Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
2.
Artículo en Inglés | MEDLINE | ID: mdl-38763431

RESUMEN

OBJECTIVE: Individuals with chronic pain due to knee osteoarthritis (OA) are insufficiently physically active, and alterations of facilitatory and inhibitory nociceptive signaling are common in this population. Our objective was to examine the association of these alterations in nociceptive signaling with objective accelerometer-based measures of physical activity in a large observational cohort. DESIGN: We used data from the Multicenter Osteoarthritis Study (MOST). Measures of peripheral and central pain sensitivity included pressure pain threshold (PPT) at the knee and mechanical temporal summation (TS) at the wrist, respectively. The presence of descending pain inhibition was assessed by conditioned pain modulation (CPM). Physical activity was quantitatively assessed over 7-days using a lower back-worn activity monitor. Summary metrics included steps/day, activity intensity, and sedentary time. Linear regression analyses were used to evaluate the association of pain sensitivity and the presence of descending pain inhibition with physical activity measures. RESULTS: Data from 1,873 participants was analyzed (55.9% female, age = 62.8±10.0 years). People having greater peripheral and central sensitivity showed lower step counts. CPM was not significantly related to any of the physical activity measures, and none of the exposures were significantly related to sedentary time. CONCLUSIONS: In this cohort, greater peripheral and central sensitivity were associated with reduced levels of objectively-assessed daily step counts. Further research may investigate ways to modify or treat heightened pain sensitivity as a means to increase physical activity in older adults with knee OA.

3.
JMIR Form Res ; 8: e50035, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691395

RESUMEN

BACKGROUND: Wrist-worn inertial sensors are used in digital health for evaluating mobility in real-world environments. Preceding the estimation of spatiotemporal gait parameters within long-term recordings, gait detection is an important step to identify regions of interest where gait occurs, which requires robust algorithms due to the complexity of arm movements. While algorithms exist for other sensor positions, a comparative validation of algorithms applied to the wrist position on real-world data sets across different disease populations is missing. Furthermore, gait detection performance differences between the wrist and lower back position have not yet been explored but could yield valuable information regarding sensor position choice in clinical studies. OBJECTIVE: The aim of this study was to validate gait sequence (GS) detection algorithms developed for the wrist position against reference data acquired in a real-world context. In addition, this study aimed to compare the performance of algorithms applied to the wrist position to those applied to lower back-worn inertial sensors. METHODS: Participants with Parkinson disease, multiple sclerosis, proximal femoral fracture (hip fracture recovery), chronic obstructive pulmonary disease, and congestive heart failure and healthy older adults (N=83) were monitored for 2.5 hours in the real-world using inertial sensors on the wrist, lower back, and feet including pressure insoles and infrared distance sensors as reference. In total, 10 algorithms for wrist-based gait detection were validated against a multisensor reference system and compared to gait detection performance using lower back-worn inertial sensors. RESULTS: The best-performing GS detection algorithm for the wrist showed a mean (per disease group) sensitivity ranging between 0.55 (SD 0.29) and 0.81 (SD 0.09) and a mean (per disease group) specificity ranging between 0.95 (SD 0.06) and 0.98 (SD 0.02). The mean relative absolute error of estimated walking time ranged between 8.9% (SD 7.1%) and 32.7% (SD 19.2%) per disease group for this algorithm as compared to the reference system. Gait detection performance from the best algorithm applied to the wrist inertial sensors was lower than for the best algorithms applied to the lower back, which yielded mean sensitivity between 0.71 (SD 0.12) and 0.91 (SD 0.04), mean specificity between 0.96 (SD 0.03) and 0.99 (SD 0.01), and a mean relative absolute error of estimated walking time between 6.3% (SD 5.4%) and 23.5% (SD 13%). Performance was lower in disease groups with major gait impairments (eg, patients recovering from hip fracture) and for patients using bilateral walking aids. CONCLUSIONS: Algorithms applied to the wrist position can detect GSs with high performance in real-world environments. Those periods of interest in real-world recordings can facilitate gait parameter extraction and allow the quantification of gait duration distribution in everyday life. Our findings allow taking informed decisions on alternative positions for gait recording in clinical studies and public health. TRIAL REGISTRATION: ISRCTN Registry 12246987; https://www.isrctn.com/ISRCTN12246987. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2021-050785.

