Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
1.
Ann Cardiol Angeiol (Paris) ; 72(6): 101681, 2023 Dec.
Artículo en Francés | MEDLINE | ID: mdl-37948924

RESUMEN

The Register of Cardiac Accidents of Endurance Races in Paris (RACE Paris), an observational prospective cohort study collected sudden deaths and life-threatening accidents from five major Parisian endurance races over 10 years.


Asunto(s)
Muerte Súbita Cardíaca , Humanos , Paris/epidemiología , Estudios Prospectivos , Sistema de Registros
2.
EuroIntervention ; 19(5): e442-e449, 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37128805

RESUMEN

BACKGROUND: Data regarding the safety and long-term effectiveness of percutaneous closure of paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) are scarce. AIMS: This study aims to present a large multicentre international experience of percutaneous post-TAVI PVL closure. METHODS: All patients who underwent percutaneous post-TAVI PVL closure in 14 hospitals across Europe and North America between January 2018 and October 2022 were included. RESULTS: Overall, 45 patients (64% male) were enrolled. The median age was 80 years (75-84). Among them, 67% and 33% had self-expanding and balloon-expandable valve implantations, respectively. Baseline post-TAVI PVL was severe in 67% of cases and moderate in the rest. The time from index TAVI to PVL closure procedure was 16.1 (8.7-34.8) months. Most patients were in NYHA Class III and IV (73%) before the procedure, and 40% had referred hospitalisations for heart failure between TAVI and the PVL closure procedure. Successful PVL closure was achieved in 94%, reducing regurgitation to ≤mild in 91% and moderate in the rest. The Amplatzer Valvular Plug III was the most frequently used device (27 cases), followed by the Amplatzer Valvular Plug 4. The incidence of severe adverse events was 11%. None of the patients died during the index hospitalisation. During long-term follow-up (21.7±16.2 months), the all-cause mortality rate was 14%, and patients presented improvement in functional status and a significant reduction in the rate of hospitalisation for heart failure (from 40% to 6%). CONCLUSIONS: Percutaneous PVL closure is a feasible and safe option for treating post-TAVI leaks. Successful PVL reduction to mild or less could be associated with acute and long-lasting improvements in clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Sistema de Registros , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía
3.
Circ Cardiovasc Interv ; 15(10): e012193, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36256693

RESUMEN

BACKGROUND: Transcatheter closure of a symptomatic prosthetic paravalvular leak (PVL) is feasible, but there is presently no conclusive evidence to show consistent efficacy. We aimed to identify predictors of clinical success after transcatheter PVL closure. METHODS: Consecutive patients referred to 24 European centers for transcatheter PVL closure in 2017 to 2019 were included in a prospective registry (Fermeture de Fuite ParaProthétique, FFPP). Clinical success was absence of any of the following within 1 month: re-admission for heart failure, blood transfusion, open-heart valvular surgery, and death. RESULTS: We included 216 symptomatic patients, who underwent 238 percutaneous PVL closure procedures on the mitral (64.3%), aortic (34.0%), or tricuspid (1.7%) valve. Symptoms were heart failure, hemolytic anemia, or both in 48.9%, 7.8%, and 43.3% of patients, respectively. One, 2, and 3 leaks were treated during the same procedure in 69.6%, 26.6%, and 3.8% of patients, respectively. The PVL was pinpoint or involved 1/8 or 1/4 of the valve circumference in 18.6%, 52.4%, and 28.1% of cases, respectively. The most frequently used devices were the Vascular Plug 3, Ventricular Septal Defect Occluder, Vascular Plug 2, and Paravalvular Leak Device (45.0%, 16.6%, 14.2%, and 13.6% of cases, respectively). Successful device(s) implantation with leak reduction to ≤grade 2 was obtained in 85.0% of mitral and 91.4% of aortic procedures, respectively (P=0.164); with major periprocedural adverse event rates of 3.3% and 1.2%, respectively (P=0.371); and clinical success rates of 70.3% and 88.0%, respectively (P=0.004). By multivariate analysis, technical failure, mechanical valve, and hemolytic anemia were independently associated with absence of clinical success (odds ratios [95% CIs], 7.7 [2.0-25.0]; P=0.002; 3.6 [1.1-11.1]; P=0.036; and 3.7 [1.2-11.9]; P=0.025; respectively). CONCLUSIONS: Transcatheter PVL closure is efficient and safe in symptomatic patients but is associated with a lower clinical success rate in patients with hemolysis and/or a mechanical valve. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifiers: NCT05089136.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Insuficiencia Cardíaca/etiología , Cateterismo Cardíaco , Falla de Prótesis
4.
Phys Rev E ; 106(2-2): 025001, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-36110010

RESUMEN

In a heterogeneous medium, the wave field can be decomposed as an infinite series known as the Born expansion. Each term of the Born expansion corresponds to a scattering order, it is thus theoretically possible to discriminate single and multiple scattering contribution to the field. Experimentally, what is actually measured is the total field in which all scattering orders interfere. Conventional imaging methods usually rely on the assumption that the multiple scattering contribution can be disregarded. In a back-scattering configuration, this assumption is valid for small depths, and begins to fail for depths larger than the scattering mean-free path ℓ_{s}. It is therefore a key issue to estimate the relative amount of single and multiple scattering in experimental data. To this end, a single-scattering estimator ρ[over ̂] computed from the reflection matrix has been introduced in order to assess the weight of single scattering in the backscattered wave field. In this paper, the meaning of this estimator is investigated and a particular attention is given to recurrent scattering. In a diffraction-limited experiment, a multiple scattering sequence is said to be recurrent if the first and last scattering events occur in the same resolution cell. Recurrent scattering is shown to be responsible for correlations between single scattering and higher scattering orders of the Born expansion, inducing a bias to the estimator ρ[over ̂] that should rather be termed confocal scattering ratio. Interestingly, a more robust estimator is built by projecting the reflection matrix in a focused basis. The argument is sustained by numerical simulations as well as ultrasonic data obtained around 1.5 MHz in a model medium made of nylon rods immersed in water. From a more general perspective, this work raises fundamental questions about the impact of recurrent scattering on wave imaging.

5.
J Clin Med ; 11(16)2022 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-36012997

RESUMEN

BACKGROUND: Percutaneous closure of paravalvular leak (PVL) has emerged as an alternative to surgical management in selected cases. Achieving complete PVL occlusion, while respecting prosthesis function remains challenging. A multimodal imaging analysis of PVL morphology before and during the procedure is mandatory to select an appropriate device. We aim to explore the additional value of 3D printing in predicting device related adverse events including mechanical valve leaflet blockade, risk of device embolization and residual shunting. METHODS: From the FFPP registries (NCT05089136 and NCT05117359), we included 11 transcatheter PVL closure procedures from three centers for which 3D printed models were produced. Cardiac CT was used for segmentation for 3D printed models (3D-heartmodeling, Caissargues, France). Technology used a laser to fuse very fine powders (TPU Thermoplastic polyurethane) into a final part-laser sintering technology (SLS) with an adapted elasticity. A simulation on 3D printed model was performed using a set of occluders. RESULTS: PVLs were located around aortic prostheses in six cases, mitral prostheses in four cases and tricuspid ring in one case. The device chosen during the simulation on the 3D printed model matched the one implanted in eight cases. In the three other cases, a similar device type was chosen during the procedures but with a different size. A risk of prosthesis leaflet blockade was identified on 3D printed models in four cases. During the procedure, the occluder was removed before release in one case. In another case the device was successfully repositioned and released. In two patients, leaflet impingement was observed post-operatively and surgical device removal had to be performed. CONCLUSION: In a case-series of complex transcatheter PVL closure procedures, hands-on simulation testing on 3D printed models proved its usefulness to plan and facilitate these challenging procedures.

6.
J Clin Med ; 12(1)2022 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-36614920

RESUMEN

Prosthetic paravalvular leaks (PVLs) are associated with congestive heart failure and hemolysis. Surgical PVL closure carries high risks. Transcatheter implantation of occluding devices in PVL is a lower risk but challenging procedure. Of the available devices, only two have been specifically approved in Europe for transcatheter PVL closure (tPVLc): the Occlutech® Paravalvular Leak Device (PLD) and Amplatzer™ ParaValvular Plug 3 (AVP 3). Here, we review the various tools and devices used for tPVLc, based on three observational registries including 748 tPVLc procedures performed in 2005-2021 at 33 centres in 11 countries. In this case, 12 registry investigators with over 20 tPVLc procedures each described their practical tips and tricks regarding imaging, approaches, delivery systems, and devices. They considered three-dimensional echocardiography to be the cornerstone of PVL assessment and procedure guidance. Anterograde trans-septal mitral valve and retrograde aortic approaches were used in most centres, although some investigators preferred the transapical approach. Hydrophilic-coated low-profile sheaths were used most often for device deployment. The AVP 3 and PLD devices were chosen for 89.0% of procedures. Further advances in design and materials are awaited. These complex procedures require considerable expertise, and experience accumulated over a decade has no doubt contributed to improve practices.

7.
Sci Rep ; 11(1): 23901, 2021 Dec 13.
Artículo en Inglés | MEDLINE | ID: mdl-34903769

RESUMEN

We report on experimental and numerical implementations of devices based on the negative refraction of elastic guided waves, the so-called Lamb waves. Consisting in plates of varying thickness, these devices rely on the concept of complementary media, where a particular layout of negative index media can cloak an object with its anti-object or trap waves around a negative corner. The diffraction cancellation operated by negative refraction is investigated by means of laser ultrasound experiments. However, unlike original theoretical predictions, these intriguing wave phenomena remain, nevertheless, limited to the propagating component of the wave-field. To go beyond the diffraction limit, negative refraction is combined with the concept of metalens, a device converting the evanescent components of an object into propagating waves. The transport of an evanescent wave-field is then possible from an object plane to a far-field imaging plane. Twenty years after Pendry's initial proposal, this work thus paves the way towards an elastic superlens.

8.
Eur J Prev Cardiol ; 28(6): 679-686, 2021 05 22.
Artículo en Inglés | MEDLINE | ID: mdl-34021577

RESUMEN

AIMS: Limited data exist regarding the incidence and aetiology of life-threatening events such as major cardiac events or exertional heat stroke during long-distance races. We aimed to provide an updated incidence, etiology and prognosis of life-threatening events during long-distance races. METHODS: The prospective RACE PARIS registry recorded all life-threatening events/fatal events occurring during 46 marathons, half-marathons and other long-distance races in the Paris area between 2006 and 2016, comprising 1,073,722 runners. Event characteristics were determined by review of medical records and interviews with survivors. RESULTS: The incidence of life-threatening events, exertional heat stroke and major cardiac events was 3.35 per 100,000, 1.02 per 100,000 and 2.33 per 100,000, respectively, including 18 sudden cardiac arrests (1.67 per 100,000). The main aetiology of sudden cardiac arrest was myocardial ischaemia (11/18), due to acute coronary thrombosis (6/11), stable atherosclerotic coronary artery disease (2/11), coronary dissection (1/11), anomalous connection (1/11) or myocardial bridging (1/11). A third of participants with ischaemia-related major cardiac events presented with pre-race clinical symptoms. Major cardiac events were more frequent in the case of a high pollution index (6.78 per 100,000 vs. 2.07 per 100,000, odds ratio 3.27, 95% confidence interval 1.12-9.54). Case fatality was low (0.19 per 100,000). Similarly, we report in a meta-analysis of eight long-distance race registries comprising 16,223,866 runners a low incidence of long-distance race-related sudden cardiac arrest (0.82 per 100,000) and fatality (0.39 per 100,000). Death following sudden cardiac arrest was strongly associated with initial asystole or pulseless rhythm. CONCLUSION: Long-distance race-related life-threatening events remain rare although serious events. Better information for runners on the risk of pre-race clinical symptoms, outside air pollution and temperature may reduce their incidence.


Asunto(s)
Paro Cardíaco , Carrera , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Humanos , Estudios Prospectivos , Sistema de Registros
10.
Eur Respir J ; 53(5)2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31023842

RESUMEN

AIMS: To evaluate safety and efficacy of balloon pulmonary angioplasty (BPA) in a large cohort of patients with chronic thromboembolic pulmonary hypertension (CTEPH). METHODS: From 2014 to 2017, 184 inoperable CTEPH patients underwent 1006 BPA sessions. Safety and efficacy during the first 21 months (initial period) were compared with those of the last 21 months (recent period). A total of 154 patients had a full evaluation after a median duration of 6.1 months. RESULTS: Overall, there was a significant improvement in New York Heart Association functional class, 6-min walk distance (mean change +45 m), and a significant decrease in mean pulmonary artery pressure (PAP) and in pulmonary vascular resistance (PVR) by 26% and 43%, respectively. The percentage decreases of mean PAP and PVR were 22% and 37% in the initial period versus 30% and 49% in the recent period, respectively (p<0.05). The main complications included lung injury, which occurred in 9.1% of 1006 sessions (13.3% in the initial period versus 5.9% in the recent period; p<0.001). Per-patient multivariate analysis revealed that baseline mean PAP and the period during which BPA procedure was performed (recent versus initial period) were the strongest factors related to the occurrence of lung injury. 3-year survival was 95.1%. CONCLUSION: This study confirms that a refined BPA strategy improves short-term symptoms, exercise capacity and haemodynamics in inoperable CTEPH patients with an acceptable risk-benefit ratio. Safety and efficacy improve over time, underscoring the unavoidable learning curve for this procedure.


Asunto(s)
Angioplastia de Balón , Hipertensión Pulmonar/terapia , Arteria Pulmonar/fisiopatología , Embolia Pulmonar/terapia , Anciano , Enfermedad Crónica , Femenino , Francia , Hemodinámica , Humanos , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/mortalidad , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Embolia Pulmonar/complicaciones , Medición de Riesgo , Resultado del Tratamiento , Resistencia Vascular
11.
Sci Rep ; 9(1): 2135, 2019 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-30765745

RESUMEN

The propagation of waves in complex media can be harnessed either by taming the incident wave-field impinging on the medium or by forcing waves along desired paths through its careful design. These two alternative strategies have given rise to fascinating concepts such as time reversal or negative refraction. Here, we show how these two processes are intimately linked through the negative reflection phenomenon. A negative reflecting mirror converts a wave of positive phase velocity into its negative counterpart and vice versa. In this article, we experimentally demonstrate this phenomenon with elastic waves in a 2D billiard and in a disordered plate by means of laser interferometry. Despite the complexity of such configurations, the negatively reflected wave field focuses back towards the initial source location, thereby mimicking a phase conjugation operation while being a fully passive process. The super-focusing capability of negative reflection is also highlighted in a monochromatic regime. The negative reflection phenomenon is not restricted to guided elastic waves since it can occur in zero-gap systems such as photonic crystals, chiral metamaterials or graphene. Negative reflection can thus become a tool of choice for the control of waves in all fields of wave physics.

12.
Arch Cardiovasc Dis ; 111(6-7): 421-431, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29937207

RESUMEN

BACKGROUND: Percutaneous paravalvular leak (PVL) closure has emerged as a palliative alternative to surgical management in selected high-risk patients. Percutaneous procedures are challenging, especially for mitral PVL. Accurate imaging of the morphologies of the defects is mandatory, together with precise guidance in the catheterization laboratory to enhance success rates. AIMS: To describe imaging modalities used in clinical practice to guide percutaneous PVL closure and assess the potential of new imaging tools. METHODS: Data from the 'Fermeture de Fuite paraprothétique' (FFPP) register were used. The FFPP register is an international multi-institutional collaborative register started in 2017 with a retrospective and a prospective part. A descriptive analysis of multimodality imaging used to guide PVL closure in clinical practice was performed. RESULTS: Data from 173 procedures performed in 19 centres from three countries (France, Belgium and Poland) were collected, which included eight cases of PVL following transcatheter valve replacement. Transoesophageal echocardiography was used in 167 cases (96.5%) and 3D echocardiography in 87.4% of cases. In one case, 3D-echocardiography was fused with fluoroscopy images in real time using echonavigator software. Details about multimodality imaging were available from a sample of 31 patients. Cardiac computed tomography (CT) was performed before 10 of the procedures. In one case, fusion between preprocedural cardiac CT angiography data and fluoroscopy data was used. In two cases, a 3D model of the valve with PVL was printed. CONCLUSION: Echocardiography, particularly the 3D mode, is the cornerstone of PVL imaging. Other imaging modalities, such as cardiac CT and cardiac magnetic resonance imaging, may be of complementary interest. New techniques such as imaging fusion and printing may further facilitate the percutaneous approach of PVLs.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Válvula Aórtica/cirugía , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/terapia , Válvula Mitral/cirugía , Imagen Multimodal/métodos , Radiografía Intervencional/métodos , Ultrasonografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Angiografía por Tomografía Computarizada , Ecocardiografía Doppler en Color , Ecocardiografía Tridimensional , Ecocardiografía Transesofágica , Europa (Continente) , Femenino , Fluoroscopía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/fisiopatología , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/fisiopatología , Valor Predictivo de las Pruebas , Impresión Tridimensional , Estudios Prospectivos , Estudios Retrospectivos , Resultado del Tratamiento
13.
J Acoust Soc Am ; 140(1): 591, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-27475181

RESUMEN

The paper studies the interaction of Lamb waves with the free edge of a plate. The reflection coefficients of a Lamb mode at a plate free edge are calculated using a semi-analytical method, as a function of frequency and angle of incidence. The conversion between forward and backward Lamb modes is thoroughly investigated. It is shown that at the zero-group velocity (ZGV) frequency, the forward S1 Lamb mode fully converts into the backward S2b Lamb mode at normal incidence. Besides, this conversion is very efficient over most of the angular spectrum and remains dominant at frequencies just above the ZGV-point. This effect is observed experimentally on a Duralumin plate. First, the S1 Lamb mode is selectively generated using a transducer array, second the S2b mode is excited using a single circular transducer. The normal displacement field is probed with an interferometer. The free edge is shown to retro-focus the incident wave at different depths depending on the wave number mismatch between the forward and backward propagating modes. In the vicinity of the ZGV-point, wave numbers coincide and the wave is retro-reflected on the source. In this frequency range, the free edge acts as a perfect phase conjugating mirror.

14.
Arch Cardiovasc Dis ; 109(6-7): 376-83, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27020513

RESUMEN

BACKGROUND: Whereas the coronary artery disease death rate has declined in high-income countries, the incidence of acute coronary syndromes (ACS) is increasing in sub-Saharan Africa, where their management remains a challenge. AIM: To propose a consensus statement to optimize management of ACS in sub-Saharan Africa on the basis of realistic considerations. METHODS: The AFRICARDIO-2 conference (Yamoussoukro, May 2015) reviewed the ongoing features of ACS in 10 sub-Saharan countries (Benin, Burkina-Faso, Congo-Brazzaville, Guinea, Ivory Coast, Mali, Mauritania, Niger, Senegal, Togo), and analysed whether improvements in strategies and policies may be expected using readily available healthcare facilities. RESULTS: The outcome of patients with ACS is affected by clearly identified factors, including: delay to reaching first medical contact, achieving effective hospital transportation, increased time from symptom onset to reperfusion therapy, limited primary emergency facilities (especially in rural areas) and emergency medical service (EMS) prehospital management, and hence limited numbers of patients eligible for myocardial reperfusion (thrombolytic therapy and/or percutaneous coronary intervention [PCI]). With only five catheterization laboratories in the 10 participating countries, PCI rates are very low. However, in recent years, catheterization laboratories have been built in referral cardiology departments in large African towns (Abidjan and Dakar). Improvements in patient care and outcomes should target limited but selected objectives: increasing awareness and recognition of ACS symptoms; education of rural-based healthcare professionals; and developing and managing a network between first-line healthcare facilities in rural areas or small cities, emergency rooms in larger towns, the EMS, hospital-based cardiology departments and catheterization laboratories. CONCLUSION: Faced with the increasing prevalence of ACS in sub-Saharan Africa, healthcare policies should be developed to overcome the multiple shortcomings blunting optimal management. European and/or North American management guidelines should be adapted to African specificities. Our consensus statement aims to optimize patient management on the basis of realistic considerations, given the healthcare facilities, organizations and few cardiology teams that are available.


Asunto(s)
Síndrome Coronario Agudo/terapia , Cateterismo Cardíaco , Prestación Integrada de Atención de Salud/organización & administración , Países en Desarrollo , Accesibilidad a los Servicios de Salud/organización & administración , Intervención Coronaria Percutánea , Terapia Trombolítica , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/mortalidad , África del Sur del Sahara/epidemiología , Cateterismo Cardíaco/normas , Consenso , Prestación Integrada de Atención de Salud/normas , Accesibilidad a los Servicios de Salud/normas , Necesidades y Demandas de Servicios de Salud/organización & administración , Humanos , Incidencia , Evaluación de Necesidades/organización & administración , Grupo de Atención al Paciente/organización & administración , Intervención Coronaria Percutánea/normas , Prevalencia , Terapia Trombolítica/normas , Tiempo de Tratamiento/organización & administración , Resultado del Tratamiento
16.
Eur Heart J ; 37(32): 2531-41, 2016 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-26715168

RESUMEN

AIM: Long distance running races are associated with a low risk of life-threatening events much often attributed to hypertrophic cardiomyopathy. However, retrospective analyses of aetiology lack consistency. METHODS AND RESULTS: Incidence and aetiology of life-threatening/fatal events were assessed in long distance races in the prospective Registre des Accidents Cardiaques lors des courses d'Endurance (RACE Paris Registry) from October 2006 to September 2012. Characteristics of life-threatening/fatal events were analysed by interviewing survivors and reviewing medical records including post-mortem data of each case. Seventeen life-threatening events were identified of 511 880 runners of which two were fatal. The vast majority were cardiovascular events (13/17) occurring in experienced male runners [mean (±SD) age 43 ± 10 years], with infrequent cardiovascular risk factors, atypical warning symptoms prior to the race or negative treadmill test when performed. Acute myocardial ischaemia was the predominant aetiology (8 of 13) and led to immediate myocardial revascularization. All cases with initial shockable rhythm survived. There was no difference in event rate according to marathons vs. half-marathons and events were clustered at the end of the race. A meta-analysis of all available studies including the RACE Paris registry (n = 6) demonstrated a low prevalence of life-threatening events (0.75/100 000) and that presentation with non-shockable rhythm [OR = 29.9; 95% CI (4.0-222.5), P = 0.001] or non-ischaemic aetiology [OR = 6.4; 95% CI (1.4-28.8), P = 0.015] were associated with case-fatality. CONCLUSION: Life-threatening/fatal events during long distance races are rare, most often unpredictable and mainly due to acute myocardial ischaemia. Presentation with non-shockable rhythm and non-ischaemic aetiology are the major determinant of case fatality.


Asunto(s)
Carrera , Adulto , Muerte Súbita Cardíaca , Humanos , Masculino , Paris , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo
17.
Phys Rev Lett ; 113(17): 173901, 2014 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-25379917

RESUMEN

Thirty years ago, theorists showed that a properly designed combination of incident waves could be fully transmitted through (or reflected by) a disordered medium, based on the existence of propagation channels which are essentially either closed or open (bimodal law). In this Letter, we study elastic waves in a disordered waveguide and present direct experimental evidence of the bimodal law. Full transmission and reflection are achieved. The wave field is monitored by laser interferometry and highlights the interference effects that take place within the scattering medium.

18.
Arch Cardiovasc Dis ; 105(2): 60-7, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22424323

RESUMEN

BACKGROUND: Coronary stents have evolved over time, from bare-metal stents to drug-eluting stents, and now to bioactive stents. AIMS: We sought to explore the immediate outcome of the titanium-nitride-oxide-coated bioactive stent, Titan2(®), in real-world practice, and the incidence of major cardiac events at follow-up. METHODS: Consecutive patients admitted for percutaneous intervention for at least one significant (≥50%) lesion in a native coronary artery were treated with Titan2(®) stent implantation. The primary endpoint was total major adverse cardiac events at 12-month follow-up. Secondary endpoints included target lesion revascularization at 12-month follow-up and the duration of dual antiplatelet therapy. RESULTS: Among 356 patients (mean age 67.4 ± 12.1 years), 77.2% were male and 39.3% were treated for myocardial infarction (MI). A total of 546 Titan2(®) stents were implanted in 420 lesions. Angiographic and clinical procedural success was achieved in all cases. No cases of in-hospital major adverse cardiac events or acute stent thrombosis were reported. Of 335 patients (94.1%) with 12-month clinical follow-up, four (1.2%) died, MI occurred in five (1.5%), target lesion revascularization was performed in 17 (5.1%) and major adverse cardiac events occurred in 24 (7.2%). One patient (0.3%) suffered late stent thrombosis during follow-up, but no cases of acute or subacute stent thrombosis occurred. Dual antiplatelet therapy continued beyond 6 months in 64.5% of patients. CONCLUSIONS: In real-world practice, Titan2(®) stent implantation achieves an excellent immediate outcome, with a low incidence of major adverse cardiac events at 12-month follow-up.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Materiales Biocompatibles Revestidos , Estenosis Coronaria/terapia , Infarto del Miocardio/terapia , Stents , Titanio , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Angiografía Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Quimioterapia Combinada , Femenino , Francia , Agencias Gubernamentales , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Índice de Severidad de la Enfermedad , Trombosis/etiología , Factores de Tiempo , Resultado del Tratamiento
19.
Am J Cardiol ; 101(7): 1035-8, 2008 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-18359327

RESUMEN

The aim of this study was to assess (1) the incidence of patent foramen ovale (PFO) in carcinoid syndrome (CS) and (2) the feasibility of percutaneous closure procedure in selected patients with CS. One hundred eight patients were prospectively studied: 54 with CS and an age- and gender-matched control group. All patients underwent conventional and contrast echocardiography. Patients with clinical signs of dyspnea (New York Heart Association class > or =III), cyanosis, carcinoid heart disease (CHD), and severe PFO were referred for the percutaneous closure of PFO. The prevalence of PFO was 41% in patients with CS and 22% in the control group (p = 0.03) and was significantly higher in patients with CHD (59%, p = 0.009). Four patients (14% of those with CHD) were referred for the percutaneous closure of PFO, and 3 patients ultimately underwent PFO closure (using Amplatzer septal occluders). At 6-month follow-up, New York Heart Association class was improved in all patients, as well as arterial blood gas results (p = 0.04) and 6-minute walking distance (p = 0.03), but all patients presented residual right-to-left shunts. In conclusion, this prospective study demonstrates that in patients with CHD, the prevalence of PFO is high and that percutaneous closure of PFO is feasible, with a reduction in symptoms but with residual shunting.


Asunto(s)
Cardiopatía Carcinoide/epidemiología , Foramen Oval Permeable/epidemiología , Foramen Oval Permeable/terapia , Implantación de Prótesis , Anciano , Cardiopatía Carcinoide/complicaciones , Cateterismo Cardíaco , Estudios de Casos y Controles , Estudios de Factibilidad , Femenino , Foramen Oval Permeable/complicaciones , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...