Nat Commun ; 15(1): 1588, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-38383659

RESUMEN

High performance X-ray detector with ultra-high spatial and temporal resolution are crucial for biomedical imaging. This study reports a dynamic direct-conversion CMOS X-ray detector assembled with screen-printed CsPbBr3, whose mobility-lifetime product is 5.2 × 10-4 cm2 V-1 and X-ray sensitivity is 1.6 × 104 µC Gyair-1 cm-2. Samples larger than 5 cm[Formula: see text]10 cm can be rapidly imaged by scanning this detector at a speed of 300 frames per second along the vertical and horizontal directions. In comparison to traditional indirect-conversion CMOS X-ray detector, this perovskite CMOS detector offers high spatial resolution (5.0 lp mm-1) X-ray radiographic imaging capability at low radiation dose (260 nGy). Moreover, 3D tomographic images of a biological specimen are also successfully reconstructed. These results highlight the perovskite CMOS detector's potential in high-resolution, large-area, low-dose dynamic biomedical X-ray and CT imaging, as well as in non-destructive X-ray testing and security scanning.