Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Neurology ; 101(24): e2522-e2532, 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-37848336

RESUMEN

BACKGROUND AND OBJECTIVES: Endovascular thrombectomy (EVT) is standard treatment for anterior large vessel occlusion stroke (LVO-a stroke). Prehospital diagnosis of LVO-a stroke would reduce time to EVT by allowing direct transportation to an EVT-capable hospital. We aim to evaluate the diagnostic accuracy of dry electrode EEG for the detection of LVO-a stroke in the prehospital setting. METHODS: ELECTRA-STROKE was an investigator-initiated, prospective, multicenter, diagnostic study, performed in the prehospital setting. Adult patients were eligible if they had suspected stroke (as assessed by the attending ambulance nurse) and symptom onset <24 hours. A single dry electrode EEG recording (8 electrodes) was performed by ambulance personnel. Primary endpoint was the diagnostic accuracy of the theta/alpha frequency ratio for LVO-a stroke (intracranial ICA, A1, M1, or proximal M2 occlusion) detection among patients with EEG data of sufficient quality, expressed as the area under the receiver operating characteristic curve (AUC). Secondary endpoints were diagnostic accuracies of other EEG features quantifying frequency band power and the pairwise derived Brain Symmetry Index. Neuroimaging was assessed by a neuroradiologist blinded to EEG results. RESULTS: Between August 2020 and September 2022, 311 patients were included. The median EEG duration time was 151 (interquartile range [IQR] 151-152) seconds. For 212/311 (68%) patients, EEG data were of sufficient quality for analysis. The median age was 74 (IQR 66-81) years, 90/212 (42%) were women, and the median baseline NIH Stroke Scale was 1 (IQR 0-4). Six (3%) patients had an LVO-a stroke, 109/212 (51%) had a non-LVO-a ischemic stroke, 32/212 (15%) had a transient ischemic attack, 8/212 (4%) had a hemorrhagic stroke, and 57/212 (27%) had a stroke mimic. AUC of the theta/alpha ratio was 0.80 (95% CI 0.58-1.00). Of the secondary endpoints, the pairwise derived Brain Symmetry Index in the delta frequency band had the highest diagnostic accuracy (AUC 0.91 [95% CI 0.73-1.00], sensitivity 80% [95% CI 38%-96%], specificity 93% [95% CI 88%-96%], positive likelihood ratio 11.0 [95% CI 5.5-21.7]). DISCUSSION: The data from this study suggest that dry electrode EEG has the potential to detect LVO-a stroke among patients with suspected stroke in the prehospital setting. Toward future implementation of EEG in prehospital stroke care, EEG data quality needs to be improved. TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov identifier: NCT03699397. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that prehospital dry electrode scalp EEG accurately detects LVO-a stroke among patients with suspected acute stroke.


Asunto(s)
Arteriopatías Oclusivas , Isquemia Encefálica , Servicios Médicos de Urgencia , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Adulto , Humanos , Femenino , Anciano , Masculino , Servicios Médicos de Urgencia/métodos , Estudios Prospectivos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/terapia , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/terapia
2.
Front Neurol ; 13: 1018493, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36262832

RESUMEN

Background: Endovascular thrombectomy (EVT) is the standard treatment for large vessel occlusion stroke of the anterior circulation (LVO-a stroke). Approximately half of EVT-eligible patients are initially presented to hospitals that do not offer EVT. Subsequent inter-hospital transfer delays treatment, which negatively affects patients' prognosis. Prehospital identification of patients with LVO-a stroke would allow direct transportation of these patients to an EVT-capable center. Electroencephalography (EEG) may be suitable for this purpose because of its sensitivity to cerebral ischemia. The hypothesis of ELECTRA-STROKE is that dry electrode EEG is feasible for prehospital detection of LVO-a stroke. Methods: ELECTRA-STROKE is an investigator-initiated, diagnostic study. EEG recordings will be performed in patients with a suspected stroke in the ambulance. The primary endpoint is the diagnostic accuracy of the theta/alpha ratio for the diagnosis of LVO-a stroke, expressed by the area under the receiver operating characteristic (ROC) curve. EEG recordings will be performed in 386 patients. Discussion: If EEG can be used to identify LVO-a stroke patients with sufficiently high diagnostic accuracy, it may enable direct routing of these patients to an EVT-capable center, thereby reducing time-to-treatment and improving patient outcomes. Clinical trial registration: ClinicalTrials.gov, identifier: NCT03699397.

3.
Stroke ; 52(7): e347-e355, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33940955

RESUMEN

A reliable and fast instrument for prehospital detection of large vessel occlusion (LVO) stroke would be a game-changer in stroke care, because it would enable direct transportation of LVO stroke patients to the nearest comprehensive stroke center for endovascular treatment. This strategy would substantially improve treatment times and thus clinical outcomes of patients. Here, we outline our view on the requirements of an effective prehospital LVO detection method, namely: high diagnostic accuracy; fast application and interpretation; user-friendliness; compactness; and low costs. We argue that existing methods for prehospital LVO detection, including clinical scales, mobile stroke units and transcranial Doppler, do not fulfill all criteria, hindering broad implementation of these methods. Instead, electroencephalography may be suitable for prehospital LVO detection since in-hospital studies have shown that quantification of hypoxia-induced changes in the electroencephalography signal have good diagnostic accuracy for LVO stroke. Although performing electroencephalography measurements in the prehospital setting comes with challenges, solutions for fast and simple application of this method are available. Currently, the feasibility and diagnostic accuracy of electroencephalography in the prehospital setting are being investigated in clinical trials.


Asunto(s)
Trastornos Cerebrovasculares/fisiopatología , Electroencefalografía/métodos , Servicios Médicos de Urgencia/métodos , Accidente Cerebrovascular Isquémico/fisiopatología , Triaje/métodos , Trastornos Cerebrovasculares/diagnóstico por imagen , Trastornos Cerebrovasculares/terapia , Humanos , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Accidente Cerebrovascular Isquémico/terapia , Telemedicina/métodos , Ultrasonografía Doppler Transcraneal/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...