Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 138
Filtrar
1.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38696701

RESUMEN

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Puntaje de Propensión , Sistema de Registros , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Factores Sexuales , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Arritmias Cardíacas/terapia , Medición de Riesgo , Europa (Continente) , Factores de Tiempo , Muerte Súbita Cardíaca/prevención & control
2.
Artículo en Inglés | MEDLINE | ID: mdl-38652395

RESUMEN

We present a case of a young patient with chest pain. Labs and cardiac imaging were suspicious for acute myocarditis. Genetic testing revealed a diagnosis of desmoplakin cardiomyopathy. Desmoplakin cardiomyopathy may be considered in patients with recurrent acute myocarditis or a family history of cardiac disease to avoid the potential for misdiagnosis.

3.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584394

RESUMEN

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cardioversión Eléctrica/efectos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
4.
J Clin Med ; 13(5)2024 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-38592178

RESUMEN

Although mitral valve prolapse (MVP) is the most prevalent valvular abnormality in Western countries and generally carries a good prognosis, a small subset of patients is exposed to a significant risk of malignant ventricular arrhythmias (VAs) and sudden cardiac death (SCD), the so-called arrhythmic MVP (AMVP) syndrome. Recent work has emphasized phenotypical risk features of severe AMVP and clarified its pathophysiology. However, the appropriate assessment and risk stratification of patients with suspected AMVP remains a clinical conundrum, with the possibility of both overestimating and underestimating the risk of malignant VAs, with the inappropriate use of advanced imaging and invasive electrophysiology study on one hand, and the catastrophic occurrence of SCD on the other. Furthermore, the sports eligibility assessment of athletes with AMVP remains ill defined, especially in the grey zone of intermediate arrhythmic risk. The definition, epidemiology, pathophysiology, risk stratification, and treatment of AMVP are covered in the present review. Considering recent guidelines and expert consensus statements, we propose a comprehensive pathway to facilitate appropriate counseling concerning the practice of competitive/leisure-time sports, envisioning shared decision making and the multidisciplinary "sports heart team" evaluation of borderline cases. Our final aim is to encourage an active lifestyle without compromising patients' safety.

5.
J Clin Med ; 13(7)2024 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-38610635

RESUMEN

There are no investigations about the outcomes of idiopathic PVC catheter ablation (CA) in athletes compared to the sedentary population. We conducted a prospective single-centre observational study. The primary and secondary procedural outcomes were the post-ablation reduction of premature ventricular contractions (PVCs) in an athletes vs. non-athletes group and in agonist vs. leisure-time athletes. The third was the evaluation of the resumption of physical activity and the improvement of symptoms in agonist and leisure-time athletes. From January 2020 to October 2022 we enrolled 79 patients with RVOT/LVOT/fascicular PVC presumed origin. The median percentage of decrease between the pre-procedure and post-procedure Holter monitoring in the non-athletes group was 96 (IQR 68-98) and 98 in the athletes group (IQR 92-99) (p = 0.08). Considering the athletes, the median percentage of decrease in the number of PVCs was 98 (IQR 93-99) and 98 (IQR 87-99), respectively, in leisure-time and agonistic athletes (p = 0.42). Sixteen (70%) leisure time and seventeen (90%) agonist athletes (p = 0.24) have resumed physical activity 3 months after PVC CA; among agonistic athletes, 59% have resumed competitive physical activity. Many leisure-time (88%) and agonist (70%) athletes experienced an improvement in symptoms after ablation. PVC CA was effective and safe in both groups, reducing symptoms and allowing a quick and safe return to sports activities in athletes.

6.
Heart Rhythm ; 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38432424

RESUMEN

BACKGROUND: Leadless pacemakers (LPs) capable of VDD pacing allow for atrioventricular synchrony through mechanical sensing of atrial contraction. However, mechanical sensing is less reliable and less predictable than electrical sensing. OBJECTIVE: The purpose of this study was to evaluate P-wave amplitude during sinus rhythm from preoperative 12-lead electrocardiograms (ECGs) as a predictor for atrial mechanical sensing in patients undergoing VDD LP implantation. METHODS: Consecutive patients undergoing VDD LP implantation were included in this 2-center prospective cohort study. ECG parameters were evaluated separately and in combination for association with the signal amplitude of atrial mechanical contraction (A4). RESULTS: Eighty patients (median age 82 years; female 55%; mean body mass index [BMI] 25.8 kg/m2) were included in the study and 61 patients in the A4 signal analysis (19 patients in VVI mode during follow-up). Absolute (aVL, aVF, V1, V2) and BMI-adjusted (I, II, aVL, aVF, aVR, V1, V2) P-wave amplitudes from baseline ECGs demonstrated a statistically significant positive correlation with A4 signal amplitude (all P <.05). A combined P-wave signal amplitude of at least 0.2 mV in V1 and aVL was predictive, with specificity of 83% (95% confidence interval 67%-100%) for A4 signal ≥1 m/s2. We found a significant correlation of A4 signal amplitude and overall atrioventricular synchrony (P = .013). CONCLUSION: P-wave amplitudes in ECG leads aVL and V1 can predict A4 signal amplitude in patients with VDD LP and therefore the probability of successful AV synchronous pacing.

