Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
JACC Cardiovasc Interv ; 16(5): 558-570, 2023 03 13.
Artículo en Inglés | MEDLINE | ID: mdl-36922042

RESUMEN

BACKGROUND: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation. OBJECTIVES: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves. METHODS: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker. Sites follow a standardized TAVR care pathway, including early discharge and a conduction disturbance management algorithm, and transfemoral deployment using the COT. RESULTS: A total of 400 attempted implants from the United States and Canada comprised the main cohort of this second interim analysis. The mean age was 78.7 ± 6.6 years, and the mean Society of Thoracic Surgeons predictive risk of mortality was 3.0 ± 2.4. The median length of stay was 1 day. There were no instances of moderate or severe AR at discharge. At 30 days, all-cause mortality or stroke was 3.8%, all-cause mortality was 0.8%, disabling stroke was 0.7%, hospital readmission was 10.1%, and cardiovascular rehospitalization was 6.1%. The new PPI rate was 9.8%, 5.8% with 4-step COT compliance. In the multivariable model, right bundle branch block and the depth of the implant increased the risk of PPI, whereas using the 4-step COT lowered 30-day PPI. CONCLUSIONS: The use of the TAVR care pathway and COT resulted in favorable clinical outcomes with no moderate or severe AR and low PPI rates at 30 days while facilitating early discharge and reproducible outcomes across various sites and operators. (Optimize PRO; NCT04091048).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estados Unidos , Anciano , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Vías Clínicas , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/etiología , Prótesis Valvulares Cardíacas/efectos adversos
2.
JACC Cardiovasc Interv ; 12(13): 1217-1226, 2019 07 08.
Artículo en Inglés | MEDLINE | ID: mdl-31272667

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the safety and efficacy of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) for stentless bioprosthetic aortic valves (SBAVs) and to identify predictors of adverse events. BACKGROUND: ViV TAVR in SBAVs is associated with unique technical challenges and risks. METHODS: Clinical records and computer tomographic scans were retrospectively reviewed for procedural complications, predictors of coronary obstruction, mortality, and echocardiographic results. RESULTS: Among 66 SBAV patients undergoing ViV TAVR, mortality was 2 of 66 patients (3.0%) at 30 days and 5 of 52 patients (9.6%) at 1 year. At 1 year, left ventricular end-systolic dimension was decreased versus baseline (median [interquartile range (IQR)]: 3.0 [2.6 to 3.6] cm vs. 3.7 [3.2 to 4.4] cm; p < 0.001). Coronary occlusion in 6 of 66 procedures (9.1%) resulted in myocardial infarction in 2 of 66 procedures (3.0%). Predictors of coronary occlusion included subcoronary implant technique compared with full root replacement (6 of 31, 19.4% vs. 0 of 28, 0%; p = 0.01), short simulated radial valve-to-coronary distance (median [IQR]: 3.4 [0.0 to 4.6] mm vs. 4.6 [3.2 to 6.2] mm; p = 0.016), and low coronary height (7.8 [5.8 to 10.0] mm vs. 11.6 [8.7 to 13.9] mm; p = 0.003). Coronary arteries originated <10 mm above the valve leaflets in 34 of 97 unobstructed coronary arteries (35.1%). CONCLUSIONS: TAVR in SBAVs is frequently associated with high-risk coronary anatomy but can be performed with a low risk of death and myocardial infarction, resulting in favorable ventricular remodeling. A subcoronary surgical approach is associated with an increased risk of coronary obstruction.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Falla de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Oclusión Coronaria/etiología , Bases de Datos Factuales , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Diseño de Prótesis , Recuperación de la Función , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Estados Unidos
3.
Environ Res ; 142: 374-9, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26209764

RESUMEN

BACKGROUND: Previously, we reported a 18% increased odds of ST-elevation myocardial infarction (STEMI) associated with each 7.1 µg/m(3) increase in PM2.5 concentration in the hour prior to MI onset. We found no association with non-ST elevation myocardial infarction (NSTEMI). We examined if this association was modified by PM2.5 source direction. METHODS: We used the NOAA HYbrid Single-Particle Lagrangian Trajectory (HYSPLIT) model to calculate each hourly air mass location for the 24 hours before each case or control time period in our previous PM2.5/STEMI case-crossover analysis. Using these data on patients with STEMI (n=338), hourly PM2.5 concentrations, and case-crossover methods, we evaluated whether our PM2.5/STEMI association was modified by whether the air mass passed through each of the 8 cardinal wind direction sectors in the previous 24h. RESULTS: When the air mass passed through the West-Southwest direction (WSW) any time in the past 24h, the odds of STEMI associated with each 7.1µg/m(3) increase in PM2.5 concentration in the previous hour (OR=1.27; 95% CI=1.08, 1.22) was statistically significantly (p=0.01) greater than the relative odds of STEMI associated with increased PM2.5 concentration when the wind arrived from any other direction (OR=0.99; 95% CI=0.80, 1.22). We found no other effect modification by any other source direction. Further, relative odds estimates were largest when the time spent in the WSW was 8-16 h, compared to ≤7 h or 17-24 h, suggesting that particles arising from sources in this direction were more potent in triggering STEMIs. CONCLUSIONS: Since relative odds estimates were higher when the air mass passed through the WSW octant in the past 24h, there may be specific components of the ambient aerosol that are more potent in triggering STEMIs. This direction is associated with substantial emissions from coal-fired power plants and other industrial sources of the Ohio River Valley, many of which are undergoing modifications to reduce their emissions.


