Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Innovations (Phila) ; 18(4): 331-337, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37534404

RESUMEN

OBJECTIVE: Transventricular beating-heart mitral valve repair (TBMVR) with artificial chordae implantation is a technique to treat mitral valve prolapse. Two-dimensional (2D) echocardiography completed with simultaneous biplane view during surgeon finger pushing on the left ventricular (LV) wall (finger test [FT]) is currently used to localize the desired LV access, on the inferior-lateral wall, between the papillary muscles (PMs). We aimed to compare a new three-dimensional (3D) method with conventional FT in terms of safety and better localization of LV access. METHODS: During TBMVR, conventional FT was completed using 3D transesophageal echocardiography by placing the sample box in the bicommissural view of the LV, including the PMs and the apex. The 3D volume was subsequently edited to visualize the LV from above (surgical view) to localize the bulge of the operator's finger pushing on the LV. We asked the first operator, the second operator, and the cardiac surgery fellow, separately, to evaluate the location of their finger pushing, both with the 2D method and the 3D method, to estimate the interoperator concordance. RESULTS: From 2019 to 2021, 42 TBMVRs were performed without complications related to access using FT completed with the 3D method. Regarding the choice of the right and safe entry site, the operator's agreement was higher using 3D rendering compared with conventional FT (mean agreement 0.59 ± 0.29 for 2D vs 0.83 ± 0.20 for 3D), while full operator agreement was 10 of 42 for 2D and 23 of 42 for 3D (P = 0.004). CONCLUSIONS: Three-dimensional FT is easy to perform and facilitates surgeons choosing the best access for TBMVR in term of anatomical localization and safety.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Ecocardiografía , Prolapso de la Válvula Mitral/cirugía , Ecocardiografía Transesofágica/métodos , Ecocardiografía Tridimensional/métodos
2.
Medicina (Kaunas) ; 59(6)2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37374220

RESUMEN

Sex-related disparities have been recognized in incidence, pathological findings, pathophysiological mechanisms, and diagnostic pathways of non-rheumatic mitral regurgitation. Furthermore, access to treatments and outcomes for surgical and interventional therapies among women and men appears to be different. Despite this, current European and US guidelines have identified common diagnostic and therapeutic pathways that do not consider patient sex in decision-making. The aim of this review is to summarize the current evidence on sex-related differences in non-rheumatic mitral regurgitation, particularly regarding incidence, imaging modalities, surgical-derived evidence, and outcomes of transcatheter edge-to-edge repair, with the goal of informing clinicians about sex-specific challenges to consider when making treatment decisions for patients with mitral regurgitation.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Femenino , Masculino , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Caracteres Sexuales , Cateterismo Cardíaco/métodos , Resultado del Tratamiento
3.
J Clin Med ; 12(5)2023 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-36902543

RESUMEN

The NeoChord procedure is an echo-guided trans-ventricular beating-heart mitral valve repair technique to treat degenerative mitral regurgitation (MR) due to prolapse and/or flail. The aim of this study is to analyze echocardiographic images to find pre-operative parameters to predict procedural success (≤moderate MR) at 3-year follow-up. Seventy-two consecutive patients with severe MR underwent the NeoChord procedure between 2015 and 2021. MV pre-operative morphological parameters were assessed using 3D transesophageal echocardiography with dedicated software (QLAB, Philips). Three patients died during their hospitalization. The remaining 69 patients were retrospectively analyzed. At follow-up, MR > moderate was found in 17 patients (24.6%). In the univariate analysis, end-systolic annulus area (12.5 ± 2.5 vs. 14.1 ± 2.6 cm2; p = 0.038), end-systolic annulus circumference (13.2 ± 1.2 vs. 14 ± 1.3 cm; p = 0.042), indexed left atrial volume (59 ± 17 vs. 76 ± 7 mL/m2; p = 0.041), and AF (25% vs. 53%; p = 0.042) were lower in the 52 patients with ≤ MR compared to those with > moderate MR. Annular dysfunction parameters were the best predictors of procedural success: 3D early-systolic annulus area (AUC 0.74; p = 0.004), 3D early-systolic annulus circumference (AUC 0.75; p = 0.003), and 3D annulus area fractional change (AUC 0.73; p = 0.035). Patient selection relying on 3D dynamic and static MA dimensions may improve the maintenance of procedural success at follow-up.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...