Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
1.
Magn Reson Med ; 46(5): 1028-30, 2001 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11675658

RESUMEN

In this study, pulmonary MR angiography (MRA) using a tailored coil at 4 Tesla in conjunction with an intravenous injection of contrast agent is described. Three-dimensional gradient-echo images were obtained during the intravenous injection of 0.05, 0.1, and 0.2 mmol/kg body weight of gadodiamide to investigate the signal enhancement effect of the contrast agent in pulmonary arteries qualitatively and quantitatively. In the qualitative analysis, the subsegmental branches were visualized on every dose. In the quantitative analysis, the average contrast-to-noise ratios (CNRs) of the main pulmonary arteries increased in a dose-dependent manner. However, the CNRs of segmental arteries did not increase as the dose of contrast agent increased, as observed at 1.5 Tesla MRI. These observations demonstrate the feasibility of delineating the pulmonary vasculature using a contrast agent; however, our results also suggest possible high-field-related disabilities that need to be overcome before high-field (> or =4 Tesla) MRI can be used to full advantage.


Asunto(s)
Pulmón/irrigación sanguínea , Angiografía por Resonancia Magnética/métodos , Arteria Pulmonar/anatomía & histología , Adulto , Medios de Contraste , Estudios de Factibilidad , Gadolinio DTPA , Humanos , Inyecciones Intravenosas , Masculino
2.
AJR Am J Roentgenol ; 177(3): 525-8, 2001 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-11517041

RESUMEN

OBJECTIVE: The purpose of this study was to compare the diagnostic reliability of hard-copy and soft-copy interpretation of radiographs obtained in the emergency department using a methodology for evaluating imaging systems when independent proof of the diagnosis is not available. MATERIALS AND METHODS: We collected radiographs from a stratified sample of 100 patients seen in the emergency department. The images were obtained using computed radiography, and the digital images were printed on film and stored for display on a workstation. A group of seven experienced radiologists reported the cases using both film and the workstation display. The results were analyzed using mixture distribution analysis (MDA). RESULTS: The reliability expressed as the percentage of agreement of a typical observer relative to the majority was computed from the MDA. The result was 90% for both hard copy and soft copy with bootstrap confidence intervals of 86-94%. CONCLUSION: We conclude that, in the emergency department, soft-copy interpretation is as reliable as hard-copy interpretation. The strength of this conclusion depends on the validity of the MDA approach as well as the extent to which the observer sample and case sample are representative of the emergency department.


Asunto(s)
Servicio de Urgencia en Hospital , Interpretación de Imagen Asistida por Computador , Sistemas de Información Radiológica , Programas Informáticos , Tomografía Computarizada por Rayos X , Diagnóstico Diferencial , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Heridas y Lesiones/diagnóstico por imagen
3.
J Magn Reson Imaging ; 14(2): 175-80, 2001 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-11477677

RESUMEN

The continuous arterial spin-labeling (CASL) method of perfusion MRI is used to observe pulmonary perfusion dynamically in an animal model. Specifically, a respiratory-triggered implementation of the CASL method is used with approximate spatial resolution of 0.9 x 1.8 x 5.0 mm (0.008 cc) and 2-minute temporal resolution. Perfusion MRI is performed dynamically during repeated balloon occlusion of a segmental pulmonary artery, as well as during pharmacological stimulation. A total of three Yorkshire pigs were studied. The results demonstrate the ability of the endogenous spin-labeling method to characterize the dynamic changes in pulmonary perfusion that occur during important physiological alterations.


Asunto(s)
Pulmón/anatomía & histología , Imagen por Resonancia Magnética/métodos , Animales , Oclusión con Balón , Perfusión , Arteria Pulmonar , Circulación Pulmonar , Marcadores de Spin , Porcinos
4.
J Heart Valve Dis ; 10(3): 361-6, 2001 May.
Artículo en Inglés | MEDLINE | ID: mdl-11380099

RESUMEN

BACKGROUND AND AIM OF THE STUDY: Calcific aortic stenosis is common in the elderly; indeed, 30-60% of patients with mild 'senile' aortic stenosis will progress to severe obstruction. Nonetheless, predictors of progression are incompletely defined, and non-invasive technologies capable of quantifying aortic valve calcium are needed. The reliability of electron beam computed tomography (EBCT) was evaluated for quantification of aortic valve calcium content. METHODS: Nineteen patients with and without restrictive valve calcification underwent EBCT scanning. Separate calcium scores, 30 s apart, were obtained in all patients, and the Spearman correlation coefficient was calculated between measurements. The relationship between dichotomized mean calcium score and aortic valve area was also investigated. RESULTS: There was excellent correlation between calcium scores (R = 0.99, p = 0.0001), as well as a significant inverse relationship between calcium scores in the upper and lower ranges and aortic valve area (p = 0.002). CONCLUSION: EBCT can be used for reproducible quantitation of aortic valve calcification. While at their extremes, calcium scores are inversely related to aortic valve area, further evaluation is needed to define the precise nature of this relationship throughout the spectrum of stenosis severity. EBCT holds promise in the longitudinal assessment of valvular calcification progression and its response to potential medical therapies.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Ultrasonografía
5.
J Thorac Imaging ; 16(2): 76-80, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11292208

RESUMEN

This study was undertaken to evaluate the efficacy of high resolution computed tomography (HRCT) in predicting the development of bronchiolitis obliterans syndrome (BOS) in lung transplant recipients. Fifty lung transplant patients who were clinically stable and without evidence of BOS were evaluated for the presence of four HRCT features reported to be associated with bronchiolitis obliterans: mosaic attenuation on inspiratory CT (mosaic perfusion), mosaic attenuation on expiratory CT (air trapping), bronchiectasis, and tree-in-bud opacities. CT exams were part of an annual surveillance process with the hope of predicting subsequent development of BOS. Diagnosis of BOS was made in 9 of 50 patients as indicated by a fall in FEV1 of greater than 20% of a stable baseline. None of the radiographic features associated with clinically established BOS were both sensitive and specific in the prediction of BOS. Air trapping demonstrated moderate sensitivity (56%, 5/9) and moderate specificity (76%, 35/46) for prediction of BOS in the year following the CT exam. Bronchiectasis, the most reliable indicator of the presence of BOS was a poor predictor of subsequent BOS with an 11% (1/9) sensitivity but had high specificity (96%, 44/46). No high resolution CT features accurately predicted the development of BOS.


Asunto(s)
Bronquiolitis Obliterante/diagnóstico por imagen , Trasplante de Pulmón , Tomografía Computarizada por Rayos X , Adulto , Anciano , Bronquiolitis Obliterante/etiología , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pruebas de Función Respiratoria , Sensibilidad y Especificidad
6.
Radiology ; 219(1): 243-6, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11274564

RESUMEN

PURPOSE: To determine whether three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography could be used to identify pulmonary arteriovenous malformations (PAVMs) and to accurately identify the size and number of feeding arteries. MATERIALS AND METHODS: Eight patients suspected of having PAVM were examined with three-dimensional MR angiography at 1.5 T. Images were reviewed by a single radiologist blinded to conventional angiographic findings who evaluated each image for the size, number, and location of PAVMs, as well as for the size and number of feeding arteries. Five patients underwent conventional angiography with embolization therapy, and one patient underwent lobectomy. Two patients did not undergo either surgery or angiography. RESULTS: Three-dimensional MR angiography revealed nine (90%) of 10 PAVMs that were confirmed at conventional angiography (n = 9) or examination of a surgical specimen (n = 1). The single PAVM that was not identified prospectively at MR angiography was small (3-4 mm) and peripheral. Two additional PAVMs were identified in the two patients who did not undergo surgery or angiography. CONCLUSION: Three-dimensional MR angiography is a promising technique for use in the diagnosis of PAVM, although small (<5-mm) PAVMs may be more difficult to identify with the technique. The technique is a particularly useful means of noninvasively demonstrating the size and number of feeding arteries prior to treatment.


Asunto(s)
Malformaciones Arteriovenosas/diagnóstico , Aumento de la Imagen , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Arteria Pulmonar/anomalías , Venas Pulmonares/anomalías , Adolescente , Adulto , Anciano , Malformaciones Arteriovenosas/terapia , Embolización Terapéutica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neumonectomía , Estudios Prospectivos , Arteria Pulmonar/patología , Venas Pulmonares/patología
7.
Acad Radiol ; 7(10): 786-97, 2000 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-11048876

RESUMEN

RATIONALE AND OBJECTIVES: The authors performed this study to estimate, by using published data, the sensitivity and specificity of computed tomographic (CT) angiography in the evaluation of suspected acute pulmonary embolism (PE). MATERIALS AND METHODS: Summary receiver operating characteristic (ROC) curve analysis was used to determine the sensitivity and specificity of CT angiography in the diagnosis of acute PE. Pulmonary angiography was used as the diagnostic standard of reference. The authors reviewed the results of 11 independent studies published in the English-language literature between January 1992 and June 1999. RESULTS: The sensitivity of CT angiography in the diagnosis or exclusion of PE in the central pulmonary arteries (to the level of the segmental pulmonary arteries) ranged from 0.74 to 0.81 on the basis of specificities of 0.89-0.91. The sensitivity of CT angiography in the diagnosis or exclusion of PE in all pulmonary arteries (to the level of the subsegmental pulmonary arteries) was 0.68 on the basis of a specificity of 0.91. CONCLUSION: On the basis of the studies in the current literature, most of which used 5.0-mm collimation and single-detector CT, CT angiography may be less accurate in the diagnosis of PE than previously reported. With improvements in data acquisition, particularly the use of thinner section collimation and multidetector CT, and in the increased use of workstations for data analysis, the accuracy and utility of CT angiography will require continued investigation.


