Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Health Serv Res ; 24(1): 43, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38195446

RESUMEN

BACKGROUND: South Africa maintains an integrated health system where syndromic management of sexually transmitted infections (STI) is the standard of care. An estimated 2 million cases of Neisseria gonorrhoeae (N. gonorrhoeae) occur in South Africa every year. Point-of-care diagnostic tests (POCT) may address existing STI control limitations such as overtreatment and missed cases. Subsequently, a rapid lateral flow assay with fluorescence-based detection (NG-LFA) with a prototype reader was developed for N. gonorrhoeae detection showing excellent performance and high usability; however, a better understanding is needed for device implementation and integration into clinics. METHODS: A qualitative, time-series assessment using 66 in-depth interviews was conducted among 25 trained healthcare workers involved in the implementation of the NG-LFA. Findings were informed by the Normalization Process Theory (NPT) as per relevant contextual (strategic intentions, adaptive execution, and negotiation capacity) and procedural constructs (coherence, cognitive participation, collective action, reflexive monitoring) to examine device implementation within primary healthcare levels. Interviews were audio-recorded, transcribed, and then analyzed using a thematic approach guided by NPT to interpret results. RESULTS: Overall, healthcare workers agreed that STI POCT could guide better STI clinical decision-making, with consideration for clinic integration such as space constraints, patient flow, and workload. Perceived NG-LFA benefits included enhanced patient receptivity and STI knowledge. Further, healthcare workers reflected on the suitability of the NG-LFA given current limitations with integrated primary care. Recommendations included sufficient STI education, and appropriate departments for first points of entry for STI screening. CONCLUSIONS: The collective action and participation by healthcare workers in the implementation of the NG-LFA revealed adaptive execution within the current facility environment including team compositions, facility-staff receptivity, and STI management experiences. User experiences support future clinic service integration, highlighting the importance of further assessing patient-provider communication for STI care, organizational readiness, and identification of relevant departments for STI screening.


Asunto(s)
Neisseria gonorrhoeae , Sistemas de Atención de Punto , Humanos , Sudáfrica , Prueba de Diagnóstico Rápido , Pruebas en el Punto de Atención , Atención Primaria de Salud
2.
PLoS One ; 18(6): e0286666, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37267319

RESUMEN

Accurate and user-friendly rapid point-of-care diagnostic tests (POCT) are needed to optimize treatment of Neisseria gonorrhoeae, especially in low-resource settings where syndromic management is the standard of care for sexually transmitted infections. This study aimed to assess the acceptability and usability of a novel lateral flow assay and portable reader for the point-of-care detection of N. gonorrhoeae infection (NG-LFA). This mixed-methods study was conducted as part of a diagnostic performance and usability evaluation of a prototype NG-LFA for detection of N. gonorrhoeae in symptomatic men and women at primary healthcare facilities in the Buffalo City Metro, South Africa. The Standardized System Usability Scale (SUS) was administered, and in-depth interviews were conducted among healthcare professionals (HCPs) and fieldworkers (FWs) at pre-implementation, initial use and 3- and 6-month study implementation to assess user expectations, practical experience, and future implementation considerations for the NG-LFA. Data collection and analysis was guided by the Health Technology Adoption Framework, including new health technology attributes, learnability, satisfaction, and suitability. The framework was adapted to include perceived durability. A total of 21 HCPs and FWs were trained on the NG-LFA use. SUS scores showed good to excellent acceptability ranging from 78.8-90.6 mean scores between HCPs and FWs across study time points. All transcripts were coded using Dedoose and qualitative findings were organized by learnability, satisfaction, suitability, and durability domains. Usability themes are described for each time point. Initial insecurity dissipated and specimen processing dexterity with novel POCT technology was perfected over time especially amongst FWs through practical learning and easy-to-use instructions (learnability). Participants experienced both positive and negative test results, yielding perceived accuracy and minimal testing challenges overall (satisfaction). By 3- and 6-month use, both HCPs and FWs found the NG-LFA convenient to use in primary health care facilities often faced with space constraints and outlined perceived benefits for patients (suitability and durability). Findings show that the NG-LFA device is acceptable and usable even amongst paraprofessionals. High SUS scores and qualitative findings demonstrate high learnability, ease-of-use and suitability that provide valuable information for first-step scale-up requirements at primary healthcare level. Minor prototype adjustments would enhance robustness and durability aspects.


Asunto(s)
Sistemas de Atención de Punto , Enfermedades de Transmisión Sexual , Femenino , Humanos , Neisseria gonorrhoeae , Sudáfrica , Enfermedades de Transmisión Sexual/diagnóstico , Personal de Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...