4.
J Neurol ; 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38693308

RESUMEN

BACKGROUND: Trait and state physical fatigue (trait-PF and state-PF) negatively impact many people with multiple sclerosis (pwMS) but are challenging symptoms to measure. In this observational study, we explored the role of specific gait and autonomic nervous system (ANS) measures (i.e., heart rate, HR, r-r interval, R-R, HR variability, HRV) in trait-PF and state-PF. METHODS: Forty-eight pwMS [42 ± 1.9 years, 65% female, EDSS 2 (IQR: 0-5.5)] completed the Timed Up and Go test (simple and with dual task, TUG-DT) and the 6-min walk test (6MWT). ANS measures were measured via a POLAR H10 strap. Gait was measured using inertial-measurement units (OPALs, APDM Inc). Trait-PF was evaluated via the Modified Fatigue Impact Scale (MFIS) motor component. State-PF was evaluated via a Visual Analog Scale (VAS) scale before and after the completion of the 6MWT. Multiple linear regression models identified trait-PF and state-PF predictors. RESULTS: Both HR and gait metrics were associated with trait-PF and state-PF. HRV at rest was associated only with state-PF. In models based on the first 3 min of the 6MWT, double support (%) and cadence explained 47% of the trait-PF variance; % change in R-R explained 43% of the state-PF variance. Models based on resting R-R and TUG-DT explained 39% of the state-PF. DISCUSSION: These findings demonstrate that specific gait measures better capture trait-PF, while ANS metrics better capture state-PF. To capture both physical fatigue aspects, the first 3 min of the 6MWT are sufficient. Alternatively, TUG-DT and ANS rest metrics can be used for state-PF prediction in pwMS when the 6MWT is not feasible.

5.
Artículo en Inglés | MEDLINE | ID: mdl-38523250

RESUMEN

OBJECTIVE: The objective of this study was to identify gait alterations related to worsening knee pain and worsening physical function, using machine learning approaches applied to wearable sensor-derived data from a large observational cohort. METHODS: Participants in the Multicenter Osteoarthritis Study (MOST) completed a 20-m walk test wearing inertial sensors on their lower back and ankles. Parameters describing spatiotemporal features of gait were extracted from these data. We used an ensemble machine learning technique ("super learning") to optimally discriminate between those with and without worsening physical function and, separately, those with and without worsening pain over two years. We then used log-binomial regression to evaluate associations of the top 10 influential variables selected with super learning with each outcome. We also assessed whether the relation of altered gait with worsening function was mediated by changes in pain. RESULTS: Of 2,324 participants, 29% and 24% had worsening knee pain and function over two years, respectively. From the super learner, several gait parameters were found to be influential for worsening pain and for worsening function. After adjusting for confounders, greater gait asymmetry, longer average step length, and lower dominant frequency were associated with worsening pain, and lower cadence was associated with worsening function. Worsening pain partially mediated the association of cadence with function. CONCLUSION: We identified gait alterations associated with worsening knee pain and those associated with worsening physical function. These alterations could be assessed with wearable sensors in clinical settings. Further research should determine whether they might be therapeutic targets to prevent worsening pain and worsening function.

6.
Sci Rep ; 14(1): 1754, 2024 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-38243008

RESUMEN

This study aimed to validate a wearable device's walking speed estimation pipeline, considering complexity, speed, and walking bout duration. The goal was to provide recommendations on the use of wearable devices for real-world mobility analysis. Participants with Parkinson's Disease, Multiple Sclerosis, Proximal Femoral Fracture, Chronic Obstructive Pulmonary Disease, Congestive Heart Failure, and healthy older adults (n = 97) were monitored in the laboratory and the real-world (2.5 h), using a lower back wearable device. Two walking speed estimation pipelines were validated across 4408/1298 (2.5 h/laboratory) detected walking bouts, compared to 4620/1365 bouts detected by a multi-sensor reference system. In the laboratory, the mean absolute error (MAE) and mean relative error (MRE) for walking speed estimation ranged from 0.06 to 0.12 m/s and - 2.1 to 14.4%, with ICCs (Intraclass correlation coefficients) between good (0.79) and excellent (0.91). Real-world MAE ranged from 0.09 to 0.13, MARE from 1.3 to 22.7%, with ICCs indicating moderate (0.57) to good (0.88) agreement. Lower errors were observed for cohorts without major gait impairments, less complex tasks, and longer walking bouts. The analytical pipelines demonstrated moderate to good accuracy in estimating walking speed. Accuracy depended on confounding factors, emphasizing the need for robust technical validation before clinical application.Trial registration: ISRCTN - 12246987.


Asunto(s)
Velocidad al Caminar , Dispositivos Electrónicos Vestibles , Humanos , Anciano , Marcha , Caminata , Proyectos de Investigación
7.
Mov Disord ; 39(2): 328-338, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38151859

RESUMEN

BACKGROUND: Real-world monitoring using wearable sensors has enormous potential for assessing disease severity and symptoms among persons with Parkinson's disease (PD). Many distinct features can be extracted, reflecting multiple mobility domains. However, it is unclear which digital measures are related to PD severity and are sensitive to disease progression. OBJECTIVES: The aim was to identify real-world mobility measures that reflect PD severity and show discriminant ability and sensitivity to disease progression, compared to the Movement Disorder Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) scale. METHODS: Multicenter real-world continuous (24/7) digital mobility data from 587 persons with PD and 68 matched healthy controls were collected using an accelerometer adhered to the lower back. Machine learning feature selection and regression algorithms evaluated associations of the digital measures using the MDS-UPDRS (I-III). Binary logistic regression assessed discriminatory value using controls, and longitudinal observational data from a subgroup (n = 33) evaluated sensitivity to change over time. RESULTS: Digital measures were only moderately correlated with the MDS-UPDRS (part II-r = 0.60 and parts I and III-r = 0.50). Most associated measures reflected activity quantity and distribution patterns. A model with 14 digital measures accurately distinguished recently diagnosed persons with PD from healthy controls (81.1%, area under the curve: 0.87); digital measures showed larger effect sizes (Cohen's d: [0.19-0.66]), for change over time than any of the MDS-UPDRS parts (Cohen's d: [0.04-0.12]). CONCLUSIONS: Real-world mobility measures are moderately associated with clinical assessments, suggesting that they capture different aspects of motor capacity and function. Digital mobility measures are sensitive to early-stage disease and to disease progression, to a larger degree than conventional clinical assessments, demonstrating their utility, primarily for clinical trials but ultimately also for clinical care. © 2023 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.


Asunto(s)
Enfermedad de Parkinson , Humanos , Enfermedad de Parkinson/complicaciones , Pruebas de Estado Mental y Demencia , Modelos Logísticos , Índice de Severidad de la Enfermedad , Progresión de la Enfermedad
8.
Front Neurol ; 14: 1247532, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37909030

RESUMEN

Introduction: The clinical assessment of mobility, and walking specifically, is still mainly based on functional tests that lack ecological validity. Thanks to inertial measurement units (IMUs), gait analysis is shifting to unsupervised monitoring in naturalistic and unconstrained settings. However, the extraction of clinically relevant gait parameters from IMU data often depends on heuristics-based algorithms that rely on empirically determined thresholds. These were mainly validated on small cohorts in supervised settings. Methods: Here, a deep learning (DL) algorithm was developed and validated for gait event detection in a heterogeneous population of different mobility-limiting disease cohorts and a cohort of healthy adults. Participants wore pressure insoles and IMUs on both feet for 2.5 h in their habitual environment. The raw accelerometer and gyroscope data from both feet were used as input to a deep convolutional neural network, while reference timings for gait events were based on the combined IMU and pressure insoles data. Results and discussion: The results showed a high-detection performance for initial contacts (ICs) (recall: 98%, precision: 96%) and final contacts (FCs) (recall: 99%, precision: 94%) and a maximum median time error of -0.02 s for ICs and 0.03 s for FCs. Subsequently derived temporal gait parameters were in good agreement with a pressure insoles-based reference with a maximum mean difference of 0.07, -0.07, and <0.01 s for stance, swing, and stride time, respectively. Thus, the DL algorithm is considered successful in detecting gait events in ecologically valid environments across different mobility-limiting diseases.

