Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
J Med Radiat Sci ; 70 Suppl 2: 48-58, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36088635

RESUMEN

INTRODUCTION: In this study, we aimed to investigate the feasibility of gadoxetate low-temporal resolution (LTR) DCE-MRI for voxel-based hepatic extraction fraction (HEF) quantification for liver sparing radiotherapy using a deconvolution analysis (DA) method. METHODS: The accuracy and consistency of the deconvolution implementation in estimating liver function was first assessed using simulation data. Then, the method was applied to DCE-MRI data collected retrospectively from 64 patients (25 normal liver function and 39 cirrhotic patients) to generate HEF maps. The normal liver function patient data were used to measure the variability of liver function quantification. Next, a correlation between HEF and ALBI score (a new model for assessing the severity of liver dysfunction) was assessed using Pearson's correlation. Differences in HEF between Child-Pugh score classifications were assessed for significance using the Kruskal-Wallis test for all patient groups and Mann-Whitney U-test for inter-groups. A statistical significance was considered at a P-value <0.05 in all tests. RESULTS: The results showed that the implemented method accurately reproduced simulated liver function; root-mean-square error between estimated and simulated liver response functions was 0.003, and the coefficient-of-variance of HEF was <20%. HEF correlation with ALBI score was r = -0.517, P < 0.0001, and HEF was significantly decreased in the cirrhotic patients compared to normal patients (P < 0.0001). Also, HEF in Child-Pugh B/C was significantly lower than in Child-Pugh A (P = 0.024). CONCLUSION: The study demonstrated the feasibility of gadoxetate LTR-DCE MRI for voxel-based liver function quantification using DA. HEF could distinguish between different grades of liver function impairment and could potentially be used for functional guidance in radiotherapy.


Asunto(s)
Cirrosis Hepática , Neoplasias Hepáticas , Humanos , Estudios Retrospectivos , Cirrosis Hepática/diagnóstico por imagen , Imagen por Resonancia Magnética , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/radioterapia
2.
Neuroradiol J ; 35(5): 592-599, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35118885

RESUMEN

BACKGROUND AND PURPOSE: Diffusion tensor imaging (DTI) can detect microstructural changes of white matter in multiple sclerosis (MS) and might clarify mechanisms responsible for disability. Thus, we aimed to compare DTI metrics in relapsing-remitting MS patients (RRMS) with healthy controls (HCs), and explore the correlations between DTI metrics, total brain white matter (TBWM) and white matter lesion (WML) with clinical parameters compared to volumetric measures. MATERIAL AND METHODS: 37 RRMS patients and 19 age/sex-matched HCs were included. All participants had clinical assessments, structural and diffusion scans on a 3T MRI. Volumetric and white matter DTI metrics; fractional anisotropy (FA), mean, radial and axial diffusivities (MD, RD and AD) were estimated and correlated with clinical parameters. The mean group differences were calculated using t-tests, and univariate correlations with Pearson correlation coefficients. RESULTS: Compared to HCs, statistically significant increases in MD (+3.6%), RD (+4.8%), AD (+2.7%) and a decrease in FA (-4.3%) for TBWM in RRMS was observed (p < .01). MD and RD in TBWM and AD in WML correlated moderately with disability status. Volumetric segmentation indicated a decrease in the total brain volume, GM and WM(-5%) with a reciprocal increase in CSF(+26%) in RRMS(p < .01). Importantly, DTI parameters showed a medium correlation with cognitive domains in contrast to white matter-related volumetric measurements in RRMS(Pearson correlation, p < .05). CONCLUSIONS: Our study shows a correlation of DTI metrics with clinical symptoms of MS, in particular cognition. More generally, these findings indicated that DTI is a useful and unique technique for evaluating the clinical features of white matter disease and warrants further investigation into its clinical role.


Asunto(s)
Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Sustancia Blanca , Benchmarking , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen de Difusión Tensora/métodos , Humanos , Esclerosis Múltiple/patología , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/patología , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología
3.
J Biomed Sci ; 28(1): 54, 2021 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-34281540

RESUMEN

BACKGROUND: Current multiparametric MRI (mp-MRI) in routine clinical practice has poor-to-moderate diagnostic performance for transition zone prostate cancer. The aim of this study was to evaluate the potential diagnostic performance of novel 1H magnetic resonance spectroscopic imaging (MRSI) using a semi-localized adiabatic selective refocusing (sLASER) sequence with gradient offset independent adiabaticity (GOIA) pulses in addition to the routine mp-MRI, including T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI) and quantitative dynamic contrast enhancement (DCE) for transition zone prostate cancer detection, localization and grading. METHODS: Forty-one transition zone prostate cancer patients underwent mp-MRI with an external phased-array coil. Normal and cancer regions were delineated by two radiologists and divided into low-risk, intermediate-risk, and high-risk categories based on TRUS guided biopsy results. Support vector machine models were built using different clinically applicable combinations of T2WI, DWI, DCE, and MRSI. The diagnostic performance of each model in cancer detection was evaluated using the area under curve (AUC) of the receiver operating characteristic diagram. Then accuracy, sensitivity and specificity of each model were calculated. Furthermore, the correlation of mp-MRI parameters with low-risk, intermediate-risk and high-risk cancers were calculated using the Spearman correlation coefficient. RESULTS: The addition of MRSI to T2WI + DWI and T2WI + DWI + DCE improved the accuracy, sensitivity and specificity for cancer detection. The best performance was achieved with T2WI + DWI + MRSI where the addition of MRSI improved the AUC, accuracy, sensitivity and specificity from 0.86 to 0.99, 0.83 to 0.96, 0.80 to 0.95, and 0.85 to 0.97 respectively. The (choline + spermine + creatine)/citrate ratio of MRSI showed the highest correlation with cancer risk groups (r = 0.64, p < 0.01). CONCLUSION: The inclusion of GOIA-sLASER MRSI into conventional mp-MRI significantly improves the diagnostic accuracy of the detection and aggressiveness assessment of transition zone prostate cancer.


Asunto(s)
Espectroscopía de Resonancia Magnética/uso terapéutico , Imágenes de Resonancia Magnética Multiparamétrica/estadística & datos numéricos , Neoplasias de la Próstata/diagnóstico , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Persona de Mediana Edad , Neoplasias de la Próstata/diagnóstico por imagen
4.
Magn Reson Imaging ; 74: 21-30, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32898652

RESUMEN

PURPOSE: To evaluate the performance of novel spiral MRSI and tissue segmentation pipeline of the brain, to investigate neurometabolic changes in normal-appearing white matter (NAWM) and white matter lesions (WML) of stable relapsing remitting multiple sclerosis (RRMS) compared to healthy controls (HCs). METHODS: Spiral 3D MRSI using LASER-GOIA-W [16,4] was undertaken on 16 RRMS patients and 9 HCs, to acquire MRSI data from a large volume of interest (VOI) 320 cm3 and analyzed using LCModel. MRSI data and voxel tissue segmentation were compared between the two cohorts using t-tests. Support vector machine (SVM) was used to classify tissue types and assessed by accuracy, sensitivity and specificity. RESULTS: Compared to HCs, RRMS demonstrated a statistically significant reduction in all mean brain tissues and increase in CSF volume. Within VOI, WM decreased (-10%) and CSF increased (41%) in RRMS compared to HCs (p < 0.001). MRSI revealed that total creatine (tCr) ratios of N-acetylaspartate and glutamate+glutamine in WML were significantly lower than NAWM-MS (-9%, -8%) and HCs (-14%, -10%), respectively. Myo-inositol/tCr in WML was significantly higher than NAWM-MS (14%) and HCs (10%). SVM of MRSI yielded accuracy, sensitivity and specificity of 86%, 95%, and 70%, respectively for HCs vs WML, which were higher than HC vs NAWM and WML vs NAWM models. CONCLUSION: This study demonstrates the benefit of MRSI in evaluating MS neurometabolic changes in NAWM. SVM of MRSI data in the MS brain may be suited for clinical monitoring and progression of MS patients. Longitudinal MRSI studies are warranted.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética , Esclerosis Múltiple Recurrente-Remitente/diagnóstico por imagen , Esclerosis Múltiple Recurrente-Remitente/patología , Sustancia Blanca/diagnóstico por imagen , Adulto , Femenino , Humanos , Persona de Mediana Edad , Máquina de Vectores de Soporte , Sustancia Blanca/patología
5.
J Appl Clin Med Phys ; 21(10): 179-191, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32770600

RESUMEN

PURPOSE: The aim of this study was to develop and assess the performance of supervised machine learning technique to classify magnetic resonance imaging (MRI) voxels as cancerous or noncancerous using noncontrast multiparametric MRI (mp-MRI), comprised of T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and advanced diffusion tensor imaging (DTI) parameters. MATERIALS AND METHODS: In this work, 191 radiomic features were extracted from mp-MRI from prostate cancer patients. A comprehensive set of support vector machine (SVM) models for T2WI and mp-MRI (T2WI + DWI, T2WI + DTI, and T2WI + DWI + DTI) were developed based on novel Bayesian parameters optimization method and validated using leave-one-patient-out approach to eliminate any possible overfitting. The diagnostic performance of each model was evaluated using the area under the receiver operating characteristic curve (AUROC). The average sensitivity, specificity, and accuracy of the models were evaluated using the test data set and the corresponding binary maps generated. Finally, the SVM plus sigmoid function of the models with the highest performance were used to produce cancer probability maps. RESULTS: The T2WI + DWI + DTI models using the optimal feature subset achieved the best performance in prostate cancer detection, with the average AUROC , sensitivity, specificity, and accuracy of 0.93 ± 0.03, 0.85 ± 0.05, 0.82 ± 0.07, and 0.83 ± 0.04, respectively. The average diagnostic performance of T2WI + DTI models was slightly higher than T2WI + DWI models (+3.52%) using the optimal radiomic features. CONCLUSIONS: Combination of noncontrast mp-MRI (T2WI, DWI, and DTI) features with the framework of a supervised classification technique and Bayesian optimization method are able to differentiate cancer from noncancer voxels with high accuracy and without administration of contrast agent. The addition of cancer probability maps provides additional functionality for image interpretation, lesion heterogeneity evaluation, and treatment management.


Asunto(s)
Imágenes de Resonancia Magnética Multiparamétrica , Neoplasias de la Próstata , Teorema de Bayes , Imagen de Difusión Tensora , Humanos , Imagen por Resonancia Magnética , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Estudios Retrospectivos , Sensibilidad y Especificidad , Aprendizaje Automático Supervisado
6.
Urol Oncol ; 38(4): 150-173, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31937423

RESUMEN

Prostate cancer is the most common solid organ cancer in men, and the second most common cause of male cancer-related mortality. It has few effective therapies, and is difficult to diagnose accurately. Prostate-specific antigen (PSA), which is currently the most effective diagnostic tool available, cannot reliably discriminate between different pathologies, and in fact only around 30% of patients found to have elevated levels of PSA are subsequently confirmed to actually have prostate cancer. As such, there is a desperate need for more reliable diagnostic tools that will allow the early detection of prostate cancer so that the appropriate interventions can be applied. Nuclear magnetic resonance (NMR) spectroscopy and magnetic resonance spectroscopy (MRS) are 2 high throughput, noninvasive analytical procedures that have the potential to enable differentiation of prostate cancer from other pathologies using metabolomics, by focusing specifically on certain metabolites which are associated with the development of prostate cancer cells and its progression. The value that this type of approach has for the early detection, diagnosis, prognosis, and personalized treatment of prostate cancer is becoming increasingly apparent. Recent years have seen many promising developments in the fields of NMR spectroscopy and MRS, with improvements having been made to hardware as well as to techniques associated with the acquisition, processing, and analysis of related data. This review focuses firstly on proton NMR spectroscopy of blood serum, urine, and expressed prostatic secretions in vitro, and then on 1- and 2-dimensional proton MRS of the prostate in vivo. Major advances in these fields and methodological principles of data collection, acquisition, processing, and analysis are described along with some discussion of related challenges, before prospects that proton MRS has for future improvements to the clinical management of prostate cancer are considered.


Asunto(s)
Líquidos Corporales/diagnóstico por imagen , Espectroscopía de Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/diagnóstico , Humanos , Masculino , Neoplasias de la Próstata/terapia
7.
J Magn Reson Imaging ; 50(6): 1926-1936, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31132193

RESUMEN

BACKGROUND: Due to the histological heterogeneity of the central gland, accurate detection of central gland prostate cancer remains a challenge. PURPOSE: To evaluate the efficacy of in vivo 3D 1 H MR spectroscopic imaging (3D 1 H MRSI) with a semi-localized adiabatic selective refocusing (sLASER) sequence and gradient-modulated offset-independent adiabatic (GOIA) pulses for detection of central gland prostate cancer. Additionally four risk models were developed to differentiate 1) normal vs. cancer, 2) low- vs. high-risk cancer, 3) low- vs. intermediate-risk cancer, and 4) intermediate- vs. high-risk cancer voxels. STUDY TYPE: Prospective. SUBJECTS: Thirty-six patients with biopsy-proven central gland prostate cancer. FIELD STRENGTH/SEQUENCE: 3T MRI / 3D 1 H MRSI using GOIA-sLASER. ASSESSMENT: Cancer and normal regions of interest (ROIs) were selected by an experienced radiologist and 1 H MRSI voxels were placed within the ROIs to calculate seven metabolite signal ratios. Voxels were split into two subsets, 80% for model training and 20% for testing. STATISTICAL TESTS: Four support vector machine (SVM) models were built using the training dataset. The accuracy, sensitivity, and specificity for each model were calculated for the testing dataset. RESULTS: High-quality MR spectra were obtained for the whole central gland of the prostate. The normal vs. cancer diagnostic model achieved the highest predictive performance with an accuracy, sensitivity, and specificity of 96.2%, 95.8%, and 93.1%, respectively. The accuracy, sensitivity, and specificity of the low- vs. high-risk cancer and low- vs. intermediate-risk cancer models were 82.5%, 89.2%, 70.2%, and 73.0%, 84.7%, 60.8%, respectively. The intermediate- vs. high-risk cancer model yielded an accuracy, sensitivity, and specificity lower than 55%. DATA CONCLUSION: The GOIA-sLASER sequence with an external phased-array coil allows for fast assessment of central gland prostate cancer. The classification offers a promising diagnostic tool for discriminating normal vs. cancer, low- vs. high-risk cancer, and low- vs. intermediate-risk cancer. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;50:1926-1936.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Espectroscopía de Resonancia Magnética/métodos , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Procesamiento de Señales Asistido por Computador , Anciano , Diagnóstico Diferencial , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad
8.
Australas Phys Eng Sci Med ; 42(1): 137-147, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30637607

RESUMEN

Magnetic resonance images (MRI) require intensity standardisation if they are used for the purpose of quantitative analysis as inherent variations in image intensity levels between different image sets are manifest due to technical factors. One approach is to standardise the image intensity values using a statistically applied biological reference tissue. The aim of this study is to compare the performance of differing candidate biological reference tissues for standardising T2WI intensity distributions. Fifty-one prostate cancer patients across two centres with different scanners were evaluated using the percentage interpatient coefficient of variation (%interCV) for four different biological references; femoral bone marrow, ischioanal fossa, obturator-internus muscle and bladder urine. The tissue with the highest reproducibility (lowest %interCV) in both centres was used for intensity standardisation of prostate T2WI using three different statistical measures (mean, Z-score, median + Interquartile Range). The performance of different standardisation methods was evaluated from the assessment of image intensity histograms and the percentage normalised root mean square error (%NRSME) of the healthy peripheral zone tissue. Ischioanal fossa as a reference tissue demonstrated the highest reproducibility with %interCV of 18.9 for centre1 and 11.2 for centre2. Using ischioanal fossa for statistical intensity standardisation and the median + Interquartile Range method demonstrated the lowest %NRMSE across centres for healthy peripheral zone tissues. This study demonstrates ischioanal fossa as a preferred reference tissue for standardising intensity values from T2WI of the prostate. Subsequent image standardisation using the median + Interquartile Range intensity of the reference tissue demonstrated a robust and reliable standardisation method for quantitative image assessment.


Asunto(s)
Imagen por Resonancia Magnética/normas , Próstata/diagnóstico por imagen , Estadística como Asunto , Algoritmos , Humanos , Masculino , Estándares de Referencia
9.
Eur J Radiol ; 110: 112-120, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30599846

RESUMEN

PURPOSE: This study is aimed at evaluating the potential role of quantitative magnetic resonance diffusion tensor imaging (DTI) and tractography parameters in the detection and characterization of peripheral zone prostate cancer with a particular attention for fiber tract density. MATERIALS AND METHODS: DTI was acquired from eleven high risk, transrectal ultrasound (TRUS)-guided biopsy proven prostate cancers with perineural invasion (histological Gleason score ≥ 7) on a 3 T magnet. Twenty parameters derived from DTI were quantified in cancer and healthy regions of the prostate. In addition, fiber tract density in normal versus cancer tissues was also calculated using DTI tractography. Support vector machine with a radial basis function kernel and area under receiver operator characteristic (ROC) were used to describe and compare the diagnostic performance of combined fractional anisotropy (FA) and mean diffusivity (MD) and other statistically significant DTI parameters. Spearman correlation analysis between DTI parameters and Gleason scores was conducted. RESULTS: Eighteen DTI parameters yielded statistically significant differences between cancer and healthy regions (p-value < 0.05). The ROC curve of all statistically significant DTI parameters between cancer and healthy regions was higher than the area under ROC curve using FA + MD alone (95% confidence interval = 0.988, range = 0.975-1.00) vs (95% confidence interval = 0.935, range = 0.898-0.999), respectively (p-value < 0.05). Fiber tract density was also found to be higher in cancer than in healthy tissues (+38.22%, p-value = 0.010) and may be related to the increase in nerve and vascular density reported in prostate cancer. The linear and relative anisotropy were highly correlated with Gleason score (Spearman correlation factor r = 0.655, p-value = 0.001 and r = 0.667, p-value < 0.001, respectively). CONCLUSIONS: DTI has the potential to provide imaging biomarkers in the detection and characterization of prostate cancer. Novel quantitative parameters derived from DTI and DTI tractography, including fiber tract density, support the use of DTI in the assessment of high grade prostate cancer.


Asunto(s)
Próstata/patología , Neoplasias de la Próstata/patología , Adulto , Algoritmos , Anisotropía , Imagen de Difusión Tensora/métodos , Detección Precoz del Cáncer/métodos , Humanos , Biopsia Guiada por Imagen/métodos , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Invasividad Neoplásica , Neoplasias del Sistema Nervioso/patología , Estudios Prospectivos , Curva ROC
10.
Hemoglobin ; 41(3): 151-156, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28762844

RESUMEN

Diabetes mellitus (DM) is one of the potential complications in patients with transfusion-dependent ß-thalassemia major (ß-TM). In this case-controlled study, we examined the pancreatic iron levels in outpatients with ß-TM. In this study, cases of patients with ß-TM and DM were gender- and age-matched with control subjects, who were non-diabetic and had normal blood glucose on standard oral glucose tolerance (OGTT) tests. One of four diagnoses [normal, pre-diabetes, impaired glucose tolerance (IGT), DM] was made according to the American Diabetes Association (ADA) criteria. The T2*-weighted magnetic resonance imaging (T2*-weighted MRI) of the heart, liver, and pancreas was performed using a 1.5 Tesla scanner. The study enrolled 26 diabetic cases, 17 non-diabetic cases, and eight cases of IGT or pre-diabetes cases. The severity of pancreatic and cardiac iron siderosis was significantly different between the groups. We found a statistically significant difference at 5.6 ms in the T2*-weighted MRI values for the pancreas between patients with normal vs. abnormal glucose metabolism [p < 0.009; odds ratio (OR): 11.2; 95% confidence interval (95% CI): 1.32-94.4)]. The receiver operating characteristic (ROC) curve for the 5.6 ms cutoff led to an area under the curve (AUC) of 0.69 (95% CI: 55.0-84.0; p < 0.02), with sensitivity and specificity of 94.0 and 42.0%, respectively. There was a moderate positive correlation between pancreatic and cardiac T2*-weighted MRI (r = 0.4; p < 0.001), and a weak correlation between the pancreas and the liver (r = 0.38; p < 0.005). To conclude, we have introduced a cutoff of 5.6 ms on T2*-weighted MRI of the pancreas for prediction of abnormal glucose metabolism in ß-TM patients.


Asunto(s)
Complicaciones de la Diabetes/diagnóstico , Complicaciones de la Diabetes/metabolismo , Sobrecarga de Hierro/diagnóstico , Sobrecarga de Hierro/etiología , Imagen por Resonancia Magnética , Páncreas/patología , Talasemia beta/complicaciones , Adolescente , Adulto , Biomarcadores , Transfusión Sanguínea , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Glucosa/metabolismo , Humanos , Lactante , Recién Nacido , Hierro/metabolismo , Hígado/diagnóstico por imagen , Hígado/metabolismo , Hígado/patología , Imagen por Resonancia Magnética/métodos , Masculino , Curva ROC , Adulto Joven , Talasemia beta/terapia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...