Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38745366

RESUMEN

In the current endovascular era, open surgery through left posterolateral thoracotomy with moderate to deep hypothermic circulatory arrest remains an alternative for treating chronic distal arch or proximal descending aortic diseases, allowing cardiovascular surgeons to definitively repair the aorta in a single stage. When utilizing this approach, this report illustrates an alternative surgical technique for antegrade body perfusion during cooling, antegrade selective cerebral perfusion and rewarming, through a prosthetic graft on the right subclavian artery. This report shows the safety and feasibility of this technique during open distal arch and/or proximal descending aortic surgery through left posterolateral thoracotomy, after shifting the patient from a supine to the right lateral decubitus position.


Asunto(s)
Aorta Torácica , Circulación Cerebrovascular , Arteria Subclavia , Toracotomía , Humanos , Arteria Subclavia/cirugía , Toracotomía/métodos , Aorta Torácica/cirugía , Circulación Cerebrovascular/fisiología , Masculino , Perfusión/métodos , Anciano , Implantación de Prótesis Vascular/métodos , Aneurisma de la Aorta Torácica/cirugía , Persona de Mediana Edad
2.
iScience ; 27(4): 109359, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38510143

RESUMEN

Epicardial adipose tissue (EAT) is a fat depot located between the myocardium and the visceral layer of the epicardium, which, owing to its location, can influence surrounding tissues and can act as a local transducer of systemic inflammation. The mechanisms upon which such influence depends on are however unclear. Given the role EAT undoubtedly has in the scheme of cardiovascular diseases (CVDs), understanding the impact of its cellular components is of upmost importance. Extracellular vesicles (EVs) constitute promising candidates to fill the gap in the knowledge concerning the unexplored mechanisms through which EAT promotes onset and progression of CVDs. Owing to their ability of transporting active biomolecules, EAT-derived EVs have been reported to be actively involved in the pathogenesis of ischemia/reperfusion injury, coronary atherosclerosis, heart failure, and atrial fibrillation. Exploring the precise functions EVs exert in this context may aid in connecting the dots between EAT and CVDs.

3.
J Cardiovasc Transl Res ; 16(4): 956-967, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37097591

RESUMEN

Coronary flow obstruction following transcatheter aortic valve-in-valve implantation (VIV-TAVI) is associated with a high mortality risk. The aim of this work was to quantify the coronary perfusion after VIV-TAVI in a high-risk aortic root anatomy. 3D printed models of small aortic root were used to simulate the implantation of a TAVI prosthesis (Portico 23) into surgical prostheses (Trifecta 19 and 21). The aortic root models were tested in a pulsatile in vitro bench setup with a coronary perfusion simulator. The tests were performed at baseline and post-VIV-TAVI procedure in aligned and misaligned commissural configurations under simulated hemodynamic rest and exercise conditions. The experimental design provided highly controllable and repeatable flow and pressure conditions. The left and right coronary mean flow did not differ significantly at pre- and post-VIV-TAVI procedure in any tested configurations. The commissural misalignment did not induce any significant alterations to the coronary flow. High-risk aortic root anatomy did not trigger coronary ostia obstruction or coronary flow alteration after transcatheter aortic valve implantation in a surgical bioprosthesis as shown from in-vitro flow loop tests.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Oclusión Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Aorta Torácica/cirugía , Falla de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Perfusión , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento
4.
Ann Biomed Eng ; 51(4): 715-725, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36151505