9.
J Neuroeng Rehabil ; 20(1): 78, 2023 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-37316858

RESUMEN

BACKGROUND: Although digital mobility outcomes (DMOs) can be readily calculated from real-world data collected with wearable devices and ad-hoc algorithms, technical validation is still required. The aim of this paper is to comparatively assess and validate DMOs estimated using real-world gait data from six different cohorts, focusing on gait sequence detection, foot initial contact detection (ICD), cadence (CAD) and stride length (SL) estimates. METHODS: Twenty healthy older adults, 20 people with Parkinson's disease, 20 with multiple sclerosis, 19 with proximal femoral fracture, 17 with chronic obstructive pulmonary disease and 12 with congestive heart failure were monitored for 2.5 h in the real-world, using a single wearable device worn on the lower back. A reference system combining inertial modules with distance sensors and pressure insoles was used for comparison of DMOs from the single wearable device. We assessed and validated three algorithms for gait sequence detection, four for ICD, three for CAD and four for SL by concurrently comparing their performances (e.g., accuracy, specificity, sensitivity, absolute and relative errors). Additionally, the effects of walking bout (WB) speed and duration on algorithm performance were investigated. RESULTS: We identified two cohort-specific top performing algorithms for gait sequence detection and CAD, and a single best for ICD and SL. Best gait sequence detection algorithms showed good performances (sensitivity > 0.73, positive predictive values > 0.75, specificity > 0.95, accuracy > 0.94). ICD and CAD algorithms presented excellent results, with sensitivity > 0.79, positive predictive values > 0.89 and relative errors < 11% for ICD and < 8.5% for CAD. The best identified SL algorithm showed lower performances than other DMOs (absolute error < 0.21 m). Lower performances across all DMOs were found for the cohort with most severe gait impairments (proximal femoral fracture). Algorithms' performances were lower for short walking bouts; slower gait speeds (< 0.5 m/s) resulted in reduced performance of the CAD and SL algorithms. CONCLUSIONS: Overall, the identified algorithms enabled a robust estimation of key DMOs. Our findings showed that the choice of algorithm for estimation of gait sequence detection and CAD should be cohort-specific (e.g., slow walkers and with gait impairments). Short walking bout length and slow walking speed worsened algorithms' performances. Trial registration ISRCTN - 12246987.


Asunto(s)
Tecnología Digital , Fracturas Femorales Proximales , Humanos , Anciano , Marcha , Caminata , Velocidad al Caminar , Modalidades de Fisioterapia
10.
Front Bioeng Biotechnol ; 11: 1143248, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37214281

RESUMEN

Introduction: Accurately assessing people's gait, especially in real-world conditions and in case of impaired mobility, is still a challenge due to intrinsic and extrinsic factors resulting in gait complexity. To improve the estimation of gait-related digital mobility outcomes (DMOs) in real-world scenarios, this study presents a wearable multi-sensor system (INDIP), integrating complementary sensing approaches (two plantar pressure insoles, three inertial units and two distance sensors). Methods: The INDIP technical validity was assessed against stereophotogrammetry during a laboratory experimental protocol comprising structured tests (including continuous curvilinear and rectilinear walking and steps) and a simulation of daily-life activities (including intermittent gait and short walking bouts). To evaluate its performance on various gait patterns, data were collected on 128 participants from seven cohorts: healthy young and older adults, patients with Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease, congestive heart failure, and proximal femur fracture. Moreover, INDIP usability was evaluated by recording 2.5-h of real-world unsupervised activity. Results and discussion: Excellent absolute agreement (ICC >0.95) and very limited mean absolute errors were observed for all cohorts and digital mobility outcomes (cadence ≤0.61 steps/min, stride length ≤0.02 m, walking speed ≤0.02 m/s) in the structured tests. Larger, but limited, errors were observed during the daily-life simulation (cadence 2.72-4.87 steps/min, stride length 0.04-0.06 m, walking speed 0.03-0.05 m/s). Neither major technical nor usability issues were declared during the 2.5-h acquisitions. Therefore, the INDIP system can be considered a valid and feasible solution to collect reference data for analyzing gait in real-world conditions.

11.
Med Biol Eng Comput ; 61(9): 2341-2352, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37069465

RESUMEN

Walking activity and gait parameters are considered among the most relevant mobility-related parameters. Currently, gait assessments have been mainly analyzed in laboratory or hospital settings, which only partially reflect usual performance (i.e., real world behavior). In this study, we aim to validate a robust walking detection algorithm using a single foot-worn inertial measurement unit (IMU) in real-life settings. We used a challenging dataset including 18 individuals performing free-living activities. A multi-sensor wearable system including pressure insoles, multiple IMUs, and infrared distance sensors (INDIP) was used as reference. Accurate walking detection was obtained, with sensitivity and specificity of 98 and 91% respectively. As robust walking detection is needed for ambulatory monitoring to complete the processing pipeline from raw recorded data to walking/mobility outcomes, a validated algorithm would pave the way for assessing patient performance and gait quality in real-world conditions.


Asunto(s)
Marcha , Caminata , Humanos , Pie , Monitoreo Ambulatorio , Algoritmos
12.
Digit Health ; 9: 20552076221150745, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36756644

RESUMEN

Background: This study aimed to explore the acceptability of a wearable device for remotely measuring mobility in the Mobilise-D technical validation study (TVS), and to explore the acceptability of using digital tools to monitor health. Methods: Participants (N = 106) in the TVS wore a waist-worn device (McRoberts Dynaport MM + ) for one week. Following this, acceptability of the device was measured using two questionnaires: The Comfort Rating Scale (CRS) and a previously validated questionnaire. A subset of participants (n = 36) also completed semi-structured interviews to further determine device acceptability and to explore their opinions of the use of digital tools to monitor their health. Questionnaire results were analysed descriptively and interviews using a content analysis. Results: The device was considered both comfortable (median CRS (IQR; min-max) = 0.0 (0.0; 0-20) on a scale from 0-20 where lower scores signify better comfort) and acceptable (5.0 (0.5; 3.0-5.0) on a scale from 1-5 where higher scores signify better acceptability). Interviews showed it was easy to use, did not interfere with daily activities, and was comfortable. The following themes emerged from participants' as being important to digital technology: altered expectations for themselves, the use of technology, trust, and communication with healthcare professionals. Conclusions: Digital tools may bridge existing communication gaps between patients and clinicians and participants are open to this. This work indicates that waist-worn devices are supported, but further work with patient advisors should be undertaken to understand some of the key issues highlighted. This will form part of the ongoing work of the Mobilise-D consortium.

13.
Sci Data ; 10(1): 38, 2023 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-36658136

RESUMEN

Wearable devices are used in movement analysis and physical activity research to extract clinically relevant information about an individual's mobility. Still, heterogeneity in protocols, sensor characteristics, data formats, and gold standards represent a barrier for data sharing, reproducibility, and external validation. In this study, we aim at providing an example of how movement data (from the real-world and the laboratory) recorded from different wearables and gold standard technologies can be organized, integrated, and stored. We leveraged on our experience from a large multi-centric study (Mobilise-D) to provide guidelines that can prove useful to access, understand, and re-use the data that will be made available from the study. These guidelines highlight the encountered challenges and the adopted solutions with the final aim of supporting standardization and integration of data in other studies and, in turn, to increase and facilitate comparison of data recorded in the scientific community. We also provide samples of standardized data, so that both the structure of the data and the procedure can be easily understood and reproduced.

14.
Gerontology ; 69(4): 513-518, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36470231

RESUMEN

BACKGROUND: The performance of an attention-demanding task while walking, i.e., dual-tasking, leads to dual-task costs (e.g., reduced gait speed) in older adults. Previous studies have shown that dual-task costs in gait are associated with future falls and cognitive decline. According to the communication through coherence hypothesis, transcranial alternating current stimulation (tACS) might help alleviate this problem. OBJECTIVE: The aim of this study was to examine the effects of a single session of theta-tACS targeting the left fronto-parietal network (L-FPN) on dual-task walking and cognitive function compared to sham stimulation and transcranial direct current stimulation (tDCS) targeting the left dorsolateral prefrontal cortex, a node within the L-FPN. METHODS: Twenty older adults completed a four-visit, double-blinded, within-subject, cross-over study in which usual-walking, dual-task walking, and cognitive function were evaluated before and immediately after 20 min of tACS, tDCS, or sham (order randomized) stimulation. Dual-task costs to gait speed (primary outcome) and other measures were analyzed. RESULTS: The dual-task cost to gait speed tended to be lower (i.e., better) after tACS (p = 0.067, Cohen's d = 0.433∼small); tDCS significantly reduced this dual-task cost (p = 0.012, Cohen's d = 0.618∼medium), and sham stimulation had no effect (p = 0.467). tACS significantly reduced the dual-task cost to step length (p = 0.037, Cohen's d = 0.502∼medium); a trend was seen after tDCS (p = 0.069, Cohen's d = 0.443∼small). No statistical differences were found for other measures of gait or cognitive function. CONCLUSIONS: The positive effects of tACS on dual-task gait speed and step length were roughly similar to those seen with tDCS. These results suggest that tACS affects the fronto-parietal network and, similar to tDCS, tACS may improve dual-tasking. Nonetheless, to achieve larger benefits and differentiate the effects of tACS and tDCS on brain function and dual-task walking in older adults, other stimulation montages and protocols should be tested.


Asunto(s)
Marcha , Estimulación Transcraneal de Corriente Directa , Anciano , Humanos , Estudios Cruzados , Marcha/fisiología , Proyectos Piloto , Estimulación Transcraneal de Corriente Directa/métodos
15.
J Neuroeng Rehabil ; 19(1): 141, 2022 12 16.
Artículo en Inglés | MEDLINE | ID: mdl-36522646

RESUMEN

BACKGROUND: Measuring mobility in daily life entails dealing with confounding factors arising from multiple sources, including pathological characteristics, patient specific walking strategies, environment/context, and purpose of the task. The primary aim of this study is to propose and validate a protocol for simulating real-world gait accounting for all these factors within a single set of observations, while ensuring minimisation of participant burden and safety. METHODS: The protocol included eight motor tasks at varying speed, incline/steps, surface, path shape, cognitive demand, and included postures that may abruptly alter the participants' strategy of walking. It was deployed in a convenience sample of 108 participants recruited from six cohorts that included older healthy adults (HA) and participants with potentially altered mobility due to Parkinson's disease (PD), multiple sclerosis (MS), proximal femoral fracture (PFF), chronic obstructive pulmonary disease (COPD) or congestive heart failure (CHF). A novelty introduced in the protocol was the tiered approach to increase difficulty both within the same task (e.g., by allowing use of aids or armrests) and across tasks. RESULTS: The protocol proved to be safe and feasible (all participants could complete it and no adverse events were recorded) and the addition of the more complex tasks allowed a much greater spread in walking speeds to be achieved compared to standard straight walking trials. Furthermore, it allowed a representation of a variety of daily life relevant mobility aspects and can therefore be used for the validation of monitoring devices used in real life. CONCLUSIONS: The protocol allowed for measuring gait in a variety of pathological conditions suggests that it can also be used to detect changes in gait due to, for example, the onset or progression of a disease, or due to therapy. TRIAL REGISTRATION: ISRCTN-12246987.


Asunto(s)
Marcha , Enfermedad de Parkinson , Adulto , Humanos , Caminata , Velocidad al Caminar , Proyectos de Investigación
16.
Sci Rep ; 12(1): 22200, 2022 12 23.
Artículo en Inglés | MEDLINE | ID: mdl-36564397