Asunto(s)
Angiografía/métodos , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Diagnóstico Diferencial , Humanos , Arteria Pulmonar/diagnóstico por imagen , Curva ROC , Sensibilidad y Especificidad
8.
AJR Am J Roentgenol ; 175(5): 1299-301, 2000 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-11044027

RESUMEN

OBJECTIVE: Our objective was to determine the typical distribution of thrombi in acute lower extremity deep venous thrombosis as a means of evaluating the validity of imaging techniques that only include the common femoral and popliteal veins, but not the superficial femoral vein. MATERIALS AND METHODS: The results of 2704 lower extremity venous sonograms, obtained in 2026 consecutive patients over a 4-year interval, were reviewed retrospectively. The distribution of acute deep venous thromboses across various lower extremity venous segments was analyzed for this population, which consisted of both symptomatic and asymptomatic patients. RESULTS: Of 2704 lower extremities studied with duplex sonography, acute deep venous thrombosis was identified in 269 (9.9%). Of these 269 cases, acute deep venous thrombosis was isolated to the superficial femoral vein in 60 (22.3%). The remaining 209 cases (77.7%) showed thrombus that extended into the common femoral or popliteal veins (or both). CONCLUSION: An abbreviated imaging study that evaluates only the common femoral and popliteal veins would fail to identify more than 20% of lower extremity acute deep venous thromboses in a population like ours. Although evaluation of the superficial femoral vein requires additional time and resources, evaluation of this segment may prevent a substantial number of thrombi from being missed.


Asunto(s)
Pierna/irrigación sanguínea , Angiografía por Resonancia Magnética , Tomografía Computarizada por Rayos X , Ultrasonografía Doppler Dúplex , Trombosis de la Vena/diagnóstico , Enfermedad Aguda , Vena Femoral/diagnóstico por imagen , Vena Femoral/patología , Humanos , Vena Poplítea/diagnóstico por imagen , Vena Poplítea/patología , Flujo Sanguíneo Regional/fisiología , Estudios Retrospectivos , Sensibilidad y Especificidad
9.
J Comput Assist Tomogr ; 24(5): 813-23, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11045708

RESUMEN

PURPOSE: The purpose of this work was to determine the costs of computed tomography (CT) procedures in a large academic radiology department, including both professional (PC) and technical (TC) components, by analyzing actual resource consumption using an activity-based costing (ABC) method and comparing them with Medicare payments. METHOD: Over a 12 month period from July 1, 1996, to June 30, 1997, 1,011 CT procedures, representing 16 Physicians' Current Procedural Terminology (CPT) codes and 98.3% of CT studies performed, were carefully observed by a research assistant trained in ABC methodology. Information collected during these time and motion studies included personnel/machine time and direct materials used. Actual resource units used during the different activities in each CT procedure were valued using appropriate cost drivers. Unit values for both direct and overhead costs were calculated: the cost of an individual procedure equaled the sum of component costs. Costs were compared with PC and TC payments according to the 1997 Medicare Fee Schedule. RESULTS: Total costs of CPT codes 70450 (CT Head unenhanced), 71260 (CT Chest enhanced), and 74160 (CT Abdomen enhanced), which represented 71.2% of CT studies performed, were $189.19, $273.53, and $343.20, respectively. For all 16 nonmodified CPT codes analyzed, Medicare's professional reimbursement was less than the professional cost, whereas its technical reimbursement exceeded respective cost in 14 of the 16 codes. CONCLUSION: In the setting and time period studied, Medicare underreimbursed professional costs while overreimbursing technical costs.


Asunto(s)
Contabilidad/métodos , Asignación de Costos/métodos , Servicio de Radiología en Hospital/economía , Tomografía Computarizada por Rayos X/economía , Centros Médicos Académicos/economía , Análisis Costo-Beneficio , Costos Directos de Servicios , Costos de Hospital , Humanos , Medicare/economía , Philadelphia , Estados Unidos
20.
Magn Reson Med ; 44(3): 379-82, 2000 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-10975888

RESUMEN

Pulmonary air leaks were created in the lungs of Yorkshire pigs. Dynamic, 3D MRI of laser-polarized (3)He gas was then performed using a gradient-echo pulse sequence. Coronal magnitude images of the helium distribution were acquired during gas inhalation with a voxel resolution of approximately 1.2 x 2.5 x 8 mm, and a time resolution of 5 sec. In each animal, the ventilation images reveal focal high-signal intensity within the pleural cavity at the site of the air leaks. In addition, a wedge-shaped region of increased parenchymal signal intensity was observed adjacent to the site of the air leak in one animal. (3)He MRI may prove helpful in the management of patients with pulmonary air leaks.


Asunto(s)
Helio , Imagen por Resonancia Magnética/métodos , Neumotórax/diagnóstico , Administración por Inhalación , Animales , Modelos Animales de Enfermedad , Estudios de Evaluación como Asunto , Helio/administración & dosificación , Aumento de la Imagen/métodos , Isótopos , Rayos Láser , Pulmón/patología , Pleura/patología , Respiración Artificial , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...