Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Adv Sci (Weinh) ; : e2404564, 2024 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-39225621

RESUMEN

Accelerating a free electron to high-energy forms the basis for studying particle and nuclear physics. Here it is shown that the wave function of such an energetic electron can be further manipulated with the femtosecond intense lasers. During the scattering between a high-energy electron and a circularly polarized laser pulse, a regime is found where the enormous spin angular momenta of laser photons can be efficiently transferred to the electron orbital angular momentum (OAM). The wave function of the scattered electron is twisted from its initial plane-wave state to the quantum vortex state. Nonlinear quantum electrodynamics (QED) theory suggests that the GeV-level electrons acquire average intrinsic OAM beyond ⟨ l ⟩ ∼ 100 ℏ $\langle l \rangle \sim 100\hbar $ at laser intensities of 1020 W cm-2 with linear scaling. These electrons emit γ-photons with two-peak spectrum, which sets them apart from the ordinary electrons. The findings demonstrate a proficient method for generating relativistic leptons with the vortex wave functions based on existing laser technology, thereby fostering a novel source for particle and nuclear physics.

2.
Phys Rev E ; 105(2-2): 025309, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35291085

RESUMEN

Research on laser-plasma interaction in the quantum-electrodynamic (QED) regime has been greatly advanced by particle-in-cell and Monte Carlo simulations (PIC-MC). While these simulations are widely used, we find that a noticeable numerical error arises due to inappropriate implementation of the quantum process accounting for hard photon emission and pair production in the PIC-MC codes. The error stems from the low resolution of the QED table used to sample photon energy, which is generated in the logarithmic scale and cannot resolve high energy photons. We propose a sampling method via sigmoid function that handles both the low energy and high energy end of the photon emission spectrum. It guarantees the accuracy of PIC-MC algorithms for hard photon radiation and other related processes in the strong-field QED regime.

3.
Phys Rev E ; 100(4-1): 043202, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31770946

RESUMEN

We investigate the precession of electron spins during beam-driven plasma-wakefield acceleration based on density down-ramp injection by means of full three-dimensional (3D) particle-in-cell (PIC) simulations. A relativistic electron beam generated via, e.g., laser wakefield acceleration, serves as the driving source. It traverses the prepolarized gas target and accelerates polarized electrons via the excited wakefield. We derive the criteria for the driving beam parameters and the limitation on the injected beam flux to preserve a high degree of polarization for the accelerated electrons, which are confirmed by our 3D PIC simulations and single-particle modeling. The electron-beam driver is free of the prepulse issue associated with a laser driver, thus eliminating possible depolarization of the prepolarized gas due to ionization by the prepulse. These results provide guidance for future experiments towards generating a source of polarized electrons based on wakefield acceleration.

4.
Environ Pollut ; 220(Pt B): 963-970, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27823866

RESUMEN

Atmospheric ammonia (NH3), a common alkaline gas found in air, plays a significant role in atmospheric chemistry, such as in the formation of secondary particles. However, large uncertainties remain in the estimation of ammonia emissions from nonagricultural sources, such as wastewater treatment plants (WWTPs). In this study, the ammonia emission factors from a large WWTP utilizing three typical biological treatment techniques to process wastewater in South China were calculated using the US EPA's WATER9 model with three years of raw sewage measurements and information about the facility. The individual emission factors calculated were 0.15 ± 0.03, 0.24 ± 0.05, 0.29 ± 0.06, and 0.25 ± 0.05 g NH3 m-3 sewage for the adsorption-biodegradation activated sludge treatment process, the UNITANK process (an upgrade of the sequencing batch reactor activated sludge treatment process), and two slightly different anaerobic-anoxic-oxic treatment processes, respectively. The overall emission factor of the WWTP was 0.24 ± 0.06 g NH3m-3 sewage. The pH of the wastewater influent is likely an important factor affecting ammonia emissions, because higher emission factors existed at higher pH values. Based on the ammonia emission factor generated in this study, sewage treatment accounted for approximately 4% of the ammonia emissions for the urban area of South China's Pearl River Delta (PRD) in 2006, which is much less than the value of 34% estimated in previous studies. To reduce the large uncertainty in the estimation of ammonia emissions in China, more field measurements are required.


Asunto(s)
Amoníaco/análisis , Monitoreo del Ambiente , Aguas Residuales/química , China , Aguas del Alcantarillado/química , Eliminación de Residuos Líquidos/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA