Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Braz Dent J ; 35: e245883, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38775594

RESUMEN

This study assessed the intratubular antibacterial ability of different activated irrigations after chemical mechanical preparation. Seventy-two palatal root canals of upper molars were infected with Enterococcus faecalis for 4 weeks, and then initial bacterial collection from the main root canal was performed. The root canals were prepared by using a WaveOne Gold large (45/.05) and distributed into 6 groups according to the activation of the final irrigation: ultrasonic activation (UA), XP-Endo Finisher (25/.00), XP Clean (25/.02), EasyClean (25/.04) in reciprocating motion and continuous rotary motion (ECRot), and conventional irrigation. After final irrigation, another bacterial collection from the main root canal was performed, and the root was sectioned transversely in three-thirds and stained for analysis by confocal laser microscopy. Intratubular bacteria were collected through dentin powder and plated for bacterial viability analysis. Intergroup and intragroup comparisons were performed by using analysis of variance and repeated measures analysis of variance, respectively, both at 5% significance. ECRot had higher antibacterial ability than UA (p<0.05), and both were superior to the other groups (p<0.05) in both methodologies. It can be concluded that activation of final irrigation enhances the disinfection of the root canal system, and activators have different efficacies.


Asunto(s)
Antibacterianos , Enterococcus faecalis , Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Humanos , Irrigantes del Conducto Radicular/farmacología , Preparación del Conducto Radicular/métodos , Antibacterianos/farmacología , Cavidad Pulpar/microbiología , Microscopía Confocal , Irrigación Terapéutica/métodos , Diente Molar
2.
Clin Oral Investig ; 28(3): 205, 2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38459266

RESUMEN

OBJECTIVE: To assess the anesthetic efficacy of articaine with the needle-free/Comfort-in™ method compared to the conventional needle method. To assess pain during anesthesia application, onset of anesthesia and patient`s self-reported quality of life-related to oral health after the dental emergency appointment. MATERIALS AND METHODS: This parallel, randomized clinical trial was conducted by a single operator/dentist in the state of Maranhao, northeast of Brazil. Included participants were adult dental patients with one molar (maxillary) or premolar (maxillary or mandibular) tooth diagnosed with symptomatic irreversible pulpitis. The primary outcome was the anesthetic efficacy, measured using a combination of electrical and cold pulp tests (cold + EPT) and the Numerical Rating Scale (NRS). Secondary outcomes were pain during anesthesia application, onset of anesthesia, and patient`s quality-of-life (measured with the OHIP-14). RESULTS: 62 patients were randomized in the anesthesia needle-free group and Comfort-in group (34.26 ± 10.786 × 33.29 ± 8.399 years old, respectively). The group of patients in the Comfort-in group had 71.0% success. Patients from the Comfort-in group reported statistically lower pain during the anesthesia application than patients from the conventional group (2.13 ± 2.172 × 6.03 ± 3.146 NRS scores, respectively) as well as immediately after the anesthetic procedure. Patients self-reported negative impact in quality of life was similar between groups before (p > 0.05) and after (p > 0.05) the dental emergency. CONCLUSIONS: Comfort-in™ had similar efficacy to the conventional needle method. CLINICAL RELEVANCE: This trial showed that it is possible to anesthetize patients with tooth pulpits without using needles to provide comfort mainly to anxious patients.


Asunto(s)
Anestesia Dental , Bloqueo Nervioso , Pulpitis , Adulto , Humanos , Adulto Joven , Carticaína , Pulpitis/cirugía , Anestésicos Locales , Calidad de Vida , Bloqueo Nervioso/métodos , Anestesia Dental/métodos , Dolor , Método Doble Ciego , Nervio Mandibular , Lidocaína
3.
Braz Dent J ; 35: e245611, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38537014

RESUMEN

This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Humanos , Preparación del Conducto Radicular/métodos , Ultrasonido , Irrigantes del Conducto Radicular , Irrigación Terapéutica/métodos , Microtomografía por Rayos X , Dentina
4.
Braz Oral Res ; 38: e006, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38198306

RESUMEN

The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.


Asunto(s)
Cavidad Pulpar , Oro , Microtomografía por Rayos X , Cavidad Pulpar/diagnóstico por imagen , Análisis de Varianza , Diente Molar/diagnóstico por imagen
5.
Braz. oral res. (Online) ; 38: e006, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1528151

RESUMEN

Abstract The aim of this study was to evaluate the root canal shaping effect of ProTaper Gold (PTG) versus ProTaper Next (PTN) instrumentation systems, and of a manual #15 K-type file (K15) versus the ProGlider (PG) mechanized instrument for glide path creation, in severely curved mesial canals. Twenty-four mandibular molars with two separate mesial canals were anatomically matched using computed tomographic scanning, and then divided into two groups (n=12) according to the glide path instrument used, either K15 or PG. In all teeth, the PTG system was used to prepare the mesiobuccal canal, and the PTN, the mesiolingual canal. The teeth were scanned by computed microtomography, before and after root canal preparation, and the values of the initial volume, final volume, volumetric variation, untouched walls, and canal transportation variables were determined. The data were analyzed using the two-way ANOVA test, and the Tukey test for multiple comparisons. There was no significant difference among the study groups regarding volumetric variation or root canal transportation, either in the cervical, middle or apical thirds, or in the entire root canal (p>0.05). In the apical third, the percentage of untouched walls was significantly higher in groups using K15 than in those using PG (p<0.05), namely 33.144% and 23.285%, respectively, irrespective of the instrumentation system. In the other regions, there was no difference between K15 and PG regarding this variable. It was concluded that PG was associated with a lower rate of untouched walls in the apical region than K15.

6.
Braz. dent. j ; 35: e24, 2024. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1550086

RESUMEN

Abstract This study evaluated the correlation between root canal curvature and the effects of ultrasonic irrigation in the following parameters: volume of uncontrolled dentin removal (UDRVol), maximum depth of dentin defects, removal of accumulated hard tissue debris (AHTD), and canal transportation in prepared curved root canals. Twenty-four human permanent mandibular molars were divided into two groups according to root canal curvature: moderate curvature (MC: mean 25°); and severe curvature (SC: mean 48°). The specimens were scanned using an X-ray microcomputed scanner (Skyscan 1172) before and after cleaning and shaping and after the final irrigation protocol with ultrasonic irrigation. There was a moderate correlation between the degree of root canal curvature and the volume of remaining AHTD (p<0.05) and between the degree of root canal curvature and maximum depth of defects due to uncontrolled removal of dentin (p<0.05). The teeth in the SC group had a greater maximum depth of defects on the dentin wall in the apical third than the teeth in the MC group (p <0.05). Both groups had a significant reduction of AHTD in all canal thirds, but the amount of remaining AHTD in the middle and apical thirds and the whole canal was significantly greater in the SC than in the MC group (p <0.05). Canal transportation was not influenced by the canal curvature in all thirds (p >0.05). This study concluded that root canal curvature affects significantly the uncontrolled removal of dentin and remaining AHTD volume after the final irrigation protocol with ultrasonic irrigation.


Resumo Este estudo avaliou a correlação entre a curvatura do canal radicular e os efeitos da irrigação ultrassônica nos seguintes parâmetros: volume de remoção não controlada de dentina (UDRVol), profundidade máxima do desgaste de dentina, remoção de debris de tecido duro acumulado (AHTD) e transporte em canais radiculares curvos. Vinte e quatro molares inferiores humanos permanentes foram divididos em dois grupos de acordo com a curvatura do canal radicular: curvatura moderada (MC: média de 25°); e curvatura acentuada (SC: média de 48°). Os espécimes foram digitalizados usando um scanner microcomputador de raios X (Skyscan 1172) antes e depois da limpeza e modelagem e após a irrigação ultrassônica. Houve uma correlação moderada entre o grau de curvatura do canal radicular e o volume de AHTD remanescente (p<0,05) e entre o grau de curvatura do canal radicular e a profundidade máxima de defeitos devido à remoção descontrolada de dentina (p<0,05). Os dentes do grupo SC apresentaram maior profundidade máxima de defeitos na parede dentinária no terço apical do que os dentes do grupo MC (p<0,05). Ambos os grupos tiveram uma redução significativa de AHTD em todos os terços do canal, mas a quantidade de AHTD remanescente nos terços médio e apical e em todo o canal foi significativamente maior no grupo SC do que no grupo MC (p <0,05). O transporte do canal não foi influenciado pela curvatura do canal em todos os terços (p > 0,05). Este estudo concluiu que a curvatura do canal radicular afeta significativamente a remoção descontrolada de dentina e o volume remanescente de AHTD após a irrigação ultrassônica.

7.
Rev. Fac. Odontol. Porto Alegre ; 64(1): e135470, dez 2023.
Artículo en Portugués | LILACS-Express | LILACS | ID: biblio-1526435

RESUMEN

Objetivo: O objetivo deste estudo foi avaliar a extrusão apical de irrigantes em dentes imaturos simulados, comparando a irrigação convencional com outros dispositivos de irrigação por pressão negativa. Materiais e Métodos: 48 amostras de dentes imaturos simulados foram montadas em um modelo adaptado para conter o irrigante extravasado e distribuídas igualmente em 4 grupos (n=12) de acordo com o dispositivo de irrigação utilizado: Grupo Irrigação Convencional (IC), Grupo EndoVac (EV), Grupo Pulp Sucker (PS) e Grupo Ivac (IV). As amostras foram irrigadas com 15mL de solução irrigadora, sendo 10mL de NaOCl a 2,5% e 5mL de EDTA a 17% intercalados. As amostras foram pesadas em balança de precisão antes e depois dos procedimentos de irrigação, sendo a diferença entre os pesos final e inicial considerado o volume de irrigante extravasado. Os dados foram coletados e analisados estatisticamente pelos testes de Kruskal-wallis e exato de Fisher. Resultados: Os grupos que utilizaram pressão negativa promoveram significativamente menor volume de irrigante extravasado que o grupo IC (p<0,05), não havendo diferenças significativas quando comparados entre si (p>0,05). Houve diferenças significativas na associação entre os grupos e a extrusão de irrigante, sendo o grupo PS menos associado a extrusão de irrigante (p<0,005). Discussão: Estudos anteriores apontam os dispositivos de pressão negativa como opções seguras diante de extravasamento de irrigantes quando comparados à irrigação convencional. Conclusão: A irrigação convencional promoveu significativamente maior volume de extrusão de irrigante quando comparada aos dispositivos de irrigação por pressão negativa. O sistema PulpSucker mostrou extravasamento de irrigante em um número significativamente menor de amostras.


Aim: The aim of this study was to evaluate the apical extrusion of irrigants in simulated immature teeh, comparing convencional irrigation with other negative pressure irrigation devices. Materials and methods: 48 samples of simulated immature teeth were set up in an adapted model to contain the extravasated irrigant and evenly distributed into 4 groups (n=12) according to the device used: Convencional Irrigation Group (CI), EndoVac Group (EV), Pulp Sucker Group (PS) and Ivac Group (IV). The samples were irrigated with 15mL of irrigant solution, consisting of 10mL NaOCl 2,5% and 5mL EDTA 17%, in na alternating sequence. The samples' weights were measured using a precision scale before and after the irrigation procedures, with the difference between de final and initial weights considered the volume of extravasated irrigant. Data were collected and statistically analyzed by Kruskal-wallis and Fisher exact tests. Results: The groups that used negative pressure devices significantly promoted a lower volume of extruded irrigant than the CI group (p<0,05), with no significant differences between the negative pressure groups (p>0,05). There were signficant differences in the association between the groups and irrigant extrusion, with the PS group showing significantly less association with irrigant extrusion (p<0,005). Discussion: Previous studies have indicated that negative pressure devices are safe alternatives to convencional irrigation when considering irrigant extrusion. Conclusion: Conventional irrigation promoted a significantly greater volume of irrigant extrusion when compared to negative pressure irrigation devices. The PulpSucker system showed irrigant extravasation in significantly fewer samples.

8.
J Clin Exp Dent ; 15(11): e938-e944, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38074173

RESUMEN

Background: This study aimed to assess the knowledge of Brazilian endodontists regarding the use of cone beam computed tomography (CBCT) in endodontic therapy. Material and Methods: An invitation to participate in the research was sent to 3256 professionals through class groups on social networks and via email. Participants answered an online questionnaire consisting of 11 questions about the clinical situations in which they used CBCT and whether they had any knowledge of the technical protocols such as parameters of field of view (FOV) and voxels of the CBCT equipment. The questionnaire was answered by 742 endodontists who represented 22.7% of the invited professionals. Results: The data obtained indicate that 76.7% of the participants use or have used CBCT during endodontic treatments. The most often reported clinical conditions for using the CBCT were: root fractures (64%), locating the canals (58.7%), perforations (53.9%), and root resorption (42.1%). More than 60% of the participants stated that they do not have information about the voxel, FOV, and the CBCT system used in their requests. Only 34.1% reported using CBCT to the performed endodontic treatments follow-up. Conclusions: CBCT was a tool widely utilized by the participants, with root fracture being the clinical condition with the highest indication for CBCT. Many professionals were unaware of the technical protocol used in the exams. Key words:Endodontics, Cone Beam Computed Tomography, Endodontic Therapy.

9.
Braz Dent J ; 34(2): 35-40, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37194855

RESUMEN

This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Tratamiento del Conducto Radicular , Microtomografía por Rayos X , Oro
10.
Polymers (Basel) ; 15(7)2023 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-37050293

RESUMEN

This study evaluated the apical sealing ability and bioactivity of an experimental gutta-percha containing niobium phosphate bioglass. Thirty-six human premolars were endodontically prepared and divided into three groups: GPC-filling with conventional gutta-percha; GBC-filling with bioceramic gutta-percha (EndoSequence BC); GNB-filling with experimental gutta-percha containing niobophosphate. Teeth were stored in tubes containing 2 mL of simulated body fluid (SBF) solution in an oven for 30 days. Then, the samples were immersed in lanthanum nitrate solution and analyzed for apical nanoleakage (NI) with a scanning electron microscope (SEM/EDS) and transmission electron microscope (TEM). Gutta-percha specimens were immersed for 28 days (SBF) and analyzed in SEM/EDS and X-ray diffraction (XRD) to assess bioactivity. NI data originated from the SEM/EDS were analyzed using the Kruskal-Wallis test (α = 5%). NI data originated from TEM and bioactivity were descriptively reported. Statistical analysis did not detect a significant difference between groups (p = 0.13) for NI. In the bioactivity analysis, an abundant layer of hydroxyapatite was identified only in the surface of the GNB group samples. The gutta-percha containing niobophosphate bioglass promoted an apical sealing similar to EndoSequence BC, in addition to demonstrating bioactivity through the deposition of hydroxyapatite on the surface of the material after immersion in SBF.

11.
Braz Dent J ; 34(1): 1-11, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36888836

RESUMEN

A continuous search for bioactive materials capable of supporting the replacement of damaged pulp tissue, with effective sealing potential and biocompatibility, has represented the attention of studies over the last decades. This study involves a narrative review of the literature developed by searching representative research in PUBMED/MEDLINE and searches in textbooks associated with the mechanism of action of bioactive materials (calcium hydroxide, mineral trioxide aggregate (MTA), and calcium silicate cements). The reflective analysis of the particularities of the chemical elements of these materials, considering the tissue and antibacterial mechanism of action, allows a better understanding of the characteristics and similarities in their tissue responses. Calcium hydroxide paste remains the antibacterial substance of choice as intracanal dressing for the treatment of root canal system infections. Calcium silicate cements, including MTA, show a favorable biological response with the stimulation of mineralized tissue deposition in sealed areas when in contact with connective tissue. This is due to the similarity between the chemical elements, especially ionic dissociation, the potential stimulation of enzymes in tissues, and the contribution towards an alkaline environment due to the pH of these materials. The behavior of bioactive materials, especially MTA and the new calcium silicate cements in the biological sealing activity, has been shown to be effective. Contemporary endodontics has access to bioactive materials with similar properties, which can stimulate a biological seal in lateral and furcation root perforations, root-end fillings and root fillings, pulp capping, pulpotomy, apexification, and regenerative endodontic procedures, in addition to other clinical conditions.


Asunto(s)
Hidróxido de Calcio , Materiales de Obturación del Conducto Radicular , Hidróxido de Calcio/farmacología , Materiales de Obturación del Conducto Radicular/farmacología , Materiales de Obturación del Conducto Radicular/química , Cementos Dentales/química , Compuestos de Calcio/farmacología , Compuestos de Calcio/química , Silicatos/farmacología , Silicatos/química , Antibacterianos/uso terapéutico , Óxidos/farmacología , Óxidos/química , Combinación de Medicamentos , Compuestos de Aluminio/farmacología , Compuestos de Aluminio/química
12.
Braz. dent. j ; 34(2): 35-40, Mar.-Apr. 2023. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1439565

RESUMEN

Abstract This study compared the preparation of long oval-shaped root canals using WaveOne Gold and XP-endo Shaper systems, both supplemented or not with manual instrumentation. Twenty-four long oval-shaped canals of mandibular incisors were distributed into two groups according to the instrumentation: WaveOne Gold Primary or XP-endo Shaper systems. All root canals were manually instrumented with a size 25 K-file after automated preparation. The specimens were scanned by using a micro-CT device (17.42 µm) before and after automated preparation and manual instrumentation. The increased surface of the root canal and the percentage of untouched areas were assessed. Both WaveOne Gold and XP-endo Shaper systems increased the root canal surface and had similar untouched areas (p>0.05). Supplementary instrumentation increased the surface of the root canal and decreased the untouched walls (p<0.05). WaveOne Gold and XP-endo Shaper systems provided a similar preparation of long oval-shaped canals and manual instrumentation improved their preparation.


Resumo Este estudo comparou o preparo de canais radiculares ovais longos usando os sistemas WaveOne Gold e XP-endo Shaper, ambos complementados ou não com instrumentação manual. Vinte e quatro canais longos e ovais de incisivos inferiores foram distribuídos em dois grupos de acordo com a instrumentação: sistemas WaveOne Gold Primary ou XP-endo Shaper. Todos os canais foram instrumentados manualmente com uma lima K tamanho 25 após preparo automatizado. Os espécimes foram escaneados usando um dispositivo de micro-CT (17,42 µm) antes e após o preparo automatizado e instrumentação manual. O aumento de superfície do canal radicular e a porcentagem de áreas intocadas foram avaliadas. Ambos os sistemas WaveOne Gold e XP-endo Shaper aumentaram a superfície do canal radicular e apresentaram áreas intocadas semelhantes (p>0,05). A instrumentação complementar aumentou a superfície do canal radicular e diminuiu o percentual de áreas intocadas (p <0,05). Os sistemas WaveOne Gold e XP-endo Shaper tiveram o preparo de canais ovais longos semelhantes, e a instrumentação manual melhorou o preparo.

13.
Braz. dent. j ; 34(1): 1-11, Jan.-Feb. 2023. graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - Odontología | ID: biblio-1420576

RESUMEN

Abstract A continuous search for bioactive materials capable of supporting the replacement of damaged pulp tissue, with effective sealing potential and biocompatibility, has represented the attention of studies over the last decades. This study involves a narrative review of the literature developed by searching representative research in PUBMED/MEDLINE and searches in textbooks associated with the mechanism of action of bioactive materials (calcium hydroxide, mineral trioxide aggregate (MTA), and calcium silicate cements). The reflective analysis of the particularities of the chemical elements of these materials, considering the tissue and antibacterial mechanism of action, allows a better understanding of the characteristics and similarities in their tissue responses. Calcium hydroxide paste remains the antibacterial substance of choice as intracanal dressing for the treatment of root canal system infections. Calcium silicate cements, including MTA, show a favorable biological response with the stimulation of mineralized tissue deposition in sealed areas when in contact with connective tissue. This is due to the similarity between the chemical elements, especially ionic dissociation, the potential stimulation of enzymes in tissues, and the contribution towards an alkaline environment due to the pH of these materials. The behavior of bioactive materials, especially MTA and the new calcium silicate cements in the biological sealing activity, has been shown to be effective. Contemporary endodontics has access to bioactive materials with similar properties, which can stimulate a biological seal in lateral and furcation root perforations, root-end fillings and root fillings, pulp capping, pulpotomy, apexification, and regenerative endodontic procedures, in addition to other clinical conditions.


Resumo Uma busca contínua de materiais bioativos com capacidade de substituir o tecido pulpar danificado, com efetiva capacidade de selamento e biocompatibilidade, tem representado a atenção e foco de muitos estudos ao longo das últimas décadas. Este estudo envolve uma revisão narrativa da literatura desenvolvida por meio de pesquisas representativas encontradas no PUBMED/MEDLINE e pesquisas em livros didáticos associadas ao mecanismo de ação de materiais bioativos (hidróxido de cálcio, agregado de trióxido mineral (MTA) e cimentos de silicato de cálcio). A presente análise reflexiva das particularidades dos elementos químicos destes materiais bioativos, considerando o mecanismo de ação tecidual e antibacteriano, possibilita um melhor entendimento das características e similaridades no comportamento tecidual. A pasta de hidróxido de cálcio continua sendo a substância antibacteriana de escolha como medicação intracanal para o tratamento das infecções do sistema de canais radiculares. Este fato se deve a disponibilidade química de íons cálcio e hidroxila do hidróxido de cálcio aos tecidos, e a inibição enzimática bacteriana. Os cimentos de silicato de cálcio, dentre os quais inclui o MTA, apresentam uma resposta biológica favorável ao estímulo à deposição de tecido mineralizado nas áreas seladas e em contato com tecido conjuntivo. Este fato é decorrente da similaridade entre os elementos químicos, em especial devido a dissociação iônica, ao potencial estímulo de enzimas teciduais, e a contribuição com um meio alcalino decorrente do pH destes materiais. O comportamento dos materiais bioativos, em especial o MTA e os novos cimentos de silicato de cálcio na atividade de selamento biológico mostraram efetivos. A endodontia contemporânea atualmente conta com o potencial de materiais bioativos com propriedades análogas capaz de estimular o selamento biológico em perfurações radiculares laterais e de furca, em obturações radiculares, capeamento pulpar, pulpotomia, apicificação e procedimentos endodônticos regenerativos, além de outras condições clínicas.

14.
Aust Endod J ; 49 Suppl 1: 315-322, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36658667

RESUMEN

This study evaluated, through micro-computed tomography (micro-CT), the volume of irrigant diffusion by different techniques of final agitation. Sixty mesiobuccal canals were scanned in a micro-CT and standardised according to the volume. They were instrumented with the MTwo 40/04 system and using the Terebrix 35 contrast solution as irrigant, were divided into six groups (n = 10): Conventional irrigation with syringe and needle (CI), EndoActivator (EA), EasyClean (EC), RinsEndo (RE), Utrasonic agitation (UI) and XP-Clean (XP). A second micro-CT scan was performed and the total irrigant volume and in the final 3 mm apical were determined. The data were analysed using the Anova, Kruskal-Wallis and Dunn tests (p < 0.05). UI and XP showed a higher percentage of total diffusion than CI, EA and RS groups (p < 0.05). In apical diffusion, there was no significant difference between groups (p > 0.05). The final agitation system increases the diffusion of irrigating agents inside the root canal.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Microtomografía por Rayos X , Preparación del Conducto Radicular/métodos , Irrigantes del Conducto Radicular/uso terapéutico , Tratamiento del Conducto Radicular , Irrigación Terapéutica/métodos , Hipoclorito de Sodio
15.
Clin Oral Investig ; 27(3): 1153-1158, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36104605

RESUMEN

AIM: To evaluate the influence of different kinematics on the efficiency and safety of an engine-driven file for glide path preparation in second mesiobuccal canals (MB2) of maxillary molars. In addition, the torsional resistance of the file was assessed after use. METHODOLOGY: Thirty-six maxillary first and second molars with two canals in the mesiobuccal root were selected and the anatomy of the canals was verified by micro-CT. The teeth were divided into 4 groups (n = 9) according to the kinematics used for glide path preparation: continuous rotation (CR), 30°/150° reciprocation (REC 30°/150°), 30°/90° reciprocation (REC 30°/90°), and 90° optimum glide path motion (OGP 90°). The duration of the procedure, number of canals in which the file reached the full working length (RFWL), canal volume before and after the procedure, rate of file fracture, and file torsional strength after use were evaluated. The ANOVA and Tukey tests or Kruskal-Wallis and Dunn tests were used for statistical analysis. RESULTS: No significant differences among the groups were found for procedure duration, success at reaching the FWL, distance from the file to apex, and number of fractured files (P > 0.05). The CR group showed a significant decrease in rotation angle compared with REC 90° and OGP 90° groups (P < 0.05). There was no significant difference in canal volume among the groups (P > 0.05). CONCLUSION: The type of kinematics used did not affect the efficiency, success rate, and shaping ability of the file during glide path preparation. CR seems to induce more torsional stress than the other kinematics. CLINICAL RELEVANCE: The glide path preparation of narrow canals such as the MB2 is difficult and accidents such as file fracture may occur. This study showed that reciprocation with different file angulations can be safer during this challenging stage.


Asunto(s)
Preparación del Conducto Radicular , Raíz del Diente , Fenómenos Biomecánicos , Preparación del Conducto Radicular/métodos , Diente Molar , Cavidad Pulpar , Diseño de Equipo
16.
J Endod ; 48(5): 572-596, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35114271