8.
Eur Heart J ; 45(7): 538-548, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38195003

RESUMEN

BACKGROUND AND AIMS: Implantable cardioverter-defibrillators (ICDs) are critical for preventing sudden cardiac death (SCD) in arrhythmogenic right ventricular cardiomyopathy (ARVC). This study aims to identify cross-continental differences in utilization of primary prevention ICDs and survival free from sustained ventricular arrhythmia (VA) in ARVC. METHODS: This was a retrospective analysis of ARVC patients without prior VA enrolled in clinical registries from 11 countries throughout Europe and North America. Patients were classified according to whether they received treatment in North America or Europe and were further stratified by baseline predicted VA risk into low- (<10%/5 years), intermediate- (10%-25%/5 years), and high-risk (>25%/5 years) groups. Differences in ICD implantation and survival free from sustained VA events (including appropriate ICD therapy) were assessed. RESULTS: One thousand ninety-eight patients were followed for a median of 5.1 years; 554 (50.5%) received a primary prevention ICD, and 286 (26.0%) experienced a first VA event. After adjusting for baseline risk factors, North Americans were more than three times as likely to receive ICDs {hazard ratio (HR) 3.1 [95% confidence interval (CI) 2.5, 3.8]} but had only mildly increased risk for incident sustained VA [HR 1.4 (95% CI 1.1, 1.8)]. North Americans without ICDs were at higher risk for incident sustained VA [HR 2.1 (95% CI 1.3, 3.4)] than Europeans. CONCLUSIONS: North American ARVC patients were substantially more likely than Europeans to receive primary prevention ICDs across all arrhythmic risk strata. A lower rate of ICD implantation in Europe was not associated with a higher rate of VA events in those without ICDs.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/epidemiología , Displasia Ventricular Derecha Arritmogénica/terapia , Estudios Retrospectivos , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/etiología , Factores de Riesgo , América del Norte/epidemiología , Europa (Continente)/epidemiología
9.
Int J Cardiol ; 400: 131807, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38272130

RESUMEN

BACKGROUND: Left ventricular assist devices (LVADs) are an increasingly used strategy for the management of patients with advanced heart failure (HF). Subcutaneous implantable cardioverter defibrillator (S-ICD) might be a viable alternative to conventional ICDs with a lower risk of short- and long-term of device-related complications and infections.The aim of this multicenter study was to evaluate the outcomes and management of S-ICD recipients who underwent LVAD implantation. METHODS: The study population included patients with a preexisting S-ICD who underwent LVAD implantation for advanced HF despite optimal medical therapy. RESULTS: The study population included 30 patients (25 male; median age 45 [38-52] years).The HeartMate III was the most common LVAD type. Median follow-up in the setting of concomitant use of S-ICDs and LVADs was 7 months (1-20).There were no reports of inability to interrogate S-ICD systems in this population. Electromagnetic interference (EMI) occurred in 21 (70%) patients. The primary sensing vector was the one most significantly involved in determining EMI. Twenty-seven patients (90%) remained eligible for S-ICD implantation with at least one optimal sensing vector. The remaining 3 patients (10%) were ineligible for S-ICD after attempts of reprogramming of sensing vectors. Six patients (20%) experienced inappropriate shocks (IS) due to EMI. Six patients (20%) experienced appropriate shocks. No S-ICD extraction because of need for antitachycardia pacing, ineffective therapy or infection was reported. CONCLUSIONS: Concomitant use of LVAD and S-ICD is feasible in most patients. However, the potential risk of EMI oversensing, IS and undersensing in the post-operative period following LVAD implantation should be considered. Careful screening for EMI should be performed in all sensing vectors after LVAD implantation.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Corazón Auxiliar , Marcapaso Artificial , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/complicaciones , Corazón Auxiliar/efectos adversos , Marcapaso Artificial/efectos adversos , Resultado del Tratamiento
10.
Circ Arrhythm Electrophysiol ; 17(2): e012356, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38264885

