Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
2.
Heart Rhythm ; 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38768842

RESUMEN

The sustained apnea for epicardial access with right ventriculography technique (SAFER epicardial approach) has been previously shown to be effective and safe (1). However, it requires a brief period of unprotected needle dwell time within the pericardium while the operator switches the contrast syringe for a guidewire. This transition period, though brief, raises concerns regarding the potential risk of inadvertent perforation of the right ventricular (RV) wall given the systolic-diastolic excursion of the heart and/or the possibility of losing epicardial access. In an effort to limit the unprotected needle dwell time in the pericardium, we describe the dual operator modified SAFER epicardial approach.

4.
Artículo en Inglés | MEDLINE | ID: mdl-38819345

RESUMEN

BACKGROUND: Catheter ablation of ventricular tachycardia (VT) typically requires radiation exposure with its potential adverse health effects. A completely fluoroless ablation approach is achievable using a combination of electroanatomical mapping and intracardiac echocardiography. Nonetheless, data in patients undergoing VT ablation are limited. OBJECTIVES: This study aimed to determine the feasibility, efficacy, and safety of VT ablation in patients with structural heart disease using a zero-fluoroscopy approach. METHODS: This multicenter study included consecutive patients with ischemic and nonischemic cardiomyopathy undergoing fluoroless VT ablation. Patients requiring epicardial access or coronary angiography were excluded. RESULTS: Between 2017 and 2023 a total of 198 patients (aged 66.4 ± 13.4 years, 76% male, 48% ischemic) were included. Most patients (95.4%) underwent left ventricular (LV) mapping and/or ablation, which was conducted via transseptal route in 54.5% (n = 103), via retrograde aortic route in 43.4% (n = 82), and using a combined approach in 2.1% (n = 4). Two-thirds of patients had a cardiac device, including a biventricular device in 15%; 2 patients had a LV assist device, and 1 patient had a mechanical aortic valve prosthesis. The mean total procedural time was 211 ± 70 minutes, and the total radiofrequency time was 30 ± 22 minutes. During a follow-up period of 22 ± 18 months, the freedom from VT recurrence was 80%, and 7.6% of patients underwent a repeated ablation. Procedural-related complications occurred in 6 patients (3.0%). CONCLUSIONS: Fluoroless ablation of VT in structural heart disease is feasible, effective, and safe when epicardial mapping/ablation is not required.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38668934

RESUMEN

BACKGROUND: Left bundle branch area pacing (LBBAP) has emerged as a physiological alternative pacing strategy to biventricular pacing (BIVP) in cardiac resynchronization therapy (CRT). We aimed to assess the impact of LBBAP vs. BIVP on all-cause mortality and heart failure (HF)-related hospitalization in patients undergoing CRT. METHODS: Studies comparing LBBAP and BIVP for CRT in patients with HF with reduced left ventricular ejection fraction (LVEF) were included. The coprimary outcomes were all-cause mortality and HF-related hospitalization. Secondary outcomes included procedural and fluoroscopy time, change in QRS duration, and change in LVEF. RESULTS: Thirteen studies (12 observational and 1 RCT, n = 3239; LBBAP = 1338 and BIVP = 1901) with a mean follow-up duration of 25.8 months were included. Compared to BIVP, LBBAP was associated with a significant absolute risk reduction of 3.2% in all-cause mortality (9.3% vs 12.5%, RR 0.7, 95% CI 0.57-0.86, p < 0.001) and an 8.2% reduction in HF-related hospitalization (11.3% vs 19.5%, RR 0.6, 95% CI 0.5-0.71, p < 0.00001). LBBAP also resulted in reductions in procedural time (mean weighted difference- 23.2 min, 95% CI - 42.9 to - 3.6, p = 0.02) and fluoroscopy time (- 8.6 min, 95% CI - 12.5 to - 4.7, p < 0.001) as well as a significant reduction in QRS duration (mean weighted difference:- 25.3 ms, 95% CI - 30.9 to - 19.8, p < 0.00001) and a greater improvement in LVEF of 5.1% (95% CI 4.4-5.8, p < 0.001) compared to BIVP in the studies that reported these outcomes. CONCLUSION: In this meta-analysis, LBBAP was associated with a significant reduction in all-cause mortality as well as HF-related hospitalization when compared to BIVP. Additional data from large RCTs is warranted to corroborate these promising findings.

6.
Plants (Basel) ; 13(2)2024 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-38256725

RESUMEN

The reduction in mineral fertilizer usage is crucial to the production of medicinal and aromatic products for safety and health purposes. Presently, nanotechnology and the utilization of natural extracts have been extensively studied due to their significant contribution. Ocimum basilicum is commonly employed for various medicinal and aromatic applications. Therefore, randomized complete block design field experiments containing 10 treatments were conducted during the 2021 and 2022 seasons to investigate the effect of nanoparticles (NPs) of ZnO (1.5 and 2.0 g/L) and SiO2 (100 and 150 mg/L) and date palm pollen extract (DPPE) at 10 and 20 g/L either alone or in combination with the ¾ or ½ NPK recommended dose (RD). The NPK RD was served as a control treatment on basil plant production in each season. The effectiveness of ZnO NPs, SiO2 NPs, and DPPE for the decrease in NPK utilization was evaluated. Meanwhile, the most effective treatment for vegetative traits (except for plant height), essential oil %, and yield was ½ NPK RD + 20 g/L DPPE + 2.0 g/L ZnO NPs. Such a treatment increased the branch number/plant, main stem diameter, relevant chlorophyll content, fresh weight/plant, dry weight/plant, essential oil %, and essential oil yield/plant by 21.00 and 9.94%, 58.70 and 40.00%, 20.69 and 15.83%, 68.83 and 58.28%, 48.70 and 56.16%, 45.71 and 35.53%, and 113.22 and 110.32% over the control in the two seasons, respectively. For total phenol and antioxidant activity, the most effective treatments were the ¾ NPK +1.5 g/L ZnO NPs and ½ NPK +2.0 g/L ZnO NPs, respectively. Simultaneously, essential oil composition (with their compound numbers identified (11-29 for control and ¾ NPK RD + 1.5 g/L ZnO NPs)) and the percentage of total compounds, monoterpene hydrocarbons, sesquiterpene hydrocarbons, and oxygenated hydrocarbons were varied among the used applications. The major observed compounds (>8%) estragole, methyl eugenol, linalool, cineole, and caryophyllene were found in different treatments. Thus, the findings of this study indicate the favorable utilization of ZnO NPs, SiO2 NPs, and DPPE in reducing the application of NPK, which may present a novel strategy and beneficial approach.

7.
J Cardiovasc Electrophysiol ; 35(1): 44-57, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37927196

RESUMEN

BACKGROUND: Intracardiac echocardiography (ICE) is increasingly used during left atrial appendage occlusion (LAAO) as an alternative to transesophageal echocardiography (TEE). The objective of this study is to evaluate the impact of ICE versus TEE guidance during LAAO on procedural characteristics and acute outcomes, as well the presence of peri-device leaks and residual septal defects during follow-up. METHODS: All studies comparing ICE-guided versus TEE-guided LAAO were identified. The primary outcomes were procedural efficacy and occurrence of procedure-related complications. Secondary outcomes included lab efficiency (defined as a reduction in in-room time), procedural time, fluoroscopy time, and presence of peri-device leaks and residual interatrial septal defects (IASD) during follow-up. RESULTS: Twelve studies (n = 5637) were included. There were no differences in procedural success (98.3% vs. 97.8%; OR 0.73, 95% CI 0.42-1.27, p = .27; I2 = 0%) or adverse events (4.5% vs. 4.4%; OR 0.81 95% CI 0.56-1.16, p = .25; I2 = 0%) between the ICE-guided and TEE-guided groups. ICE guidance reduced in in-room time (mean-weighted 28.6-min reduction in in-room time) without differences in procedural time or fluoroscopy time. There were no differences in peri-device leak (OR 0.93, 95% CI 0.68-1.27, p = 0.64); however, an increased prevalence of residual IASD was observed with ICE-guided versus TEE-guided LAAO (46.3% vs. 34.2%; OR 2.23, 95% CI 1.05-4.75, p = 0.04). CONCLUSION: ICE guidance is associated with similar procedural efficacy and safety, but could result in improved lab efficiency (as established by a significant reduction in in-room time). No differences in the rate of periprocedural leaks were found. A higher prevalence of residual interatrial septal defects was observed with ICE guidance.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Ecocardiografía Transesofágica , Resultado del Tratamiento
8.
PLoS One ; 18(11): e0287944, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37939069