Asunto(s)
Contaminantes Atmosféricos/análisis , Infarto del Miocardio/epidemiología , Infarto del Miocardio/etiología , Material Particulado/análisis , Viento , Aerosoles , Anciano , Anciano de 80 o más Años , Contaminantes Atmosféricos/efectos adversos , Estudios de Casos y Controles , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Estadísticos , New York/epidemiología , Oportunidad Relativa , Tamaño de la Partícula , Material Particulado/efectos adversos , Factores de Riesgo
4.
Part Fibre Toxicol ; 11: 1, 2014 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-24382024

RESUMEN

BACKGROUND: We and others have shown that increases in particulate air pollutant (PM) concentrations in the previous hours and days have been associated with increased risks of myocardial infarction, but little is known about the relationships between air pollution and specific subsets of myocardial infarction, such as ST-elevation myocardial infarction (STEMI) and non ST-elevation myocardial infarction (NSTEMI). METHODS: Using data from acute coronary syndrome patients with STEMI (n = 338) and NSTEMI (n = 339) and case-crossover methods, we estimated the risk of STEMI and NSTEMI associated with increased ambient fine particle (<2.5 um) concentrations, ultrafine particle (10-100 nm) number concentrations, and accumulation mode particle (100-500 nm) number concentrations in the previous few hours and days. RESULTS: We found a significant 18% increase in the risk of STEMI associated with each 7.1 µg/m³ increase in PM2.5 concentration in the previous hour prior to acute coronary syndrome onset, with smaller, non-significantly increased risks associated with increased fine particle concentrations in the previous 3, 12, and 24 hours. We found no pattern with NSTEMI. Estimates of the risk of STEMI associated with interquartile range increases in ultrafine particle and accumulation mode particle number concentrations in the previous 1 to 96 hours were all greater than 1.0, but not statistically significant. Patients with pre-existing hypertension had a significantly greater risk of STEMI associated with increased fine particle concentration in the previous hour than patients without hypertension. CONCLUSIONS: Increased fine particle concentrations in the hour prior to acute coronary syndrome onset were associated with an increased risk of STEMI, but not NSTEMI. Patients with pre-existing hypertension and other cardiovascular disease appeared particularly susceptible. Further investigation into mechanisms by which PM can preferentially trigger STEMI over NSTEMI within this rapid time scale is needed.


Asunto(s)
Contaminantes Atmosféricos/toxicidad , Electrocardiografía/efectos de los fármacos , Infarto del Miocardio/inducido químicamente , Material Particulado/toxicidad , Síndrome Coronario Agudo/inducido químicamente , Síndrome Coronario Agudo/patología , Factores de Edad , Anciano , Anciano de 80 o más Años , Índice de Masa Corporal , Estudios de Casos y Controles , Intervalos de Confianza , Estudios Cruzados , Interpretación Estadística de Datos , Etnicidad , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/patología , New York , Estudios Prospectivos , Proyectos de Investigación , Volumen Sistólico , Resultado del Tratamiento , Tiempo (Meteorología)
5.
Cardiovasc Ultrasound ; 7: 38, 2009 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-19689809

RESUMEN

BACKGROUND: Although echocardiography is commonly used to evaluate cardiac function after MI, CMR may provide more accurate functional assessment but has not been adequately compared with echo. The primary study objective was to compare metrics of left ventricular volumes and global and regional function determined by cardiac magnetic resonance (CMR) and echocardiography (echo) in patients (pts) with recent myocardial infarction (MI). METHODS: To compare CMR with echo, 47 consecutive patients (pts 70% male; mean age = 66 +/- 11 years) with MI >6 wks previously and scheduled for imaging evaluation were studied by both echo and CMR within 60 min of each other. Readers were blinded to pt information. Pearson's correlation coefficient, paired t-tests, and chi-square tests were used to compare CMR and echo measures. Further comparisons were made between pts and 30 normal controls for CMR and between pts and published normal ranges for echo. RESULTS: Measures of volume and function correlated moderately well between CMR and echo (r = 0.54 to 0.75, all p < 0.001), but large and systematic differences were noted in absolute measurements. Echo underestimated left ventricular (LV) volumes (by 69 ml for end-diastolic, 35 ml for end-systolic volume, both p < 0.001), stroke volume (by 34 ml, p < 0.001), and LV ejection fraction (LVEF) (by 4 percentage point, p = 0.02). CMR was much more sensitive to detection of segmental wall motion abnormalities (p < 0.001). CMR comparisons with normal controls confirmed an increase in LV volumes, a decrease in LVEF, and preservation of stroke volume after MI. CONCLUSION: This intra subject comparison after MI found large, systematic differences between CMR and echo measures of volumes, LVEF, and wall motion abnormality despite moderate inter-modality correlations, with echo underestimating each metric. CMR also provided superior detection and quantification of segmental function after MI. Serial studies of LV function in individual patients should use the same modality.


Asunto(s)
Volumen Cardíaco , Ecocardiografía/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Anciano , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...