RESUMEN

Emerging treatments for tricuspid valve (TV) regurgitation require realistic TV pathological models for preclinical testing. The aim of this work was to investigate structural features of fresh and defrosted porcine right-heart samples as models of mild and severe functional tricuspid regurgitation (FTR) condition in ex-vivo pulsatile flow platform. Ten fresh hearts were tested ex-vivo under steady and pulsatile flow in typical right-heart loading conditions. Hemodynamics and 3D echocardiographic imaging of TV and right ventricle (RV) were acquired. Hearts were then kept frozen for 14 days, defrosted, and tested again with the same protocol. Morphometric parameters of TV and RV were derived from 3D reconstructions based on echo data. Fresh samples showed a slightly dilated TV morphology, with coaptation gaps among the leaflets. Sample freezing induced worsening of TV insufficiency, with significant (p < 0.05) increases in annulus size (annulus area and perimeter 7.7-3.1% respectively) and dilation of RV (9.5%), which led to an increase in tenting volume (123.7%). These morphologic alterations reflected into a significant increment of regurgitation fraction (27%). Together, such results suggest that fresh porcine heart samples may be a reliable ex-vivo model of mild FTR condition, which can be enhanced through freezing/thawing treatment to model a severe pathological condition.


Asunto(s)
Ecocardiografía Tridimensional , Insuficiencia de la Válvula Tricúspide , Porcinos , Animales , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Ventrículos Cardíacos
5.
Front Cardiovasc Med ; 9: 850393, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35402526

RESUMEN

The increasing incidence of calcific aortic valve disease necessitates the elaboration of new strategies to retard the progression of the pathology with an innovative solution. While the increasing diffusion of the transcatheter aortic valve replacements (TAVRs) allows a mini-invasive approach to aortic valve substitution as an alternative to conventional surgical replacement (SAVR) in an always larger patient population, TAVR implantation still has contraindications for young patients. In addition, it is liable to undergo calcification with the consequent necessity of re-intervention with conventional valve surgery or repeated implantation in the so-called TAVR-in-TAVR procedure. Inspired by applications for non-cardiac pathologies or for vascular decalcification before stenting (i.e., coronary lithotripsy), in the present study, we show the feasibility of human valve treatment with a mini-invasive device tailored to deliver shockwaves to the calcific leaflets. We provide evidence of efficient calcium deposit ruptures in human calcified leaflets treated ex vivo and the safety of the treatment in pigs. The use of this device could be helpful to perform shockwaves valvuloplasty as an option to retard TAVR/SAVR, or as a pretreatment to facilitate prosthesis implantation and minimize the occurrence of paravalvular leak.

6.
Minerva Cardiol Angiol ; 70(5): 572-580, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35332746

RESUMEN

Aortic stenosis is a highly prevalent cardiac valvular disease in adult population and increases with age. After symptoms onset in severe aortic stenosis, the prognosis begins to decline; however, new studies demonstrate an increased risk of death in patients with moderate disease. Although majority of patients with severe aortic stenosis are treated electively with surgical or transcatheter aortic valve replacement, not all patients are candidates for the interventions. Balloon aortic valvuloplasty can be used successfully as a bridge to definitive treatment or as palliative therapy in patients who are not candidates for either procedure. In this paper, we discuss and justify the current indications and contraindications for balloon aortic valvuloplasty. Additionally, the step-by-step procedure technique and most frequent complications are described. Moreover, we presented the safety and feasibility of balloon aortic valvuloplasty in 33 consecutive patients on a waiting list for transcatheter aortic valve replacement at 3 expert Italian centers during the first and second waves of COVID-19, when clinical priorities focused on hospitalized patients with pneumonia. The procedural success in this cohort of patients was achieved in 31 patients (94%). Out of the 33 patients enrolled, 15 underwent TAVR within 5±2 months from the valvuloplasty, and at 6-month follow-up a total of 2 patients died for end-stage heart failure.


Asunto(s)
Estenosis de la Válvula Aórtica , Valvuloplastia con Balón , COVID-19 , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/métodos , Brotes de Enfermedades , Humanos , Resultado del Tratamiento
7.
Eur J Cardiothorac Surg ; 61(3): 647-654, 2022 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-34363669

RESUMEN

OBJECTIVES: Commissural orientation <160° is a recognized risk factor for bicuspid aortic valve repair failure. Based on this observation, repairing this subtype of aortic valve by reorienting the 2 commissures at 180° has recently been proposed. METHODS: Nine porcine hearts with aortic annulus diameters of 25 mm were selected. A pathological model of a Sievers 1 bicuspid aortic valve was obtained by suturing the coaptation line between the left and right leaflets. Each heart underwent reimplantation procedures both in the native (120°) and the reoriented (180°) configuration. After the operation, each sample was tested on a pulse duplicator at rest (heart rate 60 beats per min) and with mild exercise (heart rate 90 beats per min) conditions. RESULTS: No statistically significant difference was noted in mean and peak transvalvular aortic gradients between the 2 configurations at rest (18.6 ± 5 vs 17.5 ± 4 for the mean aortic gradient; 42.8 ± 12.7 vs 36.3 ± 5.8 for the peak aortic gradient) but the group with the 120°-oriented commissures had significantly higher mean transaortic gradients compared to the group with the 180°-oriented commissures at initial exercise stress conditions (30.1 ± 9.1 vs 24.9 ± 3.8; p value 0.002). CONCLUSIONS: The 180° commissural reorientation of the asymmetrical bicuspid aortic valve does not improve the transvalvular aortic gradient in an acute model at rest conditions, but it could do so under stress situations. Even if it is surgically more complex and time-consuming, this approach could be a good strategy to improve long-term results, particularly in young patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas , Animales , Válvula Aórtica/patología , Insuficiencia de la Válvula Aórtica/cirugía , Humanos , Estudios Retrospectivos , Porcinos , Resultado del Tratamiento
8.
Medicina (Kaunas) ; 57(9)2021 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-34577832

RESUMEN

Background and Objectives: Aortic arch disease is still a high-risk surgical challenge despite major advances both in surgical and anesthesiological management. A combined surgical and endovascular approach has been proposed for aortic arch disease treatment to avoid hypothermia and circulatory arrest in high-risk patients. Materials and Methods: Between June 2004 and June 2021, 112 patients were referred to our department for aortic arch surgery; 38 (33.9%) patients underwent supra-aortic debranching and endovascular treatment. Of these, 21 (55%) patients underwent type I aortic arch hybrid debranching procedure and in 17 (45%) patients a type II aortic arch hybrid debranching procedure was performed. None of the patients were emergent. Results: No intra-operative deaths were recorded. In the type I aortic arch hybrid debranching patients' group, one patient died at home waiting the endovascular step, one developed ascending aortic dissection and another one developed a pseudoaneurysm at the site of the debranching at follow-up. In the type II aortic arch hybrid debranching patients' group, left carotid artery branch closure was detected at follow-up in one patient. Thirty day/in-hospital rates of adverse neurological events for both the surgical and endovascular procedures were 3% for minor stroke, with no permanent neurological deficit and 0% for permanent paraplegia/paraparesis. In 100% of the cases, the endovascular step succeeded and the type Ia endoleak rate was 0%. Conclusions: Hybrid arch surgery is a valuable option for aortic arch aneurysm treatment in patients with high surgical risk. The choice of aortic arch debranching between type I or type II is crucial and depends on anatomic and clinical patient characteristics. Further larger scale studies are needed to better define the advantages of these techniques.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Humanos , Estudios Retrospectivos , Factores de Riesgo , Stents , Resultado del Tratamiento
10.
Artículo en Inglés | MEDLINE | ID: mdl-34143578

RESUMEN

We propose a technique to minimize the neurological and systemic risks involved in rerouting the blood flow toward the brain in a "single remaining vessel" configuration with a 90% stenosis by means of complete hypothermic cerebral protection associated with normothermic systemic blood flow with a "restitutio ad integrum" of the supra-aortic trunks flow. The perfusion of the brain and the arms was almost completely separated from the systemic perfusion by the deployment 1 year before of a thoracic endoprosthesis in association with complete chronic occlusion of the brachiocephalic trunk and a functioning carotid-subclavian bypass. The Free Flow of the prosthesis, which acted as a hook, moved the calcium toward the left carotid ostium, creating a 90% stenosis with intermittent acute cerebral hypoperfusion and amaurosis. We achieved an optimal result: The patient was discharged on postoperative day 7 with no neurological problems and with patency and direct blood flow in all the supra-aortic trunks.


Asunto(s)
Aorta Torácica/cirugía , Procedimientos Endovasculares/métodos , Prótesis Vascular/efectos adversos , Tronco Braquiocefálico/cirugía , Isquemia Encefálica/etiología , Isquemia Encefálica/cirugía , Estenosis Carotídea/cirugía , Femenino , Humanos , Persona de Mediana Edad
11.
G Ital Cardiol (Rome) ; 22(5): 397-400, 2021 May.
Artículo en Italiano | MEDLINE | ID: mdl-33960983

RESUMEN

Aortic valve stenosis and aortic aneurysmal disease are increasingly prevalent with advancing age. When associated, their treatment is very challenging. A female patient with previous Tirone-David procedure presented to our hospital with acute heart failure. She was diagnosed with severe aortic stenosis, aneurysm of the aortic arch and the descending thoracic aorta. She underwent successful concomitant aortic arch TEVAR and transcatheter aortic valve repair, with optimal acute and mid-term result. Our case demonstrates that a careful pre-procedural planning, along with a good cooperation between interventional cardiologists, cardiac surgeons, radiologists and clinical cardiologists, are essential in order to guarantee an excellent outcome for the patient.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Estenosis de la Válvula Aórtica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Disección Aórtica/cirugía , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Prótesis Vascular , Femenino , Humanos , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Resultado del Tratamiento
13.
Eur J Cardiothorac Surg ; 58(5): 940-948, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32728726

RESUMEN

OBJECTIVES: Our goal was to report the midterm results of hybrid treatment of extensive thoracic aortic aneurysm (ETAA) with the completion of thoracic endovascular aortic repair after proximal ascending-arch graft replacement. METHODS: This was a multicentre, observational study. Data were collected prospectively between January 2002 and March 2019 and analysed retrospectively. Inclusion criteria for the final analysis were the treatment of elective or urgent ETAA performed in a single-stage or a planned two-stage approach. Early and late survival rates were the primary outcomes. RESULTS: Indications for repair were degenerative ETAA in 27 (64.3%) patients and dissection-related ETAA in 15 (35.7%). The mean aortic diameter was 68 ± 16 mm (interquartile range 60-75). Five (11.9%) patients had a single-stage repair; and 37 underwent a two-stage approach. Three (7.1%) patients died in-hospital. The median follow-up was 49 months (range 0-204). During the follow-up period, 4 (9.5%) patients underwent aortic reintervention after a median of 32 months; however, no aortic rupture of the treated segment occurred. Overall, the estimated survival rate was 85% ± 6% [95% confidence interval (CI) 70.8-93] at 12 and 36 months and 69.5% ± 9% (95% CI 49.7-84) at 60 months. CONCLUSIONS: Hybrid repair of ETAA had satisfactory early results in this cohort of patients. At the midterm follow-up, the aneurysm-related mortality rate was acceptable with the reconstruction proving to be durable and safe with few distal aortic events.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Humanos , Complicaciones Posoperatorias , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
14.
World J Surg ; 44(6): 2010-2019, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32047985

RESUMEN

BACKGROUND: We present a comparison of renal function outcomes during HTAR with the use of a new hybrid vascular graft (GHVG) or standard graft. METHODS: It is a multicenter, retrospective, observational study. Between January 2015 and March 2019, 36 patients were treated with HTAR. We compared HTAR performed with the use of the GHVG and with the use of standard bypass graft. Primary outcome measures were hospital mortality, acute kidney injury (AKI) at 30 days and GHVG patency. RESULTS: Mean GHVG ischemia time was significantly lower for both renal arteries (right: GHVG, 4 ± 2 vs. standard graft, 15 ± 7 min; 95% CI 2.23-6.69, P < 0.001; left: GHVG, 3 ± 2 vs. standard graft, 13 ± 7 min; 95% CI 2.44-5.03, P < 0.001). Hospital mortality was 17% (6/36); while mortality did not differ between the two groups, postoperative acute kidney injury rate was 30.5% (11/36 patients) and was more common in the standard graft group (7% vs. 29%; OR 3.2, P = 0.074). Estimated primary patency was 92% ± 2 (95% CI 79.5-97%) at 36 months and was not different between the two groups (GHVG 94% ± 6 vs. standard graft 91% ± 6; log-rank χ2 = 0.260, P = 0.610). CONCLUSIONS: In our experience of HTAR, ischemia time was significantly shorter and postoperative AKI occurrence was lower with GHVG if compared to standard graft bypass, with satisfactory midterm patency rate comparable to that of standard graft bypass.


Asunto(s)
Lesión Renal Aguda/etiología , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular/efectos adversos , Injerto Vascular/efectos adversos , Lesión Renal Aguda/fisiopatología , Anciano , Anciano de 80 o más Años , Implantación de Prótesis Vascular/efectos adversos , Femenino , Mortalidad Hospitalaria , Humanos , Estimación de Kaplan-Meier , Riñón/cirugía , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Isquemia Tibia
15.
J Thorac Cardiovasc Surg ; 159(6): 2189-2198.e1, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31301891

RESUMEN

OBJECTIVES: The aim of this study was to present our experience with the management of isolated left vertebral artery during hybrid aortic arch repairs with thoracic endovascular aortic repair completion. METHODS: This is a single-center, observational, cohort study. Between January 2007 and December 2018, 9 patients (4.5%) of 200 who underwent thoracic endovascular aortic repair were identified with isolated left vertebral artery. The isolated left vertebral artery was the dominant vertebral artery in 4 cases and entered the Circle of Willis to form the basilar artery in all cases. Isolated left vertebral artery transposition was performed in 2 patients during open ascending/arch repair before thoracic endovascular aortic repair completion. In 4 patients, isolated left vertebral artery transposition was performed concomitant with carotid-subclavian bypass during thoracic endovascular aortic repair completion ("zone 2" thoracic endovascular aortic repair). Primary outcomes were early (<30 days) and late survival, freedom from aortic-related mortality, and isolated left vertebral artery patency. RESULTS: Primary technical success was achieved in all cases. Isolated left vertebral artery-related complication occurred in 1 patient (Horner syndrome). Immediate thrombosis, vagus/recurrent laryngeal nerve palsy, lymphocele, and chylothorax were never observed. Postoperative cerebrovascular accident or spinal cord injury was not observed. Median follow-up was 15 months (range, 3-72). We did not observe aortic-related mortality during the follow-up. Aortic-related intervention was never required. Both isolated left vertebral artery and carotid-subclavian bypass are still patent in all patients with no sign of anastomotic pseudoaneurysm or stenosis. CONCLUSIONS: Although isolated left vertebral artery is not a frequent occurrence, it is not so rare. It may pose additional difficulties during hybrid aortic arch surgical repairs, but isolated left vertebral artery transposition was feasible, safe, and a durable reconstruction.


Asunto(s)
Aorta Torácica/cirugía , Enfermedades de la Aorta/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Arteria Vertebral/cirugía , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Síndrome de Horner/etiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Grado de Desobstrucción Vascular , Arteria Vertebral/anomalías , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/fisiopatología
17.
J Endovasc Ther ; 25(6): 740-749, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30284491

RESUMEN

PURPOSE: To analyze the results of isolated left subclavian artery (LSA) revascularization during thoracic endovascular aortic repair (TEVAR) using carotid-subclavian bypass (CSbp) or chimney grafts (CGs). METHODS: A retrospective multicenter, observational study identified 73 patients (mean age 68±13 years, range 22-87; 56 men) with acute or chronic thoracic aortic lesions who underwent TEVAR with isolated LSA revascularization using either CSbp (n=42) or CGs (n=31) from January 2010 and February 2017. Primary endpoints were TEVAR-related mortality, postoperative stroke, freedom from type Ia endoleak, and LSA patency. RESULTS: Primary technical success was achieved in all cases. Early TEVAR-related mortality was 4.2% (CSbp 2% vs CG 6%, p=0.571). Two (3%) patients had major ischemic strokes (one in each group). Mean follow-up was 24±21 months (range 1-72; median 15). Estimated freedom from TEVAR-related mortality was 93%±3% (95% CI 84.3% to 97.0%) at 12 and 36 months, with no significant difference between CSbp and CG (p=0.258). Aortic reintervention did not differ between the groups (CSbp 5% vs CG 6%, p=0.356); nor did freedom from type Ia endoleak (CSbp 98% vs CG 87%, p=0.134). Gutter-related endoleaks occurred in 4 (13%) CG patients, but none of the patients experienced sac enlargement or the need for reintervention and none died. Primary patency of the LSA was 100% for the entire group during the observation period. CONCLUSION: In our experience, LSA revascularization proved most satisfactory and equally effective with both the CSbp and CG techniques, without discernible differences at midterm follow-up.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/métodos , Arteria Subclavia/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Factores de Riesgo , Arteria Subclavia/diagnóstico por imagen , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
18.
Ann Vasc Surg ; 49: 107-114, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29481924

RESUMEN

BACKGROUND: We report the results of the operative treatment of synchronous type B acute aortic dissection (TBAAD) and infrarenal abdominal aortic aneurysm (AAA). METHODS: It is an observational, descriptive multicenter case series. Inclusion criterion was patients with diagnosis of TBAAD and AAA detected synchronously for the first time at clinical onset of dissection. Follow-up imaging protocol included triple-phase spiral/computed tomography angiography performed at 1, 6, and 12 months after thoracic endovascular aortic repair (TEVAR), and annually thereafter. Major end points were perioperative mortality and long-term survival, freedom from aortic events, and freedom from reintervention. RESULTS: We identified and treated 15 cases. All TBAADs were treated by TEVAR in the acute phase: infrarenal aortic repair was performed with stent graft (SG) in 10 (66.7%) patients, with open repair in 5 (33.3%). Overall, staged repair was used in 11 (73.3%) patients. Mean descending aortic endovascular length coverage was 21 cm ± 7 (range, 10-35; interquartile range [IQR], 150-265). Overall, early perioperative mortality occurred in 1 (6.7%) patient. Median radiologic follow-up was 48 months (range, 6-120; IQR, 36-67). During the follow-up, TEVAR-related mortality was not observed. Aortic remodeling after TEVAR was obtained in 12 (85.7%) patients; abdominal sac shrinkage after SG was obtained in 8 (80.0%) patients. Freedom from aortic event rate was 79% ± 10 (95% confidence interval [CI]: 53.1-92.6) at 1 year and 64% ± 13 (95% CI: 38.1-83.5) at 5 year. Freedom from reintervention rate at 1 and 5 year was 85% ± 10 (95% CI: 57.8-95.7). CONCLUSIONS: In our experience, the association of TBAAD and AAA was a rare finding. Because of the lack of available evidence to opt for a single intervention or a staged approach, selective approach with TEVAR and endovascular/open conventional treatment of the abdominal aorta yielded satisfactory results at midterm follow-up.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Disección Aórtica/fisiopatología , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/metabolismo , Aneurisma de la Aorta Abdominal/fisiopatología , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Angiografía por Tomografía Computarizada , Bases de Datos Factuales , Supervivencia sin Enfermedad , Femenino , Humanos , Italia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Tomografía Computarizada Espiral , Resultado del Tratamiento , Remodelación Vascular
20.
Eur J Cardiothorac Surg ; 52(4): 818-819, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-29156010

RESUMEN

Transcatheter valve procedures are wide-spreading techniques for the treatment of heart valves pathologies. In case of implantation failure, the transcatheter device often needs to be removed. This procedure, which can alter the biological structure integrity, can limit the option available for the subsequent traditional surgery. One of the most popular devices for transcatheter mitral valve repair is the MitraClip system. In this work, we describe 2 different techniques for the surgical removal of MitraClip. These techniques aim to preserve the valve leaflets integrity, to allow for subsequent mitral valve surgical repair.


Asunto(s)
Remoción de Dispositivos/métodos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Mitral/cirugía , Cateterismo Cardíaco/instrumentación , Falla de Equipo , Humanos , Insuficiencia de la Válvula Mitral/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...