RESUMEN

Genetic testing has become standard of care for patients with long QT syndrome (LQTS), providing diagnostic, prognostic, and therapeutic information for both probands and their family members. However, up to a quarter of patients with LQTS do not have identifiable Mendelian pathogenic variants in the currently known LQTS-associated genes. This absence of genetic confirmation, intriguingly, does not lessen the severity of LQTS, with the prognosis in these gene-elusive patients with unequivocal LQTS mirroring genotype-positive patients in the limited data available. Such a conundrum instigates an exploration into the causes of corrected QT interval (QTc) prolongation in these cases, unveiling a broad spectrum of potential scenarios and mechanisms. These include multiple environmental influences on QTc prolongation, exercise-induced repolarization abnormalities, and the profound implications of the constantly evolving nature of genetic testing and variant interpretation. In addition, the rapid advances in genetics have the potential to uncover new causal genes, and polygenic risk factors may aid in the diagnosis of high-risk patients. Navigating this multifaceted landscape requires a systematic approach and expert knowledge, integrating the dynamic nature of genetics and patient-specific influences for accurate diagnosis, management, and counseling of patients. The role of a subspecialized expert cardiogenetic clinic is paramount in evaluation to navigate this complexity. Amid these intricate aspects, this review outlines potential causes of gene-elusive LQTS. It also provides an outline for the evaluation of patients with negative and inconclusive genetic test results and underscores the need for ongoing adaptation and reassessment in our understanding of LQTS, as the complexities of gene-elusive LQTS are increasingly deciphered.


Asunto(s)
Electrocardiografía , Síndrome de QT Prolongado , Humanos , Síndrome de QT Prolongado/diagnóstico , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/terapia , Genotipo , Factores de Riesgo , Pruebas Genéticas
11.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38246594

RESUMEN

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Cardiomiopatías , Cardiomiopatía Dilatada , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/efectos adversos , Displasia Ventricular Derecha Arritmogénica/complicaciones , Cardiomiopatía Dilatada/complicaciones , Cardiomiopatía Dilatada/terapia , Sistema de Registros , Resultado del Tratamiento
12.
JACC Clin Electrophysiol ; 10(3): 487-498, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38206263

RESUMEN

BACKGROUND: Desmoplakin (DSP) pathogenic/likely pathogenic (P/LP) variants are associated with malignant phenotypes of arrhythmogenic cardiomyopathy (DSP-ACM). Reports of outcomes after ventricular tachycardia (VT) ablation in DSP-ACM are scarce. OBJECTIVES: In this study, the authors sought to report on long-term outcomes of VT ablation in DSP-ACM. METHODS: Patients with P/LP DSP variants at 9 institutions undergoing VT ablation were included. Demographic, clinical, and instrumental data as well as all ventricular arrhythmia (VA) events were collected. Sustained VAs after the index procedure were the primary outcome. A per-patient before and after ablation comparison of rates of VA episodes per year was performed as well. RESULTS: Twenty-four DSP-ACM patients (39.3 ± 12.1 years of age, 62.5% male, median 6,116 [Q1-Q3: 3,362-7,760] premature ventricular complexes [PVCs] per 24 hours, median 4 [Q1-Q3: 2-11] previous VA episodes per patient at ablation) were included. Index procedure was most commonly endocardial/epicardial (19/24) The endocardium of the right ventricle (RV), the left ventricle (LV), or both ventricles were mapped in 8 (33.3%), 9 (37.5%), and 7 (29.2%) cases, respectively. Low voltage potentials were found in 10 of 15 patients in the RV and 11 of 16 in the LV. Endocardial ablation was performed in 18 patients (75.0%). Epicardial mapping in 19 patients (79.2%) identified low voltage potentials in 17, and 16 received epicardial ablation. Over the following 2.9 years (Q1-Q3: 1.8-5.5 years), 13 patients (54.2%) experienced VA recurrences. A significant reduction in per-patient event/year before and after ablation was observed (1.4 [Q1-Q3: 0.5-2.4] to 0.1 [Q1-Q3: 0.0-0.4]; P = 0.009). Two patients needed heart transplantation, and 4 died (3 of heart failure and 1 noncardiac death). CONCLUSIONS: VT ablation in DSP-ACM is effective in reducing the VA burden of the disease, but recurrences are common. Most VT circuits are epicardial, with both LV and RV low voltage abnormalities. Heart failure complicates clinical course and is an important cause of mortality.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Cardiomiopatías , Ablación por Catéter , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Femenino , Desmoplaquinas , Resultado del Tratamiento , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/cirugía , Cardiomiopatías/etiología , Ablación por Catéter/métodos , Insuficiencia Cardíaca/etiología
14.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37935403

RESUMEN

Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a heritable cardiomyopathy characterized by a predominantly arrhythmic presentation. It represents the leading cause of sudden cardiac death (SCD) among athletes and poses a significant morbidity threat in the general population. As a causative treatment for ARVC is still not available, the placement of an implantable cardioverter defibrillator represents the current cornerstone for SCD prevention in this setting. Thanks to international ARVC-dedicated efforts, significant steps have been achieved in recent years towards an individualized, patient-centred risk stratification approach. A novel risk calculator algorithm estimating the 5-year risk of arrhythmias of patients with ARVC has been introduced in clinical practice and subsequently validated. The purpose of this article is to summarize the body of evidence that has allowed the development of this tool and to discuss the best way to implement its use in the care of an individual patient.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Desfibriladores Implantables , Humanos , Factores de Riesgo , Displasia Ventricular Derecha Arritmogénica/complicaciones , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/terapia , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/complicaciones , Desfibriladores Implantables/efectos adversos , Medición de Riesgo
15.
Elife ; 122023 10 18.
Artículo en Inglés | MEDLINE | ID: mdl-37851708

RESUMEN

Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a genetic cardiac disease that leads to ventricular tachycardia (VT), a life-threatening heart rhythm disorder. Treating ARVC remains challenging due to the complex underlying arrhythmogenic mechanisms, which involve structural and electrophysiological (EP) remodeling. Here, we developed a novel genotype-specific heart digital twin (Geno-DT) approach to investigate the role of pathophysiological remodeling in sustaining VT reentrant circuits and to predict the VT circuits in ARVC patients of different genotypes. This approach integrates the patient's disease-induced structural remodeling reconstructed from contrast-enhanced magnetic-resonance imaging and genotype-specific cellular EP properties. In our retrospective study of 16 ARVC patients with two genotypes: plakophilin-2 (PKP2, n = 8) and gene-elusive (GE, n = 8), we found that Geno-DT accurately and non-invasively predicted the VT circuit locations for both genotypes (with 100%, 94%, 96% sensitivity, specificity, and accuracy for GE patient group, and 86%, 90%, 89% sensitivity, specificity, and accuracy for PKP2 patient group), when compared to VT circuit locations identified during clinical EP studies. Moreover, our results revealed that the underlying VT mechanisms differ among ARVC genotypes. We determined that in GE patients, fibrotic remodeling is the primary contributor to VT circuits, while in PKP2 patients, slowed conduction velocity and altered restitution properties of cardiac tissue, in addition to the structural substrate, are directly responsible for the formation of VT circuits. Our novel Geno-DT approach has the potential to augment therapeutic precision in the clinical setting and lead to more personalized treatment strategies in ARVC.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Taquicardia Ventricular , Humanos , Displasia Ventricular Derecha Arritmogénica/genética , Estudios Retrospectivos , Taquicardia Ventricular/genética , Arritmias Cardíacas , Genotipo
16.
J Clin Med ; 12(20)2023 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-37892671

RESUMEN

BACKGROUND: The safety and efficacy of an uninterrupted direct anticoagulation (DOAC) strategy during catheter ablation (CA) for atrial fibrillation (AF) has not been fully investigated with different ablation techniques. METHODS: We evaluated consecutive AF patients undergoing catheter ablation with three different techniques. All patients were managed with an uninterrupted DOAC strategy. The primary endpoint was the rate of periprocedural thromboembolic and bleeding events. The secondary endpoints of the study were the rate of MACE and bleeding events at one-year follow-up. RESULTS: In total, 162 patients were enrolled. Overall, 53 were female and the median age was 60 [55.5-69.5] years. The median CHA2DS2-VASc and HAS-BLED scores were 2 [1-4] and 2 [1-2], respectively. In total, 16 patients had a past stroke or TIA while 11 had a predisposition or a history of bleeding. The CA procedure was performed with different techniques: RF 43%, cryoballoon 37%, or laser-balloon 20%. Overall, 35.8% were on rivaroxaban, 20.4% were on edoxaban, 6.8% were on apixaban, and 3.7% were on dabigatran. All other patients were all naïve to DOACs; the first anticoagulant dose was given before the ablation procedure. As for periprocedural complications, we found three groin hematomas not requiring interventions, one ischemic stroke, and one systemic air embolism (the last two likely due to several catheter changes through the transeptal sheath). Five patients reached the secondary endpoints: one patient for a myocardial infarction while four patients experienced minor bleeding during 1-year follow-up. CONCLUSIONS: Our results corroborate the safety and the efficacy of uninterrupted DOAC strategy in patients undergoing CA for AF, regardless of the ablation technique.

17.
J Cardiovasc Electrophysiol ; 34(12): 2443-2451, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37767727

RESUMEN

INTRODUCTION: Regardless of the catheter ablation (CA) for atrial fibrillation (AF) strategy, the role of early recurrences during the blanking period (BP) is still unclear. Our aim was to evaluate atrial tachyarrhythmias (ATAs) recurrences during the BP after CA with the laser-balloon (LB) technique. METHODS: Consecutive patients undergoing LBCA were enrolled. Primary outcome of the study was the overall crude ATA recurrence rate during the BP. ATA recurrences after the BP and in-hospital readmissions during the BP were deemed secondary outcomes. RESULTS: Two hundred and twenty-four patients underwent CA with the LB. Median age was 63.0 (55.5-69.5) years and 74.1% were males. 28.6% were persistent AF patients, and 34.8% of patients were followed up with a loop recorder. 15.6% of patients experienced at least an ATA recurrence during the BP. Male sex, chronic heart failure, persistent AF, and recurrences during the BP were found to be associated with long-term ATA recurrences. Recurrences during the BP remained associated with the outcome of interest at multivariate analysis (hazard ratio [HR] = 12.393, 95% confidence interval [95% CI] = 3.699-41.865, p < .001). An association over time was found between early and late recurrences, with 73.7%, 45.5%, and 10.8% of patients presenting with recurrences at 1-, 2-, and 3-month follow-up being free from recurrences after the BP, respectively. 8.0% of patients were readmitted during the BP: 4.5% for AF electrical cardioversion, and 1.8% for CA of other atrial arrhythmias; no redo CA was performed. CONCLUSION: After adjusting for confounders, ATA recurrences during the BP represent the most significant predictor of ATA recurrences after the BP, regardless of AF pattern.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Persona de Mediana Edad , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Factores de Tiempo , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia , Venas Pulmonares/cirugía , Rayos Láser
18.
JACC Clin Electrophysiol ; 9(12): 2615-2627, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37768253

RESUMEN

BACKGROUND: Electrocardiographic (ECG) findings in arrhythmogenic left ventricular cardiomyopathy (ALVC) are limited to small case series. OBJECTIVES: This study aimed to analyze the ECG characteristics of ALVC patients and to correlate ECG with cardiac magnetic resonance and genotype data. METHODS: We reviewed data of 54 consecutive ALVC patients (32 men, age 39 ± 15 years) and compared them with 84 healthy controls with normal cardiac magnetic resonance. RESULTS: T-wave inversion was often noted (57.4%), particularly in the inferior and lateral leads. Low QRS voltages in limb leads were observed in 22.2% of patients. The following novel ECG findings were identified: left posterior fascicular block (LPFB) (20.4%), pathological Q waves (33.3%), and a prominent R-wave in V1 with a R/S ratio ≥0.5 (24.1%). The QRS voltages were lower in ALVC compared with controls, particularly in lead I and II. At receiver-operating characteristic analysis, the sum of the R-wave in I to II ≤8 mm (AUC: 0.909; P < 0.0001) and S-wave in V1 plus R-wave in V6 ≤12 mm (AUC: 0.784; P < 0.0001) effectively discriminated ALVC patients from controls. It is noteworthy that 4 of the 8 patients with an apparently normal ECG were recognized by these new signs. Transmural late gadolinium enhancement was associated to LPFB, a R/S ratio ≥0.5 in V1, and inferolateral T-wave inversion, and a ringlike pattern correlated to fragmented QRS, SV1+RV6 ≤12 mm, low QRS voltage, and desmoplakin alterations. CONCLUSIONS: Pathological Q waves, LPFB, and a prominent R-wave in V1 were common ECG signs in ALVC. An R-wave sum in I to II ≤8 mm and SV1+RV6 ≤12 mm were specific findings for ALVC phenotypes compared with controls.


Asunto(s)
Cardiomiopatías , Medios de Contraste , Masculino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Gadolinio , Electrocardiografía , Arritmias Cardíacas , Bloqueo de Rama
19.
Heart Rhythm ; 20(12): 1720-1726, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37657721

RESUMEN

BACKGROUND: The diagnosis of arrhythmogenic right ventricular cardiomyopathy (ARVC) is challenging because of nonspecific clinical findings and lack of conclusive answers from genetic testing (ie, an ARVC-related variant is neither necessary nor sufficient for diagnosis). Despite the revised 2010 Task Force Criteria, patients are still misdiagnosed with ARVC. OBJECTIVE: In patients referred for ARVC, we sought to identify the clinical characteristics and diagnostic confounders for those patients in whom ARVC was ultimately ruled out. METHODS: Patients who were referred to our center with previously diagnosed or suspected ARVC (between January 2011 and September 2019; N = 726) were included in this analysis. RESULTS: Among 726 patients, ARVC was ruled out in 365 (50.3%). The most common presenting symptoms in ruled-out patients were palpitations (n = 139, 38.1%), ventricular arrhythmias (n = 62, 17.0%), and chest pain (n = 53, 14.5%). On the basis of outside evaluation, 23.8% of these patients had received implantable cardioverter-defibrillators (ICDs) and device extraction was recommended in 9.0% after reevaluation. An additional 5.5% had received ICD recommendations, all of which were reversed on reevaluation. The most frequent final diagnoses were idiopathic premature ventricular contractions/ventricular tachycardia/ventricular fibrillation (46.6%), absence of disease (19.2%), and noncardiac presyncope/syncope (17.5%). The most common contributor to diagnostic error was cardiac magnetic resonance imaging, including mistaken right ventricular wall motion abnormalities (33.2%) and nonspecific fat (12.1%). CONCLUSION: False suspicion or misdiagnosis was found in the majority of patients referred for ARVC, resulting in inappropriate ICD implantation or recommendation in 14.5% of these patients. Misdiagnosis or false suspicion was most commonly due to misinterpretation of cardiac magnetic resonance imaging.


Asunto(s)
Displasia Ventricular Derecha Arritmogénica , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Displasia Ventricular Derecha Arritmogénica/diagnóstico , Displasia Ventricular Derecha Arritmogénica/terapia , Displasia Ventricular Derecha Arritmogénica/genética , Arritmias Cardíacas , Imagen por Resonancia Magnética
20.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37649337

RESUMEN

AIMS: Pulsed field ablation (PFA) is a non-thermal ablative approach in which cardiomyocyte death is obtained through irreversible electroporation (IRE). Data correlating the biophysical characteristics of IRE and lesion characteristics are limited. The aim of this study was to assess the effect of different procedural parameters [voltage, number of cycles (NoCs), and contact] on lesion characteristics in a vegetal and animal model for IRE. METHODS AND RESULTS: Two hundred and four Russet potatoes were used. Pulsed field ablation lesions were delivered on 3 cm cored potato specimens using a multi-electrode circular catheter with its dedicated IRE generator. Different voltage (from 300 to 1200 V) and NoC (from 1 to 5×) protocols were used. The impact of 0.5 and 1 mm catheter-to-specimen distances was tested. A swine animal model was then used to validate the results observed in the vegetable model. The association between voltage, the NoCs, distance, and lesion depth was assessed through linear regression. An almost perfect linear association between lesion depth and voltage was observed (R2 = 0.95; P < 0.001). A similarly linear relationship was observed between the NoCs and the lesion depth (R2 = 0.73; P < 0.001). Compared with controls at full contact, a significant dampening on lesion depth was observed at 0.5 mm distance (1000 V 2×: 2.11 ± 0.12 vs. 0.36 ± 0.04, P < 0.001; 2.63 ± 0.10 vs. 0.43 ± 0.08, P < 0.001). No lesions were observed at 1.0 mm distance. CONCLUSION: In a vegetal and animal model for IRE assessment, PFA lesion characteristics were found to be strongly dependent on voltage settings and the NoCs, with a quasi-linear relationship. The lack of catheter contact was associated with a dampening in lesion depth.


Asunto(s)
Adiposidad , Obesidad , Animales , Porcinos , Catéteres , Electrodos , Electroporación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...