Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Adv Biol (Weinh) ; : e2300511, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39123296

RESUMEN

The average cost to bring a new drug from its initial discovery to a patient's bedside is estimated to surpass $2 billion and requires over a decade of research and development. There is a need for new drug screening technologies that can parse drug candidates with increased likelihood of clinical utility early in development in order to increase the cost-effectiveness of this pipeline. For example, during the COVID-19 pandemic, resources were rapidly mobilized to identify effective therapeutic treatments but many lead antiviral compounds failed to demonstrate efficacy when progressed to human trials. To address the lack of predictive preclinical drug screening tools, PREDICT96-ALI, a high-throughput (n = 96) microphysiological system (MPS)  that recapitulates primary human tracheobronchial tissue,is adapted for the evaluation of differential antiviral efficacy of native SARS-CoV-2 variants of concern. Here, PREDICT96-ALI resolves both the differential viral kinetics between variants and the efficacy of antiviral compounds over a range of drug doses. PREDICT96-ALI is able to distinguish clinically efficacious antiviral therapies like remdesivir and nirmatrelvir from promising lead compounds that do not show clinical efficacy. Importantly, results from this proof-of-concept study track with known clinical outcomes, demonstrate the feasibility of this technology as a prognostic drug discovery tool.

2.
Cells ; 12(22)2023 11 16.
Artículo en Inglés | MEDLINE | ID: mdl-37998374

RESUMEN

COVID-19 emerged as a worldwide pandemic in early 2020, and while the rapid development of safe and efficacious vaccines stands as an extraordinary achievement, the identification of effective therapeutics has been less successful. This process has been limited in part by a lack of human-relevant preclinical models compatible with therapeutic screening on the native virus, which requires a high-containment environment. Here, we report SARS-CoV-2 infection and robust viral replication in PREDICT96-ALI, a high-throughput, human primary cell-based organ-on-chip platform. We evaluate unique infection kinetic profiles across lung tissue from three human donors by immunofluorescence, RT-qPCR, and plaque assays over a 6-day infection period. Enabled by the 96 devices/plate throughput of PREDICT96-ALI, we also investigate the efficacy of Remdesivir and MPro61 in a proof-of-concept antiviral study. Both compounds exhibit an antiviral effect against SARS-CoV-2 in the platform. This demonstration of SARS-CoV-2 infection and antiviral dosing in a high-throughput organ-on-chip platform presents a critical capability for disease modeling and therapeutic screening applications in a human physiology-relevant in vitro system.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Antivirales/farmacología , Pulmón , Replicación Viral
3.
Sci Rep ; 11(1): 12225, 2021 06 09.
Artículo en Inglés | MEDLINE | ID: mdl-34108507

RESUMEN

Microphysiological organ-on-chip models offer the potential to improve the prediction of drug safety and efficacy through recapitulation of human physiological responses. The importance of including multiple cell types within tissue models has been well documented. However, the study of cell interactions in vitro can be limited by complexity of the tissue model and throughput of current culture systems. Here, we describe the development of a co-culture microvascular model and relevant assays in a high-throughput thermoplastic organ-on-chip platform, PREDICT96. The system consists of 96 arrayed bilayer microfluidic devices containing retinal microvascular endothelial cells and pericytes cultured on opposing sides of a microporous membrane. Compatibility of the PREDICT96 platform with a variety of quantifiable and scalable assays, including macromolecular permeability, image-based screening, Luminex, and qPCR, is demonstrated. In addition, the bilayer design of the devices allows for channel- or cell type-specific readouts, such as cytokine profiles and gene expression. The microvascular model was responsive to perturbations including barrier disruption, inflammatory stimulation, and fluid shear stress, and our results corroborated the improved robustness of co-culture over endothelial mono-cultures. We anticipate the PREDICT96 platform and adapted assays will be suitable for other complex tissues, including applications to disease models and drug discovery.


Asunto(s)
Comunicación Celular , Técnicas de Cocultivo/métodos , Dermis/metabolismo , Endotelio Vascular/metabolismo , Técnicas Analíticas Microfluídicas/métodos , Pericitos/metabolismo , Retina/metabolismo , Permeabilidad de la Membrana Celular , Células Cultivadas , Dermis/citología , Endotelio Vascular/citología , Humanos , Pericitos/citología , Retina/citología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA