Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(5)2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38475248

RESUMEN

Silicon photonic sensors based on Mach Zehnder Interferometers (MZIs) have applications spanning from biological and olfactory sensors to temperature and ultrasound sensors. Although a coherent detection scheme can solve the issues of sensitivity fading and ambiguity in phase direction, the measured phase remains 2π periodic. This implies that the acquisition frequency should ensure a phase shift lower than π between each measurement point to prevent 2π phase jumps. Here, we describe and experimentally characterize two methods based on reference MZIs with lower sensitivities to alleviate this drawback. These solutions improve the measurement robustness and allow the lowering of the acquisition frequency. The first method is based on the phase derivative sign comparison. When a discrepancy is detected, the reference MZI is used to choose whether 2π should be added or removed from the nominal MZI. It can correct 2π phase jumps regardless of the sensitivity ratio, so that a single reference MZI can be used to correct multiple nominal MZIs. This first method relaxes the acquisition frequency requirement by a factor of almost two. However, it cannot correct phase jumps of 4π, 6π or higher between two measurement points. The second method is based on the comparison between the measured phase from the nominal MZI and the phase expected from the reference MZI. It can correct multiple 2π phase jumps but requires at least one reference MZI per biofunctionalization. It will also constrain the corrected phase to lie in a limited interval of [-π, +π] around the expected value, and might fail to correct phase shifts above a few tens of radians depending on the disparity of the nominal sensors responses. Nonetheless, for phase shift lower than typically 20 radians, this method allows the lowering of the acquisition frequency almost arbitrarily.

2.
Opt Express ; 30(19): 33955-33968, 2022 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-36242419

RESUMEN

Silicon photonics can address a variety of applications, from datacom and biosensing to lidars. Recently, this technology has been explored for gas sensing. Detection and identification of odors remains a critical challenge in diverse areas such as air quality, food spoilage, or personal well-being. In this work, we present an olfactory sensor based on an array of 64 biofunctionalized Mach-Zehnder interferometers integrated on a silicon nitride platform. The ability to analyze odors at ppm level is demonstrated for several volatile organic compounds.


Asunto(s)
Técnicas Biosensibles , Compuestos Orgánicos Volátiles , Interferometría , Óptica y Fotónica , Fotones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA