Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Analyst ; 126(8): 1221-8, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11534584

RESUMEN

In this paper we demonstrate the feasibility of ultra-trace resonance enhanced multiphoton ionization (REMPI) detection employing a small broad-bandwidth solid state laser system. The results reported here are compared with measurements carried out with a conventional excimer pumped dye laser combination. Mass selected broad-bandwidth REMPI spectra for the environmentally relevant nitrogen oxides NO and NO2 are presented. Tunable broad-bandwidth laser radiation with a spectral resolution of > 10 cm(-1) in the wavelength range 560-400 nm was employed for the detection of NO2. For NO detection, the range 230-224 nm was covered. Laser radiation was generated using an optical parametric oscillator pumped by an unseeded Nd:YAG laser. A mobile time-of-flight mass spectrometer equipped with an atmospheric pressure laser ionization source allowed for mass selective parent ion detection at m/z 30 for NO and m/z 46 for NO2. The limit of detection was 10 pptV for NO and 20 pptV for NO2. A selectivity of > 2000 for both compounds with respect to N2O5, organic nitrates and NO2 in the case of NO is reported. An improved laser system currently under construction is expected to provide detection limits below pptv mixing ratios for both nitrogen oxides in a 20 s integration interval.


Asunto(s)
Contaminantes Ambientales/análisis , Óxido Nítrico/análisis , Dióxido de Nitrógeno/análisis , Espectrometría de Masas/métodos
2.
Anal Chem ; 72(22): 5639-46, 2000 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-11101242

RESUMEN

We report on the development of a quasi-simultaneous highly selective method for NO and NO2 detection at the ultratrace level. Atmospheric pressure laser ionization (APLI), recently introduced by our group, is used to detect both compounds at low parts per trillion by volume (pptv) mixing ratios. APLI is based on resonance-enhanced multiphoton ionization mass spectrometry. Two-color pump-probe experiments employing a single excimer pumped dye laser combination allow for the ultrasensitive measurement of NO and NO2 within a narrow range of maximum pumping efficiency of the laser dye Coumarin 120. NO is detected via excitation of the long-lived A 2sigma+ (nu' = 1) level at 215.36 nm and subsequently ionized with 308-nm radiation provided by the excimer pump laser. NO2 is ionized after double resonant excitation of the A2B1 and 3psigma manifolds in a (1 + 1' + 1(')) process using 431.65 + 308 nm. The selectivity of the NO measurement exceeds 2,000 with respect to NO2 and N2O5. For NO2, a selectivity of >3,000 with respect to N2O5 and organic nitrates is observed. The current APLI detection limit of NO and NO2 is 0.5 and 5 pptv, respectively, with a 20-s integration time.

3.
Anal Chem ; 71(17): 3721-9, 1999 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-21662879

RESUMEN

In this contribution a new analytical technique is presented for the direct mass spectrometric (MS) detection of gas-phase trace species at atmospheric pressure. Employing resonance-enhanced multiphoton ionization (REMPI) close to the inlet nozzle orifice, i.e., at high molecule densities, the sensitivity of the instrument has been increased by up to 3 orders of magnitude as compared to conventional REMPI-MS with ionization in a differentially coupled ion source. Furthermore, adiabatic cooling, resonant ionization, and mass-selective detection establish a highly selective analytical technique. Several atmospherically relevant compounds were investigated. The current detection limit for NO is 0.9 pptv, for acetaldehyde 1.7 pptv, for CO 15 pptv, and for 2,5-dichlorotoluene 12 pptv. We discuss APLI with regard to applications in medical and environmental research.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA