Chronic implantation of intracortical microelectrode arrays (MEAs) capable of recording from individual neurons can be used for the development of brain-machine interfaces. However, these devices show reduced recording capabilities under chronic conditions due, at least in part, to the brain's foreign body response (FBR). This creates a need for MEAs that can minimize the FBR to possibly enable long-term recording. A potential approach to reduce the FBR is the use of MEAs with reduced cross-sectional geometries. Here, we fabricated 4-shank amorphous silicon carbide (a-SiC) MEAs and implanted them into the motor cortex of seven female Sprague-Dawley rats. Each a-SiC MEA shank was 8 µm thick by 20 µm wide and had sixteen sputtered iridium oxide film (SIROF) electrodes (4 per shank). A-SiC was chosen as the fabrication base for its high chemical stability, good electrical insulation properties, and amenability to thin film fabrication. Electrochemical analysis and neural recordings were performed weekly for 4 months. MEAs were characterized pre-implantation in buffered saline and in vivo using electrochemical impedance spectroscopy and cyclic voltammetry at 50 mV/s and 50,000 mV/s. Neural recordings were analyzed for single unit activity. At the end of the study, animals were sacrificed for immunohistochemical analysis. We observed statistically significant, but small, increases in 1 and 30 kHz impedance values and 50,000 mV/s charge storage capacity over the 16-week implantation period. Slow sweep 50 mV/s CV and 1 Hz impedance did not significantly change over time. Impedance values increased from 11.6 MΩ to 13.5 MΩ at 1 Hz, 1.2 MΩ-2.9 MΩ at 1 kHz, and 0.11 MΩ-0.13 MΩ at 30 kHz over 16 weeks. The median charge storage capacity of the implanted electrodes at 50 mV/s was 58.1 mC/cm2 on week 1 and 55.9 mC/cm2 on week 16, and at 50,000 mV/s, 4.27 mC/cm2 on week 1 and 5.93 mC/cm2 on week 16. Devices were able to record neural activity from 92% of all active channels at the beginning of the study, At the study endpoint, a-SiC devices were still recording single-unit activity on 51% of electrochemically active electrode channels. In addition, we observed that the signal-to-noise ratio experienced a small decline of -0.19 per week. We also classified observed units as fast and slow repolarizing based on the trough-to-peak time. Although the overall presence of single units declined, fast and slow repolarizing units declined at a similar rate. At recording electrode depth, immunohistochemistry showed minimal tissue response to the a-SiC devices, as indicated by statistically insignificant differences in activated glial cell response between implanted brains slices and contralateral sham slices at 150 µm away from the implant location, as evidenced by GFAP staining. NeuN staining revealed the presence of neuronal cell bodies close to the implantation site, again statistically not different from a contralateral sham slice. These results warrant further investigation of a-SiC MEAs for future long-term implantation neural recording studies.


Asunto(s)
Compuestos Inorgánicos de Carbono , Electrodos Implantados , Microelectrodos , Corteza Motora , Ratas Sprague-Dawley , Compuestos de Silicona , Animales , Compuestos de Silicona/química , Femenino , Corteza Motora/fisiología , Corteza Motora/citología , Compuestos Inorgánicos de Carbono/química , Ratas , Neuronas/fisiología
4.
Micromachines (Basel) ; 13(10)2022 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-36296045

RESUMEN

Recent advances in cell and tissue engineering have enabled long-term three-dimensional (3D) in vitro cultures of human-derived neuronal tissues. Analogous two-dimensional (2D) tissue cultures have been used for decades in combination with substrate integrated microelectrode arrays (MEA) for pharmacological and toxicological assessments. While the phenotypic and cytoarchitectural arguments for 3D culture are clear, 3D MEA technologies are presently inadequate. This is mostly due to the technical challenge of creating vertical electrical conduction paths (or 'traces') using standardized biocompatible materials and fabrication techniques. Here, we have circumvented that challenge by designing and fabricating a novel helical 3D MEA comprised of polyimide, amorphous silicon carbide (a-SiC), gold/titanium, and sputtered iridium oxide films (SIROF). Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) testing confirmed fully-fabricated MEAs should be capable of recording extracellular action potentials (EAPs) with high signal-to-noise ratios (SNR). We then seeded induced pluripotent stems cell (iPSC) sensory neurons (SNs) in a 3D collagen-based hydrogel integrated with the helical MEAs and recorded EAPs for up to 28 days in vitro from across the MEA volume. Importantly, this highly adaptable design does not intrinsically limit cell/tissue type, channel count, height, or total volume.

5.
Sci Rep ; 12(1): 15503, 2022 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-36109613

RESUMEN

Gyriform mammals display neurophysiological and neural network activity that other species exhibit only in rudimentary or dissimilar form. However, neural recordings from large mammals such as the pig can be anatomically hindered and pharmacologically suppressed by anesthetics. This curtails comparative inferences. To mitigate these limitations, we set out to modify electrocorticography, intracerebral depth and intracortical recording methods to study the anesthetized pig. In the process, we found that common forms of infused anesthesia such as pentobarbital or midazolam can be neurophysiologic suppressants acting in dose-independent fashion relative to anesthetic dose or brain concentration. Further, we corroborated that standard laboratory conditions may impose electrical interference with specific neural signals. We thus aimed to safeguard neural network integrity and recording fidelity by developing surgical, anesthesia and noise reduction methods and by working inside a newly designed Faraday cage, and evaluated this from the point of view of neurophysiological power spectral density and coherence analyses. We also utilized novel silicon carbide electrodes to minimize mechanical disruption of single-neuron activity. These methods allowed for the preservation of native neurophysiological activity for several hours. Pig electrocorticography recordings were essentially indistinguishable from awake human recordings except for the small segment of electrical activity associated with vision in conscious persons. In addition, single-neuron and paired-pulse stimulation recordings were feasible simultaneously with electrocorticography and depth electrode recordings. The spontaneous and stimulus-elicited neuronal activities thus surveyed can be recorded with a degree of precision similar to that achievable in rodent or any other animal studies and prove as informative as unperturbed human electrocorticography.


Asunto(s)
Anestésicos , Vigilia , Animales , Encéfalo/fisiología , Humanos , Mamíferos , Midazolam , Neuronas/fisiología , Pentobarbital , Porcinos
6.
J Neural Eng ; 19(2)2022 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-35263724

RESUMEN

Objective. Trauma induced by the insertion of microelectrodes into cortical neural tissue is a significant problem. Further, micromotion and mechanical mismatch between microelectrode probes and neural tissue is implicated in an adverse foreign body response (FBR). Hence, intracortical ultra-microelectrode probes have been proposed as alternatives that minimize this FBR. However, significant challenges in implanting these flexible probes remain. We investigated the insertion mechanics of amorphous silicon carbide (a-SiC) probes with a view to defining probe geometries that can be inserted into cortex without buckling.Approach. We determined the critical buckling force of a-SiC probes as a function of probe geometry and then characterized the buckling behavior of these probes by measuring force-displacement responses during insertion into agarose gel and rat cortex.Main results.Insertion forces for a range of probe geometries were determined and compared with critical buckling forces to establish geometries that should avoid buckling during implantation into brain. The studies show that slower insertion speeds reduce the maximum insertion force for single-shank probes but increase cortical dimpling during insertion of multi-shank probes.Significance.Our results provide a guide for selecting probe geometries and insertion speeds that allow unaided implantation of probes into rat cortex. The design approach is applicable to other animal models where insertion of intracortical probes to a depth of 2 mm is required.


Asunto(s)
Encéfalo , Fenómenos Mecánicos , Animales , Electrodos Implantados , Microelectrodos , Ratas
7.
J Biomed Mater Res B Appl Biomater ; 108(3): 880-891, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31353822

RESUMEN

The deposition and properties of sputtered iridium oxide films (SIROFs) using water vapor as a reactive gas constituent are investigated for their potential as high-charge-capacity neural stimulation electrodes. Systematic investigation through a series of optical and electrochemical measurements reveals that the incorporation of water vapor as a reactive gas constituent, along with oxygen, alters the reduction-oxidation (redox) state of the plasma as well as its morphology and the electrochemical characteristics, including the cathodal charge-storage capacity (CSCc ) and charge-injection capacity (CIC), of the SIROF. An apparent optimal O2 :H2 O gas ratio of 1:3 produced SIROF with a CSCc of 182.0 mC cm-2 µm-1 (median, Q1 = 172.5, Q3 = 193.4, n = 15) and a CIC of 3.57 mC cm-2 (median, Q1 = 2.97, Q3 = 4.58, n = 12) for 300-nm-thick films. These values are higher than those obtained with SIROFs deposited using no water vapor by a factor of 2.3 and 1.7 for the CSCc and CIC, respectively. Additionally, the SIROF showed minimal changes in electrochemical characteristics over 109 pulses of constant current stimulation and showed no indication of cytotoxicity toward primary cortical neurons in a cell viability assay. These results warrant investigation of the chronic recording and stimulation capabilities of the SIROF for implantable microelectrode arrays.


Asunto(s)
Estimulación Eléctrica , Electrodos , Iridio/química , Neuronas/efectos de los fármacos , Neuronas/metabolismo , Animales , Supervivencia Celular , Células Cultivadas , Electroquímica , Electrodos Implantados , Electrólitos , Gases , Espectrometría de Masas , Ensayo de Materiales , Ratones , Microelectrodos , Oxidación-Reducción , Oxígeno/química , Agua