, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30075348

RESUMEN

Although the amygdala's role in shaping social behavior is especially important during early post-natal development, very little is known of amygdala functional development before childhood. To address this gap, this study uses resting-state fMRI to examine early amygdalar functional network development in a cross-sectional sample of 80 children from 3-months to 5-years of age. Whole brain functional connectivity with the amygdala, and its laterobasal and superficial sub-regions, were largely similar to those seen in older children and adults. Functional distinctions between sub-region networks were already established. These patterns suggest many amygdala functional circuits are intact from infancy, especially those that are part of motor, visual, auditory and subcortical networks. Developmental changes in connectivity were observed between the laterobasal nucleus and bilateral ventral temporal and motor cortex as well as between the superficial nuclei and medial thalamus, occipital cortex and a different region of motor cortex. These results show amygdala-subcortical and sensory-cortex connectivity begins refinement prior to childhood, though connectivity changes with associative and frontal cortical areas, seen after early childhood, were not evident in this age range. These findings represent early steps in understanding amygdala network dynamics across infancy through early childhood, an important period of emotional and cognitive development.


Asunto(s)
Amígdala del Cerebelo/crecimiento & desarrollo , Imagen por Resonancia Magnética/métodos , Vías Nerviosas/crecimiento & desarrollo , Preescolar , Estudios Transversales , Femenino , Humanos , Lactante , Estudios Longitudinales , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...