RESUMEN

Tilapia Lake Virus (TiLV) is a disease that affects tilapia fish, causing a high rate of sudden death at any stage in their life cycle. Unfortunately, there are currently no effective antiviral drugs or vaccines to prevent or control the progression of this disease. Researchers have discovered that the CRM1 protein plays a critical function in the development and spreading of animal viruses. By inhibiting CRM1, the virus's spread in commercial fish farms can be suppressed. With this in mind, this study intended to identify potential antiviral drugs from two different tropical mangrove plants from tropical regions: Heritiera fomes and Ceriops candolleana. To identify promising compounds that target the CRM1 protein, a computer-aided drug discovery approach is employed containing molecular docking, ADME (absorption, distribution, metabolism and excretion) analysis, toxicity assessment as well as molecular dynamics (MD) simulation. To estimate binding affinities of all phytochemicals, molecular docking is used and the top three candidate compounds with the highest docking scores were selected, which are CID107876 (-8.3 Kcal/mol), CID12795736 (-8.2 Kcal/mol), and CID12303662 (-7.9 Kcal/mol). We also evaluated the ADME and toxicity properties of these compounds. Finally, MD simulation was conducted to analyze the stability of the protein-ligand complex structures and confirm the suitability of these compounds. The computational study demonstrated that the phytochemicals found in H. fomes and C. candolleana could potentially serve as important inhibitors of TiLV, offering practical utility. However, further in vivo investigations are necessary to investigate and potentially confirm the effectiveness of these compounds as antiviral drugs against the virus TiLV.


Asunto(s)
Fármacos Anti-VIH , Enfermedades de los Peces , Tilapia , Virus , Animales , Antivirales/farmacología , Simulación del Acoplamiento Molecular , Enfermedades de los Peces/tratamiento farmacológico , Diseño de Fármacos , Simulación de Dinámica Molecular
10.
Heart Fail Clin ; 19(2): 213-220, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36863813

RESUMEN

COVID-19 infection triggers a heightened inflammatory response which in turn, increases thrombosis and thromboembolism. Microvascular thrombosis has been detected in various tissue beds which may account for some of the multi-system organ dysfunction associated with COVID-19. Additional research is needed to understand which prophylactic and therapeutic drug regimens are best for the prevention and treatment of thrombotic complications of COVID-19.


Asunto(s)
COVID-19 , Tromboembolia , Trombosis , Humanos , COVID-19/complicaciones , Trombosis/tratamiento farmacológico , Trombosis/virología , Tromboembolia/tratamiento farmacológico , Tromboembolia/virología
11.
Card Electrophysiol Clin ; 15(1): 31-37, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36774134

RESUMEN

Idiopathic ventricular arrhythmias (VA), particularly left ventricular outflow tract (LVOT) VA accounts for up to 10% of all VAs referred for ablative therapy. In addition to being infrequent, its intricate anatomy and its pathophysiology make catheter ablation (CA) of these arrhythmias a challenge even for experts. In this scenario, detailed right ventricular outflow tract as well as LVOT electroanatomic mapping including epicardial mapping are essential. In this article, we will emphasize our approach toward the CA technique used for LVOT VA, particularly IVS and/or LVS VA originating from intramural foci, along with its acute and long-term efficacy and safety.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirugía , Ventrículos Cardíacos/cirugía , Arritmias Cardíacas , Mapeo Epicárdico , Ablación por Catéter/métodos , Electrocardiografía , Resultado del Tratamiento
12.
Card Electrophysiol Clin ; 15(1): 75-83, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36774139

RESUMEN

Prolonged use of fluoroscopy during catheter ablation (CA) of arrhythmias is associated with a significant exposure to ionizing radiation and risk of orthopedic injuries given the need for heavy protective equipment. CA of ventricular arrhythmias (VAs) arising from the left ventricular (LV) summit is challenging, requiring a vast knowledge of the intricate cardiac anatomy of this area and careful imaging delineation of the different anatomical structures, which is frequently performed using fluoroscopic guidance. Certain techniques, including pericardial mapping and ablation, use of intracoronary wires, and mapping and ablation inside the coronary venous system have been proposed, further prolonging fluoroscopy time. Fluoroless CA procedures are feasible with currently available technology and appear to have similar safety and efficacy outcomes compared with conventional techniques. To successfully perform fluoroless CA of LV summit arrhythmias, it is important to be fully acquainted with intracardiac echocardiography (ICE) imaging and electroanatomic mapping (EAM). We will describe our approach to perform fluoroless CA in LV summit VAs.