RESUMEN

Gait alterations in those with mild unilateral knee pain during walking may provide clues to modifiable alterations that affect progression of knee pain and osteoarthritis (OA). To examine this, we applied machine learning (ML) approaches to gait data from wearable sensors in a large observational knee OA cohort, the Multicenter Osteoarthritis (MOST) study. Participants completed a 20-m walk test wearing sensors on their trunk and ankles. Parameters describing spatiotemporal features of gait and symmetry, variability and complexity were extracted. We used an ensemble ML technique ("super learning") to identify gait variables in our cross-sectional data associated with the presence/absence of unilateral knee pain. We then used logistic regression to determine the association of selected gait variables with odds of mild knee pain. Of 2066 participants (mean age 63.6 [SD: 10.4] years, 56% female), 21.3% had mild unilateral pain while walking. Gait parameters selected in the ML process as influential included step regularity, sample entropy, gait speed, and amplitude dominant frequency, among others. In adjusted cross-sectional analyses, lower levels of step regularity (i.e., greater gait variability) and lower sample entropy(i.e., lower gait complexity) were associated with increased likelihood of unilateral mild pain while walking [aOR 0.80 (0.64-1.00) and aOR 0.79 (0.66-0.95), respectively].


Asunto(s)
Marcha , Osteoartritis de la Rodilla , Humanos , Femenino , Persona de Mediana Edad , Masculino , Estudios Transversales , Caminata , Articulación de la Rodilla , Dolor , Aprendizaje Automático , Fenómenos Biomecánicos
17.
Mult Scler Relat Disord ; 68: 104108, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36063732

RESUMEN

BACKGROUND: Physical activity is lower in people with multiple sclerosis (pwMS) compared to healthy controls. Previous work focused on studying activity levels or activity volume, but studies of daily-living rest-activity fragmentation patterns, circadian rhythms, and fractal regulation in pwMS are limited. Based on findings in other cohorts, one could suggest that these aspects of daily-living physical activity will provide additional information about the health and well-being of pwMS. Therefore, here, we aimed to (1) identify which fragmentation, fractal, and circadian amplitude measures differ between pwMS and healthy controls, (2) evaluate the relationship between fragmentation, fractal, and circadian amplitude measures and disease severity, and (3) begin to evaluate the added value of those measures, as compared to more conventional measures of physical activity (e.g., mean signal vector magnitude (SVM). A global measure of the overall volume of physical activity). METHODS: 132 people with relapsing-remitting MS (47±11 yrs, 69.7% female, Expanded Disability Status Scale, EDSS, median (IQR): 3 (2-4)) and 90 healthy controls (46±11 yrs, 47.8% female) were asked to wear a 3D accelerometer on their lower back for 7 days. Rest-activity fragmentation, circadian amplitude, fractal regulation, and mean SVM metrics were extracted. PwMS and healthy controls were compared using independent samples t-tests and linear regression, including comparisons adjusted for mean SVM to control for the effect of physical activity volume. Spearman correlations between measures and logistic regressions were used to identify the clinical condition based on the measures that differed significantly after adjusting for SVM. All analyses included adjustments for demographic and clinical parameters (e.g., age, sex). RESULTS: Multiple measures of activity fragmentation significantly differed between pwMS and healthy controls, reflecting a more fragmented active behavior in pwMS. PwMS had a lower circadian rhythm amplitude, indicating a smaller amplitude in the circadian changes of daily activity, and weaker temporal correlations as based on the fractal analysis. When taking into account physical activity volume, one circadian amplitude measure and one fractal measure remained significantly different in pwMS and controls. Fragmentation measures and circadian amplitude measures were significantly associated with disability level as measured by the EDSS; the association with circadian amplitude remained significant, even after adjusting for the mean SVM. CONCLUSION: The physical activity patterns of pwMS differ from those of healthy individuals in rest-activity fragmentation, the amplitude of the circadian rhythm, and fractal regulation. Measures describing these aspects of activity provide information that is not captured in the total volume of physical activity and could, perhaps, augment the monitoring of disease progression and evaluation of the response to interventions.


Asunto(s)
Personas con Discapacidad , Esclerosis Múltiple , Humanos , Femenino , Masculino , Ejercicio Físico , Descanso
18.
Sensors (Basel) ; 22(18)2022 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-36146441

RESUMEN

Remote assessment of the gait of older adults (OAs) during daily living using wrist-worn sensors has the potential to augment clinical care and mobility research. However, hand movements can degrade gait detection from wrist-sensor recordings. To address this challenge, we developed an anomaly detection algorithm and compared its performance to four previously published gait detection algorithms. Multiday accelerometer recordings from a wrist-worn and lower-back sensor (i.e., the "gold-standard" reference) were obtained in 30 OAs, 60% with Parkinson's disease (PD). The area under the receiver operator curve (AUC) and the area under the precision−recall curve (AUPRC) were used to evaluate the performance of the algorithms. The anomaly detection algorithm obtained AUCs of 0.80 and 0.74 for OAs and PD, respectively, but AUPRCs of 0.23 and 0.31 for OAs and PD, respectively. The best performing detection algorithm, a deep convolutional neural network (DCNN), exhibited high AUCs (i.e., 0.94 for OAs and 0.89 for PD) but lower AUPRCs (i.e., 0.66 for OAs and 0.60 for PD), indicating trade-offs between precision and recall. When choosing a classification threshold of 0.9 (i.e., opting for high precision) for the DCNN algorithm, strong correlations (r > 0.8) were observed between daily living walking time estimates based on the lower-back (reference) sensor and the wrist sensor. Further, gait quality measures were significantly different in OAs and PD compared to healthy adults. These results demonstrate that daily living gait can be quantified using a wrist-worn sensor.


Asunto(s)
Enfermedad de Parkinson , Anciano , Marcha , Humanos , Aprendizaje Automático , Enfermedad de Parkinson/diagnóstico , Caminata , Muñeca
19.
Front Bioeng Biotechnol ; 10: 868928, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35721859

RESUMEN

There is growing interest in the quantification of gait as part of complex motor tasks. This requires gait events (GEs) to be detected under conditions different from straight walking. This study aimed to propose and validate a new marker-based GE detection method, which is also suitable for curvilinear walking and step negotiation. The method was first tested against existing algorithms using data from healthy young adults (YA, n = 20) and then assessed in data from 10 individuals from the following five cohorts: older adults, chronic obstructive pulmonary disease, multiple sclerosis, Parkinson's disease, and proximal femur fracture. The propagation of the errors associated with GE detection on the calculation of stride length, duration, speed, and stance/swing durations was investigated. All participants performed a variety of motor tasks including curvilinear walking and step negotiation, while reference GEs were identified using a validated methodology exploiting pressure insole signals. Sensitivity, positive predictive values (PPV), F1-score, bias, precision, and accuracy were calculated. Absolute agreement [intraclass correlation coefficient ( I C C 2,1 )] between marker-based and pressure insole stride parameters was also tested. In the YA cohort, the proposed method outperformed the existing ones, with sensitivity, PPV, and F1 scores ≥ 99% for both GEs and conditions, with a virtually null bias (<10 ms). Overall, temporal inaccuracies minimally impacted stride duration, length, and speed (median absolute errors ≤1%). Similar algorithm performances were obtained for all the other five cohorts in GE detection and propagation to the stride parameters, where an excellent absolute agreement with the pressure insoles was also found ( I C C 2,1 = 0.817 -   0.999 ). In conclusion, the proposed method accurately detects GE from marker data under different walking conditions and for a variety of gait impairments.

20.
Sensors (Basel) ; 21(24)2021 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-34960317

RESUMEN

Optoelectronic stereophotogrammetric (SP) systems are widely used in human movement research for clinical diagnostics, interventional applications, and as a reference system for validating alternative technologies. Regardless of the application, SP systems exhibit different random and systematic errors depending on camera specifications, system setup and laboratory environment, which hinders comparing SP data between sessions and across different systems. While many methods have been proposed to quantify and report the errors of SP systems, they are rarely utilized due to their complexity and need for additional equipment. In response, an easy-to-use quality control (QC) check has been designed that can be completed immediately prior to a data collection. This QC check requires minimal training for the operator and no additional equipment. In addition, a custom graphical user interface ensures automatic processing of the errors in an easy-to-read format for immediate interpretation. On initial deployment in a multicentric study, the check (i) proved to be feasible to perform in a short timeframe with minimal burden to the operator, and (ii) quantified the level of random and systematic errors between sessions and systems, ensuring comparability of data in a variety of protocol setups, including repeated measures, longitudinal studies and multicentric studies.


Asunto(s)
Movimiento , Fotogrametría , Humanos , Control de Calidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...