RESUMEN

INTRODUCTION: Culture-independent molecular studies have shown a broad spectrum of bacterial taxa that persist after chemomechanical procedures (CMP). Therefore, this study systematically reviewed these reports to explore the prevalence of bacteria in post-instrumentation samples of root canals from permanent teeth, especially of as-yet-uncultivated/difficult-to-culture bacteria. METHODS: Electronic databases were searched from 2007 to January 2021. Clinical studies using culture-independent molecular methods to identify species-level taxa before and after CMP were included. Studies were critically appraised using the Joanna Briggs Institute Prevalence Critical Appraisal Checklist and the funnel plot analysis. The meta-analysis was performed on the prevalence of as-yet-uncultivated/difficult-to-culture bacterial taxa using RStudio. RESULTS: A total of 3781 titles were screened, but only 20 studies were included. The most frequent species in post-instrumentation samples were Streptococcus spp., Leptotrichia buccalis, Fusobacterium nucleatum, and Capnocytophaga ochracea. The detection frequency of some species increased after CMP, including mainly Firmicutes members such as streptococci, Enterococcus faecium, Selenomonas noxia, and Solobacterium moorei. The prevalence (confidence interval) of difficult-to-culture species was as follows: Dialister invisus, 17% (7%-29%); Solobacterium moorei, 14% (8%-23%); Bacteroidaceae [G-1] bacterium HMT 272, 13% (5%-23%); and Filifactor alocis, 11% (3%-23%). CONCLUSIONS: The prevalence of as-yet-uncultivated/difficult-to-culture bacterial taxa in post-instrumentation samples was low. The persistent species belonged mainly to the phylum Firmicutes, and streptococci were the major members. Future larger clinical studies on the composition of the whole bacterial community that persist after CMP are still necessary for a better understanding of bacterial interactions and their clinical significance in the treatment outcome.


Asunto(s)
Cavidad Pulpar , Periodontitis Periapical , Humanos , Bacterias , Cavidad Pulpar/microbiología , ADN Bacteriano/análisis , Firmicutes , Periodontitis Periapical/terapia , Prevalencia , Preparación del Conducto Radicular/métodos
17.
J Dent Educ ; 86(6): 751-758, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35061917

RESUMEN

OBJECTIVES: The aim of this cross-sectional retrospective study was to evaluate radiographically the technical quality of root canal treatment performed by undergraduate students using reciprocating NiTi instrumentation and single-cone obturation. METHODS: Endodontic treatment on 1102 teeth performed by undergraduate students from the School of Dentistry of the University of Santa Cecilia (Brazil) was evaluated. All root canal preparations were performed using Reciproc files and were irrigated with 1% NaOCl. The root canal was filled with gutta-percha, along with AH Plus sealer, using the single-cone obturation technique. The technical quality of the root canal treatment was evaluated based on immediate postoperative radiographs. Distance between the end of the filling and the radiographic apex, the filling density, and the taper of the root filling was assessed. Inter-examiner agreement statistic (Kappa) and Chi-square statistic test were used for statistical evaluation of the results. Differences were considered statistically significant when p < 0.05. RESULTS: Anterior teeth, maxillary premolars, and molars presented better results than mandibular premolars and molars (p < 0.05). Mandibular premolars presented a high incidence of a short length of obturation (33.34%) and mandibular molars presented a high incidence of overfilling (6.55%). The majority of the treatment analyzed (62.46%) fulfilled all the criteria showing acceptable working length, taper, and density of obturation. Instrument fractures occurred in eighteen root canals (0.81%). CONCLUSIONS: The use of NiTi reciprocating instruments with the single-cone obturation technique provided an acceptable quality of endodontic treatment in the majority of the cases performed by undergraduate students.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Obturación del Conducto Radicular , Estudios Transversales , Cavidad Pulpar , Humanos , Estudios Retrospectivos , Materiales de Obturación del Conducto Radicular/uso terapéutico , Obturación del Conducto Radicular/métodos , Preparación del Conducto Radicular , Estudiantes
18.
J Conserv Dent ; 25(6): 596-599, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36591588

RESUMEN

Context: Manufacturers have produced a wide variety of nickel-titanium (NiTi) alloys, but the available literature is limited on the accuracy of some integrated electronic apex locators (EAL) used with different NiTi heat treatments in working length (WL) determination. Aim: This study aims to evaluate ex vivo , the influence of different heat treatments of NiTi instruments, and the diameter of the apical preparation on the accuracy of an EAL used during root canal preparation using an integrated EAL and motor unit. Materials and Methods: Nineteen extracted human mandibular incisors were included in the study. The WL control was determined by the visual method. Instruments of Mtwo, Reciproc, Reciproc Blue, WaveOne Gold, Twisted File Adaptive, and Hyflex CM systems, with diameters from 0.25 mm to 0.50 mm, were used to measure WL during root canal preparation. The electrical resistivity of instruments with a diameter of 0.25 mm from each system was evaluated using an Inductance, Capacitance, and Resistance (LCR) meter. Statistical Analysis Used: Data were statistically analyzed using Fisher's exact test and Kruskal-Wallis test. Results: The different heat treatments and different diameters did not influence the precision of the EAL (P > 0.05). Conclusion: The heat treatment and the diameter of the apical preparation did not influence the accuracy of WL determination by an EAL integrated with the endodontic motor.

19.
J Mech Behav Biomed Mater ; 125: 104971, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34798534

RESUMEN

OBJECTIVE: This study evaluated the influence of adding bioactive glasses particles [Niobophosphate (NbG) or bioglass (45S5)] into endodontic cements in relation to physical, chemical and biological properties. METHODS: The following commercial cements were used as comparison: AH Plus (Dentsply), Endofill (Dentsply), MTA Fillapex (Angelus) and EndoSequence (BC Sealer, Brasseler). Setting time, radiopacity, flow rate, weight loss/variation, alkaline capacity (pH) at different time-intervals (24h/48h/7d/14d/28d), bioactivity (assessed under SEM/EDS, FTIR/ATR and XDR) and cell viability were measured. Data were analyzed by One-way ANOVA/Holm-Sidak post-test (α = 5%) (normal distribution) and Kruskal-Wallis/Students-Newman-Keuls post-test (α = 5%) (non-normal distribution). RESULTS: Bioactive endodontic experimental cements (containing NbG or 45S5) had high alkalinization capacity. The experimental cements presented high weight loss/variation (p < 0.001). 45S5 experimental cement did not present radiopacity (p < 0.001). AH Plus had the lowest cell cytotoxicity when compared to the other tested cements (p < 0.001). Regarding bioactivity, SEM/EDS analyses showed precipitates with high concentrations of Ca/P for 45S5 and NbG, as well as for MTA Fillapex and BC Sealer. AH plus and Endofill did not present bioactive precipitates. FTIR/ATR and XDR analyses found hydroxyapatite precursors for NbG, 45S5, MTA Fillapex and BC Sealer. SIGNIFICANCE: The incorporation of bioactive particles (NbG or 45S5) into endodontic cements had potential to neutralize acidic environments and induced formation of hydroxyapatite precursors. Clinically, these would produce a cement that is bactericidal and have the potential to improve tissue healing. The improved radiopacity and flowability would facilitate the visualization of the material in the radiograph and the filling of anatomical complexities during root canal obturation. As drawbacks, the excessive weight loss and post-setting cytotoxicity could result in clinical degradation of the cement and adjacent tissue irritation for the patient.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Cementos para Huesos , Durapatita , Cementos de Ionómero Vítreo , Humanos
20.
Comput Biol Med ; 136: 104679, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34325229

RESUMEN

BACKGROUND: The appearance of high-density root obturating materials, such as gutta-percha and intracanal posts, on cone-beam computed tomography (CBCT) scans is substantially different from that seen in the specimen. This study evaluated the effectiveness of different CBCT software in the reduction of blooming artifacts when examining teeth with intracanal posts. METHOD: The sample included 42 human single-rooted teeth with two types of posts: G1 - low-fusion alloy posts; G2 - gold alloy posts. CBCT scans were obtained using two scanners, PreXion 3D Elite® and Carestream 9000C 3D®. First, the posts were measured using a digital micrometer (standard reference, control). Post diameters were determined using the Blooming Artifact Reduction (BAR) tool of the e-Vol DX software and of the PreXion3D Image Analysis System. Statistical data were evaluated using the van Der Waerden nonparametric analysis of variance and, after that, normalized data were analyzed using the Tukey test. The level of significance was set at α = 5 %. RESULTS: There were no significant differences (p > 0.05) between the diameters of intracanal posts on the CT scans when the e-Vol DX was used, or when these results were compared with those obtained using a micrometer. There were significant differences in post diameters determined using the PreXion3D Image Analysis System when compared with the e-Vol DX and the micrometer values (p < 0.05). CONCLUSIONS: The use of the e-Vol DX BAR filter eliminated blooming artifacts. There were no dimensional changes in the CBCT images of the low-fusion and gold alloy intracanal posts using the e-Vol DX BAR filter.


Asunto(s)
Diente no Vital , Artefactos , Tomografía Computarizada de Haz Cónico , Humanos , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...