Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Bioinspir Biomim ; 16(3)2021 03 19.
Artículo en Inglés | MEDLINE | ID: mdl-33530070

RESUMEN

This study examined natural composite structures within the remarkably strong exoskeleton of the southwestern ironclad beetle (Z. haldemani). Structural and nanomechanical analyses revealed that the exoskeleton's extraordinary resistance to external forces is provided by its exceptional thickness and multi-layered structure, in which each layer performed a distinct function. In detail, the epicuticle, the outmost layer, comprised 3%-5% of the overall thickness with reduced Young's moduli of 2.2-3.2 GPa, in which polygonal-shaped walls (2-3µm in diameter) were observed on the surface. The next layer, the exocuticle, consisted of 17%-20% of the total thickness and exhibited the greatest Young's moduli (∼15 GPa) and hardness (∼800 MPa) values. As such, this layer provided the bulk of the mechanical strength for the exoskeleton. While the endocuticle spanned 70%-75% of the total thickness, it contained lower moduli (∼8-10 GPa) and hardness (∼400 MPa) values than the exocuticle. Instead, this layer may provide flexibility through its specifically organized chitin fiber layers, known as Bouligand structures. Nanoindentation testing further reiterated that the various fibrous layer orientations resulted in different elastic moduli throughout the endocuticle's cross-section. Additionally, this exoskeleton prevented delamination within the composite materials by overlapping approximately 5%-19% of each fibrous stack with neighboring layers. Finally, the innermost layer, the epidermis contributing 5%-7 % of the total thickness, contains attachment sites for muscle and soft tissue that connect the exoskeleton to the beetle. As such, it is the softest region with reduced Young's modulus of ∼2-3 GPa and hardness values of ∼290 MPa. These findings can be applied to the development of innovative, fiber-reinforced composite materials.


Asunto(s)
Escarabajos , Dispositivo Exoesqueleto , Animales , Módulo de Elasticidad , Dureza
2.
Front Microbiol ; 9: 2028, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30210488

RESUMEN

A small percentage of babies born to Zika virus (ZIKV)-infected mothers manifest severe defects at birth, including microcephaly. Among those who appeared healthy at birth, there are increasing reports of postnatal growth or developmental defects. However, the impact of congenital ZIKV infection in postnatal development is poorly understood. Here, we report that a mild congenital ZIKV-infection in pups born to immunocompetent pregnant mice did not display apparent defects at birth, but manifested postnatal growth impediments and neurobehavioral deficits, which include reduced locomotor and cognitive deficits that persisted into adulthood. We found that the brains of these pups were smaller, had a thinner cortical layer 1, displayed increased astrogliosis, decreased expression of microcephaly- and neuron development- related genes, and increased pathology as compared to mock-infected controls. In summary, our results showed that even a mild congenital ZIKV infection in immunocompetent mice could lead to postnatal deficits, providing definitive experimental evidence for a necessity to closely monitor postnatal growth and development of presumably healthy human infants, whose mothers were exposed to ZIKV infection during pregnancy.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...