Asunto(s)
Arritmias Cardíacas , Ablación por Catéter , Humanos , Resultado del Tratamiento , Arritmias Cardíacas/diagnóstico por imagen , Arritmias Cardíacas/cirugía , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/cirugía , Corazón , Ablación por Catéter/métodos
14.
Heart Rhythm ; 20(4): 522-529, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36563830

RESUMEN

BACKGROUND: General anesthesia (GA) is the standard anesthetic approach for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. Nonetheless, GA is expensive and can be associated with adverse events. Tumescent local anesthesia (TLA) has been shown to reduce in-room and procedural times and to decrease post-procedural pain, all of which could result in a reduction in procedure-related costs. OBJECTIVE: The purpose of this study is to compare the cost-effectiveness of GA and TLA in patients undergoing S-ICD implantation. METHODS: The present study is a prospective, nonrandomized, controlled study of patients who underwent S-ICD implantation between 2019 and 2022. Patients were allocated to either the TLA or the GA group. We performed a cost analysis for each intervention. As an effectiveness measure, the 0-10 point Numeric Pain Rating Scale at 1, 12, and 24 hours post-implantation was analyzed and compared between the groups. A score of 0 was considered no pain; 1-5, mild pain; 6-7, moderate pain; and 8-10, severe pain. Cost-effectiveness was calculated using incremental cost-effectiveness ratios. RESULTS: Seventy patients underwent successful S-ICD implantation. The total cost of the electrophysiology laboratory was higher in the GA group than in the TLA group (median ± interquartile range US$55,824 ± US$29,411 vs US$37,222 ± US$24,293; P < .001), with a net saving of $20,821 when compared with GA for each S-ICD implantation. There was a significant decrease in post-procedural pain scores in the TLA group when compared with the GA group (repeated measures analysis of variance, P = .009; median ± interquartile range 0 ± 3 vs 0 ± 5 at 1 hour, P = .058; 3 ± 4 vs 6 ± 8 at 12 hours, P = .030; 0 ± 4 vs 2 ± 6 at 24 hours, P = .040). CONCLUSION: TLA is a more cost-effective alternative to GA for S-ICD implantation, with both direct and indirect cost reductions. Importantly, these reduced costs are associated with reduced postprocedural pain.


Asunto(s)
Desfibriladores Implantables , Dolor Asociado a Procedimientos Médicos , Humanos , Anestesia Local , Desfibriladores Implantables/efectos adversos , Estudios Prospectivos , Análisis de Costo-Efectividad , Anestesia General/efectos adversos , Dolor , Resultado del Tratamiento
15.
Europace ; 25(1): 175-184, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-36196043

RESUMEN

AIMS: The aim of this study is to provide guidance for the clinical interpretation of electrocardiograms (ECGs) in prone position and to establish the electroanatomic explanations for the possible differences to supine position ECGs that may be observed. Additionally, to determine if prone back ECG can be used as an alternative to standard ECG in patients who may benefit from prone position. METHODS AND RESULTS: The ECG in supine (standard ECG), prone back (precordial leads placed on the patient's back), and prone anterior position (precordial leads placed in the standard position with the subjects in prone position) were prospectively examined on 85 subjects. Comparisons of ECG parameters between these positions were performed. Computed tomography (CT) scans were performed in both positions to determine possible electroanatomic aetiologies for prone-associated ECG changes. There were significant differences in QRS amplitude in Leads V1-V5 between supine and prone positions. Q waves were more frequently observed in prone back position vs. supine position (V1: 74.1 vs. 10.6%, P < 0.0001; V2: 23.5 vs. 0%, P < 0.0001, respectively). Flat and inverted T waves were more common in prone back leads (V1: 98 vs. 66%, P < 0.0001; V2: 96 vs. 8%, P < 0.0001; V3: 45 vs. 7%, P < 0.0001). The 3D-CT reconstructions measurements corroborated the significant inverse correlation between QRS amplitude and the distance from the centre of the heart to the estimated lead positions. CONCLUSION: In prone back position ECG, low QRS amplitude should not be misinterpreted as low voltage conditions, neither should Q waves and abnormal T waves are considered anteroseptal myocardial infarction. These changes can be explained by an increased impedance (due to interposing lung tissue) and by the increased distance between the electrodes to the centre of the heart.


Asunto(s)
Electrocardiografía , Posicionamiento del Paciente , Humanos , Posición Prona , Estudios Prospectivos , Electrocardiografía/métodos , Corazón
16.
J Korean Neurosurg Soc ; 65(6): 841-845, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36281538

RESUMEN

OBJECTIVE: Chiari III malformations are extremely rare hindbrain malformations that are associated with a high early mortality rate, or severe neurologic deficits in the survivors. The treatment is early operative closure and cerebrospinal fluid diversion (CSF) shunting. METHODS: We operated on 15 patients by repair and excision between July 2014 till June 2020 and retrospective data collection was done. Only one patient doesn't need ventriculoperitoneal (VP) shunt and the other 14 patients need a VP shunt. We described stepwise dissection and untethering of the cerebellum from the bony edge to regrowth and herniation of cerebellum again into this potential space and simple dural closure or repair with graft was done. RESULTS: We started with VP in eight patients (53%) and the other seven patients (46.7%) started with excision and then six patients need VP shunt later on because four patients developed CSF leak and two patients developed increased high intracranial tension. Only four patients (26.7%) needed a blood transfusion. CONCLUSION: There are variations in the outcome and not all cases of Chiari malformation III will die and severe developmental delay is not a must. Proper management and repair carry a good prognosis.

17.
Cardiol Clin ; 40(3): 337-344, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35851457

RESUMEN

COVID-19 infection triggers a heightened inflammatory response which in turn, increases thrombosis and thromboembolism. Microvascular thrombosis has been detected in various tissue beds which may account for some of the multi-system organ dysfunction associated with COVID-19. Additional research is needed to understand which prophylactic and therapeutic drug regimens are best for the prevention and treatment of thrombotic complications of COVID-19.


Asunto(s)
COVID-19 , Trombosis , Anticoagulantes/uso terapéutico , COVID-19/complicaciones , Humanos , SARS-CoV-2 , Trombosis/etiología , Trombosis/prevención & control
18.
J Cardiovasc Electrophysiol ; 33(11): 2356-2366, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35842804

RESUMEN

INTRODUCTION: Increasing evidence has suggested improved outcomes in atrial fibrillation (AF) patients with heart failure (HF) undergoing catheter ablation (CA) as compared to medical therapy. We sought to investigate the benefit of CA on outcomes of patients with AF and HF as compared to medical therapy. METHODS AND RESULTS: A systematic review of PubMed, Embase, and Cochrane Central Register of Clinical Trials was performed for clinical studies evaluating the benefit of CA for patients with AF and HF. Primary endpoint was all-cause mortality. Secondary endpoints included atrial-arrhythmia recurrence and improvement in left ventricular ejection fraction (LVEF). Eight randomized controlled trials were included with a total of 2121 patients (mean age: 65 ± 5 years; 72% male). Mean follow-up duration was 32.9 ± 14.5 months. All-cause mortality in patients who underwent CA was significantly lower than in the medical treatment group (8.8% vs. 13.5%, RR 0.65, 95% confidence interval [CI] 0.51-0.83, p = .0005). A 35% relative risk reduction and 4.7% absolute risk reduction in all-cause mortality was observed with CA. Rates of all-atrial arrhythmia recurrence were significantly lower in the CA group (39.9% vs. 69.6%, RR: 0.55, 95% CI: 0.40-0.76, p = .0003). Improvement in LVEF was significantly higher in patients undergoing CA (+9.4 ± 7.6%) as compared to conventional treatment (+3.3 ± 8%) (mean difference 6.2, 95% CI: 3.6-8.8, p < .00001). CONCLUSION: CA for AF in patients with HF decreases all-cause mortality, improves all-atrial arrhythmia recurrence rate and LVEF when compared to medical management. CA should be considered the treatment of choice to improve survival in this select group of patients. Nonetheless, the benefit of CA in patients with severely reduced ejection fraction and New York Heart Association class IV HF has not been clearly elucidated.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Insuficiencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Volumen Sistólico , Antiarrítmicos/efectos adversos , Función Ventricular Izquierda , Resultado del Tratamiento , Ensayos Clínicos Controlados Aleatorios como Asunto , Ablación por Catéter/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia
20.
Card Electrophysiol Clin ; 14(1): 63-70, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35221086

RESUMEN

Numerous systemic manifestations, including cardiac involvement in the form of myocardial infarction, myocarditis, and electrocardiographic changes, have been associated with COVID-19..In this review, the authors describe the electrocardiographic features that have been reported to date in patients affected by this disease and their possible underlying mechanisms.


Asunto(s)
COVID-19 , Infarto del Miocardio , Miocarditis , Electrocardiografía , Humanos , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...